    50 Products

    Enclosure Motor Switches

    Image of Specification. Front orientation. Contains Annotated. Enclosure Motor Switches.
    Designed to mount on an electrical enclosure, these switches control motors, lighting, and electric heat circuits. Your enclosure door will only open when the switch is turned to the off position. This ensures equipment is safely off before you open the electrical enclosure. For an extra layer of safety, use a padlock (not included) on the actuator lever to lock switches in the off position. These switches do not provide overload protection.
    Cut the shaft to fit your enclosure. Mount to a DIN rail inside an enclosure; mounting depth is the distance from the panel door to the DIN rail.
    Switching
    No. of Circuits
    Controlled
    Electrical Phase (hp)
    Switch Starting
    Position
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Housing
    Material
    Ht.
    Wd.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Wire
    Connection
    Environment
    Enclosure
    Rating
    Certification
    Each
    Maintained
     
    Lever Actuator
    3Single (2 hp @ 240V AC)
    Single (5 hp @ 480V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    3 Off
    3PST-NO
    25600Plastic2.4"2.4"357 7/8" to 14 5/8"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N110000000
    3Single (2 hp @ 240V AC)
    Single (5 hp @ 480V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    3 Off
    3PST-NO
    32600Plastic2.4"2.4"357 7/8" to 14 5/8"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N12000000
    3Single (3 hp @ 240V AC)
    Single (5 hp @ 480V AC)
    Three (5 hp @ 240V AC)
    Three (10 hp @ 480V AC)
    3 Off
    3PST-NO
    40600Plastic2.4"2.4"357 7/8" to 14 5/8"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N13000000
    3Three (10 hp @ 240V AC)
    Three (20 hp @ 480V AC)
    3 Off
    3PST-NO
    63600Plastic2.4"2.4"358 1/16" to 15 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N14000000
    3Three (15 hp @ 240V AC)
    Three (30 hp @ 480V AC)
    3 Off
    3PST-NO
    80600Plastic2.4"2.4"358 1/16" to 15 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N15000000
    3Three (25 hp @ 240V AC)
    Three (50 hp @ 480V AC)
    3 Off
    3PST-NO
    125600Plastic3.5"3.5"359 1/16" to 16 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N16000000
    3Three (30 hp @ 240V AC)
    Three (50 hp @ 480V AC)
    3 Off
    3PST-NO
    175600Plastic3.5"3.5"359 1/16" to 16 9/16"Screw TerminalDusty, Washdown, WetIP65
    UL Listed, C-UL Listed, CSA Certified
    7802N17000000
     

    Enclosed Compact Disconnect Switches

    Small yet mighty, these switches are about as tall and wide as an index card yet durable enough to mount directly to a wall. Don’t be fooled by their size—these switches can handle electrical loads comparable to a standard sized switch.
    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Enclosed Compact Disconnect Switches.
    Plastic Housing—Their plastic housing protects the switch and resists denting, chipping, and cracking.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP65 Enclosure Rating—Rated IP65, the housing also seals out water even in frequently washed down areas.
    Switching Current @ Voltage
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout
    12 amp @ 600V AC, 16 amp @ 24V DC3PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K210000000
    16 amp @ 600V AC, 20 amp @ 24V DC3PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K22000000
    20 amp @ 600V AC, 25 amp @ 24V DC3PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K23000000
    25 amp @ 600V AC, 32 amp @ 24V DC3PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K24000000
    50 amp @ 600V AC, 50 amp @ 24V DC3PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K25000000
    63 amp @ 600V AC, 80 amp @ 24V DC3PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    UL 50865915K26000000
     
    4 Circuits Controlled with Lockout
    12 amp @ 600V AC, 16 amp @ 24V DC4PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K34000000
    16 amp @ 600V AC, 20 amp @ 24V DC4PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K35000000
    20 amp @ 600V AC, 25 amp @ 24V DC4PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K36000000
    25 amp @ 600V AC, 32 amp @ 24V DC4PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4 3/4"3 13/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K37000000
    50 amp @ 600V AC, 50 amp @ 24V DC4PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K38000000
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    5 5/16"6 11/16"5/16"IP65
    UL Recognized Component, CSA Certified
    65915K39000000
     

    Panel-Mount Compact Disconnect Switches

    Install these switches in a panel cutout. Small enough to fit in tight spaces, they handle comparable electrical loads to standard sized switches. They cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Front orientation. Disconnect Switches. Panel-Mount Compact Disconnect Switches.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP65 Enclosure Rating—They’re rated IP65 for protection from washdowns.
    Switching Current @ Voltage
    Switch
    Designation
    Electrical Phase (hp)
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Gray Plastic Housing with Black Actuator
     
    3 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC3PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K101000000
    16 amp @ 600V AC, 20 amp @ 24V DC3PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10200000
    20 amp @ 600V AC, 25 amp @ 24V DC3PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10300000
    25 amp @ 600V AC, 32 amp @ 24V DC3PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K104000000
    50 amp @ 600V AC, 50 amp @ 24V DC3PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K105000000
    63 amp @ 600V AC, 80 amp @ 24V DC3PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K106000000
     
    4 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC4PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10700000
    16 amp @ 600V AC, 20 amp @ 24V DC4PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10800000
    20 amp @ 600V AC, 25 amp @ 24V DC4PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K10900000
    25 amp @ 600V AC, 32 amp @ 24V DC4PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K111000000
    50 amp @ 600V AC, 50 amp @ 24V DC4PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K112000000
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K113000000
     
    Yellow Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC3PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K1100000
    16 amp @ 600V AC, 20 amp @ 24V DC3PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K1200000
    20 amp @ 600V AC, 25 amp @ 24V DC3PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K1300000
    25 amp @ 600V AC, 32 amp @ 24V DC3PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K14000000
    50 amp @ 600V AC, 50 amp @ 24V DC3PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K15000000
    63 amp @ 600V AC, 80 amp @ 24V DC3PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K16000000
     
    4 Circuits Controlled with Lockout—For 3/8" Dia. Panel Cutouts
    12 amp @ 600V AC, 16 amp @ 24V DC4PST
    Single (1/2 hp @ 120V AC)
    Three (1 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K4100000
    16 amp @ 600V AC, 20 amp @ 24V DC4PST
    Single (1 hp @ 120V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K4200000
    20 amp @ 600V AC, 25 amp @ 24V DC4PST
    Single (1 1/2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3 1/4"2 1/2"1 13/16"5/16"IP65
    UL Recognized Component
    UL 50865915K4300000
    25 amp @ 600V AC, 32 amp @ 24V DC4PST
    Single (2 hp @ 120V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    4"3 1/8"2"5/16"IP65
    UL Recognized Component
    UL 50865915K44000000
    50 amp @ 600V AC, 50 amp @ 24V DC4PST
    Single (3 hp @ 120V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (15 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K45000000
    63 amp @ 600V AC, 80 amp @ 24V DC4PST
    Single (5 hp @ 120V AC)
    Three (10 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    4"3 1/8"3 3/16"5/16"IP65
    UL Recognized Component
    UL 50865915K46000000
     

    Washdown Programmable Three-Phase AC Motor Speed Controls

    Image of Product. Front orientation. Motor Speed Controls. Washdown Programmable Three-Phase AC Motor Speed Controls.
    Rated NEMA 4, these controls are protected from washdowns. Set them to automatically adjust motor speed. Wire a potentiometer (not included) for remote manual control.
    NEMA 12 Enclosure Rating—Controls rated NEMA 12 also protect against splashes of oil and coolant when used indoors only.
    Output
    Power,
    hp
    Input Voltage,
    V AC
    Current,
    amp
    Voltage,
    V AC
    Freq.,
    Hz
    Input Signal
    Ht.
    Wd.
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Features
    Environment
    Enclosure Rating
    Certification
    Each
    Single-Phase Input
     
    Reversing Motor
    1200 to 2404.2200 to 2400 to 1200 to 10V DC, 4 to 20 mA8"6.5"No0.25" (4)Corrosive, Oily, Outdoor, Washdown, Wet, DustyNEMA 4, NEMA 12, IP65
    UL Listed
    C-UL Listed
    CE Marked
    7786K720000000
     
    Single-Phase Input/Three-Phase Input
     
    Reversing Motor
    2200 to 2407200 to 2400 to 5000 to 10V DC, 4 to 20 mA8"6.28"Yes0.2" (4)Thermal Overload ProtectionOutdoor, Washdown, Wet, DustyNEMA 4, IP65
    UL Listed
    C-UL Listed
    CE Marked
    7786K39000000
     
    Three-Phase Input
     
    Reversing Motor
    2400 to 4803.4400 to 4800 to 5000 to 10V DC, 4 to 20 mA8"6.28"Yes0.2" (4)Thermal Overload ProtectionOutdoor, Washdown, Wet, DustyNEMA 4, IP65
    UL Listed
    C-UL Listed
    CE Marked
    7786K3600000000
    3400 to 4804.8400 to 4800 to 5000 to 10V DC, 4 to 20 mA8"6.28"Yes0.2" (4)Thermal Overload ProtectionCorrosive, Outdoor, Washdown, Wet, DustyNEMA 4, IP65
    UL Listed
    C-UL Listed
    CE Marked
    7786K3800000000
     

    Enclosed Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Enclosed Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Enclosed Disconnect Switches.

    Power Pole

    Neutral Pole

    Cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. These switches are housed in a protective enclosure that resists denting, chipping, and cracking. Mount them to the wall when you run out of space in an electrical panel.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Two-Circuit Switch with Lockout. Front orientation. Disconnect Switches. Enclosed Disconnect Switches, Plastic Housing, 2 Circuits Controlled, Lockout.

    Two-Circuit

    Switch with

    Lockout

    Lockout—Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
    Photovoltaic—Photovoltaic switches can be used with photovoltaic cells which convert sunlight into electricity.
    Switching
    Current,
    amp
    Voltage,
    V DC
    Switch
    Designation
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Each
    Yellow Plastic Housing with Red Actuator
     
    2 Circuits Controlled with Lockout/Photovoltaic
    50800DPST
    12 5/8"8 11/16"5/16"Screw TerminalIP65
    NEMA 3R
    UL Listed, C-UL Listed, CE Marked
    6759K740000000
    63650DPST
    12 5/8"8 11/16"5/16"Screw TerminalIP65
    NEMA 3R
    UL Listed, C-UL Listed, CE Marked
    6759K71000000
     
    Labels