McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    99 Products

    Washdown Enclosed Motor Switches

    Image of Product. Switch with Stainless Steel Housing and Lockout. Front orientation. Motor Switches. Washdown Enclosed Motor Switches, 304 Stainless Steel Housing with Lockout.
    Image of Product. Switch with Polybutylene Housing and Lockout. Front orientation. Motor Switches. Washdown Enclosed Motor Switches, Polybutylene Housing with Lockout.
    Image of Product. Switch with Polybutylene Housing, Lockout, and Power Indicator. Front orientation. Motor Switches. Washdown Enclosed Motor Switches, Polybutylene Housing with Lockout, Power Indicator.

    Switch with

    Stainless Steel

    Housing and

    Lockout

    Switch with

    Polybutylene

    Housing and

    Lockout

    Switch with

    Polybutylene

    Housing,

    Lockout, and

    Power Indicator

    Install these switches in areas with oil, coolant, corrosive chemicals, and regular washdowns. They're rated IP69K and NEMA 4X and 12 or 12K. Since they’re already protected inside a housing, you can mount them to a wall if there’s no space left in your electrical panel. You need to grip and twist the lever to actuate, so they won’t accidentally turn on or off if something bumps into them. To lock them in the off position, attach a padlock (not included) to the lever. Use these switches to turn motors on and off, or with other circuits such as lighting and electric heat circuits. They do not provide overload protection.
    Polybutylene Housing—Switches with a Polybutylene housing can be turned into a handheld control for moving around your workstation by attaching a cord and cord grip. The housing won’t swell in moist environments.
    Power Indicator—Switches with a power indicator use LED lights to show the status of power flowing into the switch and power flowing from the switch to your motor. This can help you check for issues, such as a welded contact or phase loss, without having to open the housing.
    Switching
    No. of Circuits
    Controlled
    Electrical Phase (hp)
    Switch Starting
    Position
    Switch
    Designation
    Current,
    amp
    Voltage,
    V AC
    Ht.
    Wd.
    Wire
    Connection
    Enclosure Rating
    Certification
    Specs.
    Met
    Flammability
    Rating
    Each
    Maintained
     
    304 Stainless Steel Housing with Lockout
    3Three (7 1/2 hp @ 240V AC)3 Off
    3PST-NO
    306007.1"4.9"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K1030000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    6060010.3"7.3"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K104000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    10060010.3"7.3"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K10500000000
     
    Polybutylene Housing with Lockout
    3Three (7 1/2 hp @ 240V AC)3 Off
    3PST-NO
    306008.17"5.29"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K71000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    6060011"7.28"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K201000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    10060011"7.28"Screw TerminalNEMA 4X, IP69K, NEMA 12K
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K202000000
     
    Polybutylene Housing with Lockout, Power Indicator
    3Three (7 1/2 hp @ 240V AC)3 Off
    3PST-NO
    306008.2"5.3"Screw TerminalNEMA 4X, IP69K, NEMA 12
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K106000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    6060010.9"7.3"Screw TerminalNEMA 4X, IP69K, NEMA 12
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K107000000
    3Three (30 hp @ 240V AC)3 Off
    3PST-NO
    10060010.9"7.3"Screw TerminalNEMA 4X, IP69K, NEMA 12
    UL Listed, C-UL Listed
    UL 746CUL 94 5VA
    7657K108000000
     

    Enclosed Heavy Duty Build-Your-Own Manual Motor Starters

    Image of Product. Thermal Overload Protectors. Front orientation. Motor Starters. Enclosed Heavy Duty Build-Your-Own Manual Motor Starters.
    Image of Product. Switch with NEMA 12 Enclosure Rating. Front orientation. Motor Starters. Enclosed Heavy Duty Build-Your-Own Manual Motor Starters, NEMA 12 Enclosure Rating.

    Thermal

    Overload

    Protectors

    Switch with NEMA

    12 Enclosure

    Rating

    Combine a switch with a thermal overload element to build a starter that can handle high-current-rated motors. All are housed in a durable steel enclosure. They’re also known as NEMA starters.
    Thermal overload elements shut motors off if current exceeds the full-load current rating. Three elements are required. To Order: Please specify the full-load current rating of your motor. If the full-load current rating is not shown on the motor’s faceplate, estimate the current rating (given the motor’s power and voltage).
    NEMA 12 Enclosure Rating—NEMA 12 rated switches are protected from oil/coolant dripping.
    Switches
    Thermal
    Overload Elements
    NEMA Contact
    Size
    Electrical Phase
    Housing
    Material
    Ht.
    Wd.
    Dp.
    Wire
    Connection
    Environment
    Certification
    Each
    Each
    NEMA 12 Enclosure Rating
    M-0Three (2 hp @ 115V AC)
    Three (3 hp @ 230V AC)
    Three (5 hp @ 460V AC)
    Painted Steel9.4"5.5"5"Screw TerminalDusty, Oily, WetUL Listed, CSA Certified
    7595K640000000007595K2000000
    M-1Three (3 hp @ 115V AC)
    Three (7 1/2 hp @ 230V AC)
    Three (10 hp @ 460V AC)
    Painted Steel9.4"5.5"5"Screw TerminalDusty, Oily, WetUL Listed, CSA Certified
    7595K33000000007595K200000
     

    Enclosed Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Enclosed Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Enclosed Disconnect Switches.

    Power Pole

    Neutral Pole

    Cut power and keep it isolated to prevent equipment from starting up during inspection and maintenance. These switches are housed in a protective enclosure that resists denting, chipping, and cracking. Mount them to the wall when you run out of space in an electrical panel.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three phase system.
    Maintained SwitchAbout Maintained Switch
    Image of Product. Two-Circuit Switch with Lockout. Front orientation. Disconnect Switches. Enclosed Disconnect Switches, Plastic Housing, 2 Circuits Controlled, Lockout.

    Two-Circuit

    Switch with

    Lockout

    Lockout—Switches with lockout secure in the off position with a padlock with a maximum shackle diameter of 5/16” (not included).
    Photovoltaic—Photovoltaic switches can be used with photovoltaic cells which convert sunlight into electricity.
    Switching
    Current,
    amp
    Voltage,
    V DC
    Switch
    Designation
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    Wire
    Connection
    Enclosure Rating
    Certification
    Each
    Yellow Plastic Housing with Red Actuator
     
    2 Circuits Controlled with Lockout/Photovoltaic
    32800DPST
    11"7 1/2"5/16"Screw TerminalIP66
    IP67
    NEMA 3S
    NEMA 6P
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    6759K730000000
     
    Labels

    Manual Override Enclosure Disconnect Switches

    Image of Product. Power Pole. Front orientation. Disconnect Switches. Manual Override Enclosure Disconnect Switches.
    Image of Product. Neutral Pole. Front orientation. Disconnect Switches. Manual Override Enclosure Disconnect Switches.
    Image of Product. Front orientation. Contains Annotated. Disconnect Switches. Manual Override Enclosure Disconnect Switches.

    Power Pole

    Neutral Pole

    Keep power running while you access your enclosure. Unlike standard enclosure disconnect switches, which shut off power as you open your enclosure, these have an override function. Engaging the override allows you to take voltage reading, troubleshoot an error code, or fine tune the speed of your line. Cut the shaft to fit your enclosure.
    Use additional power poles to control more than three circuits. Add neutral poles to open and close the neutral leg of a three-phase system.
    Lockout—All switches have a lockout so you can secure them in the off position with a padlock (not included).
    Safety Interlock—When the override is off, these work like a standard disconnect switch—a safety interlock prevents your enclosure from opening when power is on. The interlock also prevents the switch from turning on when the door is already open.
    Switching
    Current,
    amp
    Voltage,
    V AC
    Electrical Phase (hp)
    Ht.
    Wd.
    For Max. Padlock
    Shackle Dia.
    For DIN
    Rail Ht., mm
    Mounting Dp.
    Enclosure Rating
    Certification
    Each
    Black Plastic Housing with Black Actuator
     
    3 Circuits Controlled with Lockout and Safety Interlock—For 1 1/2" Dia. Panel Cutouts
    25600Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N170000000
    32600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N18000000
    50600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N19000000
    63600Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (5 hp @ 120V AC)
    Three (10 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N21000000
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N22000000
    100600Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (10 hp @ 120V AC)
    Three (25 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N23000000
     
    Black Plastic Housing with Red Actuator
     
    3 Circuits Controlled with Lockout and Safety Interlock—For 1 1/2" Dia. Panel Cutouts
    25600Single (3/4 hp @ 120V AC)
    Single (1 1/2 hp @ 240V AC)
    Three (1 1/2 hp @ 120V AC)
    Three (3 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N11000000
    32600Single (1 hp @ 120V AC)
    Single (2 hp @ 240V AC)
    Three (2 hp @ 120V AC)
    Three (5 hp @ 240V AC)
    3"4 1/16"5/16"354 7/8" to 15 3/4"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N12000000
    50600Single (1 1/2 hp @ 120V AC)
    Single (3 hp @ 240V AC)
    Three (3 hp @ 120V AC)
    Three (7 1/2 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N13000000
    63600Single (3 hp @ 120V AC)
    Single (5 hp @ 240V AC)
    Three (5 hp @ 120V AC)
    Three (10 hp @ 240V AC)
    3"4 1/16"5/16"355 5/16" to 16 1/8"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N14000000
    80600Single (3 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (7 1/2 hp @ 120V AC)
    Three (20 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N15000000
    100600Single (5 hp @ 120V AC)
    Single (10 hp @ 240V AC)
    Three (10 hp @ 120V AC)
    Three (25 hp @ 240V AC)
    3"4 1/16"5/16"355 11/16" to 16 1/2"IP66
    NEMA 4X
    NEMA 12
    UL Listed, C-UL Listed, CE Marked
    7994N16000000
     
    Accessories and Replacements for Disconnect Switches

    Washdown Programmable Three-Phase AC Motor Speed Controls

    Image of Product. Front orientation. Motor Speed Controls. Washdown Programmable Three-Phase AC Motor Speed Controls.
    Rated NEMA 4, these controls are protected from washdowns. Set them to automatically adjust motor speed. Wire a potentiometer (not included) for remote manual control.
    NEMA 12 Enclosure Rating—Controls rated NEMA 12 also protect against splashes of oil and coolant when used indoors only.
    Output
    Power,
    hp
    Input Voltage,
    V AC
    Current,
    amp
    Voltage,
    V AC
    Freq.,
    Hz
    Input Signal
    Ht.
    Wd.
    Mounting Fasteners
    Included
    Mounting Hole
    Dia. (No. of)
    Environment
    Enclosure Rating
    Certification
    Each
    Single-Phase Input
     
    Reversing Motor
    1200 to 2404.2200 to 2400 to 1200 to 10V DC, 4 to 20 mA8"6.5"No0.25" (4)Corrosive, Oily, Outdoor, Washdown, Wet, DustyNEMA 4, NEMA 12, IP65
    UL Listed
    C-UL Listed
    CE Marked
    7786K720000000
     
    back to top