Cable AWG Cable AWG |
---|
Current Current |
---|
|
|
Specifications Met Specifications Met |
---|
|
Wire Finish Wire Finish |
---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
---|
Environment Environment |
---|
|
Environmental Rating Environmental Rating |
---|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
---|
|
About Wire and Cable
More
Armored Building Cable

- Use For: Buildings
- Flexible
- Temperature Range: 15° to 190° F
- Insulation:
Outer: Aluminum Armor
Inner: PVC Plastic
Also known as metal clad (MC) cable, this cable has metal armor that acts as conduit to protect the THHN building wires. It's often used along the exterior of walls to carry power to outlet boxes. It has an insulated ground wire that is not counted in the cable AWG.
Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment. See About Hazardous Location Environmental Ratings.
For technical drawings and 3-D models, click on a part number.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Industry Designation | Environmental Rating | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Solid Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | ||||||||||||||
14 | 3 | 14/2 | 15 A @ 86° F | 0.44" | Black, Green, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 | |||||
14 | 4 | 14/3 | 15 A @ 86° F | 0.46" | Black, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 | |||||
14 | 5 | 14/4 | 15 A @ 86° F | 0.49" | Black, Blue, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 | |||||
12 | 3 | 12/2 | 20 A @ 86° F | 0.48" | Black, Green, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 | |||||
12 | 4 | 12/3 | 20 A @ 86° F | 0.51" | Black, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 | |||||
12 | 5 | 12/4 | 20 A @ 86° F | 0.54" | Black, Blue, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 | |||||
10 | 3 | 10/2 | 30 A @ 86° F | 0.54" | Black, Green, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 | |||||
10 | 4 | 10/3 | 30 A @ 86° F | 0.58" | Black, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 | |||||
10 | 5 | 10/4 | 30 A @ 86° F | 0.62" | Black, Blue, Green, Red, White | MC, THHN | NEC Class I Division 2 Groups A, B, C, D NEC Class II Division 2 Groups F, G NEC Class III Divisions 1, 2 | UL 1569, Flame Rated VW-1 | 0000000 |
Armored Building Cable with Uninsulated Ground Wire

- Use For: Buildings
- Flexible
- Temperature Range: 15° to 190° F
- Insulation:
Outer: Aluminum Armor
Inner: PVC Plastic
Also known as AC cable, this cable has an uninsulated aluminum ground wire that's in constant contact with the aluminum armor, so it can be used for bonding and grounding. The uninsulated ground wire is not counted in the number of wires. The armor acts as conduit to protect the THHN building wires. It's often used along the exterior of walls to carry power to outlet boxes. All are flame rated VW-1 to meet requirements for preventing the spread of flames based on a timed test with vertically suspended material.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Features | Industry Designation | Specifications Met | 10 ft. | 25 ft. | 50 ft. | 100 ft. | 250 ft. | |
Solid Wire | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | ||||||||||||||
14 | 2 | 14/2 | 15 A @ 86° F | 0.46" | Black, White | Uninsulated Ground Wire | AC, THHN | UL Listed, Flame Rated VW-1 | 0000000 | |||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.48" | Black, Red, White | Uninsulated Ground Wire | AC, THHN | UL Listed, Flame Rated VW-1 | 0000000 | |||||
12 | 2 | 12/2 | 20 A @ 86° F | 0.5" | Black, White | Uninsulated Ground Wire | AC, THHN | UL Listed, Flame Rated VW-1 | 0000000 | |||||
12 | 3 | 12/3 | 20 A @ 86° F | 0.52" | Black, Red, White | Uninsulated Ground Wire | AC, THHN | UL Listed, Flame Rated VW-1 | 0000000 | |||||
10 | 2 | 10/2 | 30 A @ 86° F | 0.56" | Black, White | Uninsulated Ground Wire | AC, THHN | UL Listed, Flame Rated VW-1 | 0000000 | |||||
10 | 3 | 10/3 | 30 A @ 86° F | 0.59" | Black, Red, White | Uninsulated Ground Wire | AC, THHN | UL Listed, Flame Rated VW-1 | 0000000 |
Armored Building Cable with Fittings

- Use For: Buildings
- Flexible
- Temperature Range: -10° to 190° F
- Insulation:
Outer: Steel Armor
Inner: PVC Plastic
Also known as fixture whips, this cable has locknuts and fittings attached to the metal armor to secure to a knockout. The armor acts as conduit to protect the THHN building wires. It has 6" long wire leads for hardwiring to an existing electrical system, and is often used to connect light fixtures.
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Inner Insulation Color | Includes | Industry Designation | Specifications Met | Lg., ft. | Each | |
Solid Wire | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
600V AC | |||||||||||
14 | 3 | 14/3 | 15 A @ 86° F | 0.46" | Black, Green, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 000000 |
14 | 4 | 14/4 | 15 A @ 86° F | 0.49" | Black, Green, Red, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |
14 | 5 | 14/5 | 15 A @ 86° F | 0.92" | Black, Blue, Green, Red, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |
12 | 4 | 12/4 | 20 A @ 86° F | 0.92" | Black, Green, Red, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |
12 | 5 | 12/5 | 20 A @ 86° F | 0.92" | Black, Blue, Green, Red, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |
10 | 3 | 10/3 | 30 A @ 86° F | 0.92" | Black, Green, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |
10 | 5 | 10/5 | 30 A @ 86° F | 0.92" | Black, Blue, Green, Red, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |
Stranded Wire | |||||||||||
600V AC | |||||||||||
12 | 3 | 12/3 | 20 A @ 86° F | 0.52" | Black, Green, White | 1/2 NPT Fittings, Locknuts, 6" Wire Leads | THHN | UL Listed | 6 | 0000000 | 00000 |
Armored Corrosion-Resistant Cable

- Use For: Boats, Motors, Panel and Equipment (Hook-Up), Power Supply
- Flexible
- Temperature Range: -40° to 230° F
- Insulation:
Outer: Chlorinated Polyethylene Plastic
Inner: Braided Bronze Armor, Polyolefin Plastic
A braided bronze armor provides excellent protection against abrasion and other damage. The chlorinated polyethylene insulation resists corrosive chemicals and salt water, and the wires are tin plated for corrosion resistance. This cable also withstands oil and solvents. It’s rated UL 1309 for use as marine shipboard cable.
Per Ft. | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Wire Ga. | No. of Wires | Cable AWG | Current | OD | Outer Insulation Color | Inner Insulation Color | Specifications Met | Length, ft. | 1-99 | 100-Up | |
Stranded Wire | |||||||||||
600V AC | |||||||||||
16 | 3 | 16/3 | 18 A @ 86° F | 0.52" | Black | Black, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 00000 | 00000 | |
16 | 4 | 16/4 | 14 A @ 86° F | 0.58" | Black | Black, Green, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 0000 | 0000 | |
14 | 3 | 14/3 | 20 A @ 86° F | 0.58" | Black | Black, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 0000 | 0000 | |
14 | 4 | 14/4 | 16 A @ 86° F | 0.62" | Black | Black, Green, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 0000 | 0000 | |
12 | 3 | 12/3 | 25 A @ 86° F | 0.63" | Black | Black, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 0000 | 0000 | |
12 | 4 | 12/4 | 20 A @ 86° F | 0.67" | Black | Black, Green, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 0000 | 0000 | |
10 | 3 | 10/3 | 35 A @ 86° F | 0.67" | Black | Black, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 00000 | 00000 | |
10 | 4 | 10/4 | 28 A @ 86° F | 0.73" | Black | Black, Green, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 00000 | 00000 | |
8 | 4 | 8/4 | 40 A @ 86° F | 0.92" | Black | Black, Green, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 00000 | 00000 | |
6 | 4 | 6/4 | 52 A @ 86° F | 1.02" | Black | Black, Green, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 00000 | 00000 | |
4 | 4 | 4/4 | 68 A @ 86° F | 1.26" | Black | Black, Green, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 00000 | 00000 | |
2 | 4 | 2/4 | 92 A @ 86° F | 1.42" | Black | Black, Green, Red, White | UL Listed, UL 1309, CSA Certified | 0000000 | 00000 | 00000 |
Stainless Steel Armored Micro M12 Cords
Step on or roll carts and platform trucks over these M12 cords without crushing them. A protective layer of stainless steel makes these the most crush- and abrasion-resistant M12 cords we offer. It also prevents damage from pests that chew through cords. The stainless steel and PVC outer layer keep moisture from corroding the cord, so they can be used outdoors and near chemicals as well. Despite the stainless steel covering, these cords are still flexible enough to route around equipment. Threaded ends create a tight connection that seals out contaminants and won’t shake loose from the vibration of automated machines.
These cords have a standardized code layout to reduce the chances of accidentally mis-mating them. All are A-coded to send signal and power to AC and DC devices. A-coded cords are often used with sensors, actuators, and motors in automated systems. They also connect devices to IO Link controllers and within fieldbus systems, such as Profibus and DeviceNet.
When mated or capped, these cords meet IP ratings. IP67 cords withstand temporary submersion. IP69 cords are protected from dust and high-pressure, high-temperature washdowns.
Add caps to protect connectors and maintain their IP ratings when not in use.
Note: Sockets may have extra holes on the face that are not used.
For technical drawings and 3-D models, click on a part number.




No. of Poles | No. of Keyways | Coding | Face Dia. | Lg., ft. | Current, A | Voltage | Housing Thread Size | Wire Gauge | Cord OD | Cord Insulation Material | Cord Outer Insulation Material | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
Plug (External Thread) × Socket (Internal Thread) | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
4 | 1 | A | 0.3" | 6 1/2 | 4 | 300V AC/ 300V DC | M12 | 22 | 0.4" | PVC Plastic | PVC-Covered Stainless Steel Armor | -40° to 175° | IP69 | UL Listed, C-UL Listed, CE Marked | 0000000 | 0000000 |
4 | 1 | A | 0.3" | 16 | 4 | 300V AC/ 300V DC | M12 | 22 | 0.4" | PVC Plastic | PVC-Covered Stainless Steel Armor | -40° to 175° | IP69 | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
4 | 1 | A | 0.3" | 32 1/2 | 4 | 300V AC/ 300V DC | M12 | 22 | 0.4" | PVC Plastic | PVC-Covered Stainless Steel Armor | -40° to 175° | IP69 | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
5 | 1 | A | 0.3" | 6 1/2 | 4 | 300V AC/ 300V DC | M12 | 22 | 0.4" | PVC Plastic | PVC-Covered Stainless Steel Armor | -40° to 175° | IP69 | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
5 | 1 | A | 0.3" | 16 | 4 | 300V AC/ 300V DC | M12 | 22 | 0.4" | PVC Plastic | PVC-Covered Stainless Steel Armor | -40° to 175° | IP69 | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |
5 | 1 | A | 0.3" | 32 1/2 | 4 | 300V AC/ 300V DC | M12 | 22 | 0.4" | PVC Plastic | PVC-Covered Stainless Steel Armor | -40° to 175° | IP69 | UL Listed, C-UL Listed, CE Marked | 0000000 | 000000 |