Low-Temperature Liquid Chillers
![]() |
Chill coolant down to 0° F—the lowest temperature liquid chillers we offer. They're often used when you want to maintain temperatures below freezing, such as in food processing and for sensitive electronic components. They take your fluid down to a constant uniform temperature and pump that liquid into your cooling system. Monitor the temperature and pressure of the coolant on the LCD display and change the settings using the keypad. They have a window to quickly check the fluid level. This window also acts as a spot to drain or fill the chiller.
Cannot Be Sold To—Liquid chillers cannot be sold to the listed areas due to chemical regulations.
Overall | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Cap., BTU/hr | Voltage (Electrical Phase) | Current, amp | Compressor Power, hp | Max. Flow Rate @ Pressure | Max. Pressure, psi | Temp. Control Range, ° F | Ht. | Wd. | Dp. | Tank Cap., gal. | Refrigerant No. | Features | Cannot Be Sold To | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Closed-Loop Fluid Cooling Systems | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13,600 | 460V AC (Three Phase) | 22 | 2 | 10 gpm @ 28 psi | 150 | 0 to 40 | 54 3/8" | 31 5/8" | 31 5/8" | 12 | R-404A | Liquid-Level Sight Glass | Canada | 0000000 | 0000000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Liquid Chillers
![]() |
Circulate water or glycol solutions to prevent spot-welding systems, molds, lasers, and other temperature-sensitive equipment from overheating. These chillers provide constant, uniform temperatures. An internal tank ensures liquid flows in a continuous loop. Adjust the set temperature with the keypad.
Bypass Valve—Chillers with a bypass valve recirculate liquid in the chiller if the outlet is obstructed.
Cooling Capacity—Cooling capacity is based on a 65° F liquid temperature and a 95° F room temperature.
Overall | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Cap., BTU/hr | Current, amp | Compressor Power, hp | Max. Flow Rate @ Pressure | Max. Pressure, psi | Temp. Control Range, ° F | Ht. | Wd. | Dp. | Tank Cap., gal. | Refrigerant No. | Features | Each | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
120V AC (Single Phase) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
4,300 | 15.5 | 1/2 | 4 gpm @ 50 psi | 50 | 50 to 80 | 28 5/8" | 22" | 21 1/8" | 5 | R-513A | Bypass Valve, Electrical Controls with Shut-Off Switch, Liquid-Level Sight Glass | 0000000 | 000000000 | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||