Matching Flow Diagrams to Replace an Air Directional Control Valve
More
Choosing an Air Directional Control Valve
More
Single-Action Mechanically Operated Air Directional Control Valves
A simple automation solution that requires no programming, these valves are activated when an object, such as a box rolling on a conveyor, pushes the actuator. Also known as 3-way and 3/2 valves, they create one action, such as extending a cylinder. Valves direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by spring, so they go back to their starting position as soon as the actuator is released. In the off position, they exhaust air pressure from the system, allowing equipment to reset so the action can be repeated.
Normally closed valves block airflow until actuated.
Valves that are both normally closed and normally open can be installed to block airflow, or allow air to flow until actuated.
Valves with a one-direction actuator are activated by objects from one side.
Valves with a two-direction actuator are activated by objects from both sides.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve. When selecting between valves with the same port size, choose the valve with the higher flow coefficient to ensure it provides enough airflow to operate your system.
For technical drawings and 3-D models, click on a part number.
O'all | For Panel Cutout | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Actuation Force, lbs. | No. of Flow Ports | For Inlet Tube ID | For Outlet Tube ID | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating | Lg. | Wd. | Ht. | Lg. | Wd. | Mounting Fasteners Included | Each | ||
One-Direction Actuator | |||||||||||||||||
B | 1.35 | 3 | 2.5 mm | 2.5 mm | Barbed | 1.6 | 0.05 | 0-116 | Not Rated | 27.8mm | 11mm | 41.3mm | 28.6mm | 9.5mm | No | 0000000 | 000000 |
Two-Direction Actuator | |||||||||||||||||
B | 1.35 | 3 | 2.5 mm | 2.5 mm | Barbed | 1.6 | 0.05 | 0-116 | Not Rated | 27.8mm | 11mm | 31.8mm | 28.6mm | 9.5mm | No | 0000000 | 00000 |
O'all | For Panel Cutout | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Actuation Force, lbs. | No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Lg. | Wd. | Ht. | Dia. | Lg. | Wd. | Mounting Fasteners Included | Each | ||
One-Direction Actuator | ||||||||||||||||||
C | 1 | 3 | 1/8 NPT | 1/8 NPT | Threaded | 6 | 0.11 | 0-120 | 29.9 | 2 1/4" | 3/4" | 2 1/8" | __ | 1 3/4" | 3/4" | No | 0000000 | 000000 |
E | 2.8 | 3 | 1/8 NPT | 1/8 NPT | Threaded | 6 | 0.11 | 0-120 | 29.9 | 2 1/8" | 1 3/4" | 4 1/4" | __ | 1 3/4" | 3/4" | No | 0000000 | 000000 |
Two-Direction Actuator | ||||||||||||||||||
A | 1.2 | 3 | 1/8 NPT | 1/8 NPT | Threaded | 6 | 0.11 | 0-120 | 29.9 | 2 1/4" | 3/4" | 1 1/4" | __ | 1 3/4" | 3/4" | No | 0000000 | 00000 |
C | 1 | 3 | 1/8 NPT | 1/8 NPT | Threaded | 6 | 0.11 | 0-120 | 29.9 | 2 1/4" | 3/4" | 1 5/8" | __ | 1 3/4" | 3/4" | No | 0000000 | 00000 |
D | 1.57 | 3 | 1/8 BSPP | 1/8 BSPP | Threaded | 4.94 | 0.12 | 0-120 | 28.5 | 40.5mm | 38mm | 78mm | __ | 19mm | 19mm | No | 0000000 | 000000 |
F | 7 | 3 | 1/8 NPT | 1/8 NPT | Threaded | 19 | 0.34 | 0-150 | 26.5 | 2 3/8" | 7/8" | 4" | __ | 1 3/8" | 7/8" | No | 0000000 | 000000 |
F | 10.1 | 3 | 1/4 NPT | 1/4 NPT | Threaded | 55 | 0.98 | 0-150 | 26.5 | 3" | 1 1/8" | 4 7/8" | __ | 1 3/8" | 7/8" | No | 0000000 | 000000 |
G | 11 | 3 | 1/4 NPTF | 1/4 NPTF | Threaded | 53 | 1.6 | 0-150 | 29 | 2 1/4" | 3" | 6 1/8" | __ | 2 1/4" | 1 3/8" | No | 0000000 | 000000 |
H | 2.5 | 3 | 1/8 NPT | 1/8 NPT | Threaded | 6 | 0.11 | 0-120 | 29.9 | 1 3/4" | 3/4" | 1" | 1/8" | 1 3/4" | 3/4" | No | 0000000 | 00000 |
J | 2.5 | 3 | 1/8 NPT | 1/8 NPT | Threaded | 6 | 0.11 | 0-120 | 29.9 | 1 3/4" | 3/4" | 2" | 1/2" | 1 3/4" | 3/4" | Yes | 0000000 | 00000 |
K | 18 | 3 | 1/4 NPTF | 1/4 NPTF | Threaded | 53 | 1.6 | 0-150 | 29 | 2 1/4" | 1 3/8" | 5 1/8" | __ | 2 1/4" | 1 3/8" | No | 0000000 | 000000 |
L | 2.8 | 3 | 1/8 NPT | 1/8 NPT | Threaded | 6 | 0.11 | 0-120 | 29.9 | 1 3/4" | 3/4" | 2 1/4" | 1/2" | 1 3/4" | 3/4" | Yes | 0000000 | 000000 |
M | 1.57 | 3 | 1/8 BSPP | 1/8 BSPP | Threaded | 4.23 | 0.12 | 53-120 | Not Rated | 36mm | 18mm | 220mm | 19mm | __ | __ | No | 0000000 | 000000 |
N | 2.5 | 3 | 1/8 NPT | 1/8 NPT | Threaded | 6 | 0.11 | 0-120 | 29.9 | 1 3/4" | 3/4" | 1 3/4" | 1/2" | 1 3/4" | 3/4" | Yes | 0000000 | 00000 |
Two-Speed Two-Action Mechanically Operated Air Directional Control Valves
Often used to extend and then retract a cylinder at different speeds, these valves create two actions and have two exhaust ports, which allows you to control the speed of each action by attaching a flow control valve to each exhaust port. A simple automation solution that requires no programming, they activate when an object, such as a box rolling on a conveyor, pushes the actuator. They direct airflow from the inlet to your equipment and exhaust return airflow to create motion. Return actuation is by spring, so they go back to their original position as soon the actuator is released. Also known as 4-way and 5/2 valves.
Valves with a one-direction actuator are activated by objects from one side.
Valves with a two-direction actuator are activated by objects from both sides.
NPTF (Dryseal) threads are compatible with NPT threads.
Flow coefficient (Cv) is a measurement that indicates how much airflow can pass through a valve.
For technical drawings and 3-D models, click on a part number.
Overall | For Panel Cutout | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Actuation Force, lbs. | No. of Flow Ports | Inlet Size | Outlet Size | Exhaust Connection Type | Max. Flow Rate, scfm @ 100 psi | Flow Coefficient (Cv) | Pressure Range, psi | Vacuum Rating, in. of Hg | Lg. | Wd. | Ht. | Dia. | Lg. | Wd. | Mounting Fasteners Included | Each | ||
Threaded Female Inlet × Threaded Female Outlet | ||||||||||||||||||
One-Direction Actuator | ||||||||||||||||||
C | 0.3 | 5 | 1/8 NPTF | 1/8 NPTF | Threaded | 14 | 0.24 | 25-125 | Not Rated | 2 1/8" | 3/4" | 3 3/8" | __ | 1 1/4" | 1 1/2" | No | 00000000 | 0000000 |
Two-Direction Actuator | ||||||||||||||||||
A | 0.3 | 5 | 1/8 NPTF | 1/8 NPTF | Threaded | 14 | 0.24 | 25-125 | Not Rated | 2 1/4" | 3/4" | 2 5/8" | __ | 1 1/4" | 1 1/2" | No | 00000000 | 000000 |
B | 0.3 | 5 | 1/8 NPTF | 1/8 NPTF | Threaded | 14 | 0.24 | 25-125 | Not Rated | 2 1/4" | 3/4" | 3" | __ | 1 1/4" | 1 1/2" | No | 00000000 | 000000 |
D | 11 | 5 | 1/4 NPTF | 1/4 NPTF | Threaded | 53 | 1.6 | 0-150 | 29 | 2 1/4" | 3" | 7 1/4" | __ | 2 1/4" | 1 3/8" | No | 0000000 | 000000 |
E | 0.8 | 5 | 1/8 NPTF | 1/8 NPTF | Threaded | 14 | 0.24 | 25-125 | Not Rated | 1 1/4" | 3/4" | 2 3/8" | 1/2" | __ | __ | No | 0000000 | 000000 |
F | 0.8 | 5 | 1/8 NPTF | 1/8 NPTF | Threaded | 14 | 0.24 | 25-125 | Not Rated | 1 1/4" | 3/4" | 3 1/8" | 1/2" | __ | __ | No | 00000000 | 000000 |
G | 18 | 5 | 1/4 NPTF | 1/4 NPTF | Threaded | 53 | 1.6 | 0-150 | 29 | 2 1/4" | 1 1/4" | 6 1/8" | __ | 2 1/4" | 1 3/8" | No | 0000000 | 000000 |
H | 0.8 | 5 | 1/8 NPTF | 1/8 NPTF | Threaded | 14 | 0.24 | 25-125 | Not Rated | 1 1/4" | 3/4" | 3 1/2" | 1/2" | __ | __ | No | 0000000 | 000000 |
J | 15 | 5 | 1/4 NPT | 1/4 NPT | Threaded | 32.5 | 0.98 | 0-145 | 26.5 | 1 7/8" | 1 1/8" | 5 1/4" | __ | 1 1/8" | 1 1/8" | No | 0000000 | 000000 |
K | 0.3 | 5 | 1/8 NPTF | 1/8 NPTF | Threaded | 14 | 0.24 | 25-125 | Not Rated | 6 1/4" | 3/4" | 3 7/8" | __ | 1 1/4" | 3/4" | No | 00000000 | 000000 |