McMaster-Carr logo
    Filter by
    Electrical Phase
    Switching Voltage
    Industrial Info Snippet
    Actuator Style
    Number of Circuits Controlled
    Switch Action
    Number of Mounting Holes
    Switch Designation
    Industrial Info Compare
    Housing Color
    Specifications Met
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    UL File Number
    Maximum Padlock Shackle Diameter
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Electrical Connection
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    18 Products

    Washdown Enclosed Motor Switches

    Image of Product. Switch with Stainless Steel Housing and Lockout. Front orientation. Motor Switches. Washdown Enclosed Motor Switches, 304 Stainless Steel Housing with Lockout.
    Image of Product. Switch with Polybutylene Housing and Lockout. Front orientation. Motor Switches. Washdown Enclosed Motor Switches, Polybutylene Housing with Lockout.
    Image of Product. Switch with Polybutylene Housing, Lockout, and Power Indicator. Front orientation. Motor Switches. Washdown Enclosed Motor Switches, Polybutylene Housing with Lockout, Power Indicator.

    Switch with

    Stainless Steel

    Housing and

    Lockout

    Switch with

    Polybutylene

    Housing and

    Lockout

    Switch with

    Polybutylene

    Housing,

    Lockout, and

    Power Indicator

    Install these switches in areas with oil, coolant, corrosive chemicals, and regular washdowns. They're rated IP69K and NEMA 4X and 12 or 12K. Since they’re already protected inside a housing, you can mount them to a wall if there’s no space left in your electrical panel. You need to grip and twist the lever to actuate, so they won’t accidentally turn on or off if something bumps into them. To lock them in the off position, attach a padlock (not included) to the lever. Use these switches to turn motors on and off, or with other circuits such as lighting and electric heat circuits. They do not provide overload protection.
    Polybutylene Housing—Switches with a Polybutylene housing can be turned into a handheld control for moving around your workstation by attaching a cord and cord grip. The housing won’t swell in moist environments.
    Power Indicator—Switches with a power indicator use LED lights to show the status of power flowing into the switch and power flowing from the switch to your motor. This can help you check for issues, such as a welded contact or phase loss, without having to open the housing.
    Switching
    No. of Circuits
    Controlled
    Electrical Phase (hp)
    Switch Starting
    Position
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Ht.
    Wd.
    Wire
    Connection
    Enclosure Rating
    Certification
    Specs.
    Met
    Flammability
    Rating
    Each
    Maintained
     
    304 Stainless Steel Housing with Lockout
    3Three (7 1/2 hp @ 240V AC)3 Off
    3PST-NO
    306007.1"4.9"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K1030000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    6060010.3"7.3"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K104000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    10060010.3"7.3"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K10500000000
     
    Polybutylene Housing with Lockout
    3Three (7 1/2 hp @ 240V AC)3 Off
    3PST-NO
    306008.17"5.29"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K71000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    6060011"7.28"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K201000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    10060011"7.28"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K202000000
     
    Polybutylene Housing with Lockout, Power Indicator
    3Three (7 1/2 hp @ 240V AC)3 Off
    3PST-NO
    306008.2"5.3"Screw TerminalNEMA 4X, IP69K, NEMA 12
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K106000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    6060010.9"7.3"Screw TerminalNEMA 4X, IP69K, NEMA 12
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K107000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    10060010.9"7.3"Screw TerminalNEMA 4X, IP69K, NEMA 12
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K108000000
     

    Harsh Environment Panel-Mount Disconnect Switches

    These switches cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Style B. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.
    Image of Product. Style A. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.
    Image of Product. Style C. Front orientation. Disconnect Switches. Harsh Environment Panel-Mount Disconnect Switches.

    Style B

    Style A

    Style C

    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    IP69K Enclosure Rating—Rated IP69K, these switches withstand high-pressure, high-temperature washdowns.
    Switching
    Style
    Current,
    amp
    Voltage,
    V AC
    Switch
    Designation
    Electrical Phase (hp)
    Dia.
    Ht.
    Wd.
    Dp. Behind
    Panel
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure
    Rating
    Certification
    Specs.
    Met
    Each
    Yellow Stainless Steel Housing with Red Actuator
     
    2 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    A20300DPST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 15/16"2 15/16"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K1120000000
     
    3 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    B406003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K511000000
    B606003PST
    Single (3 hp @ 120V AC)
    Single (7 1/2 hp @ 240V AC)
    Three (15 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K521000000
     
    4 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    A203004PST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 15/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K115000000
     
    Gray Stainless Steel Housing with Gray Actuator
     
    2 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    C20300DPST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 1/8"2 3/4"2 15/16"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K113000000
     
    3 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    B406003PST
    Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (7 1/2 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K512000000
    B606003PST
    Single (3 hp @ 120V AC)
    Single (7 1/2 hp @ 240V AC)
    Three (15 hp @ 240V AC)
    4 5/16"4 5/16"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K522000000
     
    4 Circuits Controlled with Lockout—For 7/8" Dia. Panel Cutouts
    C203004PST
    Single (3/4 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 240V AC)
    3 1/8"2 3/4"3 3/8"5/16"Screw TerminalIP69K
    UL Listed, C-UL Listed, CE Marked
    UL 5086759K116000000
     
    Labels
    back to top