McMaster-Carr logo
    Filter by
    Electrical Phase
    For Fluid Cooling System Type
    Mounting Location
    Pipe Size
    Industrial Info Compare
    Temperature Control Method
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    25 Products

    Rack-Mount Liquid Chillers

    Image of Product. Front orientation. Liquid Chillers. Rack-Mount Liquid Chillers.
    Save floor space—these chillers mount to standard 19" electronics racks, enclosures, and cabinets. Because they're so compact, you can even fit multiple chillers on the same rack. Where other chillers only keep liquid cool within a few full degrees, these chillers are highly precise, maintaining constant, uniform temperatures within 0.18° F. This makes them ideal for equipment where small temperature changes could cause an issue for your process. Also called Peltier chillers, they cool using only electricity, so there's no compressors or refrigerants. Without a compressor, you'll hardly hear them when they're running.
    Fill these chillers with water or glycol solutions, and an internal pump moves the liquid through a cooling system and out to your equipment. There are multiple ways to control these chillers. Use the built-in keypad to manually set the temperature, or connect an external controller of your own to automate temperature changes. View the set temperature, pressure, and flow rate from the digital display. It will also display maintenance reminders and alarms.
    A port on the front lets you quickly check fluid levels and fill the chiller with fluid without removing it from the rack or disconnecting it from your system.
    Temp.
    Control
    Overall
    For Rack
    Wd.
    Cooling Cap.,
    BTU/hr
    Voltage (Electrical Phase)
    Current,
    amp
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Range,
    ° F
    Method
    Ht.
    Wd.
    Dp.
    Tank Cap.,
    gal.
    Each
    For Closed-Loop Fluid Cooling Systems
     
    Thermoelectric Cooled
    19"600100V AC-240V AC (Single Phase)2.50.8 gpm @ 5 psi1050 to 140External Controller, Keypad7"19"13 1/2"0.36452N11000000000
     

    Liquid Chillers

    Image of Product. Front orientation. Liquid Chillers.
    Circulate water or glycol solutions to prevent spot-welding systems, molds, lasers, and other temperature-sensitive equipment from overheating. These chillers provide constant, uniform temperatures. An internal tank ensures liquid flows in a continuous loop. Adjust the set temperature with the keypad.
    Bypass Valve—Chillers with a bypass valve recirculate liquid in the chiller if the outlet is obstructed.
    Cooling Capacity—Cooling capacity is based on a 65° F liquid temperature and a 95° F room temperature.
    Overall
    Cooling Cap.,
    BTU/hr
    Current,
    amp
    Compressor
    Power, hp
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Temp. Control
    Range, ° F
    Ht.
    Wd.
    Dp.
    Electrical
    Connection Type
    Tank Cap.,
    gal.
    Refrigerant
    No.
    Features
    Each
    120V AC (Single Phase)
    2,100131/42 gpm @ 50 psi5050 to 8028 5/8"22"21 1/8"Plug In5R-513ABypass Valve, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass8472N11000000000
    4,30015.51/24 gpm @ 50 psi5050 to 8028 5/8"22"21 1/8"Plug In5R-513ABypass Valve, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass3531K1500000000
     
    240V AC (Single Phase)
    11,3001714 gpm @ 50 psi5050 to 8033 3/8"31 1/8"25 1/8"Plug In10R-513ABypass Valve, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass3531K2500000000
     

    Precision Liquid Chillers

    Image of Product. Front orientation. Liquid Chillers. Precision Liquid Chillers, 120V AC (Single Phase).
    Image of Product. Front orientation. Liquid Chillers. Precision Liquid Chillers, 240V AC (Single Phase).

    120V AC (Single

    Phase)

    240V AC (Single

    Phase)

    Protect your most temperature-sensitive equipment from overheating. These chillers keep liquids within 0.18° F of the temperature you set. Far more advanced than basic chillers—which are accurate within a few full degrees—they’re even precise enough for use in medical imaging machines. Fill these chillers with distilled water or glycol solutions, and an internal pump moves the liquid out to your equipment and back in a continuous loop. They’re often used with spot-welding systems, molds, lasers, and X-ray diffraction equipment. Use the built-in keypad to manually set the temperature, or connect an external controller of your own to automate temperature changes. View the set temperature, alerts, and other information on the LED display.
    120V AC—120V AC chillers automatically replace their own filter, using a roller to swap in a fresh filter on a set schedule. Adjust the schedule to suit your application. A UV light system prevents algae and other bacteria growth, keeping the cooling liquid clean.
    240V AC—240V AC chillers have a bypass valve knob to control the chiller’s flow rate and pressure, which can affect the temperature of your liquid and how efficiently these coolers run.
    Overall
    Cooling Cap.,
    BTU/hr
    Current,
    amp
    Compressor
    Power, hp
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Temp. Control
    Range, ° F
    Temp. Tolerance,
    ° F
    Ht.
    Wd.
    Dp.
    Electrical
    Connection Type
    Tank Cap.,
    gal.
    Refrigerant
    No.
    Each
    120V AC (Single Phase)
    2,90013.71/43.5 gpm @ 90 psi9015 to 155-18 to 1821 7/8"15"26"Plug In1.1R-513A8886T11000000000
    5,94017.41/23.5 gpm @ 90 psi9015 to 155-18 to 1821 7/8"15"26"Plug In1.1R-513A8886T1200000000
     
    240V AC (Single Phase)
    10,92015.51 1/46 gpm @ 45 psi4550 to 80-0.09 to 0.0930 9/16"14 1/8"31 13/16"Plug In1.5R-513A8886T30100000000
    24,00033.4310 gpm @ 45 psi4550 to 80-0.09 to 0.0934 7/8"18"33 13/16"Hardwire2.5R-513A8886T302000000000
    36,00045.34 1/410 gpm @ 45 psi4550 to 80-0.09 to 0.0949 3/8"18"31 13/16"Hardwire2.5R-513A8886T303000000000
     

    Bench-Top Liquid Chillers

    Image of Product. Front orientation. Liquid Chillers. Bench-Top Liquid Chillers.
    Send cool water to equipment right from your bench top without compromising precision. These chillers maintain constant, uniform temperatures within 0.2° F where other chillers only keep liquid cool within a few full degrees. This makes them ideal for equipment where small temperature changes could cause an issue, such as microscope cooling plates.
    Fill these chillers with water or glycol solutions, and an internal pump moves the liquid through a cooling system and out to your equipment. Use the built-in keypad to manually set the temperature, or connect an external controller of your own to automate temperature changes. View the set temperature, alerts, and other information from the LED display.
    Overall
    Cooling Cap.,
    BTU/hr
    Voltage (Electrical
    Phase)
    Current,
    amp
    Compressor
    Power, hp
    Max. Flow Rate
    @ Pressure
    Max. Pressure,
    psi
    Temp. Control
    Range, ° F
    Ht.
    Wd.
    Dp.
    Accuracy
    Tank Cap.,
    fl. oz.
    Refrigerant
    No.
    Features
    Each
    For Closed-Loop Fluid Cooling Systems
     
    Refrigerant Cooled
    3,400120V AC (Single Phase)3.31/66 gpm @ 16 psi160 to 8018 7/16"9 1/8"18 3/16"±1.8%51R-513AUV Light System6592N11000000000
     

    Heat Sinks for Water

    Image of Product. Front orientation. Heat Sinks. Heat Sinks for Water, 1 Fan.
    Image of Product. Front orientation. Heat Sinks. Heat Sinks for Water, 2 Fans.

    1 Fan

    2 Fans

    A fan cools water as it moves through the tubes to dissipate heat. These heat sinks have flanges with mounting slots for installation in frames and cabinets. Overall height, width, and depth do not include tube ends.
    316 Stainless Steel Tube—Heat sinks with 316 stainless steel tubes have excellent corrosion resistance to withstand deionized water and other corrosive liquid.
    Overall
    Cooling Cap.,
    BTU/hr
    Gender
    Ht.
    Wd.
    Dp.
    Heat Sink
    Material
    No. of
    Fans
    Max. Pressure,
    psi
    Max. Flow
    Rate, gpm
    Max. Temp.,
    ° F
    Voltage (Electrical
    Phase)
    Current,
    amp
    Cord Lg.,
    ft.
    Mounting
    Slot Wd.
    Tube
    OD
    Choose a Fitting
    Connection
    Each
    Copper Tube—For Water
    1,300Male6 9/16"6 3/4"2 13/16"Copper11502400120V AC (Single)0.1623/16"3/8"
    37° Flared
    ,
    Tube Stem
    35145K710000000
    1,500Male5 3/4"6 1/2"3 5/8"Copper11502400120V AC (Single)0.1627/32"3/8"
    37° Flared
    ,
    Tube Stem
    35145K72000000
    2,200Male5 3/4"11 3/8"3 5/16"Copper21502400120V AC (Single)0.1627/32"3/8"
    37° Flared
    ,
    Tube Stem
    35145K73000000
    4,200Male9"9 11/16"4 1/2"Copper11502400120V AC (Single)0.2527/32"3/8"
    37° Flared
    ,
    Tube Stem
    35145K74000000
    4,400Male12"11 11/16"6 1/16"Copper11504400120V AC (Single)0.2927/32"1/2"
    37° Flared
    ,
    Tube Stem
    35145K4600000000
    7,100Male9"17 11/16"4 1/2"Copper21502400120V AC (Single)0.2527/32"3/8"
    37° Flared
    ,
    Tube Stem
    35145K7500000000
    8,800Male12"21 15/16"5 5/8"Copper21504400120V AC (Single)0.2927/32"1/2"
    37° Flared
    ,
    Tube Stem
    35145K4700000000
     
    316 Stainless Steel Tube—For Corrosive Liquids and Deionized Water
    1,300Male6 9/16"7"2 13/16"Stainless Steel
    11502400120V AC (Single)0.1623/16"3/8"
    37° Flared
    ,
    Tube Stem
    35145K81000000
    1,500Male5 13/16"6 1/8"3 11/16"Stainless Steel
    11502400120V AC (Single)0.1623/16"3/8"
    37° Flared
    ,
    Tube Stem
    35145K8200000000
    2,200Male5 13/16"10 7/8"3 11/16"Stainless Steel
    21502400120V AC (Single)0.1623/16"3/8"Tube Stem35145K52300000000
    4,200Male9"9 3/16"4 13/16"Stainless Steel
    11502400120V AC (Single)0.2523/16"3/8"
    37° Flared
    ,
    Tube Stem
    35145K8400000000
    4,400Male12"11 3/16"6 1/16"Stainless Steel
    11504400120V AC (Single)0.2923/16"1/2"Tube Stem35145K72600000000
    7,100Male9"17 3/16"4 1/2"Stainless Steel
    21502400120V AC (Single)0.2523/16"3/8"Tube Stem35145K52500000000
    8,800Male12"21 3/16"6 1/16"Stainless Steel
    21504400120V AC (Single)0.2923/16"1/2"Tube Stem35145K72700000000
     

    Heat Sinks with Internal Pump for Water

    Image of Product. Front orientation. Heat Sinks. Heat Sinks with Internal Pump for Water.
    Image of Attribute. 5-15. Front orientation. NEMA 5-15. Heat Sinks with Internal Pump for Water.

    5-15

    To provide a more consistent flow of cooled water than other heat sinks for water, these have a built-in pump and reservoir. The internal fan-cooled heat exchanger dissipates heat. Btu/hr. cooling capacity is based on water with an initial temperature difference of 77° F.
    Overall
    Cooling Cap.,
    BTU/hr
    Pipe
    Size
    Thread
    Type
    Gender
    Ht.
    Wd.
    Dp.
    Heat Sink
    Material
    Max. Pressure,
    psi
    Max. Flow
    Rate, gpm
    Max. Temp.,
    ° F
    Voltage (Electrical
    Phase)
    Current,
    amp
    NEMA
    Type
    Cord Lg.,
    ft.
    Fitting
    Connection
    Each
    For Water and Noncorrosive Liquids
    12,0001/2
    NPT
    Female24"15"15"Copper601.8130120V AC (Single)5.85-15
    8Threaded35205K16000000000
     