McMaster-Carr logo
    Filter by
    Mounting Profile
    Environment
    Overall Depth
    Overall Width
    Frame Material
    Mounting Location
    Overall Height
    Blade Adjustability
    Water Penetration Rating
    Adjustability
    Depth
    Material
    Pressure Drop @ Water Penetration Rating
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Blade Finished Material
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    5 Products

    Weather-Resistant Fixed-Blade Wall-Mount Louvers

    Image of Product. Front orientation. Louvers. Weather-Resistant Fixed-Blade Wall-Mount Louvers.
    Designed with blades that drain water down the jambs, these louvers keep water from running down the front of the blades, even in harsh weather. All louvers have a seal of air performance and water penetration from Air Movement and Control Association (AMCA), so they’ve passed rigorous testing to ensure minimal airflow resistance, while preventing light rainfall from entering your duct system.
    Recessed Mount
    Image of Specification. Side1 orientation. Recessed Mount.

    Recessed

    Mount

    Wind-Driven Rain Environments—Wind-driven rain resistant louvers are AMCA Class A, which means they've achieved the highest rating when tested with strong winds and heavy rain.
    Water Penetration Rating—Water penetration rating is the air velocity at which water will start to pass through the louver. The higher the number, the better protected the louver is from rain.
    Pressure Drop @ Water Penetration Rating—Pressure drop is the amount of pressure lost as air passes through the louver into your system. The lower the pressure drop, the higher the airflow.
    Airflow—Airflow is the volume of air passing through the louver. Your louver should allow the necessary airflow required for your HVAC system.
    For
    Opening
    Overall
    Wd.
    Ht.
    Wd.
    Ht.
    Dp.
    Blade
    Thk.
    No. of
    Panels
    Water Penetration
    Rating, fpm
    Pressure Drop @ Water
    Penetration Rating, in. H₂O
    Airflow,
    scfm
    Includes
    Mounting Fasteners
    Included
    Certification
    Specs.
    Met
    AMCA Louver
    Rating
    Each
    Aluminum Frame and Blades
     
    Wind-Driven Rain Environments
    11 1/2"11 1/2"11"11"4"0.06"11,0790.41324Bird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration, AMCA Certified for Wind-Driven Rain
    AMCA 500-LClass A00000000000000
    13 1/2"13 1/2"13"13"4"0.06"11,0790.41378Bird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration, AMCA Certified for Wind-Driven Rain
    AMCA 500-LClass A0000000000000
    19 1/2"19 1/2"19"19"4"0.06"11,0790.411,026Bird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration, AMCA Certified for Wind-Driven Rain
    AMCA 500-LClass A0000000000000
    23 1/2"23 1/2"23"23"4"0.06"11,0790.411,835Bird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration, AMCA Certified for Wind-Driven Rain
    AMCA 500-LClass A0000000000000
    35 1/2"35 1/2"35"35"4"0.06"11,0790.414,587Bird ScreenNoAMCA Certified for Air Performance, AMCA Certified for Water Penetration, AMCA Certified for Wind-Driven Rain
    AMCA 500-LClass A0000000000000
     
    back to top