    67 Products
    About Electric Motors
    industrial info icon

    Select a new motor using the information on the nameplate, including voltage, size, and enclosure type.

    Base-Mount AC Motors

    Image of Product. Motor with Totally Enclosed Enclosure. Front orientation. Electric Motors. Base-Mount AC Motors.
    Image of Product. Motor with Open Enclosure. Front orientation. Electric Motors. Base-Mount AC Motors.

    Motor with Totally

    Enclosed Enclosure

    Motor with Open Enclosure

    Image of Attribute. Front orientation. Contains Annotated. Base-Mount AC Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. Base-Mount AC Motors.
    To get equipment moving, bolt the base of these motors to any flat surface and connect the shaft to your load. They’re rated for continuous duty, so they’re often used with equipment that requires constant power, like fans, pumps, and conveyors.
    Motors with a NEMA frame size have an oversized shaft and high-quality bearings to stand up to heavy and side loads better than even our domestic motors. Densely packed windings and thin laminations ensure the motor stays cool and runs efficiently.
    Motors with an IEC frame size meet international standards for electrical products. Their compact body fits in tight spaces.
    Inverter Rated—When pairing with a variable frequency drive (AC motor speed control), choose a three-phase motor that’s inverter rated.
    Open Dripproof (ODP) Motor Enclosure—Open dripproof (ODP) enclosures have vents that let air flow over the motor, which keeps it cool and helps it run efficiently. Use them in clean, dry environments—the enclosure blocks drips and debris that fall from above, but dust and moisture can pass through the vents.
    Automatic—Motors with automatic overload protection turn off in overload conditions to prevent damage. Once they cool down, they start again automatically.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure
    Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Overload Protection
    Type
    Class
    Max. Temp.,
    ° F
    Each
    115V AC/230V AC, Single Phase
     
    NEMA 56
    1/41,7402.8 amp/1.4 ampNoOpen Dripproof (ODP)11 1/8"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N1050000000
    1/31,7403.7 amp/1.9 ampNoOpen Dripproof (ODP)11 3/4"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N33000000
    1/21,7405.1 amp/2.5 ampNoOpen Dripproof (ODP)12 3/8"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N32000000
    1/23,5104.9 amp/2.5 ampNoOpen Dripproof (ODP)11 3/4"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N103000000
    3/43,5106.8 amp/3.4 ampNoOpen Dripproof (ODP)12 3/8"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N36000000
     
    NEMA 56H
    3/41,7506.5 amp/3.3 ampNoOpen Dripproof (ODP)13"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N35000000
    1 1/23,50012.2 amp/6.1 ampNoOpen Dripproof (ODP)13 3/4"8 1/2"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N58000000
     
    NEMA 56/NEMA 56H
    11,7508.8 amp/4.4 ampNoOpen Dripproof (ODP)13 3/4"8 1/2"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N29000000
    21,74016.1 amp/8.0 ampNoOpen Dripproof (ODP)15 3/4"8 1/2"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N52000000
     
    NEMA 143T/NEMA 145T
    1 1/21,74011.9 amp/5.9 ampNoOpen Dripproof (ODP)15 1/4"8 1/2"8 1/4"7/8"2 1/4"3 1/2"KeyedWeldedAutomaticF3117014N17000000
     
    230V AC/460V AC, Three Phase
     
    NEMA 56
    1/31,7351.1 amp/0.5 ampYesOpen Dripproof (ODP)8 7/8"9"6 3/8"5/8"1 7/8"3 1/2"KeyedWeldedF3117014N102000000
    1/21,7351.7 amp/0.8 ampYesOpen Dripproof (ODP)10 3/8"9"6 3/8"5/8"1 7/8"3 1/2"KeyedWeldedF3117014N39000000
    1/23,4451.5 amp/0.7 ampYesOpen Dripproof (ODP)8 7/8"9"6 3/8"5/8"1 7/8"3 1/2"KeyedWeldedF3117014N101000000
    3/41,7302.4 amp/1.2 ampYesOpen Dripproof (ODP)10 3/8"9"6 3/8"5/8"1 7/8"3 1/2"KeyedWeldedF3117014N41000000
    11,7502.9 amp/1.5 ampYesOpen Dripproof (ODP)11"9"6 3/8"5/8"1 7/8"3 1/2"KeyedWeldedF3117014N37000000
    13,4702.7 amp/1.4 ampYesOpen Dripproof (ODP)11"9"6 3/8"5/8"1 7/8"3 1/2"KeyedWeldedF3117014N38000000
     
    NEMA 143T
    11,7502.9 amp/1.4 ampYesOpen Dripproof (ODP)11 1/4"9 1/2"6 3/4"7/8"2 1/4"3 1/2"KeyedWeldedF3117014N11000000
     
    NEMA 143T/NEMA 145T
    1 1/21,7504.0 amp/2.0 ampYesOpen Dripproof (ODP)12 1/4"9 1/2"6 3/4"7/8"2 1/4"3 1/2"KeyedWeldedF3117014N16000000
    21,7405.4 amp/2.7 ampYesOpen Dripproof (ODP)12 1/4"9 1/2"6 3/4"7/8"2 1/4"3 1/2"KeyedWeldedF3117014N15000000
    33,5057.6 amp/3.8 ampYesOpen Dripproof (ODP)12 1/4"9 1/2"6 3/4"7/8"2 1/4"3 1/2"KeyedWeldedF3117014N18000000
     
    NEMA 182T
    31,7558.6 amp/4.3 ampYesOpen Dripproof (ODP)14 3/8"11 1/4"10 3/8"1 1/8"2 3/4"4 1/2"KeyedWeldedF3117014N23000000
    51,74012.4 amp/6.1 ampYesOpen Dripproof (ODP)13 3/4"12 1/8"10 1/2"1 1/8"2 3/4"4 1/2"KeyedWeldedF3117014N104000000
    53,46511.8 amp/5.9 ampYesOpen Dripproof (ODP)12 3/4"12 1/8"10 1/2"1 1/8"2 3/4"4 1/2"KeyedWeldedF3117014N76000000
     
    NEMA 184T
    7 1/23,46517.3 amp/8.6 ampYesOpen Dripproof (ODP)13 3/4"12 1/8"10 1/2"1 1/8"2 3/4"4 1/2"KeyedWeldedF3117014N77000000
     
    NEMA 182T, NEMA 184T
    51,75013.6 amp/6.8 ampYesOpen Dripproof (ODP)14 3/8"11 1/4"10 3/8"1 1/8"2 3/4"4 1/2"KeyedWeldedF3117014N25000000
     
    NEMA 213T
    7 1/21,75017.9 amp/9.0 ampYesOpen Dripproof (ODP)15 3/4"14 1/4"12 3/8"1 3/8"3 3/8"5 1/4"KeyedWeldedF3117014N78000000
    103,51023.6 amp/11.8 ampYesOpen Dripproof (ODP)15 3/4"14 1/4"12 3/8"1 3/8"3 3/8"5 1/4"KeyedWeldedF3117014N79000000
     
    NEMA 215T
    101,75023.5 amp/11.7 ampYesOpen Dripproof (ODP)17 1/4"14 1/4"12 3/8"1 3/8"3 3/8"5 1/4"KeyedWeldedF3117014N8100000000
     
    NEMA 254T
    151,77035.7 amp/17.9 ampYesOpen Dripproof (ODP)20 1/2"16 5/8"14 3/4"1 5/8"4"6 1/4"KeyedWeldedF3117014N8200000000
     
    NEMA 256T
    201,77046.6 amp/24.0 ampYesOpen Dripproof (ODP)22 1/4"16 5/8"14 3/4"1 5/8"4"6 1/4"KeyedWeldedF3117014N8400000000
     
    NEMA 284T
    151,17536.9 amp/18.5 ampYesOpen Dripproof (ODP)22 7/8"19 3/8"16 1/4"1 7/8"4 5/8"7"KeyedWeldedF3117014N8300000000
    251,76557.5 amp/28.7 ampYesOpen Dripproof (ODP)22 7/8"19 3/8"16 1/4"1 7/8"4 5/8"7"KeyedWeldedF3117014N8600000000
     
    NEMA 286T
    201,17548.5 amp/24.3 ampYesOpen Dripproof (ODP)24 3/8"19 3/8"16 1/4"1 7/8"4 5/8"7"KeyedWeldedF3117014N8500000000
     
    NEMA 324T
    251,18060.6 amp/30.3 ampYesOpen Dripproof (ODP)26 1/2"21 1/2"18 3/8"2 1/8"5 1/4"8"KeyedWeldedF3117014N8700000000
     

    US-Made Base-Mount AC Motors

    Image of Product. Motor with Open Enclosure. Front orientation. Electric Motors. US-Made Base-Mount AC Motors.
    Image of Product. Motor with Totally Enclosed Enclosure. Front orientation. Electric Motors. US-Made Base-Mount AC Motors.

    Motor with Open Enclosure

    Motor with Totally

    Enclosed Enclosure

    Image of Attribute. Front orientation. Contains Annotated. US-Made Base-Mount AC Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. US-Made Base-Mount AC Motors.
    Wound, wired, and assembled in the U.S. These base-mount motors are manufactured for durability and include high-quality bearings, so they hold up to occasional overload conditions and spikes in torque. Rated for continuous duty, they’re often used with equipment that requires constant power, such as fans, pumps, and conveyors. Bolt the base of these motors to any flat surface and connect the shaft to your load.
    Enclosures that are open have vents that let air flow over the motor, which keeps it cool and helps it run efficiently. Use them in clean, dry environments—the enclosure blocks drips and debris that fall from above, but dust and moisture can pass through the vents.
    Enclosures that are totally enclosed don’t have vents, so they can be used in wet and dirty environments. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Inverter Rated—When pairing with a variable frequency drive (AC motor speed control), choose a three-phase motor that’s inverter rated.
    Open Dripproof (ODP) Motor Enclosure—Open dripproof (ODP) enclosures only have vents.
    Vibration-Damping Base—Motors with a vibration-damping base have rubber rings between the base and enclosure to minimize vibration.
    Automatic—Automatic overload protection starts the motor automatically after it cools.
    Manual—Manual overload protection must be reset manually to start the motor after it cools.
    Overload Protection Type—Motors with overload protection turn off in overload conditions to prevent motor damage.
    Drip Covers—Drip covers are recommended when your motor will be mounted with the shaft facing down. They attach to the back side of the motor to prevent moisture from pooling on top.
    Motors
    Drip Covers
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load Current
    Inverter
    Rated
    Motor Enclosure
    Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base Type
    Overload Protection
    Type
    Class
    Max. Temp.,
    ° F
    Each
    Each
    115V AC/208V AC/230V AC, Single Phase
     
    NEMA 145T
    1 1/21,72521.0 amp/9.6 amp/10.5 ampNoOpen Dripproof (ODP)14 1/4"10 1/4"9"7/8"2 1/4"3 1/2"KeyedWeldedManualB2665990K1090000000005990K4030000000
     
    115V AC/230V AC, Single Phase
     
    NEMA 48
    1/41,7252.6 amp/1.3 ampNoOpen Dripproof (ODP)10"8"8 1/4"1/2"1 1/2"3"D-ProfileWeldedF3115990K1310000005990K401000000
    1/31,7403.4 amp/1.7 ampNoOpen Dripproof (ODP)9 3/4"9"8 1/8"1/2"1 1/2"3"D-ProfileWeldedF3115990K1510000005990K401000000
    1/21,7254.7 amp/2.4 ampNoOpen Dripproof (ODP)10 3/4"8"8 1/4"1/2"1 1/2"3"D-ProfileWeldedB2665990K1320000005990K401000000
    1/23,4504.9 amp/2.5 ampNoOpen Dripproof (ODP)10"8"8 1/4"1/2"1 1/2"3"D-ProfileWeldedF3115990K1330000005990K401000000
     
    NEMA 56
    1/31,7256.0 amp/3.0 ampNoOpen Dripproof (ODP)11"7"8"5/8"1 7/8"3 1/2"KeyedVibration DampingAutomaticB2665990K1220000005990K401000000
    1/31,7403.4 amp/1.7 ampNoOpen Dripproof (ODP)10 1/8"8"8 5/8"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1520000005990K401000000
    1/21,7254.7 amp/2.4 ampNoOpen Dripproof (ODP)11"8"8 3/4"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1340000005990K401000000
    1/21,7258.4 amp/4.2 ampNoOpen Dripproof (ODP)11 3/4"7"8"5/8"1 7/8"3 1/2"KeyedVibration DampingAutomaticB2665990K170000005990K401000000
    3/41,72510.0 amp/5.0 ampNoOpen Dripproof (ODP)12 1/2"7"8"5/8"1 7/8"3 1/2"KeyedVibration DampingAutomaticB2665990K210000005990K401000000
    3/41,7506.5 amp/3.3 ampNoOpen Dripproof (ODP)12 1/4"9"9"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1360000005990K403000000
    3/43,4506.3 amp/3.3 ampNoOpen Dripproof (ODP)11"8"8 3/4"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1370000005990K401000000
    11,7508.4 amp/4.2 ampNoOpen Dripproof (ODP)12 1/4"9"9"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1380000005990K403000000
    13,4807.8 amp/3.9 ampNoOpen Dripproof (ODP)12 1/4"9"9"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1390000005990K403000000
     
    NEMA 56H
    1 1/21,72512.4 amp/6.2 ampNoOpen Dripproof (ODP)14"9 3/4"9"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K153000000005990K403000000
    1 1/23,48011.8 amp/5.9 ampNoOpen Dripproof (ODP)12 3/4"9"9"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1420000005990K403000000
     
    NEMA 56/NEMA 56H
    11,72513.0 amp/6.5 ampNoOpen Dripproof (ODP)11 1/2"7"9"5/8"1 7/8"3 1/2"KeyedVibration DampingAutomaticB2665990K310000005990K403000000
    23,47015.6 amp/7.8 ampNoOpen Dripproof (ODP)14"9"9"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1410000005990K403000000
     
    208V AC/230V AC/460V AC, Three Phase
     
    NEMA 56
    1/21,7252.1 amp/1.6 amp/0.8 ampNoOpen Dripproof (ODP)11 3/4"8 1/2"6 1/2"5/8"1 7/8"3 1/2"KeyedWeldedF3116136K1110000005990K401000000
    3/41,7302.1 amp/2.0 amp/1.0 ampYesOpen Dripproof (ODP)11 1/4"9"7"5/8"1 7/8"3 1/2"KeyedWeldedF3116136K1120000005990K403000000
    11,7503.0 amp/2.9 amp/1.5 ampYesOpen Dripproof (ODP)11 1/4"9"7"5/8"1 7/8"3 1/2"KeyedWeldedF3116136K1130000005990K401000000
    13,4504.2 amp/3.2 amp/1.6 ampNoOpen Dripproof (ODP)11"8 1/2"6 1/2"5/8"1 7/8"3 1/2"KeyedWeldedF3116136K1140000005990K401000000
     

    US-Made Face-Mount AC Motors

    Image of Product. Motor with Totally Enclosed Enclosure. Front orientation. Electric Motors. US-Made Face-Mount AC Motors .
    Image of Product. Motor with Open Enclosure. Front orientation. Electric Motors. US-Made Face-Mount AC Motors .

    Motor with Totally Enclosed

    Enclosure

    Motor with Open Enclosure

    Image of Attribute. Front orientation. Contains Annotated. US-Made Face-Mount AC Motors .
    Image of Attribute. Side1 orientation. Contains Annotated. US-Made Face-Mount AC Motors .
    Wound, wired, and assembled in the U.S. These motors are manufactured for durability and include high-quality bearings, so they hold up to occasional overload conditions and spikes in torque. They bolt directly to gearboxes, pumps, and other machinery. These motors are more compact than base-mount motors and the direct, rigid connection to your equipment keeps them aligned. Rated for continuous duty, they’re often used with equipment that requires constant power, like fans, pumps, and conveyors.
    Enclosures that are open have vents that let air flow over the motor, which keeps it cool and helps it run efficiently. Use them in clean, dry environments—the enclosure blocks drips and debris that fall from above, but dust and moisture can pass through the vents.
    Enclosures that are totally enclosed don’t have vents, so they can be used in wet and dirty environments. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Open Dripproof (ODP) Motor Enclosure—Open dripproof (ODP) enclosures have vents.
    Drip Covers—Drip covers are recommended when your motor will be mounted with the shaft facing down. They attach to the back side of the motor to prevent moisture from pooling on top.
    Motors
    Drip Covers
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load Current
    Inverter
    Rated
    Motor Enclosure
    Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Each
    Each
    115V AC/230V AC, Single Phase
     
    NEMA 56C
    1/41,7252.6 amp/1.3 ampNoOpen Dripproof (ODP)12"8 1/4"8 1/4"5/8"1 7/8"3"KeyedB2666135K11100000005990K4010000000
    1/31,7403.4 amp/1.7 ampNoOpen Dripproof (ODP)12"8 1/4"8 1/4"5/8"1 7/8"3"KeyedB2666135K1120000005990K401000000
    1/21,7254.7 amp/2.3 ampNoOpen Dripproof (ODP)12 3/4"8 1/4"8 1/4"5/8"1 7/8"3"KeyedB2666135K1130000005990K401000000
    1/23,4504.9 amp/2.5 ampNoOpen Dripproof (ODP)12"8 1/4"8 1/4"5/8"1 7/8"3"KeyedB2666135K1140000005990K401000000
     
    208V AC/230V AC/460V AC, Three Phase
     
    NEMA 56C
    1/21,7251.7 amp/1.6 amp/0.8 ampNoOpen Dripproof (ODP)12 3/4"8 1/4"6 1/4"5/8"1 7/8"3"KeyedB2666135K1210000005990K401000000
     
    230V AC/460V AC, Three Phase
     
    NEMA 56C
    1/31,7251.4 amp/0.7 ampNoOpen Dripproof (ODP)11 1/4"8 1/4"6 1/4"5/8"1 7/8"3"KeyedB2666135K1180000005990K401000000
    1/23,4501.6 amp/0.8 ampNoOpen Dripproof (ODP)11 1/4"8 1/4"6 1/4"5/8"1 7/8"3"KeyedB2666135K1220000005990K401000000
    3/41,7302.2 amp/1.1 ampNoOpen Dripproof (ODP)12 1/4"9 1/4"7"5/8"1 7/8"3 3/8"KeyedF3116135K1230000005990K403000000
    11,7503.2 amp/1.6 ampNoOpen Dripproof (ODP)12 1/4"9 1/4"7"5/8"1 7/8"3 3/8"KeyedF3116135K1240000005990K403000000
     