McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    114 Products
    About Electrical Switches
    industrial info icon

    Choose a switch with the right trigger type, number of inputs, and control functions to power your equipment.

    Rocker Switches

    Image of Product. Style B. Front orientation. Style B. Rocker Switches.
    Image of Product. Style C. Front orientation. Style C. Rocker Switches.

    Style B

    Style C

    The wide surface of these switches makes them easy to press on and off, even if your hands are full and you need to use an elbow. They’re often used as power switches on electronic devices and control panels.
    Note: Illuminated switches include a bulb. If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed the bulb voltage.
    For 13/16" Diameter Panel Cutouts—Switches for a 13/16” dia. panel cutout are round, so you can use a drill bit or knockout to install them instead of cutting a rectangular hole.
    On-On—Switches with an on-on position designation alternate power between sets of terminals.
    Style
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Position
    Designation
    Switching Current @ Voltage
    Max. Voltage,
    V AC
    Quick-Disconnect
    Tab Wd.
    Color
    Each
    2 Positions with Quick-Disconnect Terminals
     
    For 13/16" Diameter Panel Cutouts
    B22 Off or 2 On
    Maintained
    2DPDT
    On-On
    16 amp @ 125V AC, 10 amp @ 250V AC2500.189"Black7395K13400000
     
    For 1 3/16" High × 7/8" Wide Panel Cutouts
    C22 Off or 2 On
    Maintained
    6DPDT
    On-On
    16 amp @ 125V AC2500.25"Black7395K140000
    C22 Off or 2 On
    Maintained
    6DPDT
    On-On
    20 amp @ 125V AC, 16 amp @ 250V AC2500.25"Black7395K1150000
     
    3 Positions with Quick-Disconnect Terminals
     
    For 13/16" Diameter Panel Cutouts
    B22 Off or 2 On
    Maintained
    2DPDT
    On-Off-On
    16 amp @ 125V AC, 10 amp @ 250V AC2500.189"Black7395K1210000
     
    For 0.83" High × 1.45" Wide Panel Cutouts
    C22 Off
    Momentary
    6DPDT
    (On)-Off-(On)
    15 amp @ 125V AC, 10 amp @ 250V AC2500.25"Black7395K62200000
    C22 Off or 2 On
    Maintained
    6DPDT
    On-Off-On
    15 amp @ 125V AC, 10 amp @ 250V AC2500.25"Black7395K61100000
     
    For 1 3/16" High × 7/8" Wide Panel Cutouts
    C22 Off or 2 On
    Maintained
    6DPDT
    On-Off-On
    15 amp @ 125V AC, 10 amp @ 250V AC2500.25"Black7395K1160000
     

    Toggle Switches

    Image of Product. Front orientation. Toggle Switches. Toggle Switches , Rounded Toggle.
    Image of Specification. Back orientation. Contains Border. Quick-Disconnect-Terminal Wire Connection. Toggle Switches .
    Image of Specification. Back orientation. Contains Border. Screw-Terminal Wire Connection. Toggle Switches .
    Image of Specification. Back orientation. Contains Border. Tab Wire Connection. Toggle Switches .

    Rounded Toggle

    Quick-Disconnect-Terminal

    Wire Connection

    Screw-Terminal

    Wire Connection

    Tab Wire

    Connection

    Simple and reliable, these switches are used on all things electric. Not sure if that switch will work for you? Click the "i" symbols in the table to learn more about switch specifications.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch Action
    No. of
    Terminals
    Switch
    Designation
    Position
    Designation
    Switching Current
    @ Voltage
    Max. Voltage
    For Max.
    Panel Thk.
    Mounting Hardware
    Included
    Mounting Thread
    Size
    Choose a Wire Connection
    Each
    2 Position with Rounded Toggle
     
    For 1/2" Diameter Panel Cutouts
    22 Off or 2 On
    Maintained, Momentary
    6DPDT
    On-(On)
    15 amp @ 125V AC/28V DC28V DC
    250V AC
    0.13"Yes15/32"-32
    Quick-Disconnect Terminal, Screw Terminal7343K58000000
    22 Off or 2 On
    Maintained
    6DPDT
    On-On
    6 amp @ 125V AC/28V DC28V DC
    250V AC
    0.13"Yes15/32"-32
    Quick-Disconnect Terminal, Screw Terminal7343K27300000
    22 Off or 2 On
    Maintained
    6DPDT
    On-On
    15 amp @ 125V AC/28V DC28V DC
    250V AC
    0.13"Yes15/32"-32
    Quick-Disconnect Terminal, Screw Terminal, Tab7343K82100000
     
    3 Position with Rounded Toggle
     
    For 1/2" Diameter Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-Off-On
    6 amp @ 125V AC/28V DC28V DC
    250V AC
    0.13"Yes15/32"-32
    Quick-Disconnect Terminal, Screw Terminal7343K26300000
    22 Off or 2 On
    Maintained
    6DPDT
    On-Off-On
    15 amp @ 125V AC/28V DC28V DC
    250V AC
    0.13"Yes15/32"-32
    Quick-Disconnect Terminal, Screw Terminal, Tab7343K79100000
    22 Off or 2 On
    Momentary
    6DPDT
    (On)-Off-(On)
    15 amp @ 125V AC/28V DC28V DC
    250V AC
    0.13"Yes15/32"-32
    Quick-Disconnect Terminal, Screw Terminal7343K92300000
     

    Mil. Spec. Washdown Toggle Switches

    Image of Product. Front orientation. Toggle Switches. Mil. Spec. Washdown Toggle Switches .
    These switches meet MIL-S-3950. A rubber seal protects them from washdowns.
    On-On, On-on-On, and (On)-on-On—Switches with an on-on, on-on-on, or (on)-on-on position designation alternate power between sets of terminals.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Position
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Dp. Behind
    Panel
    Mounting Hardware
    Included
    Wire
    Connection
    Each
    2 Positions
     
    For 1/2" Diameter Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-On
    15 amp @ 125V AC/28V DC28V DC
    125V AC
    1.35"YesScrew Terminal8002K126000000
    22 Off or 2 On
    Momentary
    6DPDT
    On-(On)
    8 amp @ 125V AC, 10 amp @ 28V DC28V DC
    125V AC
    1.35"YesScrew Terminal8002K13200000
     
    3 Positions
     
    For 1/2" Diameter Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-Off-On
    15 amp @ 125V AC/28V DC28V DC
    125V AC
    1.35"YesScrew Terminal8002K11700000
    22 Off or 2 On
    Maintained
    6DPDT
    On-on-On
    15 amp @ 125V AC/28V DC28V DC
    125V AC
    1.35"YesScrew Terminal8002K12500000
    22 Off or 2 On
    Momentary
    6DPDT
    (On)-Off-On
    8 amp @ 125V AC, 10 amp @ 28V DC28V DC
    125V AC
    1.35"YesScrew Terminal8002K12700000
    22 Off or 2 On
    Momentary
    6DPDT
    (On)-Off-(On)
    8 amp @ 125V AC, 10 amp @ 28V DC28V DC
    125V AC
    1.35"YesScrew Terminal8002K11900000
    22 Off or 2 On
    Momentary
    6DPDT
    (On)-on-On
    8 amp @ 125V AC, 10 amp @ 28V DC28V DC
    125V AC
    1.35"YesScrew Terminal8002K12800000
    22 Off or 2 On
    Momentary
    6DPDT
    (On)-on-(On)
    8 amp @ 125V AC, 10 amp @ 28V DC28V DC
    125V AC
    1.35"YesScrew Terminal8002K13100000
     

    Wet-Environment Toggle Switches

    Image of Product. Front orientation. Toggle Switches. Wet-Environment Toggle Switches, Rounded Toggle.
    Image of Product. Front orientation. Toggle Switches. Wet-Environment Toggle Switches, Rounded Toggle, Wire Lead Connection.

    Rounded Toggle

    Rounded Toggle,

    Wire Lead

    Connection

    A rubber seal protects these switches from splashing water.
    Switches with maintained/momentary switch action stay switched from one side and spring back from the other side.
    IP67 Enclosure Rating—IP67 rated switches are protected against temporary submersion.
    IP68 Enclosure Rating, NEMA 4 Enclosure Rating, and NEMA 13 Enclosure Rating—NEMA 4, 13, and IP68 rated switches are protected against oil/coolant spraying, washdowns, and temporary submersion.
    On-(On) and On-On—Switches with an on-on or on-(on) position designation alternate power between sets of terminals.
    Wire
    Leads
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch Action
    No. of
    Terminals
    Switch
    Designation
    Position
    Designation
    Switching Current @ Voltage
    Max. Voltage
    For Max.
    Panel Thk.
    No.
    of
    Lg.
    Mounting Hardware
    Included
    Mounting Thread
    Size
    Choose a Wire Connection
    Each
    2 Position with Rounded Toggle—NEMA 4, NEMA 13, IP68
     
    For 1/2" Diameter Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-On
    15 amp @ 125V AC/28V DC28V DC
    277V AC
    0.13"Yes15/32"-32
    Quick-Disconnect Terminal, Screw Terminal8002K82000000
     
    2 Position with Rounded Toggle—IP67
     
    For 1/2" Diameter Panel Cutouts
    22 Off or 2 On
    Maintained, Momentary
    6DPDT
    On-(On)
    15 amp @ 125V AC, 20 amp @ 28V DC30V DC
    250V AC
    0.16"YesM12 × 1 mmQuick-Disconnect Terminal, Tab7172K3100000
    22 Off or 2 On
    Maintained
    6DPDT
    On-On
    20 amp @ 125V AC, 20 amp @ 28V DC30V DC
    250V AC
    0.16"612"YesM12 × 1 mmWire Leads7172K28200000
    22 Off or 2 On
    Maintained
    6DPDT
    On-On
    20 amp @ 125V AC/28V DC30V DC
    250V AC
    0.16"YesM12 × 1 mmQuick-Disconnect Terminal, Tab7172K2800000
     
    3 Position with Rounded Toggle— NEMA 4, NEMA 13, IP68
     
    For 1/2" Diameter Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-Off-On
    15 amp @ 125V AC/28V DC28V DC
    277V AC
    0.13"Yes15/32"-32
    Quick-Disconnect Terminal, Screw Terminal8002K7900000
    22 Off or 2 On
    Momentary
    6DPDT
    (On)-Off-(On)
    10 amp @ 125V AC/28V DC28V DC
    277V AC
    0.13"Yes15/32"-32
    Quick-Disconnect Terminal, Screw Terminal8002K9800000
     
    3 Position with Rounded Toggle—IP67
     
    For 1/2" Diameter Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-Off-On
    20 amp @ 125V AC, 20 amp @ 28V DC30V DC
    250V AC
    0.16"612"YesM12 × 1 mmWire Leads7172K29200000
    22 Off or 2 On
    Maintained
    6DPDT
    On-Off-On
    20 amp @ 125V AC/28V DC30V DC
    250V AC
    0.16"YesM12 × 1 mmQuick-Disconnect Terminal, Tab7172K2900000
    22 Off or 2 On
    Momentary
    6DPDT
    (On)-Off-On
    15 amp @ 125V AC, 20 amp @ 28V DC30V DC
    250V AC
    0.16"YesM12 × 1 mmQuick-Disconnect Terminal, Tab7172K3300000
    22 Off or 2 On
    Momentary
    6DPDT
    (On)-Off-On
    15 amp @ 125V AC, 20 amp @ 28V DC30V DC
    250V AC
    0.16"612"YesM12 × 1 mmWire Leads7172K33200000
    22 Off or 2 On
    Momentary
    6DPDT
    (On)-Off-(On)
    15 amp @ 125V AC, 20 amp @ 28V DC30V DC
    250V AC
    0.16"YesM12 × 1 mmQuick-Disconnect Terminal, Tab7172K3200000
    22 Off or 2 On
    Momentary
    6DPDT
    (On)-Off-(On)
    15 amp @ 125V AC, 20 amp @ 28V DC30V DC
    250V AC
    0.16"612"YesM12 × 1 mmWire Leads7172K32200000
     

    Slide Switches

    Image of Product. Front orientation. Slide Switches.
    Like turning on a flashlight, slide these switches from one side to the other.
    Mounting
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current @ Voltage
    Max. Voltage
    Dp. Behind
    Panel
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Each
    2 Positions with Tab Wire Connection
     
    For 7/8" Ht. × 1/2" Wd. Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    6 amp @ 125V AC, @ 1 amp @ 125V DC125V DC
    250V AC
    9/16"No25/32"66065K2300000
     

    Miniature Toggle Switches

    Image of Product. Front orientation. Toggle Switches. Miniature Toggle Switches .
    Maximize the space in a panel—these switches are half the size of most toggle switches.
    On-(On) and On-On—Switches with an on-on or on-(on) position designation alternate power between sets of terminals.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Position
    Designation
    Switching Current @ Voltage
    Max. Voltage
    For Max.
    Panel Thk.
    Mounting Hardware
    Included
    Mounting
    Thread Size
    Choose a Wire Connection
    Each
    2 Position with Rounded Toggle
     
    For 1/4" Diameter Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-On
    6 amp @ 125V AC, 4 amp @ 30V DC30V DC
    250V AC
    0.16"Yes1/4"-40
    Quick-Disconnect Terminal, Tab7347K82000000
    22 Off or 2 On
    Momentary
    6DPDT
    On-(On)
    6 amp @ 125V AC, 4 amp @ 30V DC30V DC
    250V AC
    0.16"Yes1/4"-40
    Tab7347K2400000
     
    3 Position with Rounded Toggle
     
    For 1/4" Diameter Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-Off-On
    6 amp @ 125V AC, 4 amp @ 30V DC30V DC
    250V AC
    0.16"Yes1/4"-40
    Quick-Disconnect Terminal, Tab7347K7900000
    22 Off or 2 On
    Momentary
    6DPDT
    (On)-Off-(On)
    6 amp @ 125V AC, 4 amp @ 30V DC30V DC
    250V AC
    0.16"Yes1/4"-40
    Quick-Disconnect Terminal, Tab7347K8100000
     

    DIN-Rail Mount Miniature Toggle Switches

    Image of ProductInUse. Switch Shown Mounted. Front orientation. Toggle Switches. DIN-Rail Mount Miniature Toggle Switches .
    Image of Product. Front orientation. Toggle Switches. DIN-Rail Mount Miniature Toggle Switches .

    Switch Shown

    Mounted

    Built into a terminal block, these switches mount to DIN rail. They can be mounted side-by side.
    On-On—Switches with an on-on or on-(on) position designation alternate power between sets of terminals.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Position
    Designation
    Switching Current
    @ Voltage
    Max. Voltage
    For DIN
    Rail Ht., mm
    Wire
    Connection
    Each
    2 Position with Rounded Toggle
    22 Off or 2 On
    Maintained
    6DPDT
    On-On
    5 amp @ 120V AC/28V DC28V DC
    250V AC
    35Screw Terminal7218K6110000000
     

    Foot Switches

    Image of Product. Front orientation. Foot Switches. Foot Switches, Back Pivot with 1 Pedal.
    Image of Product. Front orientation. Foot Switches. Foot Switches, Back Pivot with 3 Pedals.

    Back Pivot with 1 Pedal

    Back Pivot with 3 Pedals

    Keep your hands free for other tasks by triggering switches with your foot.
    Back—Back-pivot switches actuate with a tap of the toe.
    Switch Guards—Guards (sold separately) prevent accidental switch actuation.
    Foot Switches
    Switch Guards
    Mounting
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Switch
    Designation
    Switching Current @ Voltage
    Housing
    Material
    Wire Connection
    No. of
    Terminals
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Each
    Each
    1 Speed
     
    Back Pivot with 1 Pedal
    22 Off or 2 On
    Momentary
    DPDT
    15 amp @ 125V AC, 10 amp @ 250V AC, 3 amp @ 3V DCIronQuick-Disconnect Terminal6No20.22"7024K30000007024K5000000
    22 Off or 2 On
    Maintained
    DPDT
    10 amp @ 125V AC, 250V AC, 3 amp @ 28V DCIronTab6No20.22"7024K40000007024K500000
     
    Back Pivot with 3 Pedals
    62 Off or 2 On
    Momentary
    DPDT
    3 amp @ 240V ACAluminumScrew Terminal187829N1300000000———0
     

    High-Current Toggle Switches

    Image of Product. Front orientation. Toggle Switches. High-Current Toggle Switches .
    Able to withstand high currents, these switches are often used with motors and pumps.
    On-On—Switches with an on-on position designation alternate power between sets of terminals.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Position
    Designation
    Switching Current
    @ Voltage
    Max. Voltage
    Dp. Behind
    Panel
    Mounting Hardware
    Included
    Each
    2 Position with Screw Terminals
     
    For 1/2" Diameter Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-On
    30 amp @ 125V AC/30V DC30V DC
    250V AC
    1.34"Yes8001K12000000
     
    3 Position with Screw Terminals
     
    For 1/2" Diameter Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-Off-On
    30 amp @ 125V AC/30V DC30V DC
    250V AC
    1.34"Yes8001K1300000
     

    Hazardous Location Foot Switches

    Image of Product. With One Pedal. Front orientation. Foot Switches. Hazardous Location Foot Switches, 1 Pedal, Oversized Guard, Back.

    With One Pedal

    These switches are rated for environments where hazardous material is present. Press the pedal with your foot for hands-free operation. They have an oversized guard that accommodates bulky footwear.
    Hazardous Location Rating—Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
    Mounting
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Switch
    Designation
    Switching Current
    @ Voltage
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Hazardous Location Rating
    Enclosure Rating
    Each
    1 Speed with Screw Terminal
     
    Aluminum Housing with 1 Pedal, Oversized Guard, and Back Pivot
    22 Off or 2 On
    Momentary
    DPDT
    20 amp @ 125V AC, 250V ACNo60.28"NEC Class I Divisions 1, 2 Group D
    NEC Class II Divisions 1, 2 Groups F, G
    NEC Zone 1 Group IIA
    IP41, NEMA 2, NEMA 7, NEMA 97480K240000000
     

    Pull-to-Unlock Toggle Switches

    Image of Product. Front orientation. Toggle Switches. Pull-to-Unlock Toggle Switches , Ball-End Toggle.

    Ball-End Toggle

    Prevent accidental actuation—these toggle switches must be pulled out before they can switch a circuit.
    Ball-End Toggle—Ball end toggle switches are rated NEMA 4, 13, and IP68 for protection against washdowns, oil/coolant spraying, and temporary submersion.
    On-On—Switches with an on-on position designation alternate power between sets of terminals.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Position
    Designation
    Switching Current
    @ Voltage
    Max. Voltage
    For Max.
    Panel Thk.
    Mounting Hardware
    Included
    Mounting Thread
    Size
    Wire
    Connection
    Each
    2 Position with Ball-End Toggle—NEMA 4, NEMA 13, IP68
     
    For 1/2" Diameter Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-On
    15 amp @ 125V AC/28V DC28V DC
    277V AC
    0.13"Yes15/32"-32
    Screw Terminal7337K98000000
     

    Submersible High-Starting-Current Rocker Switches

    Image of Product. Blank. Front orientation. Rocker Switches. Submersible High-Starting-Current Rocker Switches, Without Guard, Quick-Disconnect-Terminal Wire Connection, Not Illuminated, Blank.

    Blank

    Rated IP67 for protection from dust and temporary submersion. Also known as high-inrush current switches, these switches can handle starting currents up to 10 times greater than their current rating, such as when a motor starts. They're often used with amplifiers, power supplies, and other high-starting-current devices. Easy to press, these switches have a wide, flat actuation area. Color-code your switches so that operators can identify their function at a glance.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Position
    Designation
    Message (Location)
    Switching Current @ Voltage
    Max. Voltage
    Quick-Disconnect
    Tab Wd.
    Choose a
    Color
    Each
    2 Positions with Quick-Disconnect Terminals
     
    For 1" High × 19/32" Wide Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-On
    Blank (Top), Blank (Bottom)10 amp @ 125V AC, 10 amp @ 30V DC250V AC, 30V DC0.11"Black, Red7194K127000000
     
    For 1 7/32" High × 13/16" Wide Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-On
    Blank (Top), Blank (Bottom)16 amp @ 125V AC250V AC0.187"Black, Red7194K12200000
     

    Wet-Location Foot Switches

    Image of Product. Switch. Front orientation. Foot Switches. Wet-Location Foot Switches, Without Guard.
    Image of Product. Switch with Guard. Front orientation. Foot Switches. Wet-Location Foot Switches, Aluminum Guard, With Guard.

    Switch

    Switch with Guard

    Image of Product. Switch with Oversized Guard. Front orientation. Foot Switches. Wet-Location Foot Switches, With Guard, Oversized Guard, Aluminum Guard.
    Image of Product. Switch with Safety Lever and Oversized Guard. Front orientation. Contains Inset, Border. Foot Switches. Wet-Location Foot Switches, Oversized Guard, Safety Lever, Aluminum Guard, With Guard.

    Switch with Oversized Guard

    Switch with Safety Lever and Oversized

    Guard

    Operate these switches hands-free when working in wet or humid environments. They’re IP and NEMA rated, so they won’t corrode when exposed to water, oil, or coolant spray.
    Oversized Guard—Switches with an oversized guard fit bulky shoes and toe guards.
    Safety Lever—Switches with a safety lever lock the pedal in place to prevent accidental activation. Fully insert your foot to release the safety lever. If the lever isn't released, the pedal won't depress.
    With Guard—Switches with a guard shield the pedal so you don't accidentally step on it and activate the switch.
    Without Guard—Switches without a guard are unobstructed and let you press them from multiple angles.
    Number of
    Mounting
    Speeds
    Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Switch
    Designation
    Switching Current @ Voltage
    Wire
    Connection
    No. of
    Terminals
    Conduit
    Trade Size
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Each
    Iron Housing
     
    IP56, NEMA 4, NEMA 13
    122 Off or 2 On
    Momentary
    DPDT
    20 amp @ 125V AC, 250V AC, 0.5 amp @ 125V DC, 0.25 amp @ 250V DCScrew Terminal63/4
    No30.31"7372K1030000000
     
    Iron Housing with Aluminum Guard
     
    IP56, NEMA 4, NEMA 13
    122 Off or 2 On
    Momentary
    DPDT
    20 amp @ 125V AC, 250V AC, 0.5 amp @ 125V DC, 0.25 amp @ 250V DCScrew Terminal63/4
    No30.31"7372K12000000
     
    Iron Housing with Oversized Aluminum Guard
     
    IP56, NEMA 4, NEMA 13
    122 Off or 2 On
    Momentary
    DPDT
    20 amp @ 125V AC, 250V AC, 0.5 amp @ 125V DC, 0.25 amp @ 250V DCScrew Terminal63/4
    No30.31"7372K34000000
     
    Iron Housing with Safety Lever and Oversized Aluminum Guard
     
    IP56, NEMA 4, NEMA 13
    122 Off or 2 On
    Momentary
    DPDT
    20 amp @ 125V AC, 250V AC, 0.5 amp @ 125V DC, 0.25 amp @ 250V DCScrew Terminal63/4
    No30.31"7344K32000000
     
    Switch Guards

    Design-Your-Own Rocker Switches

    Choose from a variety of messages and colored lenses to combine a rocker with a base for a complete switch.
    Note: Illuminated switches include a bulb. If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed the bulb voltage.
    Bases with Quick-Disconnect Terminals for 1 3/4" High × 7/8" Wide Panel Cutouts
    Image of Product. Front orientation. Rocker Switches. Design-Your-Own Rocker Switches, Not Illuminated, Bases, Quick-Disconnect-Terminal Wire Connection.
    On-On—Bases with an on-on position designation alternate power between sets of terminals.
    No. of
    Positions
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Position
    Designation
    Color
    Switching Current @ Voltage
    Max. Voltage
    Quick-Disconnect
    Tab Wd.
    Each
    222 Off or 2 On
    Maintained
    6DPDT
    On-On
    Black15 amp @ 125V AC, 15 amp @ 28V DC250V AC, 30V DC0.25"1789N16000000
    322 Off or 2 On
    Momentary
    6DPDT
    (On)-Off-(On)
    Black15 amp @ 125V AC, 15 amp @ 28V DC250V AC, 30V DC0.25"1789N1500000
    Illuminated Bases with Quick-Disconnect Terminals for 1 3/4" High × 7/8" Wide Panel Cutouts
    Image of Product. Front orientation. Rocker Switches. Design-Your-Own Rocker Switches, Quick-Disconnect-Terminal Wire Connection, Bases, Illuminated.
    On-On—Bases with an on-on position designation alternate power between sets of terminals.
    No. of
    Positions
    Position
    Illuminated
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Position
    Designation
    Color
    Switching Current @ Voltage
    Max. Voltage
    Bulb Voltage,
    V DC
    Quick-Disconnect
    Tab Wd.
    Each
    2Top/Bottom22 Off or 2 On
    Maintained
    10DPDT
    On-On
    Black15 amp @ 125V AC, 15 amp @ 28V DC250V AC, 30V DC140.25"1789N58000000
    3Top/Bottom22 Off or 2 On
    Maintained
    10DPDT
    On-Off-On
    Black15 amp @ 125V AC, 15 amp @ 28V DC250V AC, 30V DC140.25"1789N5900000
    3Top/Bottom22 Off or 2 On
    Momentary
    10DPDT
    (On)-Off-(On)
    Black15 amp @ 125V AC, 15 amp @ 28V DC250V AC, 30V DC140.25"1789N6100000

    Recessed Push-Button Switches

    Image of Product. Front orientation. Push-Button Switches. Recessed Push-Button Switches.
    Often used to trigger alarms, these switches have a recessed button to prevent accidental activation. Mount under desks or in other discreet locations to avoid drawing attention.
    Housing
    Actuator
    Color
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Ht
    Wd.
    Dp.
    Material
    Color
    Mounting Fasteners
    Included
    Each
    Plastic Actuator with Screw-Terminal Wire Connection
     
    Round Push Button
    Ivory21 Off and 1 On
    Momentary
    6DPDT
    2 5/16"2"1"PlasticIvoryYes1735N101000000
     

    Cable-Pull-Actuator Emergency Stop Switches with Restart Switch

    Tug the cable to stop your line, then follow it back to the restart switch. Typically separate devices, the stop and reset controls are in one compact unit. As a secondary shutdown option, a push-button stop switch is also built in. A secondary push-button stop switch ensures you can halt equipment immediately, even when the cable is out of reach. Because they let you control circuits from a distance with a quick tug, these cable-pull stop switches are often used to turn off production lines and material handling systems. To notify your team on the floor that you’ve stopped equipment, a power indicator lights up when you pull the cable.
    Use the tension indicator to confirm that cable is set up correctly. Circuits remain open until you tension the cable and hit the restart button. Cable is not included.
    1 Direction
    Image of Product. Left Side Cable Location. Front orientation. Emergency Stop Switches. Cable-Pull-Actuator Emergency Stop Switches with Restart Switch, 1 Direction, Tension Indicator, Power Indicator, Restart Button, Emergency Stop Button, Left-Side Cable.
    Image of Product. Right Side Cable Location. Front orientation. Emergency Stop Switches. Cable-Pull-Actuator Emergency Stop Switches with Restart Switch, 1 Direction, Tension Indicator, Power Indicator, Restart Button, Emergency Stop Button, Right-Side-Cable.

    Left Side Cable

    Location

    Right Side Cable

    Location

    Mounting
    Cable
    Location
    For Max.
    Cable Lg., ft.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    No. of
    Terminals
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage
    Actuation
    Force, lbf
    Conduit
    Trade Size
    Bulb
    Voltage
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Each
    Screw-Terminal Wire Connection
     
    With Emergency Stop Button, Power Indicator, Restart Button, Tension Indicator (IP54, NEMA 1)
    Left Side32522 Off or 2 On
    6DPDT
    6 amp @ 120V AC
    2.8 amp @ 24V DC
    240V AC
    24V DC
    111/2
    24V DCNo41/4"5746N301000000000
    Left Side32522 Off or 2 On
    6DPDT
    6 amp @ 120V AC
    2.8 amp @ 24V DC
    240V AC
    24V DC
    111/2
    120V ACNo41/4"5746N20100000000
    Right Side32522 Off or 2 On
    6DPDT
    6 amp @ 120V AC
    2.8 amp @ 24V DC
    240V AC
    24V DC
    111/2
    24V DCNo41/4"5746N1100000000
    Right Side32522 Off or 2 On
    6DPDT
    6 amp @ 120V AC
    2.8 amp @ 24V DC
    240V AC
    24V DC
    111/2
    120V ACNo41/4"5746N20200000000
     
    2 Directions
    Image of Product. Front orientation. Emergency Stop Switches. Cable-Pull-Actuator Emergency Stop Switches with Restart Switch, 2 Directions.
    Two-direction switches support twice the total cable distance of one-direction switches. With pulls on each side, you can route cable in two opposite directions. These switches are often placed at the midpoint of conveyors and other long runs of equipment.
    Mounting
    Cable Location
    For Max.
    Cable Lg., ft.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    No. of
    Terminals
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage
    Actuation
    Force, lbf
    Conduit
    Trade Size
    Bulb
    Voltage
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Each
    Screw-Terminal Wire Connection
     
    With Emergency Stop Button, Power Indicator, Restart Button, Tension Indicator (IP54, NEMA 1)
    Left Side, Right Side32522 Off or 2 On
    6DPDT
    6 amp @ 120V AC
    2.8 amp @ 24V DC
    240V AC
    24V DC
    111/2
    24V DCNo41/4"5746N12000000000
    Left Side, Right Side32522 Off or 2 On
    6DPDT
    6 amp @ 120V AC
    2.8 amp @ 24V DC
    240V AC
    24V DC
    111/2
    120V ACNo41/4"5746N20400000000
     

    Corrosion-Resistant Washdown Foot Switches

    Image of Product. Style C. Front orientation. Foot Switches. Corrosion-Resistant Washdown Foot Switches, Quick-Disconnect-Terminal Wire Connection, Without Guard, Style C.
    Image of Product. Style D. Front orientation. Foot Switches. Corrosion-Resistant Washdown Foot Switches, Quick-Disconnect-Terminal Wire Connection, Without Guard, Style D.

    Style C

    Style D

    Image of Product. Style E. Front orientation. Foot Switches. Corrosion-Resistant Washdown Foot Switches, Quick-Disconnect-Terminal Wire Connection, With Guard, Style E.
    Image of Product. Style F. Front orientation. Foot Switches. Corrosion-Resistant Washdown Foot Switches, Quick-Disconnect-Terminal Wire Connection, With Guard, Style F.

    Style E

    Style F

    Step on these switches to actuate a process hands-free in an area with frequent washdowns. Rated NEMA 6P, 13, and IP68, they protect against corrosion, washdowns, temporary submersion, and oil/coolant spraying. Made of aluminum, they resist corrosion better than iron and steel switches.
    1 Speed with Quick-Disconnect Terminals
    Image of Product. Style C. Front orientation. Foot Switches. Corrosion-Resistant Washdown Foot Switches, Quick-Disconnect-Terminal Wire Connection, Without Guard, Style C.
    Image of Product. Style D. Front orientation. Foot Switches. Corrosion-Resistant Washdown Foot Switches, Quick-Disconnect-Terminal Wire Connection, Without Guard, Style D.

    Style C

    Style D

    Image of Product. Style E. Front orientation. Foot Switches. Corrosion-Resistant Washdown Foot Switches, Quick-Disconnect-Terminal Wire Connection, With Guard, Style E.
    Image of Product. Style F. Front orientation. Foot Switches. Corrosion-Resistant Washdown Foot Switches, Quick-Disconnect-Terminal Wire Connection, With Guard, Style F.

    Style E

    Style F

    With Guard—Switches with a guard shield the pedal so you don't accidentally step on it and activate the switch.
    Without Guard—Switches without a guard let you easily see the pedal and step on it from many angles.
    Foot Switches
    Foot
    Switch Pedals
    Mounting
    Style
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Switch
    Designation
    Switching Current
    @ Voltage
    No. of
    Terminals
    Quick-Disconnect
    Tab Wd.
    Conduit
    Trade Size
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Each
    Each
    Aluminum Housing
    C22 Off or 2 On
    Momentary
    DPDT
    16 amp @ 125V AC, 250V AC60.187"1/2
    No40.28"7670K8200000007670K1300000
    D42 Off or 2 On
    Momentary
    DPDT
    16 amp @ 125V AC, 250V AC120.187"3/4
    No40.28"7670K860000007670K130000
     
    Aluminum Housing with Steel Guard
    E22 Off or 2 On
    Momentary
    DPDT
    16 amp @ 125V AC, 250V AC60.187"1/2
    No40.28"7670K840000007670K130000
    F42 Off or 2 On
    Momentary
    DPDT
    16 amp @ 125V AC, 250V AC120.187"3/4
    No40.28"7670K880000007670K130000
     

    Light Duty Foot Switches

    Use these switches for intermittent, light duty applications.
    1 Speed with Wire Leads
    Image of Product. Front orientation. Foot Switches. Light Duty Foot Switches, Wire Lead Connection, 1 Pedal.
    Image of Product. Front orientation. Foot Switches. Light Duty Foot Switches, Wire Lead Connection, 2 Pedals.
    Image of Product. Front orientation. Foot Switches. Light Duty Foot Switches, Wire Lead Connection, 3 Pedals.

    1 Pedal

    2 Pedals

    3 Pedals

    IP43—IP43 rated switches can be used in industrial kitchen settings or around machinery where light water spray might occur.
    Foot Switches
    Foot
    Switch Pedals
    Number of
    Wire
    Leads
    Pedals
    Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    Switch
    Designation
    Switching Current
    @ Voltage
    No.
    of
    Lg.,
    ft.
    Color
    Each
    Each
    Plastic Housing
     
    IP43
    122 Off or 2 On
    Momentary
    DPDT
    5 amp @ 125V AC, 250V AC66Black7516K30200000007516K319000000
    122 Off or 2 On
    Maintained
    DPDT
    5 amp @ 125V AC, 250V AC66Black7516K3040000007516K31900000
    242 Off or 2 On
    Momentary
    DPDT
    5 amp @ 125V AC, 250V AC126Black7516K3050000007516K31900000
    242 Off or 2 On
    Maintained
    DPDT
    5 amp @ 125V AC, 250V AC126Black7516K3070000007516K31900000
    362 Off or 2 On
    Momentary
    DPDT
    5 amp @ 125V AC, 250V AC186Black7516K3110000007516K31900000
    362 Off or 2 On
    Maintained
    DPDT
    5 amp @ 125V AC, 250V AC186Black7516K3130000007516K31900000
     

    30 mm Multifunction Panel-Mount Push-Button Switches

    Image of Product. Front orientation. Not Illuminated. 30 mm Multifunction Panel-Mount Push-Button Switches.
    Save space on a panel by using one switch to perform multiple functions. These switches are rated NEMA 4, 4X, and 13 for protection from corrosion, washdowns, and oil/coolant spraying. They include enough contact blocks to control the number of circuits listed.
    Note: If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    No. of
    Buttons
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Message (Actuator Color)
    Switching Current @ Voltage
    For Max.
    Panel Thk.
    Dp. Behind
    Panel
    For Max. No. of
    Contact Blocks
    Enclosure Rating
    Each
    Metal Actuator Base with Screw-Terminal Wire Connection—Not Illuminated (600V AC/600V DC Maximum Voltage)
     
    Projecting
    21 Off and 1 On
    2Momentary
    4DPDT
    Start (Green), Stop (Red)6 amp @ 120V AC, 0.55 amp @ 125V DC1/4"1 7/8"6NEMA 4, NEMA 4X, NEMA 13
    8230K270000000
     
    Blocks

    Cable-Pull-Actuator Emergency Stop Switches

    Image of Product. Front orientation. Emergency Stop Switches. Cable-Pull-Actuator Emergency Stop Switches, 1 Direction (IP65, NEMA 4).

    1 Direction (IP65,

    NEMA 4)

    Immediately cut power by pulling a cable. These switches are often used to turn off production lines and material handling systems in an emergency. All have positive-force, snap-open contacts that open a circuit when actuated, even if a spring fails or the contacts stick. The contacts will remain open until you tension the cable and reset the switch.
    Switch Installation Kits—Accessory kits (sold separately) simplify the installation of a new switch.
    Emergency Stop Switches
    Switch Installation Kits
    Mounting
    For Max.
    Cable Lg., ft.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    No. of
    Terminals
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage,
    V AC
    Actuation
    Force, lbf
    Conduit
    Trade Size
    Fasteners
    Included
    Hole
    Dia.
    No. of
    Holes
    Each
    Includes
    Each
    Screw-Terminal Wire Connection
     
    1 Direction (IP65, NEMA 4)
    7522 Off or 2 On
    6DPDT
    10 amp @ 120V AC380451/2
    No1/4"465975K630000000Cable, Clamps, Tension Screws, Thimbles65975K830000000
     

    High-Starting-Current Rocker Switches

    Image of Product. Blank. Front orientation. Rocker Switches. High-Starting-Current Rocker Switches, Tab Wire Connection, Without Guard, Not Illuminated, Blank.
    Image of Product. Blank with Wire Leads. Front orientation. Rocker Switches. High-Starting-Current Rocker Switches, Wire Lead Connection, Not Illuminated, Without Guard, Blank.

    Blank

    Blank with

    Wire Leads

    Also known as high-inrush current switches, these switches can handle starting currents up to 10 times greater than their current rating, such as when a motor starts. They're often used with amplifiers, power supplies, and other high-starting-current devices.
    On-On—Switches with an on-on position designation alternate power between sets of terminals.
    Wire
    Leads
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Position
    Designation
    Message (Location)
    Switching Current @ Voltage
    Max. Voltage
    No.
    of
    Lg.
    Choose a
    Color
    Each
    2 Positions with Tab Terminals
     
    For 1 3/16" High × 13/16" Wide Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-On
    Blank (Top), Blank (Bottom)16 amp @ 125V AC, 5 amp @ 30V DC250V AC, 72V DCBlack, Red7194K32000000
     
    2 Positions with Wire Leads
     
    For 1 3/16" High × 13/16" Wide Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-On
    Blank (Top), Blank (Bottom)16 amp @ 120V AC, 5 amp @ 24V DC250V AC, 72V DC612"Black7194K5700000
     

    Miniature Panel-Mount Push-Button Switches

    Image of Product. 6 mm with 6 Terminals. Front orientation. For 6 mm Diameter Panel Cutouts. Miniature Panel-Mount Push-Button Switches, 6 Terminals.

    6 mm

    with 6

    Terminals

    Sized for 4 mm or 6 mm panel cutouts, these switches are often used with circuit boards to control electronics. They actuate with a quick push. Choose switches based on their actuator color for an easy way to tell them apart.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    Actuator
    Color
    Each
    Metal Actuator Base with Solder Connection
     
    For 6 mm ( 1/4") Diameter Panel Cutouts
    22 Off or 2 On
    Momentary
    6DPDT
    1 amp @ 120V AC/28V DC120V AC
    28V DC
    0.12"0.72"White7400K72000000
     
    Metal Actuator Base with Solder Connection and Push Reset
     
    For 6 mm ( 1/4") Diameter Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    6 amp @ 120V AC/28V DC120V AC
    28V DC
    0.38"0.76"Black7400K10300000
     

    High-Current Rocker Switches

    Image of Product. Front orientation. Rocker Switches. High-Current Rocker Switches.
    Able to withstand high currents, these switches are often used with motors and pumps.
    On-On—Switches with an on-on position designation alternate power between sets of terminals.
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Position
    Designation
    Color
    Switching Current
    @ Voltage
    Max.
    Voltage
    Mounting Fasteners
    Included
    Each
    2 Positions with Screw Terminals
     
    For 1 7/16" High × 15/16" Wide Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-On
    White30 amp @ 125V AC250V ACYes7165K24000000
     
    3 Positions with Screw Terminals
     
    For 1 7/16" High × 15/16" Wide Panel Cutouts
    22 Off or 2 On
    Maintained
    6DPDT
    On-Off-On
    White30 amp @ 125V AC250V ACYes7165K2500000
    22 Off or 2 On
    Maintained
    6DPDT
    On-Off-On
    White30 amp @ 30V DC125V DCYes7165K3200000
     

    3/4" Panel-Mount Key Switches

    Image of Product. Front orientation. Key Switches. 3/4" Panel-Mount Key Switches, Tab Wire Connection.

    Tab Wire

    Connection

    Prevent accidental activation and limit access—these switches require a key to turn circuits on or off. All fit into a standard panel cutout.
    Keyed Alike—Keyed alike switches all open with the same key.
    Key Switches
    Replacement Keys
    No. of Circuits
    Controlled
    Switch Starting
    Position
    Switch
    Action
    No. of
    Terminals
    Switch
    Designation
    Switching Current
    @ Voltage
    Max. Voltage
    Dia.
    Dp. Behind
    Panel
    No. of Keys
    Included
    Key Removal
    Position
    Each
    Each
    2 Positions with Metal Actuator Base
     
    Keyed Alike with Tab Wire Connection
    22 Off or 2 On
    Maintained
    6DPDT
    4 amp @ 125V AC/24V DC125V AC
    28V DC
    7/8"1 1/16"2Center7278K140000007278K400000
    22 Off or 2 On
    Maintained
    6DPDT
    4 amp @ 125V AC/24V DC125V AC
    28V DC
    7/8"1 1/16"2Center, Right7278K15000007278K50000
     
    3 Positions with Metal Actuator Base
     
    Keyed Alike with Tab Wire Connection
    22 Off or 2 On
    Maintained
    8DPDT
    4 amp @ 125V AC/24V DC125V AC
    28V DC
    7/8"1 1/16"2Center7278K1700000———0
     

    Manual Transfer Switches

    Image of Product. Front orientation. Transfer Switches. Manual Transfer Switches, NEMA 1.
    Image of Product. Front orientation. Transfer Switches. Manual Transfer Switches, NEMA 1 with NEMA 3R Power Inlet Box.
    Image of Product. Front orientation. Transfer Switches. Manual Transfer Switches, NEMA 3R.

    NEMA 1

    NEMA 1 with NEMA 3R

    Power Inlet Box

    NEMA 3R

    If there’s a power outage, flip the toggle for each circuit on these switches to backup power. Each circuit can also be turned off completely. To prevent injury and damage to your generators, they are open transition, meaning the contacts disconnect from one power source before connecting to another. This is also known as break-before-make switching.
    Use them with a portable generator.
    NEMA 1—NEMA 1 switches should be used indoors.
    NEMA 1 with NEMA 3R Power Inlet Box—NEMA 1 switches with a power inlet box create a connection point between the switch and a portable generator. These switches should be used indoors. But their inlet box is rated NEMA 3R, so it can be mounted on the outside of an exterior wall.
    NEMA 3R—NEMA 3R switches can be used outdoors since they seal out rain, snow, and sleet.
    Key Lock—Switches with a key lock prevent unauthorized changes to the switch.
    Housing
    Mounting
    Max. Power,
    W
    Switching Current
    (No. of Switches)
    Circuit Breaker Breakthrough
    Current, amp
    Electrical
    Phase
    Housing Material
    Ht.
    Wd.
    Dp.
    Generator Connection
    NEMA Type
    Generator Connection
    California Std. Style
    Power Cord
    Lg., ft.
    Fasteners
    Included
    No. of
    Holes
    Hole
    Dia.
    Features
    Certification
    Specs. Met
    Each
    NEMA 1
     
    10 Circuits Controlled
    7,50030 amp @ 240V AC (1 DPDT)
    20 amp @ 240V AC (1 DPDT)
    15 amp @ 120V AC (6 SPDT)
    10,000SinglePowder-Coated Steel11 1/4"11 3/4"4 3/4"L14-30
    Yes51/4"UL Listed
    UL 1008, NEC Article 7024272N180000000
     
    NEMA 1 with NEMA 3R Power Inlet Box
     
    6 Circuits Controlled
    7,50020 amp @ 240V AC (1 DPDT)
    15 amp @ 120V AC (4 SPDT)
    10,000SinglePowder-Coated Steel12"8 3/4"6"L14-30
    10Yes51/4"UL Listed
    UL 1008, NEC Article 7024272N11000000
     
    10 Circuits Controlled
    7,50020 amp @ 240V AC (1 DPDT)
    20 amp @ 120V AC (2 SPDT)
    15 amp @ 120V AC (6 SPDT)
    10,000SinglePowder-Coated Steel11 1/4"11 3/4"4 3/4"L14-30
    10Yes51/4"UL Listed
    UL 1008, NEC Article 7024272N12000000
     
    NEMA 3R
     
    10 Circuits Controlled
    7,50020 amp @ 240V AC (1 DPDT)
    20 amp @ 120V AC (2 SPDT)
    15 amp @ 120V AC (6 SPDT)
    10,000SinglePowder-Coated Steel12 3/4"12"5"L14-30
    Yes51/4"Key LockUL Listed
    UL 1008, NEC Article 7024272N14000000
    12,50020 amp @ 240V AC (1 DPDT)
    20 amp @ 120V AC (2 SPDT)
    15 amp @ 120V AC (6 SPDT)
    10,000SinglePowder-Coated Steel12 3/4"12"5"CS6375Yes51/4"Key LockUL Listed
    UL 1008, NEC Article 7024272N16000000
     

    Ground-Fault Monitoring Relays

    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Ground-Fault Monitoring Relays, Screw Terminals.
    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Ground-Fault Monitoring Relays, Screw Terminals, Knob Adjustment.

    Screw Terminals

    Screw Terminals

    Knob Adjustment

    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Ground-Fault Monitoring Relays, Screw Terminals with IO-Link.
    Image of Attribute. Front orientation. Contains Annotated. Monitoring Relays. Ground-Fault Monitoring Relays, Spring-Clamp Terminals with IO-Link.

    Screw Terminals with

    IO-Link

    Spring-Clamp

    Terminals with

    IO-Link

    Detect and mitigate ground faults to prevent harm to equipment, circuits, and people. These relays monitor the differential between incoming and outgoing current, also known as residual current. When the balance is off, they trip and cut power to the circuit. These relays are highly sensitive, so you can trust them to de-energize faulty circuits before a minor issue becomes a major one. Rated IP20, they have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
    These relays require a current-indicating ring (sold separately) to operate. Choose a ring that is large enough for your lines to pass through. Feed the lines of the circuit through the center of the ring and connect the indicating ring output to the relay.
    Spring-Clamp-Terminal Wire Connection—Relays with spring-clamp terminals connect and disconnect to wire without screws. Because they don’t have screws, there’s less of a risk that they will loosen over time, even when they’re under vibration.
    IO-Link Communication Protocol—Relays with IO-Link can be programmed, monitored, and reset remotely by connecting them to a programmable logic controller (PLC), human-machine interface (HMI), or computer. If you want to program them locally, they have a keypad.
    Knob Adjustment—Relays with knob adjustments have knobs right on the front where you can set your trip current.
    LED Indicator—Relays with an LED indicator show the status of your relay, so you know it is wired correctly and when it is actuated.
    No. of
    Terminals
    Input Voltage
    Trip Current
    Setting, amp
    Trip Current,
    amp
    Trip Time,
    sec.
    Switching Current
    @ Voltage
    Max. Switching
    Voltage
    Adjustment Mechanism
    Ht.
    Wd.
    Dp.
    Features
    Each
    Screw Terminals
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    1224V AC, 48V AC, 120V AC, 240V AC0.0305 amp @ 240V AC
    5 amp @ 24V DC
    250V AC
    24V DC
    3.2"1.4"2.6"LED Indicator8121N1010000000
    1224V AC, 48V AC, 120V AC, 240V AC0.305 amp @ 240V AC
    5 amp @ 24V DC
    250V AC
    24V DC
    3.2"1.4"2.6"LED Indicator8121N102000000
    1224V AC, 48V AC, 120V AC, 240V AC0.03 to 50 to 55 amp @ 240V AC
    5 amp @ 24V DC
    250V AC
    24V DC
    Knob3.2"1.4"2.8"LED Indicator8121N103000000
    1224V AC, 48V AC, 120V AC, 240V AC0.3 to 300 to 55 amp @ 240V AC
    5 amp @ 24V DC
    250V AC
    24V DC
    Knob3.2"1.4"2.8"LED Indicator8121N104000000
     
    Screw Terminals with IO-Link
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    1224V DC0.03 to 400 to 9993 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad4"0.9"3.6"Remote Reset8121N109000000
     
    Spring-Clamp Terminals with IO-Link
     
    2 Circuits Controlled with 2 Off or 2 On—DPDT
    1224V DC0.03 to 400 to 9993 amp @ 240V AC
    1 amp @ 24V DC
    400V AC
    250V DC
    External Controller, Keypad4.1"0.9"3.6"Remote Reset8121N111000000
     
    Current Indicating Rings