Shielded Micro M12 Screw-Together Connectors
Block signal interference from nearby devices, such as motors and transmitters, while maintaining a strong, stable connection for M12 threads. The shielding on these connectors maintains signal integrity and minimizes signal loss between equipment. The threaded housing creates a secure connection that withstands the shaking and vibrating of industrial automation.
A-coded, these connectors are often used to connect equipment to IO Link controllers and devices within Profibus, DeviceNet, and other fieldbus systems. They work with both AC and DC devices such as sensors, motors, and light curtains. Poles and keyways on their face adhere to standard coding layouts to reduce the chance you’ll mismatch connections.
Connectors with screw terminals have a screw that you tighten onto wire to connect. Snap-on connectors pierce your wire’s insulation, so you don’t need to strip it.
Connectors with polyurethane outer insulation are halogen free, so they won’t release toxic fumes or cause corrosion in metal. Polyurethane resists chemicals, oil, and UV rays, and is very flexible. It’s good for use in industrial environments and robotics.
All meet IP ratings when either mated or capped. IP65 rated connectors seal out dust and water from low-pressure washdowns. IP66K rated connectors are dust tight and protected from washdowns. IP67 rated connectors are protected from dust and temporary submersion.
Add caps to protect connectors and maintain their IP ratings when not in use.
Note: They may have extra holes on the face that are not used.

Housing Thread | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Type | Temp. Range, °F | Environmental Rating | Each | |
| 5 | A | 0.3" | 60V AC/60V DC | 4A | 22 | 0.24" - 0.31" | Nickel-Plated Brass | M12 | 1 | Metric | -40° to 185° | IP67 | 4490N22 | 000000 |
| 8 | A | 0.3" | 30V AC/30V DC | 2A | 22 | 0.24" - 0.31" | Nickel-Plated Brass | M12 | 1 | Metric | -40° to 185° | IP67 | 4490N23 | 00000 |

Housing Thread | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Housing Material | Size | Pitch, mm | Type | Temp. Range, °F | Environmental Rating | Each | |
9.5 ft. Cable Lead Lg. | |||||||||||||||
| 3 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.2" | Polyurethane Rubber | Nickel-Plated Brass | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 4490N25 | 000000 |
| 4 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.21" | Polyurethane Rubber | Nickel-Plated Brass | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 4490N26 | 00000 |
| 5 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.22" | Polyurethane Rubber | Nickel-Plated Brass | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 4490N27 | 00000 |
| 8 | A | 0.3" | 30V AC/30V DC | 2A | 24 | 0.28" | Polyurethane Rubber | Nickel-Plated Brass | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 4490N28 | 00000 |
16 ft. Cable Lead Lg. | |||||||||||||||
| 3 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.2" | Polyurethane Rubber | Nickel-Plated Brass | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 4490N29 | 00000 |
| 4 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.21" | Polyurethane Rubber | Nickel-Plated Brass | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 4490N31 | 00000 |
| 5 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.22" | Polyurethane Rubber | Nickel-Plated Brass | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 4490N32 | 00000 |
| 8 | A | 0.3" | 30V AC/30V DC | 2A | 24 | 0.28" | Polyurethane Rubber | Nickel-Plated Brass | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 4490N33 | 000000 |

Housing Thread | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Type | Temp. Range, °F | Environmental Rating | Each | |
| 5 | A | 0.3" | 60V AC/60V DC | 4A | 18 | 0.24" - 0.31" | Nickel-Plated Brass | M12 | 1 | Metric | -40° to 185° | IP67 | 4490N11 | 000000 |
| 8 | A | 0.3" | 30V AC/30V DC | 2A | 18 | 0.24" - 0.31" | Nickel-Plated Brass | M12 | 1 | Metric | -40° to 185° | IP67 | 4490N12 | 00000 |

Housing Thread | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Type | Temp. Range, °F | Environmental Rating | Each | |
| 4 | A | 0.3" | 50V AC/50V DC | 4A | 24-22 | 0.18" - 0.35" | Nickel-Plated Brass | M12 | 1 | Metric | -40° to 185° | IP65, IP67 | 4490N24 | 000000 |

Housing Thread | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Housing Material | Size | Pitch, mm | Type | Temp. Range, °F | Environmental Rating | Each | |
9.5 ft. Cable Lead Lg. | |||||||||||||||
| 3 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.2" | Polyurethane Rubber | Nickel-Plated Brass | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 4490N34 | 000000 |
| 4 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.21" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 4490N13 | 00000 |
| 5 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.22" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 4490N15 | 00000 |
| 8 | A | 0.3" | 30V AC/30V DC | 2A | 24 | 0.28" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 4490N17 | 00000 |
| 12 | A | 0.3" | 30V AC/30V DC | 1.5A | 26 | 0.26" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67 | 4490N19 | 000000 |
16 ft. Cable Lead Lg. | |||||||||||||||
| 3 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.2" | Polyurethane Rubber | Nickel-Plated Brass | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 4490N35 | 00000 |
| 4 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.21" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 4490N14 | 00000 |
| 5 | A | 0.3" | 30V AC/30V DC | 4A | 22 | 0.22" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 4490N16 | 00000 |
| 8 | A | 0.3" | 30V AC/30V DC | 2A | 24 | 0.28" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67, IP66K | 4490N18 | 000000 |
| 12 | A | 0.3" | 30V AC/30V DC | 1.5A | 26 | 0.26" | Polyurethane Rubber | Nickel-Plated Zinc | M12 | 1 | Metric | -10° to 175° | IP67 | 4490N21 | 000000 |

| For Thread Size | Material | Each | |
For Sockets with Internal Threads | |||
|---|---|---|---|
| M12 | Anodized Aluminum | 6897K74 | 000000 |
Shielded Nano M8 Connectors
Minimize signal loss between low-current devices with M8 connections. The shielding on these connectors reduces signal interference from nearby devices, such as motors and speed controls. Also known as pico connectors, M8 connectors are often used with 8 mm and smaller proximity switches and photoelectric switches.
To view wiring diagrams, select a part number and click Product Detail.
Receptacles thread into panels and walls, so they work well in stationary or permanent installations.
Connectors with screw terminals hold wire by tightening a screw, so you don’t need to use soldering irons or crimpers.
IP or NEMA rated when mated, all seal out dust. IP66K rated connectors protect against high-pressure washdowns. IP67 rated connectors seal out water from temporary submersion. IP68 rated connectors withstand submersion. NEMA 6P rated connectors protect against weather, washdowns, corrosion, and submersion.

Housing Thread | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Diameter | Voltage | Current, A | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Housing Material | Size | Pitch, mm | Temperature Range, ° F | Environmental Rating | Each | |
6.5 ft. Cable Lead Lg. | ||||||||||||||
| 3 | A | 0.2" | 30V AC/30V DC | 4 | 22 | 0.2" | PVC Plastic | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 3884N13 | 000000 |
| 4 | A | 0.2" | 30V AC/30V DC | 4 | 22 | 0.21" | PVC Plastic | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 3884N15 | 00000 |
16.5 ft. Cable Lead Lg. | ||||||||||||||
| 3 | A | 0.2" | 30V AC/30V DC | 4 | 22 | 0.2" | PVC Plastic | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 3884N14 | 00000 |
| 4 | A | 0.2" | 30V AC/30V DC | 4 | 22 | 0.21" | PVC Plastic | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 3884N16 | 00000 |

Housing Thread | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Diameter | Voltage | Current, A | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Temperature Range, ° F | Environmental Rating | Each | |
| 3 | A | 0.2" | 30V AC/30V DC | 4 | 26-20 | 0.16"-0.22" | Nickel-Plated Brass | M8 | 1 | -40° to 185° | IP67 | 3884N11 | 000000 |
| 4 | A | 0.2" | 30V AC/30V DC | 4 | 26-20 | 0.16"-0.22" | Nickel-Plated Brass | M8 | 1 | -40° to 185° | IP67 | 3884N12 | 00000 |

Housing Thread | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Diameter | Voltage | Current, A | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Housing Material | Size | Pitch, mm | Temperature Range, ° F | Environmental Rating | Each | |
6.5 ft. Cable Lead Lg. | ||||||||||||||
| 3 | A | 0.2" | 30V AC/30V DC | 4 | 22 | 0.2" | PVC Plastic | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 3884N19 | 000000 |
| 4 | A | 0.2" | 30V AC/30V DC | 4 | 22 | 0.21" | PVC Plastic | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 3884N22 | 00000 |
16.5 ft. Cable Lead Lg. | ||||||||||||||
| 3 | A | 0.2" | 30V AC/30V DC | 4 | 22 | 0.2" | PVC Plastic | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 3884N21 | 00000 |
| 4 | A | 0.2" | 30V AC/30V DC | 4 | 22 | 0.21" | PVC Plastic | Polyurethane Rubber | M8 | 1 | -10° to 185° | IP66K, IP67 | 3884N23 | 00000 |

Housing Thread | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Diameter | Voltage | Current, A | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Temperature Range, ° F | Environmental Rating | Each | |
| 3 | A | 0.2" | 30V AC/30V DC | 4 | 26-20 | 0.16"-0.22" | Nickel-Plated Brass | M8 | 1 | -40° to 185° | IP67 | 3884N17 | 000000 |
| 4 | A | 0.2" | 30V AC/30V DC | 4 | 26-20 | 0.16"-0.22" | Nickel-Plated Brass | M8 | 1 | -40° to 185° | IP67 | 3884N18 | 00000 |

Housing Thread | 1 ft. Wire Lead Lg. | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Coding | Face Diameter | Voltage | Current, A | Wire Lead Gauge | Wire Insulation Material | Housing Material | Size | Pitch, mm | Temperature Range, ° F | Environmental Rating | Each | |
| 3 | A | 0.2" | 125V AC/125V DC | 4 | 24 | PVC Plastic | Nickel-Plated Brass | M8 | 1 | 0° to 220° | IP68, NEMA 6P | 3884N24 | 000000 |
| 4 | A | 0.2" | 125V AC/125V DC | 4 | 24 | PVC Plastic | Nickel-Plated Brass | M8 | 1 | 0° to 220° | IP68, NEMA 6P | 3884N25 | 00000 |
Shielded Mini Connectors
Protect against signal interference while sending 2-3 times more current than M12 connectors. These mini connectors have a braided shielding, which blocks interference from nearby devices for a reliable signal. Because they carry a high current, they are often used with automated systems, motors, and pumps. A threaded housing securely mates with other mini connectors and won’t come loose from shaking or vibration. They have a standard pole layout and housing thread size to reduce the chance you’ll mis-mate connectors.
When mated, these connectors meet IP68 and NEMA 6P for protection against dust, submersion, washdowns, and weather.
Caps protect connectors and maintain their IP and NEMA ratings when not in use.
Thread Adapters connect plugs and sockets that both have internal threads.

Housing Thread | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Housing Material | Size | Type | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
6 ft. Lg. Cable Leads | ||||||||||||||
| 2 | 0.55" | 600V AC/600V DC | 13A | 16 | 0.4" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N11 | 000000 |
| 3 | 0.55" | 600V AC/600V DC | 13A | 16 | 0.41" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N13 | 00000 |
| 4 | 0.55" | 600V AC/600V DC | 10A | 16 | 0.45" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N15 | 00000 |
| 5 | 0.55" | 600V AC/600V DC | 8A | 16 | 0.52" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N17 | 000000 |
| 6 | 0.55" | 600V AC/600V DC | 8A | 16 | 0.52" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N19 | 000000 |
12 ft. Lg. Cable Leads | ||||||||||||||
| 2 | 0.55" | 600V AC/600V DC | 13A | 16 | 0.4" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N12 | 00000 |
| 3 | 0.55" | 600V AC/600V DC | 13A | 16 | 0.41" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N14 | 000000 |
| 4 | 0.55" | 600V AC/600V DC | 10A | 16 | 0.45" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N16 | 000000 |
| 5 | 0.55" | 600V AC/600V DC | 8A | 16 | 0.52" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N18 | 000000 |
| 6 | 0.55" | 600V AC/600V DC | 8A | 16 | 0.52" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N21 | 000000 |

Housing Thread | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Face Dia. | Voltage | Current | Wire Lead Gauge | Cable OD | Cable Outer Insulation Material | Housing Material | Size | Type | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
6 ft. Lg. Cable Leads | ||||||||||||||
| 2 | 0.55" | 600V AC/600V DC | 13A | 16 | 0.4" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N22 | 000000 |
| 3 | 0.55" | 600V AC/600V DC | 13A | 16 | 0.41" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N24 | 00000 |
| 4 | 0.55" | 600V AC/600V DC | 10A | 16 | 0.45" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N26 | 00000 |
| 5 | 0.55" | 600V AC/600V DC | 8A | 16 | 0.52" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N28 | 000000 |
| 6 | 0.55" | 600V AC/600V DC | 8A | 16 | 0.52" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N31 | 000000 |
12 ft. Lg. Cable Leads | ||||||||||||||
| 2 | 0.55" | 600V AC/600V DC | 13A | 16 | 0.4" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N23 | 00000 |
| 3 | 0.55" | 600V AC/600V DC | 13A | 16 | 0.41" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N25 | 000000 |
| 4 | 0.55" | 600V AC/600V DC | 10A | 16 | 0.45" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N27 | 00000 |
| 5 | 0.55" | 600V AC/600V DC | 8A | 16 | 0.52" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N29 | 000000 |
| 6 | 0.55" | 600V AC/600V DC | 8A | 16 | 0.52" | PVC Plastic | Polyurethane Rubber | 7/8"-16 | UNS | 0° to 175° | IP68, NEMA 6P | UL Recognized Component, CSA Certified | 7305N32 | 000000 |

Thread | ||||||
|---|---|---|---|---|---|---|
| For Face Dia. | Size | Type | Material | Temp. Range, °F | Each | |
External Thread | ||||||
| 0.55" | 7/8"-16 | UNS | Epoxy-Coated Zinc | 0° to 220° | 69005K21 | 000000 |

Thread | |||||
|---|---|---|---|---|---|
| Size | Type | Material | Temp. Range, °F | Each | |
External Thread | |||||
| 7/8"-16 | UNS | Aluminum | -4° to 190° | 69005K51 | 00000 |
Micro M12 Screw-Together Ethernet Connectors
Unlike traditional RJ45 connectors found in data centers, these connectors stand up to rugged industrial environments since they tightly thread to devices with M12 connections, sealing out contaminants and resisting shaking loose from vibration. Use them to transfer high-speed data between sensors, switches, computers, IO modules, programmable logic controllers (PLCs), and other equipment. They can also power devices as they send data, so you don’t need a separate power cord. But, the device must be Power over Ethernet (PoE) compatible. These connectors are often used with EtherNet/IP, Profinet, and EtherCAT systems. Since they’re shielded, they block signal interference from nearby devices, maintaining their speed and data integrity. Poles and keyways on the face adhere to standard coding layouts to reduce the chance you’ll mismatch connections.
When choosing an Ethernet connector, make sure you match or exceed your network’s category industry designation. These connectors are backward compatible—for example, a Category 6 connector will work in a Category 5 network, but it’ll only run at the Category 5 speed.
A-coded and X-coded connectors send data faster than D-coded connectors, so they’re best for robotics and other systems that run multi-step programs.
Y-coded connectors send both data and power to your device to reduce the number of cables needed.
Adapters create a transition point between an M12 and RJ45 connection. Use them in panels or walls—your tough threaded connection on one side and your control panel and computer or PLC on the other.
90° elbow connectors run your cord along the side of equipment, so they fit behind machines and in tight spaces.
Connectors with a screw-on wire connection, also known as field wireable connectors, do not require special tools like crimpers or soldering irons to attach to cables.
Connectors with polyurethane or TPE insulation resist chemicals, oil, and sunlight for outdoor use. Because they’re flexible, they’re good for jobs with continuous motion, such as robotics.
IP rated connectors keep out dust and can be used in wet areas when mated or capped. IP65 connectors can be lightly rinsed. IP67 connectors can be submerged temporarily.
Add caps to protect connectors and maintain their IP ratings when not in use.






Housing Thread | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Shielding | For Wire Gauge | For Cable OD | For Cable Industry Designation | Transmission Speed | Housing Material | Size | Pitch, mm | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
A-Code | |||||||||||||
| 8 | Shielded | 20 | 0.23"-0.31" | __ | 10 Gb/s | Nickel-Plated Brass | M12 | 1 | -10° to 185° | IP67 | C-UL Recognized Component, UL Recognized Component | 8256T73 | 000000 |
D-Code | |||||||||||||
| 4 | Shielded | 26-22 | 0.18"-0.35" | Category 5 | 100 Mbps | Chrome-Plated Zinc | M12 | 1 | -40° to 185° | IP65, IP67 | __ | 8256T1 | 00000 |
X-Code | |||||||||||||
| 8 | Shielded | 26-22 | 0.2"-0.38" | Category 5E, Category 6, Category 6A | 10 Gb/s | Nickel-Plated Zinc | M12 | 1 | -40° to 185° | IP67 | __ | 1164N23 | 00000 |








Housing Thread | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Shielding | Wire Lead Gauge (No. of Wires) | Cable Outer Insulation Material | For Cable Industry Designation | Transmission Speed | Housing Material | Size | Pitch, mm | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
3 ft. Lg. Cable Leads | |||||||||||||
A-Code | |||||||||||||
| 8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E | 10 Gb/s | Rubber | M12 | 1 | -40° to 165° | IP67 | UL Listed, C-UL Listed | 8256T51 | 000000 |
D-Code | |||||||||||||
| 4 | Shielded | 22 (4) | Polyurethane Rubber | Category 5E | 100 Mbps | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | __ | 8256T44 | 00000 |
X-Code | |||||||||||||
| 8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E, Category 6, Category 6A | 10 Gb/s | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | __ | 8256T46 | 00000 |
Y-Code | |||||||||||||
| 8 | Shielded | 26 (4); 20 (4) | Polyurethane Rubber | Category 5E | 100 Mbps | Nickel-Plated Zinc | M12 | 1 | -10° to 155° | IP65, IP67 | UL Listed, C-UL Listed | 8256T68 | 00000 |
16 ft. Lg. Cable Leads | |||||||||||||
A-Code | |||||||||||||
| 8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E | 10 Gb/s | Rubber | M12 | 1 | -40° to 165° | IP67 | UL Listed, C-UL Listed | 8256T52 | 000000 |
D-Code | |||||||||||||
| 4 | Shielded | 22 (4) | Polyurethane Rubber | Category 5E | 100 Mbps | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | __ | 8256T61 | 00000 |
X-Code | |||||||||||||
| 8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E, Category 6, Category 6A | 10 Gb/s | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | __ | 8256T62 | 00000 |
Y-Code | |||||||||||||
| 8 | Shielded | 26 (4); 20 (4) | Polyurethane Rubber | Category 5E | 100 Mbps | Nickel-Plated Zinc | M12 | 1 | -10° to 155° | IP65, IP67 | UL Listed, C-UL Listed | 8256T69 | 000000 |


Housing Thread | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Shielding | Wire Lead Gauge (No. of Wires) | Cable Outer Insulation Material | For Cable Industry Designation | Transmission Speed | Housing Material | Size | Pitch, mm | Temperature Range, °F | Environmental Rating | Each | |
3 ft. Lg. Cable Leads | ||||||||||||
D-Code | ||||||||||||
| 4 | Shielded | 22 (4) | Polyurethane Rubber | Category 5E | 100 Mbps | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | 8256T45 | 000000 |
X-Code | ||||||||||||
| 8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E, Category 6, Category 6A | 10 Gb/s | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | 8256T47 | 00000 |
16 ft. Lg. Cable Leads | ||||||||||||
D-Code | ||||||||||||
| 4 | Shielded | 22 (4) | Polyurethane Rubber | Category 5E | 100 Mbps | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | 8256T63 | 00000 |
X-Code | ||||||||||||
| 8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E, Category 6, Category 6A | 10 Gb/s | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | 8256T64 | 00000 |




Housing Thread | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Shielding | For Cable OD | For Cable Industry Designation | Transmission Speed | Housing Material | Size | Pitch, mm | Temperature Range, °F | Environmental Rating | Each | |
D-Code | |||||||||||
| 4 | Shielded | 0.2"-0.38" | Category 5E | 100 Mbps | Nickel-Plated Zinc | M12 | 1 | -40° to 185° | IP67 | 8256T66 | 000000 |
X-Code | |||||||||||
| 8 | Shielded | 0.2"-0.38" | Category 5E, Category 6, Category 6A | 10 Gb/s | Nickel-Plated Zinc | M12 | 1 | -40° to 185° | IP67 | 8256T67 | 00000 |






Housing Thread | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Shielding | Wire Lead Gauge (No. of Wires) | Cable Outer Insulation Material | For Cable Industry Designation | Transmission Speed | Housing Material | Size | Pitch, mm | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
3 ft. Lg. Cable Leads | |||||||||||||
A-Code | |||||||||||||
| 8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E | 10 Gb/s | Rubber | M12 | 1 | -40° to 165° | IP67 | UL Listed, C-UL Listed | 8256T53 | 000000 |
X-Code | |||||||||||||
| 8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E, Category 6, Category 6A | 10 Gb/s | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | __ | 8256T43 | 00000 |
5 ft. Lg. Cable Leads | |||||||||||||
D-Code | |||||||||||||
| 4 | Shielded | 24 (4) | TPE Rubber | Category 5E | 100 Mbps | Nickel-Plated Brass | M12 | 1 | -10° to 175° | IP67 | UL Recognized Component | 8256T71 | 00000 |
16 ft. Lg. Cable Leads | |||||||||||||
A-Code | |||||||||||||
| 8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E | 10 Gb/s | Rubber | M12 | 1 | -40° to 165° | IP67 | UL Listed, C-UL Listed | 8256T54 | 000000 |
D-Code | |||||||||||||
| 4 | Shielded | 24 (4) | TPE Rubber | Category 5E | 100 Mbps | Nickel-Plated Brass | M12 | 1 | -10° to 175° | IP67 | UL Recognized Component | 8256T72 | 00000 |
X-Code | |||||||||||||
| 8 | Shielded | 26 (8) | Polyurethane Rubber | Category 5E, Category 6, Category 6A | 10 Gb/s | Tin-Plated Copper | M12 | 1 | -20° to 190° | IP67 | __ | 8256T65 | 00000 |






Housing Thread | Mounting Thread | Environmental Rating | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Shielding | For Cable Industry Designation | Transmission Speed | Color | Housing Material | Size | Pitch, mm | For Panel Cutout Dia. | Size | Pitch, mm | Temperature Range, °F | M12 Connection | RJ45 Connection | Each | |
A-Code Female × RJ45 Female | |||||||||||||||
| 8 | Shielded | Category 5E | 10 Gb/s | Silver | Plastic | M12 | 1 | 0.48" | M12 | 1 | -40° to 175° | IP67 | IP67 | 8256T59 | 000000 |
D-Code Female × RJ45 Female | |||||||||||||||
| 4 | Shielded | Category 5 | 100 Mbps | Silver | Plastic | M12 | 1 | 0.66" | M16 | 1.5 | -40° to 185° | IP65, IP67 | IP20 | 8256T3 | 00000 |
X-Code Female × RJ45 Female | |||||||||||||||
| 8 | Shielded | Category 5E, Category 6, Category 6A | 10 Gb/s | __ | Zinc | M12 | 1 | 0.555" | M16 | 1.5 | -10° to 185° | IP67 | IP20 | 8256T42 | 00000 |




Housing Thread | Mounting Thread | Environmental Rating | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Shielding | For Cable Industry Designation | Transmission Speed | Color | Housing Material | Size | Pitch, mm | For Panel Cutout Dia. | Size | Pitch, mm | Temperature Range, °F | M12 Connection | RJ45 Connection | Each | |
D-Code Female × RJ45 Female | |||||||||||||||
| 4 | Shielded | Category 5 | 100 Mbps | Black | Plastic | M12 | 1 | 0.66" | M16 | 1.5 | -40° to 185° | IP65, IP67 | IP20 | 8256T2 | 000000 |
X-Code Female × RJ45 Female | |||||||||||||||
| 8 | Shielded | Category 5E, Category 6, Category 6A | 10 Gb/s | __ | Zinc | M12 | 1 | 0.555" | M16 | 1.5 | -10° to 185° | IP67 | IP20 | 8256T41 | 00000 |
Food Industry Micro M12 Screw-Together Ethernet Connectors

FDA compliant to safely touch food and threaded for a tight hold, these connectors won’t vibrate loose as they send high-speed data to sensors and other automated devices in food, beverage, and pharmaceutical plants. They stand up to brief submersion as well as high-heat washdowns and harsh cleaners common to food lines, thanks to their IP ratings, TPE insulation, and stainless steel and polypropylene housing. Their insulation also means they’re flexible and won’t break down from abrasion or UV exposure. Overall, they’re more rugged than traditional RJ45 connectors.
To reduce the risk of signal loss between equipment, these connectors block signal interference from nearby devices. Poles and keyways on their face adhere to standard coding layouts, keeping you from mis-mating connections. D coded, these connectors are often used within Ethernet/IP, Profinet, and EtherCat systems. They can also power devices as they send data, so you don’t need a separate power cord. But, your device must be Power over Ethernet (PoE) compatible.
When choosing an Ethernet connector, make sure you match or exceed your network’s category industry designation. These connectors are backward compatible—for example, a Category 6 connector will work in a Category 5 network, but it’ll only run at the Category 5 speed.
Housing Thread | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Voltage | Current, A | Wire Lead Gauge | Shielding | Transmission Speed, Mbps | Size | Pitch, mm | Temperature Range, ° F | Environmental Rating | Specifications Met | Each | |
9.5 ft. Lg. Cable Leads | ||||||||||||
Wire Leads—External Thread | ||||||||||||
D-Code—Category 5E | ||||||||||||
| 4 | 60V DC | 4 | 22 | Shielded | 100 | M12 | 1 | -40° to 220° | IP65, IP68, IP69K | UL Listed, FDA Compliant 21 CFR 177.2600 | 5658N11 | 000000 |
32.5 ft. Lg. Cable Leads | ||||||||||||
Wire Leads—External Thread | ||||||||||||
D-Code—Category 5E | ||||||||||||
| 4 | 60V DC | 4 | 22 | Shielded | 100 | M12 | 1 | -40° to 220° | IP65, IP68, IP69K | UL Listed, FDA Compliant 21 CFR 177.2600 | 5658N13 | 000000 |
M8 Ethernet Connectors
The threaded end of these M8 connectors keeps contaminants out and withstands vibration better than RJ45 ends on traditional Ethernet cords. They are often used with sensors, switches, and I/O modules. To protect against signal interference, these connectors are shielded. Connectors are Power over Ethernet (POE) enabled to carry data and power within one connector.
To view wiring diagrams, select a part number and click Product Detail.
A-coded connectors work with EtherCAT connections that have the same pole configuration.
Snap-on wire connections pierce wire insulation, eliminating the need for wire stripping. They maintain a secure hold in high-vibration applications.
Connectors with a polyurethane cable bend easily, so they are ideal for applications that require continuous flexibility such as robotics. They also resist oil.
These connectors are IP rated when mated. IP65 rated connectors protect against dust and low-pressure jets of water. IP67 rated connectors keep out dust and water from temporary submersion.

Cable | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Transmission Speed, Mbps | Face Diameter | Voltage | Current, A | Wire Lead Gauge | OD | Lead Length, ft. | Outer Insulation Material | Shielding | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
D-Coded—Category 5 | ||||||||||||||
| 4 | 100 | 0.27" | 50V AC/60V DC | 4 | 22 | 0.25" | 3 | Polyurethane Rubber | Shielded | -20° to 175° | IP67 | __ | 6115N11 | 000000 |
| 4 | 100 | 0.27" | 50V AC/60V DC | 4 | 22 | 0.25" | 6.5 | Polyurethane Rubber | Shielded | -20° to 175° | IP67 | __ | 6115N12 | 00000 |
| 4 | 100 | 0.27" | 50V AC/60V DC | 4 | 22 | 0.25" | 16 | Polyurethane Rubber | Shielded | -20° to 175° | IP67 | __ | 6115N13 | 00000 |
| 4 | 100 | 0.27" | 50V AC/60V DC | 4 | 22 | 0.25" | 32.5 | Polyurethane Rubber | Shielded | -20° to 175° | IP67 | __ | 6115N14 | 000000 |
A-Coded—Category 5E | ||||||||||||||
| 4 | 100 | 0.27" | 30V AC/30V DC | 4 | 26 | 0.19" | 1.5 | Polyurethane Rubber | Shielded | 0° to 120° | IP67 | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 6115N26 | 00000 |
| 4 | 100 | 0.27" | 30V AC/30V DC | 4 | 26 | 0.19" | 3 | Polyurethane Rubber | Shielded | 0° to 120° | IP67 | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 6115N17 | 00000 |
| 4 | 100 | 0.27" | 30V AC/30V DC | 4 | 26 | 0.19" | 6.5 | Polyurethane Rubber | Shielded | 0° to 120° | IP67 | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 6115N18 | 00000 |
| 4 | 100 | 0.27" | 30V AC/30V DC | 4 | 26 | 0.19" | 16 | Polyurethane Rubber | Shielded | 0° to 120° | IP67 | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 6115N19 | 00000 |
| 4 | 100 | 0.27" | 30V AC/30V DC | 4 | 26 | 0.19" | 32.5 | Polyurethane Rubber | Shielded | 0° to 120° | IP67 | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 6115N21 | 000000 |

| Number of Poles | Transmission Speed, Mbps | Face Diameter | Voltage | Current, A | For Wire Gauge | For Cable OD | Shielding | Temperature Range, °F | Environmental Rating | Each | |
D-Coded—Category 5 | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 100 | 0.27" | 50V AC/60V DC | 4 | 22 | 0.24"-0.26" | Shielded | -40° to 185° | IP65, IP67 | 6115N15 | 000000 |

Cable | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Number of Poles | Transmission Speed, Mbps | Face Diameter | Voltage | Current, A | Wire Lead Gauge | OD | Lead Length, ft. | Outer Insulation Material | Shielding | Temperature Range, °F | Environmental Rating | Specifications Met | Each | |
A-Coded—Category 5E | ||||||||||||||
| 4 | 100 | 0.27" | 30V AC/30V DC | 4 | 26 | 0.19" | 3 | Polyurethane Rubber | Shielded | 0° to 120° | IP67 | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 6115N22 | 000000 |
| 4 | 100 | 0.27" | 30V AC/30V DC | 4 | 26 | 0.19" | 6.5 | Polyurethane Rubber | Shielded | 0° to 120° | IP67 | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 6115N23 | 00000 |
| 4 | 100 | 0.27" | 30V AC/30V DC | 4 | 26 | 0.19" | 16 | Polyurethane Rubber | Shielded | 0° to 120° | IP67 | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 6115N24 | 00000 |
| 4 | 100 | 0.27" | 30V AC/30V DC | 4 | 26 | 0.19" | 32.5 | Polyurethane Rubber | Shielded | 0° to 120° | IP67 | UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified | 6115N25 | 000000 |

| Number of Poles | Transmission Speed, Mbps | Face Diameter | Voltage | Current, A | For Wire Gauge | For Cable OD | Shielding | Temperature Range, °F | Environmental Rating | Each | |
D-Coded—Category 5 | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 4 | 100 | 0.27" | 50V AC/60V DC | 4 | 22 | 0.24"-0.26" | Shielded | -40° to 185° | IP65, IP67 | 6115N16 | 000000 |
M29 Power Cords


Often used in automation systems such as conveyors and sorters, these cords have plug and socket ends, so they quickly connect and disconnect for maintenance and do not need to be hardwired. Because these cords carry higher currents than micro and mini cords, they can power equipment such as motors, fans, pumps, and automated machine tools. They are shielded to block out interference from nearby equipment. These cords meet UL 2237 and UL 2238, so they can be used in motor branch circuits of industrial machinery. They also meet TC-ER crush and impact requirements for exposed runs in cable carriers. IP rated, they protect against dust, washdowns, and temporary submersion.
Connect these cords to control cabinets and equipment with M29 power receptacles (sold separately).
Housing Thread | Cord | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| No. of Poles | Face Dia. | Lg., ft. | Current, A | Voltage | Size | Type | Wire Gauge | OD | Insulation Material | Industry Designation | Temp. Range, °F | Environmental Rating | Specifications Met | Each | |
Shielded Plug (External Thread) × Shielded Socket (Internal Thread) | |||||||||||||||
| 4 | 1" | 3 | 25 | 600V AC/600V DC | 1 1/8"-16 | UNS | 12 | 0.65" | PVC Plastic | TC-ER | -10° to 190° | IP67, IP68 | UL Listed, C-UL Listed, UL 2237, UL 2238 | 7429N11 | 0000000 |
| 4 | 1" | 6 1/2 | 25 | 600V AC/600V DC | 1 1/8"-16 | UNS | 12 | 0.65" | PVC Plastic | TC-ER | -10° to 190° | IP67, IP68 | UL Listed, C-UL Listed, UL 2237, UL 2238 | 7429N12 | 000000 |
| 4 | 1" | 16 | 25 | 600V AC/600V DC | 1 1/8"-16 | UNS | 12 | 0.65" | PVC Plastic | TC-ER | -10° to 190° | IP67, IP68 | UL Listed, C-UL Listed, UL 2237, UL 2238 | 7429N13 | 000000 |
| 4 | 1" | 32 1/2 | 25 | 600V AC/600V DC | 1 1/8"-16 | UNS | 12 | 0.65" | PVC Plastic | TC-ER | -10° to 190° | IP67, IP68 | UL Listed, C-UL Listed, UL 2237, UL 2238 | 7429N14 | 000000 |
| 4 | 1" | 49 | 25 | 600V AC/600V DC | 1 1/8"-16 | UNS | 12 | 0.65" | PVC Plastic | TC-ER | -10° to 190° | IP67, IP68 | UL Listed, C-UL Listed, UL 2237, UL 2238 | 7429N15 | 000000 |
Ethernet Cords with M8 Connectors

Unlike the RJ45 ends on traditional Ethernet cords, the threaded M8 ends on these cords keep contaminants out and resist coming loose from vibration. They are often used with sensors, switches, I/O modules, and computers. Braided shielding protects against signal interference. Insulated with polyurethane, these cords bend easily, so they are ideal for applications that require continuous flexibility such as robotics. They also resist oil. When mated, they are IP67 rated for protection from dust and temporary submersion.
D-coded cords are Power over Ethernet (POE) enabled to carry data and power within one cord.
| Lg., ft. | No. of Poles | Transmission Speed, Mbps | Wire Gauge | Cord OD | Shielding | Shield Type | Temp. Range, °F | Environmental Rating | Cord Insulation Material | Color | Each | |
M8 Plug × M8 Plug | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
D-Coded—Ethernet Cable Category 5 | ||||||||||||
| 3 1/4 | 4 | 100 | 22 | 0.2" | Shielded | Braid | -20° to 175° | IP67 | Polyurethane Rubber | Green | 6185N11 | 000000 |
| 6 1/2 | 4 | 100 | 22 | 0.2" | Shielded | Braid | -20° to 175° | IP67 | Polyurethane Rubber | Green | 6185N12 | 00000 |
| 16 1/4 | 4 | 100 | 22 | 0.2" | Shielded | Braid | -20° to 175° | IP67 | Polyurethane Rubber | Green | 6185N13 | 000000 |
| 32 3/4 | 4 | 100 | 22 | 0.2" | Shielded | Braid | -20° to 175° | IP67 | Polyurethane Rubber | Green | 6185N14 | 000000 |