    Cable-Pull Switches

    Image of Product. Front orientation. Pull Switches. Cable-Pull Switches, 1 Direction.

    1 Direction

    Connect these switches to a cable to control circuits from a distance. They're typically used to turn off production lines and material handling systems. Mount in any position and tug on the cable to send a switching signal. Equipment will not start up again until the switch is manually reset.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Actuation
    Force, lbf
    Conduit
    Trade Size
    Mounting Fasteners
    Included
    Each
    Screw-Terminal Wire Connection
     
    1 Direction (NEMA 1)
    11 On
    Maintained
    2SPST-NC
    6 amp @ 120V AC, 3 amp @ 240V AC, 0.6 amp @ 125V DC600V AC
    600V DC
    2 to 61/2
    Yes7186K530000000
     

    Enclosed Motor Switches

    Image of Product. Front orientation. Motor Switches. Enclosed Motor Switches.
    These switches are housed in a plastic enclosure. Since they’re already protected, you can mount them to a wall if there’s no space left in your electrical panel. You can also turn them into a handheld control and move them around your workstation by attaching a cord and cord grip. The enclosure is plastic, so it won’t swell in moist environments. Easy to operate even if you’re wearing gloves, flip the toggle switch up and down. Use these switches to turn motors on and off, or with lighting and electric heat circuits. They do not provide overload protection.
    Switching
    No. of Circuits
    Controlled
    Electrical Phase (hp)
    Switch Starting
    Position
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Housing
    Material
    Ht.
    Wd.
    Wire
    Connection
    Environment
    Enclosure
    Rating
    Certification
    Each
    Maintained
     
    Toggle Switch Actuator
    2Single (3 hp @ 240V AC)2 Off
    DPST-NO
    30600Plastic4.2"2.8"Screw TerminalIndoor OnlyNEMA 1
    UL Listed, CSA Certified
    7657K31000000
    2Single (5 hp @ 240V AC)2 Off
    DPST-NO
    60600Plastic4.5"4.7"Screw TerminalIndoor OnlyNEMA 1
    UL Listed, CSA Certified
    7657K36000000
    3Three (7 1/2 hp @ 240V AC)3 Off
    3PST-NO
    30600Plastic4.2"2.8"Screw TerminalIndoor OnlyNEMA 1
    UL Listed, CSA Certified
    7657K21000000
    3Three (10 hp @ 240V AC)3 Off
    3PST-NO
    60600Plastic4.5"4.7"Screw TerminalIndoor OnlyNEMA 1
    UL Listed, CSA Certified
    7657K26000000
     

    Reversing Motor Switches

    Image of Product. With Powder-Coated Steel Enclosure. Front orientation. Motor Switches. Reversing Motor Switches, Powder-Coated Steel Housing.
    Image of Product. With Plastic Enclosure. Front orientation. Motor Switches. Reversing Motor Switches, Plastic Housing.

    With Powder-Coated

    Steel Enclosure

    With Plastic

    Enclosure

    Use these switches to control the on/off function of motors that run forward and backward, such as motors for conveyor belts. They can also be used with other circuits such as lighting and electric heat circuits, but do not provide overload protection. Also known as drum switches.
    Maintained/Momentary—Switches that have maintained/momentary switch action are supplied to stay switched (maintained), but can be wired to spring back (momentary).
    Electrical Phase (hp)
    Housing Material
    Ht.
    Wd.
    Wire
    Connection
    Environment
    Enclosure
    Rating
    Certification
    Each
    Maintained
    Single (1 1/2 hp @ 115V AC)Powder-Coated Steel4.5"2.4"Screw TerminalIndoor OnlyNEMA 1
    UL Listed, CSA Certified
    7065K21000000
    Single (1 1/2 hp @ 115V AC)
    Three (2 hp @ 230V AC)
    Three (1 hp @ 440V AC)
    Powder-Coated Steel4.5"2.4"Screw TerminalIndoor OnlyNEMA 1
    UL Listed, CSA Certified
    7065K23000000
    Single (1 1/2 hp @ 115V AC)
    Three (2 hp @ 230V AC
    Three (2 hp @ 440V AC)
    Plastic5.3"2.5"Screw TerminalIndoor OnlyNEMA 1
    UL Listed, CSA Certified
    7826K22000000
    Single (2 hp @ 115V AC)
    Three (5 hp @ 230V AC)
    Three (7 1/2 hp @ 440V AC)
    Powder-Coated Steel6.5"3.5"Screw TerminalIndoor OnlyNEMA 1
    UL Listed, CSA Certified
    7065K25000000
     
    Momentary
    Single (1 1/2 hp @ 115V AC)
    Three (2 hp @ 230V AC)
    Three (1 hp @ 440V AC)
    Powder-Coated Steel4.5"2.4"Screw TerminalIndoor OnlyNEMA 1
    UL Listed, CSA Certified
    7065K22000000
     
    Maintained/Momentary
    Single (1 1/2 hp @ 115V AC)
    Three (3 hp @ 230V AC)
    Three (3 hp @ 440V AC)
    Powder-Coated Steel4.75"3.2"Screw TerminalIndoor OnlyNEMA 1
    UL Listed, CSA Certified
    7826K24000000
    Single (2 hp @ 115V AC)
    Three (5 hp @ 230V AC)
    Three (7 1/2 hp @ 440V AC)
    Powder-Coated Steel4.75"3.2"Screw TerminalIndoor OnlyNEMA 1
    UL Listed, CSA Certified
    7826K25000000
     

    Build-Your-Own Manual Motor Starters

    Assemble your own motor starter by combining a switch and a thermal overload element.
    Thermal overload elements shut motors off if current exceeds the full-load current rating. Three elements are required. To Order: Please specify the full-load current rating of your motor. If the full-load current rating is not shown on the motor’s faceplate, estimate the current rating (given the motor’s power and voltage).
    Switches with Power-Indicating Light
    Image of Product. Front orientation. Motor Starters. Build-Your-Own Manual Motor Starters, Switches with Power-Indicating Light, Steel Housing.

    Steel Housing

    No. of Circuits
    Controlled
    Electrical Phase
    Ht.
    Wd.
    Wire
    Connection
    Enclosure
    Rating
    Environment
    Each
    Steel Housing
    1Single (1 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    4.3"2.8"Screw TerminalNEMA 1
    Indoor Only7254K270000000
    2Single (3/4 hp @ 115V DC)
    Single (3/4 hp @ 230V DC)
    Single (1 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    4.3"2.8"Screw TerminalNEMA 1
    Indoor Only7254K37000000
     
    Switches without Power-Indicating Light
    Image of Product. Front orientation. Motor Starters. Build-Your-Own Manual Motor Starters, Switches, Steel Housing.

    Steel Housing

    No. of Circuits
    Controlled
    Electrical Phase
    Ht.
    Wd.
    Wire
    Connection
    Enclosure
    Rating
    Environment
    Each
    Steel Housing
    1Single (1 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    4.3"2.8"Screw TerminalNEMA 1
    Indoor Only7254K23000000
    2Single (3/4 hp @ 115V DC)
    Single (3/4 hp @ 230V DC)
    Single (1 hp @ 115V AC)
    Single (1 hp @ 230V AC)
    4.3"2.8"Screw TerminalNEMA 1
    Indoor Only7254K33000000
     

    Cable-Pull-Actuator Emergency Stop Switches with Restart Switch

    Tug the cable to stop your line, then follow it back to the restart switch. Typically separate devices, the stop and reset controls are in one compact unit. As a secondary shutdown option, a push-button stop switch is also built in. A secondary push-button stop switch ensures you can halt equipment immediately, even when the cable is out of reach. Because they let you control circuits from a distance with a quick tug, these cable-pull stop switches are often used to turn off production lines and material handling systems. To notify your team on the floor that you’ve stopped equipment, a power indicator lights up when you pull the cable.
    Use the tension indicator to confirm that cable is set up correctly. Circuits remain open until you tension the cable and hit the restart button. Cable is not included.
    1 Direction
    Image of Product. Left Side Cable Location. Front orientation. Emergency Stop Switches. Cable-Pull-Actuator Emergency Stop Switches with Restart Switch, 1 Direction, Tension Indicator, Power Indicator, Restart Button, Emergency Stop Button, Left-Side Cable.
    Image of Product. Right Side Cable Location. Front orientation. Emergency Stop Switches. Cable-Pull-Actuator Emergency Stop Switches with Restart Switch, 1 Direction, Tension Indicator, Power Indicator, Restart Button, Emergency Stop Button, Right-Side-Cable.

    Left Side Cable

    Location

    Right Side Cable

    Location

    Mounting
    Cable
    Location
    For Max.
    Cable Lg., ft.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    No. of
    Terminals
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage
    Actuation
    Force, lbf
    Conduit
    Trade Size
    Bulb
    Voltage
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Each
    Screw-Terminal Wire Connection
     
    With Emergency Stop Button, Power Indicator, Restart Button, Tension Indicator (IP54, NEMA 1)
    Left Side32522 Off or 2 On
    6DPDT
    6 amp @ 120V AC
    2.8 amp @ 24V DC
    240V AC
    24V DC
    111/2
    24V DCNo41/4"5746N301000000000
    Left Side32522 Off or 2 On
    6DPDT
    6 amp @ 120V AC
    2.8 amp @ 24V DC
    240V AC
    24V DC
    111/2
    120V ACNo41/4"5746N20100000000
    Right Side32522 Off or 2 On
    6DPDT
    6 amp @ 120V AC
    2.8 amp @ 24V DC
    240V AC
    24V DC
    111/2
    24V DCNo41/4"5746N1100000000
    Right Side32522 Off or 2 On
    6DPDT
    6 amp @ 120V AC
    2.8 amp @ 24V DC
    240V AC
    24V DC
    111/2
    120V ACNo41/4"5746N20200000000
     
    2 Directions
    Image of Product. Front orientation. Emergency Stop Switches. Cable-Pull-Actuator Emergency Stop Switches with Restart Switch, 2 Directions.
    Two-direction switches support twice the total cable distance of one-direction switches. With pulls on each side, you can route cable in two opposite directions. These switches are often placed at the midpoint of conveyors and other long runs of equipment.
    Mounting
    Cable Location
    For Max.
    Cable Lg., ft.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    No. of
    Terminals
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage
    Actuation
    Force, lbf
    Conduit
    Trade Size
    Bulb
    Voltage
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Each
    Screw-Terminal Wire Connection
     
    With Emergency Stop Button, Power Indicator, Restart Button, Tension Indicator (IP54, NEMA 1)
    Left Side, Right Side32522 Off or 2 On
    6DPDT
    6 amp @ 120V AC
    2.8 amp @ 24V DC
    240V AC
    24V DC
    111/2
    24V DCNo41/4"5746N12000000000
    Left Side, Right Side32522 Off or 2 On
    6DPDT
    6 amp @ 120V AC
    2.8 amp @ 24V DC
    240V AC
    24V DC
    111/2
    120V ACNo41/4"5746N204000000
     

    Enclosed Heavy Duty Build-Your-Own Manual Motor Starters

    Image of Product. Thermal Overload Protectors. Front orientation. Motor Starters. Enclosed Heavy Duty Build-Your-Own Manual Motor Starters.
    Image of Product. Switch with NEMA 1 Enclosure Rating. Front orientation. Motor Starters. Enclosed Heavy Duty Build-Your-Own Manual Motor Starters, NEMA 1 Enclosure Rating.

    Thermal

    Overload

    Protectors

    Switch with NEMA

    1 Enclosure

    Rating

    Combine a switch with a thermal overload element to build a starter that can handle high-current-rated motors. All are housed in a durable steel enclosure. They’re also known as NEMA starters.
    Thermal overload elements shut motors off if current exceeds the full-load current rating. Three elements are required. To Order: Please specify the full-load current rating of your motor. If the full-load current rating is not shown on the motor’s faceplate, estimate the current rating (given the motor’s power and voltage).
    Switches
    Thermal
    Overload Elements
    NEMA Contact
    Size
    Electrical Phase
    Housing
    Material
    Ht.
    Wd.
    Dp.
    Wire
    Connection
    Certification
    Each
    Each
    NEMA 1 Enclosure Rating
    M-0Three (2 hp @ 115V AC)
    Three (3 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Painted Steel7.6"4.7"5"Screw TerminalUL Listed, CSA Certified
    7595K6200000007595K2000000
    M-1Three (3 hp @ 115V AC)
    Three (7 1/2 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Painted Steel7.6"4.7"5"Screw TerminalUL Listed, CSA Certified
    7595K26000000007595K200000
     

    Manual Transfer Switches

    Image of Product. Front orientation. Transfer Switches. Manual Transfer Switches, NEMA 1.
    Image of Product. Front orientation. Transfer Switches. Manual Transfer Switches, NEMA 1 with NEMA 3R Power Inlet Box.

    NEMA 1

    NEMA 1 with NEMA 3R

    Power Inlet Box

    If there’s a power outage, flip the toggle for each circuit on these switches to backup power. Each circuit can also be turned off completely. To prevent injury and damage to your generators, they are open transition, meaning the contacts disconnect from one power source before connecting to another. This is also known as break-before-make switching.
    Use them with a portable generator.
    NEMA 1—NEMA 1 switches should be used indoors.
    NEMA 1 with NEMA 3R Power Inlet Box—NEMA 1 switches with a power inlet box create a connection point between the switch and a portable generator. These switches should be used indoors. But their inlet box is rated NEMA 3R, so it can be mounted on the outside of an exterior wall.
    Housing
    Mounting
    Max. Power,
    W
    Switching Current
    (No. of Switches)
    Circuit Breaker Breakthrough
    Current, amp
    Electrical
    Phase
    Housing Material
    Ht.
    Wd.
    Dp.
    Generator Connection
    NEMA Type
    Power Cord
    Lg., ft.
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Certification
    Specs. Met
    Each
    NEMA 1
     
    10 Circuits Controlled
    7,50030 amp @ 240V AC (1 DPDT)
    20 amp @ 240V AC (1 DPDT)
    15 amp @ 120V AC (6 SPDT)
    10,000SinglePowder-Coated Steel11 1/4"11 3/4"4 3/4"L14-30
    Yes51/4"UL Listed
    UL 1008, NEC Article 7024272N180000000
     
    NEMA 1 with NEMA 3R Power Inlet Box
     
    6 Circuits Controlled
    7,50020 amp @ 240V AC (1 DPDT)
    15 amp @ 120V AC (4 SPDT)
    10,000SinglePowder-Coated Steel12"8 3/4"6"L14-30
    10Yes51/4"UL Listed
    UL 1008, NEC Article 7024272N11000000
     
    10 Circuits Controlled
    7,50020 amp @ 240V AC (1 DPDT)
    20 amp @ 120V AC (2 SPDT)
    15 amp @ 120V AC (6 SPDT)
    10,000SinglePowder-Coated Steel11 1/4"11 3/4"4 3/4"L14-30
    10Yes51/4"UL Listed
    UL 1008, NEC Article 7024272N12000000
     

    Enclosed Heavy Duty Motor Starters

    Image of Product. Front orientation. Motor Starters. Enclosed Heavy Duty Motor Starters.
    Housed in a durable steel enclosure, these starters have sealed coils for protection against moisture, heat, dirt, and mechanical and thermal stress. They have a solid state overload relay that extends motor life in demanding applications and protects it from overloads—starters will shut the motor off if current exceeds the full-load current rating. The relay is adjustable; set it for the exact overload current needed. All have auxiliary contacts to send a signal or connect to another device, such as an alarm or indicating light. Also known as NEMA starters.
    Note: The full-load current rating of your motor must fall within the starter’s overload current range. Match input voltage, also known as coil voltage, to your control circuit; motor voltage may be different. Look for the full-load current rating on the motor’s faceplate, or estimate the current rating (given the motor’s power and voltage).
    NEMA Contact Size 0 and NEMA Contact Size 1—NEMA contact sizes 0 and 1 are universal mount and fit Cutler-Hammer, GE, and Square D installations.
    Motor Starters
    Replacement
    Coils
    Overload Current,
    amp
    Input Voltage,
    V AC
    Electrical Phase
    Tripping
    Accuracy
    Ht.
    Wd.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Each
    Motor Starters with 1 Auxiliary Contact—1 Off
     
    NEMA Contact Size 0
    0.25 to 124Three (1/6 hp @ 200V AC)
    Three (1/6 hp @ 230V AC)
    Three (1/3 hp @ 460V AC)
    Three (1/2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K34100000007463K7110000000
    0.25 to 1110/240Three (1/6 hp @ 200V AC)
    Three (1/6 hp @ 230V AC)
    Three (1/3 hp @ 460V AC)
    Three (1/2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K3420000007463K712000000
    0.25 to 1208Three (1/6 hp @ 200V AC)
    Three (1/6 hp @ 230V AC)
    Three (1/3 hp @ 460V AC)
    Three (1/2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K3430000007463K713000000
    0.75 to 3.424Three (1/2 hp @ 200V AC)
    Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 460V AC)
    Three (2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K3510000007463K711000000
    0.75 to 3.4110/240Three (1/2 hp @ 200V AC)
    Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 460V AC)
    Three (2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K3520000007463K712000000
    0.75 to 3.4208Three (1/2 hp @ 200V AC)
    Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 460V AC)
    Three (2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K3530000007463K713000000
    0.75 to 3.4220/480Three (1/2 hp @ 200V AC)
    Three (3/4 hp @ 230V AC)
    Three (1 1/2 hp @ 460V AC)
    Three (2 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K3540000007463K714000000
    3 to 1224Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4210000007463K711000000
    3 to 12110/240Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4220000007463K712000000
    3 to 12208Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4230000007463K713000000
    3 to 12220/480Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4240000007463K714000000
    5.5 to 2224Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4310000007463K711000000
    5.5 to 22110/240Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4320000007463K712000000
    5.5 to 22208Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4330000007463K713000000
    5.5 to 22220/480Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4340000007463K714000000
     
    NEMA Contact Size 1
    3 to 1224Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4510000007463K711000000
    3 to 12110/240Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4520000007463K712000000
    3 to 12208Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4530000007463K713000000
    3 to 12220/480Three (2 hp @ 200V AC)
    Three (2 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Three (5 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4540000007463K714000000
    5.5 to 2224Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Three (10 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4610000007463K711000000
    5.5 to 22110/240Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Three (10 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4620000007463K712000000
    5.5 to 22208Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Three (10 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4630000007463K713000000
    5.5 to 22220/480Three (3 hp @ 200V AC)
    Three (3 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Three (10 hp @ 575V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4640000007463K714000000
    10 to 4024Three (7 1/2 hp @ 200V AC)
    Three (7 1/2 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4710000007463K711000000
    10 to 40110/240Three (7 1/2 hp @ 200V AC)
    Three (7 1/2 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4720000007463K712000000
    10 to 40208Three (7 1/2 hp @ 200V AC)
    Three (7 1/2 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4730000007463K713000000
    10 to 40220/480Three (7 1/2 hp @ 200V AC)
    Three (7 1/2 hp @ 230V AC)
    -1% to 1%11"6.4"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K4740000007463K714000000
     
    NEMA Contact Size 2
    13 to 5224Three (10 hp @ 200V AC)
    Three (15 hp @ 230V AC)
    Three (25 hp @ 460V AC)
    Three (25 hp @ 575V AC)
    -1% to 1%13.5"8"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K521000000007463K711000000
    13 to 52110/240Three (10 hp @ 200V AC)
    Three (15 hp @ 230V AC)
    Three (25 hp @ 460V AC)
    Three (25 hp @ 575V AC)
    -1% to 1%13.5"8"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K522000000007463K712000000
    13 to 52208Three (10 hp @ 200V AC)
    Three (15 hp @ 230V AC)
    Three (25 hp @ 460V AC)
    Three (25 hp @ 575V AC)
    -1% to 1%13.5"8"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K523000000007463K713000000
    13 to 52220/480Three (10 hp @ 200V AC)
    Three (15 hp @ 230V AC)
    Three (25 hp @ 460V AC)
    Three (25 hp @ 575V AC)
    -1% to 1%13.5"8"NEMA 1
    UL Listed, C-UL Listed, CSA Certified
    UL 5087463K524000000007463K714000000
     