About Liquid Chillers
More
Benchtop Liquid Chillers

Send cool water to equipment right from your bench top without compromising precision. These chillers maintain constant, uniform temperatures within 0.2° F where other chillers only keep liquid cool within a few full degrees. This makes them ideal for equipment where small temperature changes could cause an issue, such as microscope cooling plates.
Fill these chillers with water or glycol solutions, and an internal pump moves the liquid through a cooling system and out to your equipment. Use the built-in keypad to manually set the temperature, or connect an external controller of your own to automate temperature changes. View the set temperature, alerts, and other information from the LED display.
For technical drawings and 3-D models, click on a part number.
Overall | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Capacity, Btu/hr. | Voltage (Electrical Phase) | Current | Compressor Hp. | Max. Flow Rate | Max. Pressure, psi | Temp. Control Range, °F | Ht. | Wd. | Dp. | Accuracy | Tank Cap., fl. oz. | Refrigerant Number | Features | Each | |
For Closed-Loop Systems | |||||||||||||||
Compressor-Driven Cooling | |||||||||||||||
3,400 | 120V AC (Single) | 3.3A | 1/6 | 6 gpm @ 16 psi | 16 | 0° to 80° | 18 7/16" | 9 1/8" | 18 3/16" | ±1.8% | 51 | R-134A | UV Light System | 0000000 | 000000000 |
Rack-Mount Liquid Chillers

Save floor space—these chillers mount to standard 19" electronics racks, enclosures, and cabinets. Because they're so compact, you can even fit multiple chillers on the same rack. Where other chillers only keep liquid cool within a few full degrees, these chillers are highly precise, maintaining constant, uniform temperatures within 0.18° F. This makes them ideal for equipment where small temperature changes could cause an issue for your process. Also called Peltier chillers, they cool using only electricity, so there's no compressors or refrigerants. Without a compressor, you'll hardly hear them when they're running.
Fill these chillers with water or glycol solutions, and an internal pump moves the liquid through a cooling system and out to your equipment. There are multiple ways to control these chillers. Use the built-in keypad to manually set the temperature, or connect an external controller of your own to automate temperature changes. View the set temperature, pressure, and flow rate from the digital display. It will also display maintenance reminders and alarms.
A port on the front lets you quickly check fluid levels and fill the chiller with fluid without removing it from the rack or disconnecting it from your system.
For technical drawings and 3-D models, click on a part number.
Temp. Control | Overall | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Rack Wd. | Cooling Cap., Btu/hr. | Voltage (Electrical Phase) | Current | Max. Flow Rate | Max. Pressure, psi | Range, °F | Method | Ht. | Wd. | Dp. | Tank Cap., gal. | Each | |
For Closed-Loop Systems | |||||||||||||
Thermoelectric Cooling | |||||||||||||
19" | 600 | 100-240V AC (Single) | 2.5A | 0.8 gpm @ 5 psi | 10 | 50° to 140° | Keypad, External Controller | 7" | 19" | 13 1/2" | 0.3 | 0000000 | 000000000 |
Heat Sinks with Internal Pump for Water


To provide a more consistent flow of cooled water than other heat sinks for water, these have a built-in pump and reservoir. The internal fan-cooled heat exchanger dissipates heat. Btu/hr. cooling capacity is based on water with an initial temperature difference of 77° F.
For technical drawings and 3-D models, click on a part number.
Overall | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Cooling Cap., Btu/hr. | Pipe Size | Thread Type | Gender | Ht. | Wd. | Dp. | Heat Sink Material | Max. Pressure, psi | Max. Flow Rate, gpm | Max. Temp., °F | Voltage (Electrical Phase) | Current | NEMA Style | Cord Lg., ft. | Each | |
For Use with Water, Noncorrosive Liquids | ||||||||||||||||
12,000 | 1/2 | NPT | Female | 24" | 15" | 15" | Copper | 60 | 1.8 | 130° | 120V AC (Single) | 5.8A | 5-15 | 8 | 00000000 | 000000000 |