High-Flow Metering Pumps for Chemicals

For high-volume chemical sampling and draining, these pumps have a powerful motor that enables them to move 2,592 gallons of liquid per day. They're commonly used with ammonia, acid-washing solutions, and cleaning fluids. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are self-priming and create a suction force to draw liquid upward. Mount up to 15 feet above your liquid source. They can run dry. Do not use with solids.
Intake | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gal./day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | For Tube ID | Tube Connection Type | For Tube ID | Tube Connection Type | Lg. | Wd. | Ht. | Includes | Each | |
120V AC, Single Phase | |||||||||||||||
Plug | |||||||||||||||
2,592 | 20 | 1,000 | 35° to 160° | 1/4 hp | 3.1 | 1/2" | Barbed | 1/2" | Barbed | 10" | 5 1/2" | 10" | 10 5/8" Lg. of 1/2" ID Tygon Tubing (Shore A61) | 0000000 | 0000000 |
Calibration Columns

Calibrate the flow rate of metering pumps. A graduated scale with zero at the top lets you easily see how much fluid is lost over the course of a one-minute test. This will tell you your pump’s flow rate. Periodic testing helps alert you to issues in your system, such as worn or dirty valves. Checking the flow rate after performing maintenance ensures your pump is working properly.
Install the column between your reservoir and pump. They require shutoff access to your reservoir and an on/off valve (not included) at the point where they connect to your system. To start the test, open the on/off valve as the system is running to fill the column with fluid up to the zero mark. Shut off the valve and wait one minute before observing the liquid level in the column. After you've taken the reading, close the on/off valve to the column and reopen access to the reservoir.
Borosilicate glass calibration columns and their fittings stand up to sulfuric acid, hydrochloric acid, and other corrosive chemicals.
For technical drawings and 3-D models, click on a part number.
Volume | Graduations | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Connections | Ht. | Flow Rate Range, gph | gal. | ml | gph | ml/min | Temp. Range, °F | O-Ring Material | Mounting Orientation | For Use With | Each | |
Borosilicate Glass Body with PTFE Plastic Fittings | ||||||||||||
Gallons per Hour, Milliliters per Minute | ||||||||||||
1/2 NPT Female | 13" | 0 to 1.5 | 1.5 | 100 | 0.02 | 1 | 40° to 150° | Fluoroelastomer Rubber | Vertical | Water, Gasoline, Diesel Fuel, Kerosene, Ammonium Hydroxide, Bleach, Chlorine, Citric Acid, Deionized Water, Ethylene Glycol, Fuel Oil, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Methyl Chloride, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide, Sulfuric Acid | 00000000 | 0000000 |
1/2 NPT Female | 16 1/2" | 0 to 4 | 4 | 250 | 0.05 | 2 | 40° to 150° | Fluoroelastomer Rubber | Vertical | Water, Gasoline, Diesel Fuel, Kerosene, Ammonium Hydroxide, Bleach, Chlorine, Citric Acid, Deionized Water, Ethylene Glycol, Fuel Oil, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Methyl Chloride, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide, Sulfuric Acid | 00000000 | 000000 |
3/4 NPT Female | 18" | 0 to 8 | 8 | 500 | 0.05 | 5 | 40° to 150° | Fluoroelastomer Rubber | Vertical | Water, Gasoline, Diesel Fuel, Kerosene, Ammonium Hydroxide, Bleach, Chlorine, Citric Acid, Deionized Water, Ethylene Glycol, Fuel Oil, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Methyl Chloride, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide, Sulfuric Acid | 00000000 | 000000 |
3/4 NPT Female | 29" | 0 to 16 | 16 | 1,000 | 0.125 | 5 | 40° to 150° | Fluoroelastomer Rubber | Vertical | Water, Gasoline, Diesel Fuel, Kerosene, Ammonium Hydroxide, Bleach, Chlorine, Citric Acid, Deionized Water, Ethylene Glycol, Fuel Oil, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Methyl Chloride, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide, Sulfuric Acid | 00000000 | 000000 |
1 NPT Female | 24" | 0 to 32 | 32 | 2,000 | 0.25 | 10 | 40° to 150° | Fluoroelastomer Rubber | Vertical | Water, Gasoline, Diesel Fuel, Kerosene, Ammonium Hydroxide, Bleach, Chlorine, Citric Acid, Deionized Water, Ethylene Glycol, Fuel Oil, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Methyl Chloride, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide, Sulfuric Acid | 00000000 | 00000000 |
1 NPT Female | 39" | 0 to 64 | 64 | 4,000 | 0.25 | 20 | 40° to 150° | Fluoroelastomer Rubber | Vertical | Water, Gasoline, Diesel Fuel, Kerosene, Ammonium Hydroxide, Bleach, Chlorine, Citric Acid, Deionized Water, Ethylene Glycol, Fuel Oil, Hydraulic Oil, Hydrochloric Acid, Isopropyl Alcohol, Methyl Chloride, Motor Oil, Nitric Acid, Paint, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide, Sulfuric Acid | 00000000 | 00000000 |