Bench-Top Liquid Chillers
![]() |
Send cool water to equipment right from your bench top without compromising precision. These chillers maintain constant, uniform temperatures within 0.2° F where other chillers only keep liquid cool within a few full degrees. This makes them ideal for equipment where small temperature changes could cause an issue, such as microscope cooling plates.
Fill these chillers with water or glycol solutions, and an internal pump moves the liquid through a cooling system and out to your equipment. Use the built-in keypad to manually set the temperature, or connect an external controller of your own to automate temperature changes. View the set temperature, alerts, and other information from the LED display.
500 BTU/hr Cooling Capacity—Chillers rated for 500 Btu/hr. are also known as Peltier chillers. They cool liquid using electricity—no need for compressors or refrigerants. Because they don’t use a compressor, you’ll hardly hear them when they’re on. To check fluid levels at a glance, their tank inlet is semi-clear.
Overall | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Cap., BTU/hr | Wire Connection | Voltage (Electrical Phase) | Current, amp | Compressor Power, hp | Max. Flow Rate @ Pressure | Max. Pressure, psi | Temp. Control Range, ° F | Ht. | Wd. | Dp. | Accuracy | Tank Cap., fl. oz. | Refrigerant No. | Features | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
For Closed-Loop Fluid Cooling Systems | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Thermoelectric Cooled | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
500 | Wire Leads | 24V DC | 12.5 | — | 1 gpm @ 10 psi | 20 | 50 to 140 | 9 1/16" | 5 1/8" | 6 5/16" | ±0.4% | 4 | — | Semi-Clear Tank Inlet | 0000000 | 000000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Refrigerant Cooled | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
3,400 | — | 120V AC (Single Phase) | 3.3 | 1/6 | 6 gpm @ 16 psi | 16 | 0 to 80 | 18 7/16" | 9 1/8" | 18 3/16" | ±1.8% | 51 | R-134A | UV Light System | 0000000 | 00000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||