About Precision Flow-Adjustment Valves
More
Flow-Adjustment Valve Manifolds for Sealed Systems



A sealed design prevents contamination in dirty and dusty environments. Use these manifolds to serve multiple lubrication points from a single location. Adjust the flow to individual lubrication points by turning the dial on the corresponding valve. Each valve can be removed for cleaning without disturbing the rest of the system. They can be used with any oil grade. Flow rate depends on temperature. They have NPTF (Dryseal) threads, which are compatible with NPT threads.
For technical drawings and 3-D models, click on a part number.
Oil Outlet | Oil Inlet | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | For Tube OD | Gender | Location | Thread Type | Pipe Size | Gender | Ht. | Wd. | Dp. | Max. Oil Outlet Pressure, psi | Material | Temp. Range, °F | Mounting Thread Size | Features | Each | |
2 | 1/4" | Female | Top | NPTF | 1/4 | Female | 3 13/16" | 4 3/16" | 1 11/16" | 125 | Aluminum | -30° to 250° | 5/8"-18 | Glass Flow Sight | 0000000 | 0000000 |
3 | 1/4" | Female | Top | NPTF | 1/4 | Female | 3 13/16" | 4 15/16" | 1 11/16" | 125 | Aluminum | -30° to 250° | 5/8"-18 | Glass Flow Sight | 0000000 | 000000 |
4 | 1/4" | Female | Top | NPTF | 1/4 | Female | 3 13/16" | 5 11/16" | 1 11/16" | 125 | Aluminum | -30° to 250° | 5/8"-18 | Glass Flow Sight | 0000000 | 000000 |
Flow-Adjustment Valve Manifolds for Vented Systems



For use in clean environments, these manifolds have multiple air vents that keep pressure balanced. Use them to serve multiple lubrication points from a single location. Adjust the flow to individual lubrication points by turning the dial on the corresponding valve. Each valve can be removed for cleaning without disturbing the rest of the system. They can be used with any oil grade. Flow rate depends on temperature. They have NPTF (Dryseal) threads, which are compatible with NPT threads.
For technical drawings and 3-D models, click on a part number.
Oil Outlet | Oil Inlet | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | For Tube OD | Gender | Location | Thread Type | Pipe Size | Gender | Ht. | Wd. | Dp. | Material | Temp. Range, °F | Mounting Thread Size | Features | Each | |
2 | 1/4" | Female | Top | NPTF | 1/4 | Female | 3 13/16" | 4 3/16" | 1 11/16" | Aluminum | -30° to 250° | 5/8"-18 | Glass Flow Sight | 0000000 | 0000000 |
3 | 1/4" | Female | Top | NPTF | 1/4 | Female | 3 13/16" | 4 15/16" | 1 11/16" | Aluminum | -30° to 250° | 5/8"-18 | Glass Flow Sight | 0000000 | 000000 |
4 | 1/4" | Female | Top | NPTF | 1/4 | Female | 3 13/16" | 5 11/16" | 1 11/16" | Aluminum | -30° to 250° | 5/8"-18 | Glass Flow Sight | 0000000 | 000000 |
Oil Manifolds




Deliver an equal amount of oil to multiple lubrication points at once. They come with tubing to access hard-to-reach areas. These manifolds can be used with any oil grade.
Oil Outlet | Oil Inlet | Overall | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of | Thread Type | Pipe Size | Gender | No. of | Thread Type | Pipe Size | Gender | Ht. | Wd. | Dp. | Flow Rate, oz./min. | Max. Oil Outlet Pressure, psi | Mounting Fasteners Included | Includes | Each | |
4 | NPT | 1/8 | Female | 1 | NPT | 1/8 | Female | 1 15/16" | 3 1/8" | 2 5/16" | 2 | 2,130 | Yes | 6 ft. of Nylon Tubing per Outlet, Two Brass Tube Fittings for 1/4" OD Tube per Outlet, Two Steel Tube Clamps with Mounting Screws per Outlet | 000000 | 0000000 |
6 | NPT | 1/8 | Female | 1 | NPT | 1/8 | Female | 1 15/16" | 3 5/16" | 2 5/16" | 3 | 2,130 | Yes | 6 ft. of Nylon Tubing per Outlet, Two Brass Tube Fittings for 1/4" OD Tube per Outlet, Two Steel Tube Clamps with Mounting Screws per Outlet | 000000 | 000000 |
8 | NPT | 1/8 | Female | 1 | NPT | 1/8 | Female | 1 15/16" | 3 5/16" | 2 5/16" | 4 | 2,130 | Yes | 6 ft. of Nylon Tubing per Outlet, Two Brass Tube Fittings for 1/4" OD Tube per Outlet, Two Steel Tube Clamps with Mounting Screws per Outlet | 000000 | 000000 |
12 | NPT | 1/8 | Female | 1 | NPT | 1/8 | Female | 2 7/16" | 3 5/16" | 2 7/16" | 6 | 2,130 | Yes | 6 ft. of Nylon Tubing per Outlet, Two Brass Tube Fittings for 1/4" OD Tube per Outlet, Two Steel Tube Clamps with Mounting Screws per Outlet | 000000 | 000000 |
Metering Valves for Oil-Dispensing Pumps

Use these valves with manual and electric pumps to dispense different amounts of oil from multiple lubrication points. They have a check valve to prevent backward flow. To connect to tubing, use a compression nut and sleeve (sold separately).
Flow rate trade number indicates the relative amount of oil each valve delivers. For each increase in trade size, the amount of oil delivered approximately doubles. For example, 0 delivers twice the amount of oil that 00 delivers. In a system with two lubrication points, the lubrication point connected to 0 will receive 2/3 of the oil dispensed, and the lubrication point connected to 00 will receive 1/3 of the oil dispensed. In general, valves with lower relative flow rates are better for cycling systems; valves with higher relative flow rates are better for continuous recirculation systems.
Oil Outlet | Oil Inlet | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Thread Type | Pipe Size | Thread Size | Gender | Thread Type | Pipe Size | Thread Size | Gender | Max. Oil Outlet Pressure, psi | Lg. | Hex Wd., mm | Material | Temp. Range, °F | Choose a Flow Rate Trade Number | Each | |
NPT | 1/8 | __ | Male | NPT | 1/8 | __ | Male | 200 | 1" | 10 | Brass | 32° to 120° | 0000000 | 000000 | |
NPT | 1/8 | __ | Male | UNF | __ | 5/16"-24 | Male | 200 | 1" | 10 | Brass | 32° to 120° | 0000000 | 00000 | |
UNF | __ | 5/16"-24 | Male | UNF | __ | 5/16"-24 | Male | 200 | 1" | 10 | Brass | 32° to 120° | 0000000 | 00000 |
High-Pressure Threaded Precision Flow-Adjustment Manifolds

- Valve Type: Needle
- For Use With: See table
- Seal Material: Fluoroelastomer Rubber
Often attached to differential pressure gauges to measure liquid level in tanks, these manifolds have two isolation valves with a pressure-equalizing valve between them. To isolate your differential pressure gauge for maintenance or calibration, shut off flow on both sides and equalize pressure in the manifold. All manifolds have a 316 stainless steel body for excellent corrosion resistance.
Metal-to-metal seats resist temperature fluctuations.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open manifold with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | End-to-End Lg. | For Use With | Each | |
Nickel-Plated and Zinc-Plated 316 Stainless Steel Body—Metal-to-Metal Seat | ||||||
---|---|---|---|---|---|---|
NPT Female × NPT Female | ||||||
1/2 | 0.44 | 10000 psi @ 200° F | 2 7/8" | Water, Oil, Air, Argon, Helium, Krypton, Neon, Xenon | 0000000 | 0000000 |
High-Pressure Threaded Precision Flow-Adjustment Valves with Vent Ports

- Valve Type: Needle
- For Use With: Water, Oil, Air, Argon, Helium, Krypton, Neon, Xenon
Also known as block and bleed valves, these have two vent ports to isolate pressure gauges, switches, and other components in high-pressure systems for maintenance, calibration, and sampling without interrupting the process. Turn the handle to adjust flow in small increments for metering, sampling, and other applications requiring fine flow control. All valves have metal-to-metal seats that resist temperature fluctuations. Body is 316 stainless steel for excellent corrosion resistance. Valves have a nut that can be tightened to compress the packing if it leaks.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Threaded Precision Flow-Adjustment Valves with Gauge Ports

- Valve Type: Needle
- For Use With: See table
- Seal Material: Fluoroelastomer Rubber
With a gauge port on each side of these valves, you can install two pieces of instrumentation equipment to simultaneously monitor multiple media properties without interrupting flow. Turn the handle to adjust flow in small increments for metering, sampling, and other applications requiring fine flow control. Valves have a 316 stainless steel body for excellent corrosion resistance.
Metal-to-metal seats resist temperature fluctuations.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Gauge Ports | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | No. of | Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | End-to-End Lg. | For Use With | Each | |
Steel Body—Metal-to-Metal Seat | ||||||||||
NPT Male × NPT Female | ||||||||||
1/2 × 1/2 | 2 | 1/2 | Female | NPT | 0.44 | 10000 psi @ 200° F | 5 3/8" | Oil, Air, Argon, Helium, Krypton, Neon, Xenon | 0000000 | 0000000 |
3/4 × 1/2 | 2 | 1/2 | Female | NPT | 0.44 | 10000 psi @ 200° F | 5 3/8" | Oil, Air, Argon, Helium, Krypton, Neon, Xenon | 0000000 | 000000 |
316 Stainless Steel Body—Metal-to-Metal Seat | ||||||||||
NPT Male × NPT Female | ||||||||||
1/2 × 1/2 | 2 | 1/2 | Female | NPT | 0.44 | 10000 psi @ 200° F | 5 3/8" | Water, Oil, Air, Argon, Helium, Krypton, Neon, Xenon | 0000000 | 000000 |
3/4 × 1/2 | 2 | 1/2 | Female | NPT | 0.44 | 10000 psi @ 200° F | 5 3/8" | Water, Oil, Air, Argon, Helium, Krypton, Neon, Xenon | 0000000 | 000000 |
Threaded Precision Flow-Adjustment Valves with Vent Port


- Valve Type: Needle
- For Use With: See table
- Seal Material: Fluoroelastomer Rubber
Also known as block and bleed valves, these have a vent port that allows you to remove instrumentation equipment attached to the valve without depressurizing your line. Turn the handle to shut off flow and remove the vent port plug to drain liquid trapped in the valve. Valves adjust flow in small increments for metering, sampling, and other applications requiring fine flow control.
316 stainless steel valves are more corrosion resistant than steel valves.
Metal-to-metal seats resist temperature fluctuations.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
For technical drawings and 3-D models, click on a part number.
Pipe Size | Flow Coefficient (Cv) | Max. Pressure | End-to-End Lg. | For Use With | Each | |
316 Stainless Steel Body—Metal-to-Metal Seat | ||||||
---|---|---|---|---|---|---|
NPT Female × NPT Female | ||||||
1/4 | 0.44 | 10000 psi @ 200° F | 2 1/2" | Water, Oil, Air, Argon, Helium, Krypton, Neon, Xenon | 0000000 | 0000000 |
1/2 | 0.44 | 10000 psi @ 200° F | 2 1/2" | Water, Oil, Air, Argon, Helium, Krypton, Neon, Xenon | 0000000 | 000000 |
NPT Female × NPT Male | ||||||
1/4 | 0.44 | 10000 psi @ 200° F | 3 1/2" | Water, Oil, Air, Argon, Helium, Krypton, Neon, Xenon | 0000000 | 000000 |
1/2 | 0.44 | 10000 psi @ 200° F | 3 1/2" | Water, Oil, Air, Argon, Helium, Krypton, Neon, Xenon | 0000000 | 000000 |
Carbon Steel Body—Metal-to-Metal Seat | ||||||
NPT Female × NPT Female | ||||||
1/4 | 0.44 | 10000 psi @ 200° F | 2 1/2" | Oil, Air, Argon, Helium, Krypton, Neon, Xenon | 0000000 | 00000 |
1/2 | 0.44 | 10000 psi @ 200° F | 2 1/2" | Oil, Air, Argon, Helium, Krypton, Neon, Xenon | 0000000 | 00000 |
NPT Female × NPT Male | ||||||
1/4 | 0.44 | 10000 psi @ 200° F | 3 1/2" | Oil, Air, Argon, Helium, Krypton, Neon, Xenon | 0000000 | 00000 |
1/2 | 0.44 | 10000 psi @ 200° F | 3 1/2" | Oil, Air, Argon, Helium, Krypton, Neon, Xenon | 0000000 | 00000 |