Surface-Mount Motor Voltage Monitors

Protect electric motors from phase loss, phase reversal, overvoltage, undervoltage, and voltage imbalance. Also known as voltage-monitoring relays, these monitors cut power to a motor when a fault occurs.
For technical drawings and 3-D models, click on a part number.
Trip Time, sec. | Switching | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage Range | No. of Terminals | Control Power, W | Voltage Imbalance Adjustment | Automatic Reset | Delayed Automatic Reset | Current, A | Voltage | Ht. | Wd. | Specifications Met | Each | |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||
Three Phase | ||||||||||||
190-480V AC | 7 | 6 | 2%-8% | 1-30 | 1-500 | 10 | 240V AC | 3.5" | 2.08" | UL Listed | 0000000 | 0000000 |
475-600V AC | 7 | 6 | 2%-8% | 1-30 | 1-500 | 10 | 240V AC | 3.5" | 2.08" | UL Listed | 0000000 | 000000 |
DIN-Rail Mount Motor Voltage Monitors

Mount these monitors to 35 mm DIN rail. They protect electric motors from phase loss, phase reversal, overvoltage, undervoltage, and voltage imbalance. Also known as voltage-monitoring relays, they cut power to a motor when a fault occurs.
For technical drawings and 3-D models, click on a part number.
Switching | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage Range | No. of Terminals | Control Power, W | Voltage Imbalance Adjustment | Trip Time, sec. | Reset Type | Current, A | Voltage | Horsepower @ Voltage | Ht. | Wd. | Specifications Met | Each | |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
Three Phase | |||||||||||||
200-480V AC | 9 | 5 | 2%-10% | 1-30 | Automatic | 10 | 240V AC | 1/3 hp @ 240 V AC | 3" | 2" | UL Listed, C-UL Listed | 0000000 | 0000000 |
Socket-Mount Motor Voltage Monitors

Plug these monitors into relay sockets for fast installation and replacement. They protect electric motors from phase loss, phase reversal, overvoltage, undervoltage, and voltage imbalance. Also known as voltage-monitoring relays, they cut power to a motor when a fault occurs.
Relay sockets (sold separately) mount to 35 mm DIN rail or flat surfaces.
Voltage Monitors | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching | Relay Sockets | |||||||||||||
Input Voltage Range | No. of Terminals | Control Power, W | Voltage Imbalance Adjustment | Trip Time, sec. | Reset Type | Current, A | Voltage | Ht. | Wd. | Specifications Met | Each | Each | ||
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||
Three Phase | ||||||||||||||
200-480V AC | 8 | 5 | 2%-10% | 0.25-30 | Automatic | 10 | 240V AC | 2.4" | 1.8" | UL Recognized Component, CSA Certified | 0000000 | 0000000 | 0000000 | 00000 |
Safety Relays
Receive signals from safety monitoring relays or controllers to switch devices off and on because of a system failure. Also known as force-guided or mechanically linked contacts, the interlocking opposing contacts on these relays cannot be open or closed at the same time. To keep your system from receiving false switching signals, the interlocking opposing contact must remain open even if a contact welds closed.
IP20 rated, they have recessed terminals that prevent fingers and other objects from touching live circuits. These relays have been tested to safety standards that can help you achieve your system's PL (performance level) and SIL (safety integrity level). Choose a relay with a PL and SIL rating to meet the needs of your system. Higher ratings indicate greater safety protection. As your system becomes more complex, you generally require a higher safety protection level. Mount them to 35mm DIN rail (also known as DIN 3 Rail).
Relays that meet SIL3 are tested for applications with a probability of failure of 0.01% to 0.1% and are used for preventing fires, explosions, or toxic releases. Relays that meet CAT 4 withstand circuit surges in electrical applications up to 600V.
When a failure is detected, relays with self-monitoring circuitry signal the controller to remove power and prevent restarting until the issue is resolved.
Relays with nondetachable contacts have auxiliary contacts that won’t separate from the relay if there is shock or vibration. Relays with mirror auxiliary contacts have contacts that are normally closed and cannot be open at the same time as a normally open main contact.
For technical drawings and 3-D models, click on a part number.

Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | Auxiliary Contact Switch Starting Position | Ht. | Wd. | Dp. | Features | Each | |
With Spring-Clamp Terminals—DIN-Rail Mount | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | |||||||||||
18 | 24V AC, 24V DC | 5 | 5 A @ 120 V AC | 230V AC | 1 On (Normally Closed) | 3.9" | 0.9" | 4.8" | Interlocked Opposing Contacts, Recessed Terminals, Self-Monitoring Circuitry, Nondetachable Auxiliary Contacts, Mirror Auxiliary Contacts, LED Indicator | 00000000 | 0000000 |

hp @ Switching Voltage | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Control Current, mA | Switching Current @ Voltage | Max. Switching Voltage | Single Phase | Three Phase | Auxiliary Contact Switch Starting Position | Ht. | Wd. | Dp. | Features | Each | |
With Screw Terminals—DIN-Rail and Surface Mount | |||||||||||||
3 Circuits Controlled with 3 Off (Normally Open)—3PST-NO | |||||||||||||
18 | 120V AC | 2 | 7 A @ 400 V AC | 600V AC | 1/4 hp @ 120 V AC 1 hp @ 240 V AC | 2 hp @ 240 V AC 3 hp @ 480 V AC 5 hp @ 600 V AC | 2 Off (Normally Open) or 3 On (Normally Closed) | 2.7" | 1.8" | 4.6" | Interlocked Opposing Contacts, Recessed Terminals, Self-Monitoring Circuitry, Nondetachable Auxiliary Contacts, Mirror Auxiliary Contacts, Inspection Window | 0000000 | 0000000 |
18 | 120V AC | 2 | 9 A @ 400 V AC | 600V AC | 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3 hp @ 240 V AC 5 hp @ 480 V AC 7 1/2 hp @ 600 V AC | 2 Off (Normally Open) or 3 On (Normally Closed) | 2.7" | 1.8" | 4.6" | Interlocked Opposing Contacts, Recessed Terminals, Self-Monitoring Circuitry, Nondetachable Auxiliary Contacts, Mirror Auxiliary Contacts, Inspection Window | 0000000 | 000000 |
18 | 120V AC | 2 | 12 A @ 400 V AC | 600V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3 hp @ 240 V AC 10 hp @ 480 V AC 10 hp @ 600 V AC | 2 Off (Normally Open) or 3 On (Normally Closed) | 2.7" | 1.8" | 4.6" | Interlocked Opposing Contacts, Recessed Terminals, Self-Monitoring Circuitry, Nondetachable Auxiliary Contacts, Mirror Auxiliary Contacts, Inspection Window | 0000000 | 000000 |
18 | 120V AC | 5 | 18 A @ 400 V AC | 600V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 2 Off (Normally Open) or 3 On (Normally Closed) | 3.4" | 1.8" | 5.5" | Interlocked Opposing Contacts, Recessed Terminals, Self-Monitoring Circuitry, Nondetachable Auxiliary Contacts, Mirror Auxiliary Contacts, Inspection Window | 0000000 | 000000 |
18 | 120V AC | 5 | 25 A @ 400 V AC | 600V AC | 2 hp @ 120 V AC 5 hp @ 240 V AC | 10 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 2 Off (Normally Open) or 3 On (Normally Closed) | 3.4" | 1.8" | 5.5" | Interlocked Opposing Contacts, Recessed Terminals, Self-Monitoring Circuitry, Nondetachable Auxiliary Contacts, Mirror Auxiliary Contacts, Inspection Window | 0000000 | 000000 |
18 | 24V DC | 3 | 18 A @ 400 V AC | 600V AC | 2 hp @ 120 V AC 3 hp @ 240 V AC | 5 hp @ 240 V AC 10 hp @ 480 V AC 15 hp @ 600 V AC | 2 Off (Normally Open) or 3 On (Normally Closed) | 3.4" | 1.8" | 5.5" | Interlocked Opposing Contacts, Recessed Terminals, Self-Monitoring Circuitry, Nondetachable Auxiliary Contacts, Mirror Auxiliary Contacts, Inspection Window | 0000000 | 000000 |
18 | 24V DC | 3 | 25 A @ 400 V AC | 600V AC | 2 hp @ 120 V AC 5 hp @ 240 V AC | 10 hp @ 240 V AC 15 hp @ 480 V AC 20 hp @ 600 V AC | 2 Off (Normally Open) or 3 On (Normally Closed) | 3.4" | 1.8" | 5.5" | Interlocked Opposing Contacts, Recessed Terminals, Self-Monitoring Circuitry, Nondetachable Auxiliary Contacts, Mirror Auxiliary Contacts, Inspection Window | 0000000 | 000000 |
18 | 24V DC | 12 | 7 A @ 400 V AC | 600V AC | 1/4 hp @ 120 V AC 1 hp @ 240 V AC | 2 hp @ 240 V AC 3 hp @ 480 V AC 5 hp @ 600 V AC | 2 Off (Normally Open) or 3 On (Normally Closed) | 2.7" | 1.8" | 4.6" | Interlocked Opposing Contacts, Recessed Terminals, Self-Monitoring Circuitry, Nondetachable Auxiliary Contacts, Mirror Auxiliary Contacts, Inspection Window | 0000000 | 000000 |
18 | 24V DC | 18 | 9 A @ 400 V AC | 600V AC | 1/2 hp @ 120 V AC 1 1/2 hp @ 240 V AC | 3 hp @ 240 V AC 5 hp @ 480 V AC 7 1/2 hp @ 600 V AC | 2 Off (Normally Open) or 3 On (Normally Closed) | 2.7" | 1.8" | 4.6" | Interlocked Opposing Contacts, Recessed Terminals, Self-Monitoring Circuitry, Nondetachable Auxiliary Contacts, Mirror Auxiliary Contacts, Inspection Window | 0000000 | 000000 |
18 | 24V DC | 18 | 12 A @ 400 V AC | 600V AC | 1 hp @ 120 V AC 2 hp @ 240 V AC | 3 hp @ 240 V AC 10 hp @ 480 V AC 10 hp @ 600 V AC | 2 Off (Normally Open) or 3 On (Normally Closed) | 2.7" | 1.8" | 4.6" | Interlocked Opposing Contacts, Recessed Terminals, Self-Monitoring Circuitry, Nondetachable Auxiliary Contacts, Mirror Auxiliary Contacts, Inspection Window | 0000000 | 000000 |
Safety Relays with Diagnostic Capabilities
Control and diagnose issues with safety-critical circuits. These relays have a microprocessor that monitors safety components, such as emergency stops and light curtains, and sends a signal to stop the operation if a failure is detected and restart when the issue is resolved. They also help with diagnostic tasks because of their feedback circuit, which allows basic relays to communicate their status back to the safety relay. These relays have a duplicate set of input and output signals, so they’ll still stop the controlled device if one of the inputs fails.
IP20 rated, they have recessed terminals which prevent fingers and other objects from touching live circuits. These relays have been tested to multiple safety standards and can help achieve PL, SIL, or CAT system ratings. They also meet ISO and IEC standards for machine safety.
Mount them to 35 mm DIN rail (also known as DIN 3 Rail) for fast installation.
Auxiliary contact blocks (sold separately) allow you to control more components, such as signaling devices or basic relays.
For technical drawings and 3-D models, click on a part number.

Number of Terminals | Input Voltage | Switching Current @ Voltage | Max. Switching Voltage | Ht. | Wd. | Dp. | For Use With | Max. System Safety Rating | Features | Each | |
3 Circuits Controlled | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
3 Safety Outputs with 3 Off (Normally Open) | |||||||||||
6 | 24V DC | 6 A @ 240 V AC 6 A @ 24 V DC | 240V AC | 3.7" | 0.9" | 4.8" | Light Curtains | PLe, SIL3 | Auxiliary PNP Output, Self-Monitoring Circuitry | 0000000 | 0000000 |


Number of Terminals | Input Voltage | Switching Current @ Voltage | Max. Switching Voltage | Ht. | Wd. | Dp. | Features | Each | |
5 Safety Outputs | |||||||||
---|---|---|---|---|---|---|---|---|---|
16 | 24V AC, 24V DC | 2.5 A @ 24 V DC 3 A @ 240 V AC | 250V AC, 250V DC | 3.9" | 0.9" | 4.5" | __ | 0000000 | 0000000 |
4 Delayed Safety Outputs | |||||||||
16 | 24V DC | 3 A @ 240 V AC 3 A @ 24 V DC | 250V AC, 250V DC | 3.9" | 0.9" | 4.5" | Time Delay | 0000000 | 000000 |
Smart Multifunction Monitoring Relays

Remotely control these relays through an app on your smartphone—they simultaneously monitor phase, voltage, and frequency. The downloadable app lets you change the tripping range, modify settings, and save programs to apply to multiple relays. Tap your smartphone or tablet to the relays to connect to them. They use NFC (near field communication), so you don’t need to manually pair them like Bluetooth devices.
You’ll often see these relays used to protect motors, generators, and other three-phase circuits from burning out or overheating. They'll switch the circuit off if they detect voltage or frequencies outside of the set range or phase loss, imbalance, or reversal. You can see that they're wired correctly and when they're actuated based on the LED indicators. Rated IP20, they have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on a 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
For technical drawings and 3-D models, click on a part number.
Trip Voltage | Trip Frequency | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Min. | Max. | Input Frequency, Hz | Min., Hz | Max., Hz | Trip Time, sec. | Reset Type | Switching Current @ Voltage | Max. Switching Voltage | Ht. | Wd. | Dp. | Operating System Compatibility | Each | |
2 Circuits Controlled with 2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||||||
With Screw Terminals | ||||||||||||||||
12 | 208V AC, 240V AC, 300V AC, 480V AC | 208V AC | 480V AC | 50, 60 | 45 | 66 | 0.1-60 | Automatic | 8 A @ 240 V AC | 250V AC | 3.5" | 0.9" | 3.9" | Android 7.0 or Later, iOS 14.5 or Later | 0000000 | 0000000 |
Voltage-Monitoring Relays
Safeguard your equipment against overheating, wear, and malfunction from a spike or dip in voltage. These relays continuously monitor your AC or DC power supply and trip when the voltage is outside a set range. Rated IP20, these relays have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on a 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
Relays have knobs right on the front where you can set your trip voltage. You can see that they're wired correctly and when they're actuated based on the LED indicators. If you want to mount these relays to a surface instead of DIN rail, they have mounting holes.
Relays with IO link can be programmed, monitored and reset remotely by connecting them to a programmable logic controller (PLC), human-machine interface (HMI), or computer. If you want to program them locally, they have a keypad.
Relays with spring-clamp terminals connect and disconnect to wire without screws. Because there’s no screw, these connections are less likely to loosen over time, even in high-vibration environments.
For technical drawings and 3-D models, click on a part number.

Number of Terminals | Input Voltage | Trip Voltage Setting | Trip Time, sec. | Reset Type | Switching Current @ Voltage | Max. Switching Voltage | Adjustment Style | Ht. | Wd. | Dp. | Features | Each | |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
With Spring-Clamp Terminals | |||||||||||||
9 | 24V AC, 24V DC | 1-10V AC/DC 3-30V AC/DC 15-150V AC/DC | 0.1-30 | Automatic, Manual | 5 A @ 240 V AC 5 A @ 30 V DC | 250V AC 48V DC | Knob | 3.5" | 0.7" | 3.5" | LED Indicator | 00000000 | 0000000 |
9 | 24V AC, 24V DC | 20-200V AC/DC 30-300V AC/DC 60-600V AC/DC | 0.1-30 | Automatic, Manual | 5 A @ 240 V AC 5 A @ 30 V DC | 250V AC 48V DC | Knob | 3.5" | 0.7" | 3.5" | LED Indicator | 00000000 | 000000 |
9 | 120V AC, 240V AC | 1-10V AC/DC 3-30V AC/DC 15-150V AC/DC | 0.1-30 | Automatic, Manual | 5 A @ 240 V AC 5 A @ 30 V DC | 250V AC 48V DC | Knob | 3.5" | 0.7" | 3.5" | LED Indicator | 00000000 | 000000 |
9 | 120V AC, 240V AC | 20-200V AC/DC 30-300V AC/DC 60-600V AC/DC | 0.1-30 | Automatic, Manual | 5 A @ 240 V AC 5 A @ 30 V DC | 250V AC 48V DC | Knob | 3.5" | 0.7" | 3.5" | LED Indicator | 00000000 | 000000 |

Trip Voltage | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Min. | Max. | Trip Time, sec. | Reset Type | Switching Current @ Voltage | Max. Switching Voltage | Adjustment Style | Ht. | Wd. | Dp. | Display Type | Features | Each | |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||||
With Screw Terminals | |||||||||||||||
9 | 24V DC | 10V AC/DC | 600V AC/DC | 0-999 | Automatic | 3 A @ 240 V AC 1 A @ 24 V DC | 400V AC 250V DC | Keypad, External Controller | 3.6" | 0.9" | 3.6" | LCD | Remote Reset | 00000000 | 0000000 |
With Spring-Clamp Terminals | |||||||||||||||
9 | 24V DC | 10V AC/DC | 600V AC/DC | 0-999 | Automatic | 3 A @ 240 V AC 1 A @ 24 V DC | 400V AC 250V DC | Keypad, External Controller | 3.8" | 0.9" | 3.6" | LCD | Remote Reset | 00000000 | 000000 |
Multifunction Monitoring Relays

Monitor phase, voltage, and frequency at the same time to protect motors, generators, and other three-phase circuits from burning out or overheating. They'll switch the circuit off if they detect voltage or frequencies outside of the set range or phase loss, imbalance, or reversal. Rated IP20, they have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on a 35 mm DIN (also known as DIN 3 rail) for fast installation.
These relays use IO Link, so they can be programmed, monitored, and reset remotely by connecting them to a programmable logic controller (PLC), human-machine interface (HMI), or computer. If you want to program them locally, they have a keypad.
Relays with spring-clamp terminals connect and disconnect to wire without screws. Because there’s no screw, these connections are less likely to loosen over time, even in high-vibration environments.
For technical drawings and 3-D models, click on a part number.
Trip Voltage | Trip Frequency | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Terminals | Input Voltage | Min. | Max. | Input Frequency, Hz | Min., Hz | Max., Hz | Trip Time, sec. | Reset Type | Switching Current @ Voltage | Max. Switching Voltage | Adjustment Style | Ht. | Wd. | Dp. | Each | |
1 Circuit Controlled with 1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||||
With Screw Terminals and IO Link | ||||||||||||||||
12 | 24V DC | 90V AC | 760V AC | 50, 60 | 15 | 70 | 0.1-30 | Automatic | 3 A @ 240 V AC 1 A @ 24 V DC | 400V AC 250V DC | Keypad, External Controller | 3.9" | 0.9" | 3.6" | 0000000 | 0000000 |
With Spring-Clamp Terminals and IO Link | ||||||||||||||||
12 | 24V DC | 90V AC | 760V AC | 50, 60 | 15 | 70 | 0.1-30 | Automatic | 3 A @ 240 V AC 1 A @ 24 V DC | 400V AC 250V DC | Keypad, External Controller | 3.9" | 0.9" | 3.6" | 0000000 | 000000 |
Frequency-Monitoring Relays


Prevent changes in frequency from damaging sensitive equipment. Often used with motors, fluorescent lighting, and controllers, these relays cut power to your device if the frequency falls outside the set range. Switches on the front of these relays let you set your trip frequency and time. You can see that they're wired correctly and when they're actuated based on the LED indicators. Rated IP20, these relays have recessed terminals that keep fingers and other objects from touching live circuits.
DIN-rail mount relays snap onto 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
Relay-socket mount relays plug into a socket (sold separately), which is required for installation.
For technical drawings and 3-D models, click on a part number.
Relays | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Trip Frequency Setting | Relay Sockets | |||||||||||||||
No. of Terminals | Input Voltage | 50 Hz Input | 60 Hz Input | Trip Time, sec. | Reset Type | Switching Current @ Voltage | Max. Switching Voltage | Adjustment Style | Ht. | Wd. | Dp. | Features | Each | Each | ||
1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | ||||||||||||||||
DIN-Rail Mount | ||||||||||||||||
9 | 24V AC, 48V AC, 120V AC, 240V AC | 40-60 Hz 48-52 Hz | 50-70 Hz 58-62 Hz | 0.1-30 | Automatic, Manual | 8 A @ 240 V AC 5 A @ 24 V DC | 250V AC 24V DC | DIP Switch | 3.1" | 0.9" | 3.9" | LED Indicator | 0000000 | 0000000 | 000000 | 00 |
Relay-Socket Mount | ||||||||||||||||
1 | 24V AC, 48V AC, 120V AC, 240V AC | 40-60 Hz 48-52 Hz | 50-70 Hz 58-62 Hz | 0.1-30 | Automatic, Manual | 8 A @ 240 V AC 5 A @ 24 V DC | 250V AC 24V DC | DIP Switch | 3.1" | 1.4" | 3.7" | LED Indicator | 0000000 | 000000 | 0000000 | 000000 |
Current-Monitoring Relays



Protect electrical equipment from overcurrent and undercurrent damage—these relays continuously monitor current flow. When current is outside a set range, they trip and cut power to prevent overheating, fire hazards, and stalling. Rated IP20, these relays have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on a 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
Relays with spring-clamp terminals connect and disconnect to wire without screws. Because there’s no screw, these connections are less likely to loosen over time, even in high-vibration environments.
Relays with IO link can be programmed, monitored, and reset remotely by connecting them to a programmable logic controller (PLC), human-machine interface (HMI), or computer. If you want to program them locally, they have a keypad.
Relays with knob adjustments have knobs right on the front where you can set your trip current. You can see that they're wired correctly and when they're actuated based on the LED indicators.
For technical drawings and 3-D models, click on a part number.
Trip Current | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Terminals | Input Voltage | Trip Current Setting | Min. | Max. | Trip Time, sec. | Reset Type | Switching Current @ Voltage | Max. Switching Voltage | Adjustment Style | Ht. | Wd. | Dp. | Display Type | Each | |
Screw Terminals | |||||||||||||||
1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||||
9 | 24V AC, 24V DC | 0.1-1A, 0.5-5A, 0.8-8A | __ | __ | 0.1-30 | Automatic, Manual | 5 A @ 240 V AC 5 A @ 30 V DC | 250V AC 30V DC | Knob | 3.5" | 0.9" | 3.9" | __ | 0000000 | 0000000 |
9 | 120V AC, 240V AC | 0.1-1A, 0.5-5A, 0.8-8A | __ | __ | 0.1-30 | Automatic, Manual | 5 A @ 240 V AC 5 A @ 30 V DC | 250V AC 30V DC | Knob | 3.5" | 0.9" | 3.9" | __ | 0000000 | 000000 |
Screw Terminals with IO Link | |||||||||||||||
1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||||
9 | 24V DC | __ | 0.05A | 10A | 0-999 | Automatic | 1 A @ 24 V DC 3 A @ 240 V AC | 400V AC 250V DC | External Controller, Keypad | 3.6" | 0.9" | 3.4" | LCD | 0000000 | 000000 |
Spring-Clamp Terminals with IO Link | |||||||||||||||
1 Off (Normally Open) or 1 On (Normally Closed)—SPDT | |||||||||||||||
9 | 24V DC | __ | 0.05A | 10A | 0-999 | Automatic | 1 A @ 24 V DC 3 A @ 240 V AC | 400V AC 250V DC | External Controller, Keypad | 3.8" | 0.9" | 3.4" | LCD | 0000000 | 000000 |
Ground-Fault Monitoring Relays
Detect and mitigate ground faults to prevent harm to equipment, circuits, and people. These relays monitor the differential between incoming and outgoing current, also known as residual current. When the balance is off, they trip and cut power to the circuit. These relays are highly sensitive, so you can trust them to de-energize faulty circuits before a minor issue becomes a major one. Rated IP20, they have recessed terminals that keep fingers and other objects from touching live circuits. Mount them on 35 mm DIN rail (also known as DIN 3 rail) for fast installation.
These relays require a current-indicating ring (sold separately) to operate. Choose a ring that is large enough for your lines to pass through. Feed the lines of the circuit through the center of the ring and connect the indicating ring output to the relay.
Relays with spring-clamp terminals connect and disconnect to wire without screws. Because they don’t have screws, there’s less of a risk that they will loosen over time, even when they’re under vibration.
Relays with IO link can be programmed, monitored, and reset remotely by connecting them to a programmable logic controller (PLC), human-machine interface (HMI), or computer. If you want to program them locally, they have a keypad.
Relays with knob adjustments have knobs right on the front where you can set your trip current.
Relays with an LED indicator show the status of your relay, so you know it is wired correctly and when it is actuated.
For technical drawings and 3-D models, click on a part number.




Trip Current | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
No. of Terminals | Input Voltage | Trip Current Setting | Min. | Max. | Trip Time, sec. | Switching Current @ Voltage | Max. Switching Voltage | Adjustment Style | Ht. | Wd. | Dp. | Features | Each | |
Screw Terminals | ||||||||||||||
2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||||
12 | 24V AC, 48V AC, 120V AC, 240V AC | 0.03A | __ | __ | 0 | 5 A @ 240 V AC 5 A @ 24 V DC | 250V AC 24V DC | __ | 3.2" | 1.4" | 2.6" | LED Indicator | 00000000 | 0000000 |
12 | 24V AC, 48V AC, 120V AC, 240V AC | 0.3A | __ | __ | 0 | 5 A @ 240 V AC 5 A @ 24 V DC | 250V AC 24V DC | __ | 3.2" | 1.4" | 2.6" | LED Indicator | 00000000 | 000000 |
12 | 24V AC, 48V AC, 120V AC, 240V AC | __ | 0.3A | 30A | 0-5 | 5 A @ 240 V AC 5 A @ 24 V DC | 250V AC 24V DC | Knob | 3.2" | 1.4" | 2.8" | LED Indicator | 00000000 | 000000 |
12 | 24V AC, 48V AC, 120V AC, 240V AC | __ | 0.03A | 5A | 0-5 | 5 A @ 240 V AC 5 A @ 24 V DC | 250V AC 24V DC | Knob | 3.2" | 1.4" | 2.8" | LED Indicator | 00000000 | 000000 |
Screw Terminals with IO Link | ||||||||||||||
2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||||
12 | 24V DC | __ | 0.03A | 40A | 0-999 | 3 A @ 240 V AC 1 A @ 24 V DC | 400V AC 250V DC | Keypad, External Controller | 4" | 0.9" | 3.6" | Remote Reset | 00000000 | 000000 |
Spring-Clamp Terminals with IO Link | ||||||||||||||
2 Off (Normally Open) or 2 On (Normally Closed)—DPDT | ||||||||||||||
12 | 24V DC | __ | 0.03A | 40A | 0-999 | 3 A @ 240 V AC 1 A @ 24 V DC | 400V AC 250V DC | Keypad, External Controller | 4.1" | 0.9" | 3.6" | Remote Reset | 00000000 | 000000 |
Current Relays

Prevent AC current overload in equipment such as motors and heaters.
These relays sense current flowing through wires routed through the opening. If the current exceeds a set trip point, the relay trips and starts the adjustable delay timer. After the timer's cycle, the relay cuts power to the equipment to protect against overload. Once current drops below the trip point, the relay allows power to flow again to the equipment.
To determine the current trip range for more than one wire, divide the listed trip range by the number of wires passed through the opening.
Current Trip Range for One Wire, A | Switch Industry Designation | Resistive Load | Delay Time Range | For Max. Wire Dia. | Ht. | Wd. | Dp. | Input AC Voltage | Wire Connection | Specifications Met | Mount Type | Fasteners Included | Mounting Hole Dia. | No. of Mounting Holes | Each | |
Measures AC Current | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
0.1-1 | SPDT | 10 A @ 240 V AC | 0.5-6 sec. | 0.5" | 2.13" | 3.5" | 2.5" | 120 | 1/4" Quick-Disconnect Terminals | UL Recognized Component | Screw On | No | 0.19" | 2 | 00000000 | 0000000 |
1-10 | SPDT | 10 A @ 240 V AC | 0.5-6 sec. | 0.5" | 2.13" | 3.5" | 2.5" | 120 | 1/4" Quick-Disconnect Terminals | UL Recognized Component, C-UL Recognized Component | Screw On | No | 0.19" | 2 | 00000000 | 000000 |
3-30 | SPDT | 10 A @ 240 V AC | 0.5-6 sec. | 0.5" | 2.13" | 3.5" | 2.5" | 120 | 1/4" Quick-Disconnect Terminals | UL Recognized Component, C-UL Recognized Component | Screw On | No | 0.19" | 2 | 00000000 | 000000 |
6-60 | SPDT | 10 A @ 240 V AC | 0.5-6 sec. | 0.5" | 2.13" | 3.5" | 2.5" | 120 | 1/4" Quick-Disconnect Terminals | UL Recognized Component, C-UL Recognized Component | Screw On | No | 0.19" | 2 | 00000000 | 000000 |
10-100 | SPDT | 10 A @ 240 V AC | 0.5-6 sec. | 0.5" | 2.13" | 3.5" | 2.5" | 120 | 1/4" Quick-Disconnect Terminals | UL Recognized Component, C-UL Recognized Component | Screw On | No | 0.19" | 2 | 00000000 | 000000 |