About Hazardous Location Environmental Ratings
More
About Motor Switches and Starters
More
Choosing an Electrical Switch
More
Hazardous Location Enclosed Push-Button Switches




Use these switches where ignitable gas and dust may be present. They're rated for use in hazardous locations.
For technical drawings and 3-D models, click on a part number.
Mounting | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Message (Actuator Color) | No. of Circuits Controlled per Button | Switch Starting Position | Switch Action | No. of Terminals per Button | Industry Designation | Switching Current @ Voltage | Max. Voltage | Conduit Trade Size | Fasteners Included | No. of Holes | Hole Dia. | Each | |
With Screw Terminals | |||||||||||||
1 Flush Button | |||||||||||||
Start (Black) | 1 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 4 | DPST-1NO/1NC | 10 A @ 120 V AC | 600V AC | 3/4 | No | 2 | 5/16" | 0000000 | 0000000 |
1 Flush Button and 1 Projecting Button | |||||||||||||
Start (Green), Stop (Red) | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Springs Back (Momentary) | 2 | DPST-1NO/1NC | 10 A @ 120 V AC | 600V AC | 3/4 | No | 2 | 9/32" | 0000000 | 000000 |
Hazardous Location Foot Switches


These switches are rated for environments where hazardous material is present. Press the pedal with your foot for hands-free operation. They have an oversized guard that accommodates bulky footwear.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
Mounting | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Switch Starting Position | Switch Action | Industry Designation | Switching Current @ Voltage | Fasteners Included | No. of Holes | Hole Dia. | Environmental Rating | Each | |
1 Speed with Screw Terminals | ||||||||||
Aluminum Housing with 1 Pedal, Oversized Guard, and Back Pivot | ||||||||||
1 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | SPDT | 20 A @ 125 V AC/250 V AC | No | 6 | 0.28" | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups F, G NEC Zone 1 Group IIA IP41 NEMA 2 NEMA 7 NEMA 9 | 0000000 | 0000000 |
2 | 2 Off (Normally Open) or 2 On (Normally Closed) | Springs Back (Momentary) | DPDT | 20 A @ 125 V AC/250 V AC | No | 6 | 0.28" | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups F, G NEC Zone 1 Group IIA IP41 NEMA 2 NEMA 7 NEMA 9 | 0000000 | 000000 |
Aluminum Housing with 2 Pedals, Oversized Guard, and Back Pivot | ||||||||||
2 | 1 Off (Normally Open) or 1 On (Normally Closed) | Springs Back (Momentary) | SPDT | 20 A @ 125 V AC/250 V AC | No | 6 | 0.28" | NEC Class I Divisions 1, 2 Group D NEC Class II Divisions 1, 2 Groups F, G NEC Zone 1 Group IIA IP41 NEMA 2 NEMA 7 NEMA 9 | 0000000 | 000000 |
Hazardous Location Cable-Pull Emergency Stop Switches

Safe to use near ignitable gases and dust, the housing on these switches seals in anything that could ignite flammable material. All are UL listed and CSA certified for use in hazardous locations. Yank the cable anywhere along your line to quickly cut power in emergencies. They have positive-force, snap-open contacts that open a circuit when actuated, even if a spring fails or the contacts stick. The contacts will remain open until you tension the cable and reset the switch. Use the tension indicator to visually confirm that they’re reset correctly.
For technical drawings and 3-D models, click on a part number.
Mounting | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Max. Cable Lg., ft. | No. of Circuits Controlled | Switch Starting Position | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Actuation Force, lbs. | Conduit Trade Size | Fasteners Included | Hole Dia. (No. of Holes) | Hole Thread Size (No. of Holes) | Features | Each | |
With Screw Terminals | ||||||||||||||
1 Direction (NEMA 4; NEMA 7; NEMA 9; NEMA 13; NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G) | ||||||||||||||
200 | 1 | 1 Off (Normally Open) or 1 On (Normally Closed) | 3 | SPDT | 10 A @ 600 V AC, 10 A @ 250 V DC | 250V DC/600V AC | 25 | 1/2 | No | 1/4" (2) | 5/16"-18 (2) | Tension Indicator | 0000000 | 000000000 |
200 | 2 | 2 On (Normally Closed) | 4 | DPST-NC | 10 A @ 600 V AC, 10 A @ 250 V DC | 250V DC/600V AC | 25 | 1/2 | No | 1/4" (2) | 5/16"-18 (2) | Tension Indicator | 0000000 | 00000000 |
Hazardous Location Enclosed Motor Switches

Safely turn motors on and off near ignitable gases and dust—the housing on these switches seals in anything that could ignite flammable material. Made from aluminum, the housing is lightweight and durable. It guards against water, oil, and other materials that could cause damage. Even in harsh conditions, there’s no need to mount these switches inside an electrical panel.
You need to grip and twist the lever to actuate these switches, so they won’t accidentally turn on or off if something bumps into them. In addition to starting and stopping motors, they work with other circuits, such as lighting and electric heat circuits. They don’t provide overload protection.
For technical drawings and 3-D models, click on a part number.
Switching | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Circuits Controlled | Electrical Phase (hp) | Switch Starting Position | Industry Designation | Current, A | Voltage | Ht. | Wd. | Wire Connection Type | Environmental Rating | Specifications Met | Each | |
Stays Switched (Maintained) | ||||||||||||
2 | Single (3 hp @ 240 V AC) | 2 Off (Normally Open) | DPST-NO | 30 | 600V AC | 6.5" | 3" | Screw Terminals | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 NEMA 9 | UL Listed, C-UL Listed, CSA Certified | 0000000 | 0000000 |
3 | Three (7 1/2 hp @ 240 V AC) | 3 Off (Normally Open) | 3PST-NO | 30 | 600V AC | 6.5" | 3" | Screw Terminals | NEC Class I Divisions 1, 2 Groups C, D NEC Class II Divisions 1, 2 Groups E, F, G NEMA 7 NEMA 9 | UL Listed, C-UL Listed, CSA Certified | 0000000 | 000000 |