McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    26 Products

    Low-Maintenance Plastic Circulation Pumps for Water and Coolants

    Eliminate seal wear and leakage with pumps that use magnets to turn the impeller. They’re often used with electroplating and photographic solutions. Pumps are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps with Tube Connections (Top Intake)
    Image of Product. Front orientation. Centrifugal Pumps. Low-Maintenance Plastic Circulation Pumps for Water and Coolants, Pumps with Tube Connections (Top Intake).
    Flow
    Rate, gpm
    Intake
    Discharge
    Overall
    Max. Flow
    Rate, gpm
    @ 5 ft.
    of Head
    @ 10 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Connection
    Connection
    Type
    For Tube
    ID
    Connection
    Connection
    Type
    For Tube
    ID
    Lg.
    Wd.
    Ht.
    Each
    115V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    310.110.642035 to 1501/700.8Barbed
    Male Unthreaded1/2"Barbed
    Male Unthreaded1/2"6 3/4"3 3/4"4 7/8"9930K710000000
     
    Pumps with Tube Connections (Front Intake)
    Image of Product. Front orientation. Centrifugal Pumps. Low-Maintenance Plastic Circulation Pumps for Water and Coolants, Pumps with Tube Connections (Front Intake).
    Flow
    Rate, gpm
    Intake
    Discharge
    Overall
    Max. Flow
    Rate, gpm
    @ 5 ft.
    of Head
    @ 10 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Connection
    Connection
    Type
    For Tube
    ID
    Connection
    Connection
    Type
    For Tube
    ID
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    52732035 to 1501/500.94Barbed
    Male Unthreaded5/8"Barbed
    Male Unthreaded5/8"7 5/8"3 1/2"5 1/4"9930K370000000
    7751982035 to 1501/251.65Barbed
    Male Unthreaded5/8"Barbed
    Male Unthreaded5/8"8 1/4"3 1/2"5 1/4"9930K41000000
     
    Pumps with Pipe Connections (Front Intake)
    Image of Product. Front orientation. Centrifugal Pumps. Low-Maintenance Plastic Circulation Pumps for Water and Coolants, Pumps with Pipe Connections (Front Intake).
    Flow
    Rate, gpm
    Intake
    Discharge
    Overall
    Max. Flow
    Rate, gpm
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    Connection
    Connection
    Type
    Connection
    Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    115V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    95Not Rated16.172035 to 1501/201.4Threaded1/2 Female NPTThreaded1/2 Male NPT8 7/8"3 3/4"4 7/8"9930K720000000
    1411424.7102035 to 1501/101.7Threaded1 Female NPTThreaded1/2 Male NPT9 5/8"5 1/2"4 7/8"9930K73000000
     
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In
    8514.662035 to 1501/301.5Threaded1/2 Female NPTThreaded1/2 Male NPT8 1/2"4"4 3/8"9930K51000000
    118323.7102035 to 1501/122.4Threaded1/2 Female NPTThreaded1/2 Male NPT9"4"4 3/8"9930K53000000
    129221.992035 to 1501/122.4Threaded3/4 Female NPTThreaded1/2 Male NPT9 7/8"4"5"9930K63000000
    1512834.6152035 to 1501/82.1Threaded1/2 Female NPTThreaded1/2 Male NPT8 3/8"5 1/2"5 5/8"9930K54000000
    1713827.5112035 to 1501/82Threaded1 Female NPTThreaded1/2 Male NPT8 3/4"5 1/2"5 1/2"9930K65000000
     

    High-Flow Harsh-Environment Low-Maintenance Plastic Circulation Pumps for Water and Coolants

    Image of Product. Front orientation. Centrifugal Pumps. High-Flow Harsh Environment Low-Maintenance Plastic Circulation Pumps for Water and Coolants.
    A powerful motor provides twice the flow rate of other extended-life circulation pumps. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Magnets turn the impeller to eliminate seal wear and leakage for a long service life. These pumps are often used with electroplating and photographic solutions. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 20 ft.
    of Head
    @ 30 ft.
    of Head
    @ 40 ft.
    of Head
    @ 50 ft.
    of Head
    @ 60 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    120V AC/240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—9 cP Maximum Viscosity
    5341332816050351503/410 amp/5 amp1 1/2 Female NPT1 Male NPT17 7/8"9"9"9929K560000000009929K580000000
     
    Hardwire—20 cP Maximum Viscosity
    32251940.517351501/35 amp/2.5 amp1 Female NPT3/4 Male NPT16 1/4"8 7/8"7"99095K5400000000———0
    383228215121351501/29.4 amp/4.7 amp1 Female NPT3/4 Male NPT16 1/4"8 7/8"7"99095K5500000000———0
    534237281858.925351503/411.8 amp/5.9 amp1 1/2 Female NPT1 Male NPT17 1/4"8 5/8"8 1/2"99095K5700000000———0
     
    240V AC/460V AC, Three Phase—With Thermal Overload Protection
     
    Hardwire—20 cP Maximum Viscosity
    383228215121351501/21.8 amp/0.9 amp1 Female NPT3/4 Male NPT15 1/4"8 3/4"7"99095K5600000000———0
    534237281858.925351503/42.9 amp/1.5 amp1 1/2 Female NPT1 Male NPT17 1/4"8 5/8"8 5/8"99095K5800000000———0
     

    Harsh-Environment Low-Maintenance Plastic Circulation Pumps for Water and Coolants

    Image of Product. Front orientation. Centrifugal Pumps. Harsh Environment Low-Maintenance Plastic Circulation Pumps for Water and Coolants.
    These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. The impeller is turned with magnets to eliminate seal wear and leakage for a long service life. Pumps are often used with electroplating and photographic solutions. They are gravity fed and require an elevated liquid source to fully fill the pump before turning on. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Pumps
    Impellers
    Flow Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 5 ft.
    of Head
    @ 10 ft.
    of Head
    @ 20 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In—20 cP Maximum Viscosity
    10616.37351501/251.3 amp1/2 Female NPT1/2 Male NPT9"4"5"99095K510000000———0
    1412424.310351501/101.7 amp1 Female NPT1/2 Male NPT10 7/8"5 1/2"5"99095K52000000———0
     
    240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—20 cP Maximum Viscosity
    107516.37351501/200.8 amp1/2 Female NPT1/2 Male NPT8 1/2"4"4 3/8"9930K52000000———0
    1412424.310351501/100.7 amp1 Female NPT1/2 Male NPT10 5/8"5 1/2"5"9930K64000000———0
     
    120V AC/240V AC, Single Phase—With Thermal Overload Protection
     
    Hardwire—5 cP Maximum Viscosity
    181715112950351501/52.6 amp/1.3 amp1 Female NPT1/2 Male NPT12 1/4"7 1/4"7"9929K550000009929K570000000
     
    Plug In—20 cP Maximum Viscosity
    20171129.310351501/83 amp/1.4 amp1 Female NPT1/2 Male NPT11 1/4"5 1/4"7 3/8"9930K66000000———0
     

    Extended-Life Inline Circulation Pumps for Water

    Image of Product. Front orientation. Centrifugal Pumps. Extended-Life Inline Circulation Pumps for Water.
    Eliminate seal wear and leakage—these pumps have magnets that turn the impeller for a long service life. Install them directly in your pipeline for applications such as hot-water circulation and hydronic heating and cooling. Mount vertically or horizontally. Do not run dry or use with solids.
    Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
    Flow
    Rate, gpm
    Temp.,
    ° F
    Overall
    Max. Flow
    Rate, gpm
    @ 5 ft.
    of Head
    @ 10 ft.
    of Head
    Max. ft. of
    Head, ft.
    Max. Pressure,
    psi
    Min.
    Max.
    Power,
    hp
    Current
    Intake Connection
    Type
    Discharge Connection
    Type
    Lg.
    Wd.
    Ht.
    Each
    120V AC, Single Phase—With Thermal Overload Protection
     
    Plug In—1 cP Maximum Viscosity
    44.3150352501/1000.54 amp1/2 Male NPT1/2 Male NPT4 7/8"3 1/2"7 1/2"4161K110000000
    65312.1150352501/250.54 amp1/2 Male NPT1/2 Male NPT4 7/8"3 1/2"7 1/2"4161K21000000
     
    back to top