McMaster-Carr logo
    Filter by
    Display Type
    Measurement Unit
    Temperature Resolution
    Stem Length
    Attribute Image
    For Use With
    Dial Diameter
    Maximum Cable Temperature
    Probe Material
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    Holding Force
    Response Time
    Digit Height
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    15 Products

    Minimum/Maximum Indicating Magnetic-Back Surface-Temperature Thermometers

    Image of Product. Front orientation. Thermometers. Minimum/Maximum Indicating Magnetic-Back Surface-Temperature Thermometers.
    In addition to showing current surface temperature, these thermometers have pointers to indicate the minimum and maximum temperatures since the last reading. Reset the minimum and maximum pointers with the included magnetic wand.
    Material
    Temp. Range
    Graduations
    Accuracy
    Dial
    Dia.
    Mount Type
    Holding
    Force, lbf
    Housing
    Lens
    Each
    -100° F to 160° F2° F±2%2"Magnetic Back5AluminumGlass3982K410000000
    0° F to 150° F1° F±2%2"Magnetic Back5AluminumGlass3982K42000000
    0° F to 250° F2° F±2%2"Magnetic Back5AluminumGlass3982K43000000
    0° F to 500° F5° F±2%2"Magnetic Back5AluminumGlass3982K44000000
    50° F to 750° F10° F±2%2"Magnetic Back5AluminumGlass3982K45000000
    -20° C to 120° C1° C±2%2"Magnetic Back5AluminumGlass3982K47000000
    -20° C to 250° C2° C±2%2"Magnetic Back5AluminumGlass3982K48000000
    10° C to 400° C5° C±2%2"Magnetic Back5AluminumGlass3982K51000000
     

    Remote-Reading Magnetic-Back Thermometers with Calibration Certificate

    Image of Product. Front orientation. Thermometers. Remote-Reading Magnetic-Back Thermometers with Calibration Certificate, ±1.8° F Accuracy.

    ±1.8° F Accuracy

    Externally monitor the air temperature inside freezers, refrigerators, water baths, and incubators. These thermometers come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy. The probe is insulated in a bottle filled with mercury-free fluid to prevent false readings from rapid temperature changes such as opening freezer doors.
    The display simultaneously shows the high, low, and current temperatures. These thermometers have a programmable alarm to indicate when temperature rises above or below your actuation point.
    10 ft. Long Cable—Thermometers have a probe with a 10-ft. cable that connects to a magnetic-back external display.
    Material
    Temp. Range
    Accuracy
    Temp.
    Resolution
    Cable Lg.,
    ft.
    Probe
    Dia.
    Response
    Time, sec.
    Ht.
    Wd.
    Dp.
    Housing
    Probe
    Cable
    Fluid
    Material
    Batteries
    Included
    Each
    For Use With Air
    -58° F to 158° F/-50° C to 70° C±1.8° F/±1.0° C1° F/1° C103/16"604 1/4"2 3/4"3/4"PlasticGlassPVCGlycolYes9276T12000000
     

    Remote-Reading Handheld Thermometers with Calibration Certificate

    Image of Product. Front orientation. Thermometers. Remote-Reading Handheld Thermometers with Calibration Certificate, Style B.

    Style B

    A remote probe extends your reach in hard-to-access areas. These thermometers come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy.
    Probe
    Style
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    No. of Probe
    Inputs
    Response
    Time, sec.
    Cable Lg.,
    ft.
    Lg.
    Dia.
    Batteries
    Included
    Each
    For Use With Air and Liquids
    B-58° F to 158° F/-50° C to 70° C1° F/1° C±1.8° F/±1° C110107/8"3/16"Yes9268T24000000
     

    Minimum/Maximum-Indicating Threaded Thermometers

    Image of Product. Front orientation. Thermometers. Minimum/Maximum-Indicating Threaded Thermometers.
    Image of Product. Bottom orientation. Contains Annotated. Thermometers. Minimum/Maximum-Indicating Threaded Thermometers.
    In addition to a pointer that shows the current temperature, these thermometers have a second pointer that indicates the highest or lowest temperature reached. They are not recommended for high-vibration environments.
    Stem
    Material
    Lg.
    Dia.
    Dial
    Dia.
    Pipe
    Size
    Thread
    Type
    Gender
    Max. Pressure
    @ Temp.
    Overall
    Ht.
    Housing
    Stem
    Lens
    Accuracy
    Choose a Temperature, ° F
    Each
    Back Connection
    2 1/2"1/4"3"1/2
    NPT
    Male400 psi @ 72° F4 1/8"Stainless SteelStainless SteelGlass±1%-40 to 160, 0 to 140, 0 to 200, 50 to 300, 150 to 7503988K20000000
    4"1/4"3"1/2
    NPT
    Male400 psi @ 72° F5 3/8"Stainless SteelStainless SteelGlass±1%-40 to 160, 0 to 140, 0 to 200, 50 to 300, 150 to 7503988K4000000
    6"1/4"3"1/2
    NPT
    Male400 psi @ 72° F7 3/8"Stainless SteelStainless SteelGlass±1%-40 to 160, 0 to 140, 0 to 200, 50 to 300, 150 to 7503988K6000000
    9"1/4"3"1/2
    NPT
    Male400 psi @ 72° F10 3/8"Stainless SteelStainless SteelGlass±1%-40 to 160, 0 to 140, 0 to 200, 50 to 300, 150 to 7503988K8000000
    12"1/4"3"1/2
    NPT
    Male400 psi @ 72° F13 3/8"Stainless SteelStainless SteelGlass±1%-40 to 160, 0 to 140, 0 to 200, 50 to 300, 150 to 7503988K9000000
     
    back to top