Choosing an Electrical Switch
More
30 mm Emergency Stop Panel-Mount Push-Button Switches
Immediately cut power with a single push. These switches are rated for protection from low-pressure streams of water and oil/coolant spraying. They have positive force contacts that will open a circuit when actuated even if a spring fails or the contacts stick. Mount them in a standard panel cutout.
Illuminated switches are visible in low light. They include a bulb. If wiring the switch and the bulb to the same circuit, the circuit voltage must not exceed bulb voltage.
Turn twist switches back on by twisting the button and pull switches by pulling it. Add an optional lockout (sold separately) on either kind to cover the button and prevent changes to its position.
Additional contact blocks (sold separately) can be added to control more circuits or replace the included contact blocks.



No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Actuator Color | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | For Max. No. of Contact Blocks | Choose a Bulb Voltage | Each | |
Metal Base with Screw Terminals | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pull Reset | |||||||||||||
1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 1 1/2" | 8 | __ | 00000000 | 000000 |
1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 2 1/4" | 1 1/2" | 8 | __ | 00000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 1 1/2" | 8 | __ | 00000000 | 000000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 1 1/2" | 8 | __ | 00000000 | 000000 |
Twist Reset | |||||||||||||
1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 1 1/2" | 8 | __ | 00000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 1 1/2" | 8 | __ | 00000000 | 000000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 1 1/2" | 8 | __ | 00000000 | 000000 |
Metal Base with Screw Terminals—Illuminated | |||||||||||||
Pull Reset | |||||||||||||
1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 4 | SPST-NO | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 2 1/16" | 4 | 0000000 | 000000 | |
1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | SPST-NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 2 1/16" | 4 | 00000000 | 000000 | |
1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | SPST-NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 2 1/16" | 4 | 240V AC/240V DC | 00000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-1NO/1NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 2 15/16" | 4 | 0000000 | 000000 | |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 6 | DPST-NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 2 15/16" | 4 | 0000000 | 000000 | |
Plastic Base with Screw Terminals | |||||||||||||
Pull Reset | |||||||||||||
1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 1 1/2" | 8 | __ | 00000000 | 00000 |
1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 2 1/4" | 1 1/2" | 8 | __ | 00000000 | 000000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 1 1/2" | 8 | __ | 00000000 | 000000 |
Twist Reset | |||||||||||||
1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 1 1/2" | 8 | __ | 00000000 | 00000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 1 1/2" | 8 | __ | 00000000 | 000000 |
2 | 2 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-NC | Red | 6 A @ 120 V AC, 5 A @ 24 V DC | 250V DC 600V AC | 1 1/2" | 1 1/2" | 8 | __ | 00000000 | 000000 |

No. of Circuits Controlled | Switch Starting Position | No. of Terminals | Industry Designation | Specifications Met | Each | |
For 1 1/2" and 2 1/4" Diameter Switches | ||||||
---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) | 2 | SPST-NO | UL Listed, CSA Certified, CE Marked, C-UL Listed, UL 508, EN 60947-5-1, EN 60947-1 | 00000000 | 000000 |
1 | 1 On (Normally Closed) | 2 | SPST-NC | UL Listed, CSA Certified, CE Marked, C-UL Listed, UL 508, EN 60947-5-1, EN 60947-1 | 00000000 | 00000 |

Pull Reset | Twist Reset | |||||||
---|---|---|---|---|---|---|---|---|
Actuator Clarity | Actuator Color | Bulb Type | Bulb Color | Choose a Bulb Voltage | Each | Each | ||
Metal Base—Not Illuminated | ||||||||
Opaque | Red | __ | __ | __ | 00000000 | 000000 | 00000000 | 000000 |
Metal Base—Illuminated | ||||||||
Clear | Red | LED | Red | 24V AC/24V DC, 120V AC/120V DC, 240V AC/240V DC | 0000000 | 000000 | 000000 | 00 |
Plastic Base—Not Illuminated | ||||||||
Opaque | Red | __ | __ | __ | 00000000 | 00000 | 00000000 | 00000 |

Bulb | |||||||||
---|---|---|---|---|---|---|---|---|---|
Voltage | Shape Number | Diameter | Overall Length | Bulb Material | Color | Light Technology | Rated Life, hrs. | Each | |
For 1 1/2" Diameter Switches | |||||||||
For Switches with 24V AC/24V DC Bulb | |||||||||
24V AC, 24V DC | T3 1/4 | 3/8" | 1 1/8" | Plastic | Red | LED | 100,000 | 00000000 | 000000 |
For Switches with 120V AC/120V DC Bulb | |||||||||
130V AC, 130V DC | T3 1/4 | 3/8" | 1 1/8" | Plastic | Red | LED | 100,000 | 00000000 | 00000 |

For Maximum Padlock Shackle Diameter | Each | |
1/4" | 00000000 | 000000 |
Hazardous Location 30 mm Panel-Mount Lever Switches
Made for areas where ignitable gas and vapor may be present, these switches have a housing that seals in anything that could spark flammable material. You'll know they're safe because they're NEC Class 1, Division 2, Groups A, B, C, and D certified for hazardous locations. They're also UL and C-UL listed and CSA certified. They require you to grip and twist a lever to turn them on or off, so they won’t accidentally actuate if you bump into them. Mount into a standard panel cutout.
Additional contact blocks (sold separately) can be added to control more circuits, or to replace the included contact block.
For technical drawings and 3-D models, click on a part number.

Lever Lg. | No. of Circuits Controlled | Switch Starting Position | Switch Action | No. of Terminals | Industry Designation | Switching Current @ Voltage | Max. Voltage | Dia. | Dp. Behind Panel | For Max. No. of Contact Blocks | Each | |
2 Position | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
With Screw Terminals | ||||||||||||
1 1/16" | 1 | 1 Off (Normally Open) | Springs Back (Momentary) | 2 | SPST-NO | 1.5 A @120 V AC, 0.55 A @ 125 V DC | 600V AC 300V DC | 1 3/8" | 3 1/16" | 2 | 0000000 | 0000000 |
1 1/16" | 1 | 1 Off (Normally Open) | Stays Switched (Maintained) | 2 | SPST-NO | 1.5 A @120 V AC, 0.55 A @ 125 V DC | 600V AC 300V DC | 1 3/8" | 3 1/16" | 2 | 0000000 | 000000 |
1 1/16" | 1 | 1 On (Normally Closed) | Springs Back (Momentary) | 2 | SPST-NC | 1.5 A @120 V AC, 0.55 A @ 125 V DC | 600V AC 300V DC | 1 3/8" | 3 1/16" | 2 | 0000000 | 000000 |
1 1/16" | 1 | 1 On (Normally Closed) | Stays Switched (Maintained) | 2 | SPST-NC | 1.5 A @120 V AC, 0.55 A @ 125 V DC | 600V AC 300V DC | 1 3/8" | 3 1/16" | 2 | 0000000 | 000000 |
1 1/16" | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 6 A @120 V AC, 1.1 A @ 125 V DC | 600V AC 300V DC | 1 3/8" | 3 1/16" | 2 | 0000000 | 000000 |
3 Position | ||||||||||||
With Screw Terminals | ||||||||||||
1 1/16" | 2 | 2 Off (Normally Open) | Stays Switched (Maintained) | 4 | DPST-NO | 1.5 A @120 V AC, 0.55 A @ 125 V DC | 600V AC 300V DC | 1 3/8" | 3 1/16" | 2 | 0000000 | 000000 |
1 1/16" | 2 | 1 Off (Normally Open) and 1 On (Normally Closed) | Stays Switched (Maintained) | 4 | DPST-1NO/1NC | 6 A @120 V AC, 1.1 A @ 125 V DC | 600V AC 300V DC | 1 3/8" | 3 1/16" | 2 | 0000000 | 000000 |
Contact Blocks for Manual Switches

Make or break an electrical circuit. These contact blocks mount to manual switches and transmit an electrical signal when the switch actuator is engaged. You can stack multiple blocks, so a single switch can control several circuits. This is helpful in setups that require multiple systems to turn on or off at the same time. For example, the switch on a conveyor line could turn off the conveyor and turn on a diverter and alarm.
No. of Circuits Controlled | Switch Starting Position | No. of Terminals | Industry Designation | Wire Connection Type | For Switch Manufacturer Series | Each | |
C3 Controls | |||||||
---|---|---|---|---|---|---|---|
1 | 1 Off (Normally Open) | 2 | SPST-NO | Screw Terminals | FVPPM, PBO, PTR, RLPPM | 00000000 | 000000 |
1 | 1 On (Normally Closed) | 2 | SPST-NC | Screw Terminals | FVPPM, PBO, PTR, RLPPM | 00000000 | 00000 |
2 | 2 Off (Normally Open) | 4 | DPST-NO | Screw Terminals | 22PP, 22PB | 0000000 | 00000 |
2 | 1 Off (Normally Open) and 1 On (Normally Closed) | 4 | DPST-1NO/1NC | Screw Terminals | 22PP, 22PB | 0000000 | 00000 |
Harsh Environment Potentiometers

Rated NEMA 13, these potentiometers protect against debris and splashing oil and coolant. Also known as variable output switches, they vary electrical flow to control speed, volume, and light intensity.
NEMA 4X rated potentiometers withstand weather, washdowns, and corrosion.
For technical drawings and 3-D models, click on a part number.
Actuator | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Wattage @ Voltage | Max. Voltage | For Panel Cutout Dia. | Dp. Behind Panel | No. of Turns | Dia. | Material | Wire Connection Type | Environmental Rating | Specifications Met | Choose a Max. Resistance | Each | |
Plastic | ||||||||||||
2 W @ 120 V AC/ 2 W @ 24 V DC | 500V AC/500V DC | 1 3/16" (30 mm) | 2 1/8" | 1 | 1 1/8" | Plastic | Screw Terminals | NEMA 4X, NEMA 13, IP65 | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |