McMaster-Carr logo
    Filter by
    Cage Depth
    Ladder Width
    Material
    Cage Width
    Assembly
    Ladder Type
    Foldable
    Mounting Hardware Included
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Flared Cage Depth
    Flared Cage Width
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    16 Products

    Ladder Cages

    Image of System. Front orientation. Contains Annotated. Ladder Cages.
    Feel secure on tall ladders. These cages surround the ladder to help reduce the risk of falls. Made of powder-coated steel, they resist rust, so you can use them outdoors. Each section is fully welded and mounts to the side rails of stationary ladders. They don’t mount to walls or other cages. For a complete assembly, you’ll need at least one middle/top section and one bottom section.
    Bottom Sections—Bottom sections are flared to give you room to enter or exit your cage.
    Middle/Top Sections—Middle/top sections make your cage longer. They can also act as a top section when your ladder system includes a hatch.
    Walk-Through Sections—Walk-through sections are required when you can step through the top of your ladder onto a landing. They should extend 42" above the top rung.
    Yellow—Yellow cages stand out in busy areas.
    Specifications Met—Note: Ladder cages meet OSHA and Cal/OSHA dimensional and construction standards. Check local, state, and federal codes, including OSHA, for safe set up and operating practices.
    Cage
    Flared
    Cage
    Gray
    Yellow
    Overall
    Ht., ft.
    Wd.
    Dp.
    Wd.
    Dp.
    For Ladder
    Wd.
    Max. Ladder
    Rail Dp.
    Wt.,
    lb.
    Mounting Hardware
    Included
    Specs. Met
    Each
    Each
    Powder-Coated Steel
     
    Bottom Sections
    238"34"38"38"16" to 20"2"47YesOSHA Compliant 29 CFR 1910.23, Cal/OSHA Compliant Title 8 Section 3277, ANSI-ASC A14.30000000000000000000000000000
    338"34"38"38"16" to 20"2"54YesOSHA Compliant 29 CFR 1910.23, Cal/OSHA Compliant Title 8 Section 3277, ANSI-ASC A14.300000000000000000000000000
    438"34"38"38"16" to 20"2"71YesOSHA Compliant 29 CFR 1910.23, Cal/OSHA Compliant Title 8 Section 3277, ANSI-ASC A14.300000000000000000000000000
     
    Middle/Top Sections
    230"30"16" to 20"2"55YesOSHA Compliant 29 CFR 1910.23, Cal/OSHA Compliant Title 8 Section 3277, ANSI-ASC A14.300000000000000000000000000
    330"30"16" to 20"2"61YesOSHA Compliant 29 CFR 1910.23, Cal/OSHA Compliant Title 8 Section 3277, ANSI-ASC A14.300000000000000000000000000
    430"30"16" to 20"2"68YesOSHA Compliant 29 CFR 1910.23, Cal/OSHA Compliant Title 8 Section 3277, ANSI-ASC A14.300000000000000000000000000
    730"30"16" to 20"2"110YesOSHA Compliant 29 CFR 1910.23, Cal/OSHA Compliant Title 8 Section 3277, ANSI-ASC A14.300000000000000000000000000
     
    Walk-Through Sections
    530"30"16" to 20"2"85YesOSHA Compliant 29 CFR 1910.23, Cal/OSHA Compliant Title 8 Section 3277, ANSI-ASC A14.300000000000000000000000000
     
    back to top