    Noncontact Liquid-Level Transmitters

    Use these transmitters to measure the levels of corrosive, dirty, or sticky liquids without coming into contact with them. They’ll continuously send measurements, so you can monitor status and manage components in your system. Mount at the top of your tank. There should be no tank walls, agitators, or other objects in the path of the transmitter.
    Ultrasonic
    Image of Product. Transmitter. Front orientation. Liquid-Level Transmitters. Noncontact Liquid-Level Transmitters, Ultrasonic.
    Image of Product. Front orientation. Liquid-Level Transmitters. Noncontact Liquid-Level Transmitters, Ultrasonic, Button Interface.

    Transmitter

    Button

    Interface

    Ultrasonic transmitters use high-frequency sound waves and are often used to measure water, wastewater, chemicals, and oil but won’t work on vapors, foam, and other media that’s difficult to measure. The included fob allows you to connect your transmitter to your computer, where you'll download software that guides you through the setup process to make sure you get accurate readings.
    Digital Switch Output—Transmitters with a switch can also signal your controller to turn components on or off when they reach a set level.
    NEMA 6P Enclosure Rating—NEMA 6P rated transmitters protect against dust, weather, washdowns, corrosion, and submersion. IP68 rated transmitters seal out dust and water from temporary submersion.
    Button Interface—Ultrasonic transmitters with a button interface can be set up and calibrated without the fob.
    Overall
    Pipe
    Size
    For Liquid
    Level, ft.
    Max. Pressure
    @ Temp.
    Dia.
    Lg.
    Temp. Range,
    ° F
    Cable Lg.,
    ft.
    Input Voltage,
    V DC
    Electrical Connection
    Enclosure
    Rating
    Includes
    Features
    Each
    NPT Male Pipe Connection
     
    4-20 mA Signal
    2
    0 to 19 1/230 psi @ 70° F4 3/8"7"-30 to 14014 to 28Quick-Disconnect TerminalIP68, NEMA 6P
    USB Configuration FobButton Interface3407K170000000
    3
    0 to 3930 psi @ 70° F4 5/8"7"-30 to 14014 to 28Quick-Disconnect TerminalIP68, NEMA 6P
    USB Configuration FobButton Interface3407K1800000000
     
    4 mA to 20 mA Signal with Switch
    2
    1 1/2 to 4 3/430 psi @ 70° F2 3/4"4"-30 to 140414 to 28Wire LeadsIP68, NEMA 6P
    USB Configuration Fob3407K15000000
    2
    4 to 9 3/430 psi @ 70° F2 3/4"4"-30 to 140414 to 28Wire LeadsIP68, NEMA 6P
    USB Configuration Fob3407K16000000
     
    Replacement USB Adapters for Ultrasonic Transmitters