McMaster-Carr logo
    Filter by
    System of Measurement
    Shaft Diameter
    Electrical Phase
    Mounting Location
    Shaft Type
    Frequency
    Direction of Operation
    Service Factor
    Power Source
    Insulation Class
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    DFARS Specialty Metals
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    145 Products

    US-Made Base-Mount AC Motors

    Image of Product. Motor with Open Enclosure. Front orientation. Electric Motors. US-Made Base-Mount AC Motors.

    Motor with Open Enclosure

    Image of Product. Motor with Totally Enclosed Enclosure. Front orientation. Electric Motors. US-Made Base-Mount AC Motors.

    Motor with Totally

    Enclosed Enclosure

    Image of Attribute. Front orientation. Contains Annotated. US-Made Base-Mount AC Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. US-Made Base-Mount AC Motors.
    Wound, wired, and assembled in the U.S. These base-mount motors are manufactured for durability and include high-quality bearings, so they hold up to occasional overload conditions and spikes in torque. Rated for continuous duty, they’re often used with equipment that requires constant power, such as fans, pumps, and conveyors. Bolt the base of these motors to any flat surface and connect the shaft to your load.
    Enclosures that are open have vents that let air flow over the motor, which keeps it cool and helps it run efficiently. Use them in clean, dry environments—the enclosure blocks drips and debris that fall from above, but dust and moisture can pass through the vents.
    Enclosures that are totally enclosed don’t have vents, so they can be used in wet and dirty environments. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Open Dripproof (ODP) Motor Enclosure—Open dripproof (ODP) enclosures only have vents.
    Totally Enclosed Air-Over (TEAO) Motor Enclosure—Totally enclosed air-over (TEAO) enclosures don’t have their own fan. They need to be mounted in the airflow of an external fan or blower to keep the motor cool, so they’re often found in HVAC systems.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—Totally enclosed fan-cooled (TEFC) enclosures have an external fan that blows air over the outside of the enclosure to keep the motor cool.
    Vibration-Damping Base—Motors with a vibration-damping base have rubber rings between the base and enclosure to minimize vibration.
    Automatic—Automatic overload protection starts the motor automatically after it cools.
    Manual—Manual overload protection must be reset manually to start the motor after it cools.
    Overload Protection Type—Motors with overload protection turn off in overload conditions to prevent motor damage.
    Drip Covers—Drip covers are recommended when your motor will be mounted with the shaft facing down. They attach to the back side of the motor to prevent moisture from pooling on top.
    Motors
    Drip Covers
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base Type
    Overload Protection
    Type
    Class
    Max. Temp.,
    ° F
    Each
    Each
    115V AC/208V AC/230V AC, Single Phase
     
    NEMA 145T
    1 1/21,72521.0 amp/9.6 amp/10.5 ampNoOpen Dripproof (ODP)14 1/4"10 1/4"9"7/8"2 1/4"3 1/2"KeyedWeldedManualB2665990K1090000000005990K4030000000
    1 1/21,75514.0 amp/7.3 amp/7.0 ampNoTotally Enclosed Fan-Cooled (TEFC)14 1/8"9 1/2"9 1/4"7/8"2 1/4"3 1/2"KeyedWeldedF3115990K1250000005990K404000000
     
    115V AC/230V AC, Single Phase
     
    NEMA 48
    1/41,7252.6 amp/1.3 ampNoOpen Dripproof (ODP)10"8"8 1/4"1/2"1 1/2"3"D-ProfileWeldedF3115990K1310000005990K401000000
    1/31,7256.0 amp/3.0 ampNoTotally Enclosed Fan-Cooled (TEFC)10 3/4"8 1/2"7 1/2"1/2"1 1/2"3"D-ProfileWeldedB2665990K1230000005990K402000000
    1/31,7403.4 amp/1.7 ampNoOpen Dripproof (ODP)9 3/4"9"8 1/8"1/2"1 1/2"3"D-ProfileWeldedF3115990K1510000005990K401000000
    1/21,7254.7 amp/2.4 ampNoOpen Dripproof (ODP)10 3/4"8"8 1/4"1/2"1 1/2"3"D-ProfileWeldedB2665990K1320000005990K401000000
    1/21,7257.4 amp/3.7 ampNoTotally Enclosed Fan-Cooled (TEFC)11 1/2"8 1/2"7 1/2"1/2"1 1/2"3"D-ProfileWeldedB2665990K1240000005990K402000000
    1/23,4504.9 amp/2.5 ampNoOpen Dripproof (ODP)10"8"8 1/4"1/2"1 1/2"3"D-ProfileWeldedF3115990K1330000005990K401000000
     
    NEMA 48Z
    1/41,7004.8 amp/2.4 ampNoTotally Enclosed Air-Over (TEAO)11 1/2"6 3/4"8 1/4"1/2"2 1/2"3"D-ProfileVibration DampingAutomaticB2665990K202000000———0
    1/31,7005.6 amp/2.8 ampNoTotally Enclosed Air-Over (TEAO)12"6 3/4"8 1/4"1/2"2 1/2"3"D-ProfileVibration DampingAutomaticB2665990K203000000———0
     
    NEMA 56
    1/31,7256.0 amp/3.0 ampNoOpen Dripproof (ODP)11"7"8"5/8"1 7/8"3 1/2"KeyedVibration DampingAutomaticB2665990K1220000005990K401000000
    1/31,7403.4 amp/1.7 ampNoOpen Dripproof (ODP)10 1/8"8"8 5/8"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1520000005990K401000000
    1/21,7254.7 amp/2.4 ampNoOpen Dripproof (ODP)11"8"8 3/4"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1340000005990K401000000
    1/21,7257.4 amp/3.7 ampNoTotally Enclosed Fan-Cooled (TEFC)12"9"8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticB2665990K350000005990K402000000
    1/21,7258.4 amp/4.2 ampNoOpen Dripproof (ODP)11 3/4"7"8"5/8"1 7/8"3 1/2"KeyedVibration DampingAutomaticB2665990K170000005990K401000000
    1/23,4507.0 amp/3.5 ampNoTotally Enclosed Fan-Cooled (TEFC)11 1/2"8 1/2"8 3/4"5/8"1 7/8"3 1/2"KeyedWeldedB2665990K710000005990K402000000
    3/41,7258.2 amp/4.1 ampNoTotally Enclosed Fan-Cooled (TEFC)12 1/2"9"8 3/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticB2665990K360000005990K402000000
    3/41,7258.4 amp/4.2 ampNoTotally Enclosed Fan-Cooled (TEFC)12 1/2"8 1/2"8 3/4"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K730000005990K402000000
    3/41,72510.0 amp/5.0 ampNoOpen Dripproof (ODP)12 1/2"7"8"5/8"1 7/8"3 1/2"KeyedVibration DampingAutomaticB2665990K210000005990K401000000
    3/41,7506.5 amp/3.3 ampNoOpen Dripproof (ODP)12 1/4"9"9"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1360000005990K403000000
    3/43,4506.3 amp/3.3 ampNoOpen Dripproof (ODP)11"8"8 3/4"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1370000005990K401000000
    3/43,4509.6 amp/4.8 ampNoTotally Enclosed Fan-Cooled (TEFC)12"8 1/2"8 3/4"5/8"1 7/8"3 1/2"KeyedWeldedB2665990K720000005990K402000000
    11,7508.4 amp/4.2 ampNoOpen Dripproof (ODP)12 1/4"9"9"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1380000005990K403000000
    13,4807.8 amp/3.9 ampNoOpen Dripproof (ODP)12 1/4"9"9"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1390000005990K403000000
     
    NEMA 56H
    1 1/21,72512.2 amp/6.1 ampNoTotally Enclosed Fan-Cooled (TEFC)14"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedB2665990K810000005990K404000000
    1 1/21,72512.4 amp/6.2 ampNoOpen Dripproof (ODP)14"9 3/4"9"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K153000000005990K403000000
    1 1/23,48011.8 amp/5.9 ampNoOpen Dripproof (ODP)12 3/4"9"9"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1420000005990K403000000
     
    NEMA 56/NEMA 56H
    3/41,1407.8 amp/4.2 ampNoTotally Enclosed Fan-Cooled (TEFC)13"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedB2665990K74000000005990K404000000
    11,72512.5 amp/6.3 ampNoTotally Enclosed Fan-Cooled (TEFC)13"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K760000005990K404000000
    11,72513.0 amp/6.5 ampNoOpen Dripproof (ODP)11 1/2"7"9"5/8"1 7/8"3 1/2"KeyedVibration DampingAutomaticB2665990K310000005990K403000000
    11,72513.0 amp/6.5 ampNoTotally Enclosed Fan-Cooled (TEFC)13"10"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3115990K990000005990K404000000
    13,45011.8 amp/5.9 ampNoTotally Enclosed Fan-Cooled (TEFC)13"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedB2665990K750000005990K404000000
    13,45012.0 amp/6.0 ampNoTotally Enclosed Fan-Cooled (TEFC)13"10"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedManualB2665990K1010000005990K404000000
    1 1/23,45016.0 amp/8.0 ampNoTotally Enclosed Fan-Cooled (TEFC)13"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedB2665990K790000005990K404000000
    23,45023.0 amp/11.5 ampNoTotally Enclosed Fan-Cooled (TEFC)14"10"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedManualB2665990K102000000005990K404000000
    23,47015.6 amp/7.8 ampNoOpen Dripproof (ODP)14"9"9"5/8"1 7/8"3 1/2"KeyedWeldedF3115990K1410000005990K403000000
     
    NEMA 56YZ
    1/21,7005.2 amp/2.6 ampNoTotally Enclosed Air-Over (TEAO)12 3/4"7"8 3/4"5/8"3"3 1/2"KeyedVibration DampingAutomaticB2665990K215000000———0
     
    NEMA 56Z
    1/21,1005.2 amp/2.6 ampNoTotally Enclosed Air-Over (TEAO)13 3/4"7 1/2"9"5/8"3"3 1/2"KeyedVibration DampingAutomaticB2665990K204000000———0
     
    NEMA 143T
    11,72512.8 amp/6.4 ampNoTotally Enclosed Fan-Cooled (TEFC)13 1/2"9 1/2"9 1/4"7/8"2 1/4"3 1/2"KeyedWeldedF3115990K1120000005990K404000000
     

    Base-Mount AC Motors

    Image of Product. Motor with Totally Enclosed Enclosure. Front orientation. Electric Motors. Base-Mount AC Motors.
    Image of Product. Motor with Open Enclosure. Front orientation. Electric Motors. Base-Mount AC Motors.

    Motor with Totally

    Enclosed Enclosure

    Motor with Open Enclosure

    Image of Attribute. Front orientation. Contains Annotated. Base-Mount AC Motors.
    Image of Attribute. Side1 orientation. Contains Annotated. Base-Mount AC Motors.
    To get equipment moving, bolt the base of these motors to any flat surface and connect the shaft to your load. They’re rated for continuous duty, so they’re often used with equipment that requires constant power, like fans, pumps, and conveyors.
    Motors with a NEMA frame size have an oversized shaft and high-quality bearings to stand up to heavy and side loads better than even our domestic motors. Densely packed windings and thin laminations ensure the motor stays cool and runs efficiently.
    Motors with an IEC frame size meet international standards for electrical products. Their compact body fits in tight spaces.
    Open Dripproof (ODP) Motor Enclosure—Open dripproof (ODP) enclosures have vents that let air flow over the motor, which keeps it cool and helps it run efficiently. Use them in clean, dry environments—the enclosure blocks drips and debris that fall from above, but dust and moisture can pass through the vents.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—Totally enclosed fan-cooled (TEFC) enclosures don’t have vents, so they can be used in wet and dirty environments. They have an external fan that blows air over the outside of the enclosure to keep the motor cool. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Automatic—Motors with automatic overload protection turn off in overload conditions to prevent damage. Once they cool down, they start again automatically.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load
    Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Overload Protection
    Type
    Class
    Max. Temp.,
    ° F
    Each
    115V AC/230V AC, Single Phase
     
    NEMA 56
    1/41,7352.7 amp/1.4 ampNoTotally Enclosed Fan-Cooled (TEFC)11 1/4"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N1060000000
    1/41,7402.8 amp/1.4 ampNoOpen Dripproof (ODP)11 1/8"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N105000000
    1/31,7353.5 amp/1.8 ampNoTotally Enclosed Fan-Cooled (TEFC)11 1/4"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N107000000
    1/31,7403.7 amp/1.9 ampNoOpen Dripproof (ODP)11 3/4"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N33000000
    1/33,5003.4 amp/1.7 ampNoTotally Enclosed Fan-Cooled (TEFC)12 1/2"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N108000000
    1/21,7304.9 amp/2.5 ampNoTotally Enclosed Fan-Cooled (TEFC)12"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N42000000
    1/21,7405.1 amp/2.5 ampNoOpen Dripproof (ODP)12 3/8"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N32000000
    1/23,5104.8 amp/2.4 ampNoTotally Enclosed Fan-Cooled (TEFC)12"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N43000000
    1/23,5104.9 amp/2.5 ampNoOpen Dripproof (ODP)11 3/4"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N103000000
    3/41,7307.0 amp/3.5 ampNoTotally Enclosed Fan-Cooled (TEFC)12 1/2"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N45000000
    3/43,5106.8 amp/3.4 ampNoOpen Dripproof (ODP)12 3/8"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N36000000
    3/43,5106.8 amp/3.4 ampNoTotally Enclosed Fan-Cooled (TEFC)12 1/2"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N44000000
     
    NEMA 56H
    3/41,7506.5 amp/3.3 ampNoOpen Dripproof (ODP)12 3/8"8"7 7/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N35000000
    1 1/21,74012.8 amp/6.4 ampNoTotally Enclosed Fan-Cooled (TEFC)13 3/4"8 3/4"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N57000000
    1 1/23,50012.2 amp/6.1 ampNoOpen Dripproof (ODP)13 3/4"8 1/2"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N58000000
     
    NEMA 56/NEMA 56H
    11,7409.1 amp/4.5 ampNoTotally Enclosed Fan-Cooled (TEFC)13"8 3/4"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N54000000
    11,7508.8 amp/4.4 ampNoOpen Dripproof (ODP)13 3/4"8 1/2"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N29000000
    13,5009.0 amp/4.5 ampNoTotally Enclosed Fan-Cooled (TEFC)13"8 3/4"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N55000000
    1 1/23,50012.2 amp/6.1 ampNoTotally Enclosed Fan-Cooled (TEFC)13 3/4"8 3/4"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N53000000
    21,74016.1 amp/8.0 ampNoOpen Dripproof (ODP)15 3/4"8 1/2"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N52000000
    23,50016.4 amp/8.2 ampNoTotally Enclosed Fan-Cooled (TEFC)13 3/4"8 3/4"8 1/4"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticF3117014N56000000
     
    NEMA 143T
    11,7409.1 amp/4.5 ampNoTotally Enclosed Fan-Cooled (TEFC)13 3/8"8 3/4"8 1/4"7/8"2 1/4"3 1/2"KeyedWeldedAutomaticF3117014N12000000
     
    NEMA 145T
    1 1/21,74012.8 amp/6.4 ampNoTotally Enclosed Fan-Cooled (TEFC)14 1/8"8 3/4"8 1/4"7/8"2 1/4"3 1/2"KeyedWeldedAutomaticF3117014N19000000
     
    NEMA 143T/NEMA 145T
    1 1/21,74011.9 amp/5.9 ampNoOpen Dripproof (ODP)15 1/4"8 1/2"8 1/4"7/8"2 1/4"3 1/2"KeyedWeldedAutomaticF3117014N17000000
     

    US-Made Face-Mount AC Motors

    Image of Product. Motor with Totally Enclosed Enclosure. Front orientation. Electric Motors. US-Made Face-Mount AC Motors .
    Image of Product. Motor with Open Enclosure. Front orientation. Electric Motors. US-Made Face-Mount AC Motors .

    Motor with Totally Enclosed

    Enclosure

    Motor with Open Enclosure

    Image of Attribute. Front orientation. Contains Annotated. US-Made Face-Mount AC Motors .
    Image of Attribute. Side1 orientation. Contains Annotated. US-Made Face-Mount AC Motors .
    Wound, wired, and assembled in the U.S. These motors are manufactured for durability and include high-quality bearings, so they hold up to occasional overload conditions and spikes in torque. They bolt directly to gearboxes, pumps, and other machinery. These motors are more compact than base-mount motors and the direct, rigid connection to your equipment keeps them aligned. Rated for continuous duty, they’re often used with equipment that requires constant power, like fans, pumps, and conveyors.
    Enclosures that are open have vents that let air flow over the motor, which keeps it cool and helps it run efficiently. Use them in clean, dry environments—the enclosure blocks drips and debris that fall from above, but dust and moisture can pass through the vents.
    Enclosures that are totally enclosed don’t have vents, so they can be used in wet and dirty environments. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Open Dripproof (ODP) Motor Enclosure—Open dripproof (ODP) enclosures have vents.
    Open Dripproof Tandem Fan (ODTF) Motor Enclosure—Open dripproof tandem fan (ODTF) enclosures have vents and an external fan that blows air over the motor.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—Totally enclosed fan-cooled (TEFC) enclosures have an external fan that blows air over the outside of the enclosure to keep the motor cool.
    Drip Covers—Drip covers are recommended when your motor will be mounted with the shaft facing down. They attach to the back side of the motor to prevent moisture from pooling on top.
    Motors
    Drip Covers
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Each
    Each
    115V AC/208V AC/230V AC, Single Phase
     
    NEMA 56C
    1/33,4506.0 amp/3.2 amp/3.0 ampNoTotally Enclosed Fan-Cooled (TEFC)11 1/2"8 1/2"7 1/2"5/8"1 7/8"3"KeyedB2666135K21300000005990K4020000000
    23,45023.0 amp/12.0 amp/11.5 ampNoTotally Enclosed Fan-Cooled (TEFC)14 1/4"9 1/2"9 1/4"5/8"1 7/8"3 5/8"KeyedF3116135K209000000005990K404000000
     
    115V AC/230V AC, Single Phase
     
    NEMA 56C
    1/41,7252.6 amp/1.3 ampNoOpen Dripproof (ODP)12"8 1/4"8 1/4"5/8"1 7/8"3"KeyedB2666135K1110000005990K401000000
    1/41,7255.0 amp/2.5 ampNoTotally Enclosed Fan-Cooled (TEFC)11 1/2"8 1/2"7 1/2"5/8"1 7/8"3"KeyedB2666135K2110000005990K402000000
    1/31,7256.0 amp/3.0 ampNoTotally Enclosed Fan-Cooled (TEFC)11 1/2"8 1/2"7 1/2"5/8"1 7/8"3"KeyedB2666135K2120000005990K402000000
    1/31,7403.4 amp/1.7 ampNoOpen Dripproof (ODP)12"8 1/4"8 1/4"5/8"1 7/8"3"KeyedB2666135K1120000005990K401000000
    1/21,7254.7 amp/2.3 ampNoOpen Dripproof (ODP)12 3/4"8 1/4"8 1/4"5/8"1 7/8"3"KeyedB2666135K1130000005990K401000000
    1/21,7257.4 amp/3.7 ampNoTotally Enclosed Fan-Cooled (TEFC)12"8 1/2"7 1/2"5/8"1 7/8"3"KeyedB2666135K2010000005990K402000000
    1/23,4504.9 amp/2.5 ampNoOpen Dripproof (ODP)12"8 1/4"8 1/4"5/8"1 7/8"3"KeyedB2666135K1140000005990K401000000
    1/23,4507.0 amp/3.5 ampNoTotally Enclosed Fan-Cooled (TEFC)11 1/2"8 1/2"8 1/4"5/8"1 7/8"3"KeyedB2666135K2020000005990K402000000
    3/41,7258.4 amp/4.2 ampNoTotally Enclosed Fan-Cooled (TEFC)12 1/2"8 1/2"8 1/4"5/8"1 7/8"3"KeyedF3116135K2030000005990K402000000
    3/43,4509.6 amp/4.8 ampNoTotally Enclosed Fan-Cooled (TEFC)12"8 1/2"8 1/4"5/8"1 7/8"3"KeyedB2666135K2040000005990K402000000
    11,72512.5 amp/6.3 ampNoTotally Enclosed Fan-Cooled (TEFC)13 1/4"9 1/2"9 1/4"5/8"1 7/8"3 5/8"KeyedF3116135K2050000005990K404000000
    11,7508.8 amp/4.4 ampNoOpen Dripproof Tandem Fan (ODTF)13 1/4"9 1/4"9"5/8"1 7/8"3 3/8"KeyedF3116135K116000000005990K403000000
    13,45011.8 amp/5.9 ampNoTotally Enclosed Fan-Cooled (TEFC)12 1/4"9 1/2"9 1/4"5/8"1 7/8"3 5/8"KeyedB2666135K2060000005990K404000000
    1 1/21,72512.2 amp/6.1 ampNoTotally Enclosed Fan-Cooled (TEFC)14 1/4"9 1/2"9"5/8"1 7/8"3 3/8"KeyedF3116135K2070000005990K404000000
    1 1/23,45016.0 amp/8.0 ampNoTotally Enclosed Fan-Cooled (TEFC)13 1/4"9 1/2"9 1/4"5/8"1 7/8"3 5/8"KeyedB2666135K2080000005990K404000000
     

    AC Gearmotors

    Turn speed into torque with these AC-powered gearmotors—they combine a motor and a speed reducer into one. You can wire them for clockwise or counterclockwise rotation; instructions are included. The parallel shaft transmits motion inline with the motor.
    Base Mount
    Image of Product. Front orientation. Electric Gearmotors. AC Gearmotors.
    Image of Attribute. Front orientation. Contains Annotated. AC Gearmotors.
    Image of Attribute. Side1 orientation. Contains Annotated. AC Gearmotors.
    Base-mount motors come with a base, so they can be secured to a flat surface.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—TEFC (totally enclosed fan cooled) motors have an enclosure to protect them from dirt, dust, and moisture. An external fan blows air on the enclosure to keep them cool.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Speed @ Continuous
    Operating Torque
    Full Load Current,
    amp
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Gear Type
    Bearing
    Type
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Class
    Max. Temp.,
    ° F
    Enclosure
    Rating
    Each
    115/230V AC, Single Phase
    1/412 rpm @ 1,030 in·lbf5.4/2.7NoTotally Enclosed Fan-Cooled (TEFC)13 1/2"8 1/4"7 3/4"Helical, SpurBall
    3/4"1 1/2"3"B266IP43
    4863N28000000000
    1/426 rpm @ 569 in·lbf5.4/2.7NoTotally Enclosed Fan-Cooled (TEFC)13 1/2"8 1/4"7 3/4"Helical, SpurBall
    3/4"1 1/2"3"B266IP43
    4863N2900000000
    1/222 rpm @ 1,105 in·lbf8.8/4.4NoTotally Enclosed Fan-Cooled (TEFC)14 1/4"8 1/4"7 3/4"Helical, SpurBall
    3/4"1 1/2"3"F311IP43
    4863N3100000000
    1/259 rpm @ 496 in·lbf8.8/4.4NoTotally Enclosed Fan-Cooled (TEFC)14 1/4"8 1/4"7 3/4"Helical, SpurBall
    3/4"1 1/2"3"F311IP43
    4863N3200000000
    1/291 rpm @ 336 in·lbf8.8/4.4NoTotally Enclosed Fan-Cooled (TEFC)14 1/4"8 1/4"7 3/4"Helical, SpurBall
    3/4"1 1/2"3"F311IP43
    4863N3300000000
    1/2133 rpm @ 229 in·lbf8.8/4.4NoTotally Enclosed Fan-Cooled (TEFC)14 1/4"8 1/4"7 3/4"Helical, SpurBall
    3/4"1 1/2"3"F311IP43
    4863N3400000000
     
    Face Mount
    Image of Product. Front orientation. Electric Gearmotors. AC Gearmotors.
    Image of Attribute. Front orientation. Contains Annotated. AC Gearmotors.
    Image of Attribute. Side1 orientation. Contains Annotated. AC Gearmotors.
    Face-mount motors bolt directly to your equipment.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—TEFC (totally enclosed fan cooled) motors have an enclosure to protect them from dirt, dust, and moisture. An external fan blows air on the enclosure to keep them cool.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Speed @ Continuous
    Operating Torque
    Full Load
    Current, amp
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Gear Type
    Bearing
    Type
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Class
    Max. Temp.,
    ° F
    Enclosure
    Rating
    Each
    115V AC, Single Phase
    1/1528 rpm @ 100 in·lbf0.9NoTotally Enclosed Fan-Cooled (TEFC)9 3/4"3 3/4"3 3/4"Helical, SpurBall
    1/2"1"2.78"F311IP43
    4863N160000000
    1/1557 rpm @ 56 in·lbf0.9NoTotally Enclosed Fan-Cooled (TEFC)9 3/4"3 3/4"3 3/4"Helical, SpurBall
    1/2"1"3"F311IP43
    4863N17000000
    1/1594 rpm @ 36 in·lbf0.9NoTotally Enclosed Fan-Cooled (TEFC)9 3/4"3 3/4"3 3/4"Helical, SpurBall
    1/2"1"3"F311IP43
    4863N18000000
    1/15142 rpm @ 24 in·lbf0.9NoTotally Enclosed Fan-Cooled (TEFC)9 1/4"3 3/4"3 3/4"Helical, SpurBall
    1/2"1"3"F311IP43
    4863N19000000
    1/15283 rpm @ 12 in·lbf0.9NoTotally Enclosed Fan-Cooled (TEFC)9 1/4"3 3/4"3 3/4"Helical, SpurBall
    1/2"1"3"F311IP43
    4863N21000000
     
    Base/Face Mount
    Image of Product. Front orientation. Electric Gearmotors. AC Gearmotors.
    Image of Attribute. Front orientation. Contains Annotated. AC Gearmotors.
    Image of Attribute. Side1 orientation. Contains Annotated. AC Gearmotors.
    Base/face-mount motors give you the flexibility to mount directly onto equipment or to the included base.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—TEFC (totally enclosed fan cooled) motors have an enclosure to protect them from dirt, dust, and moisture. An external fan blows air on the enclosure to keep them cool.
    Totally Enclosed Nonventilated (TENV) Motor Enclosure—TENV (totally enclosed non-ventilated) enclosures are similar to TEFC motor enclosures, except they do not have a fan. They rely on air circulation from the motion of the motor for cooling.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Speed @ Continuous
    Operating Torque
    Full Load Current,
    amp
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Gear Type
    Bearing
    Type
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Class
    Max. Temp.,
    ° F
    Enclosure
    Rating
    Each
    115/230V AC, Single Phase
    1/158 rpm @ 345 in·lbf1/0.5NoTotally Enclosed Nonventilated (TENV)10 1/2"5"5 1/4"Helical, SpurBall
    5/8"1 1/2"3 1/2"F311IP43
    4863N220000000
    1/1515 rpm @ 250 in·lbf1/0.5NoTotally Enclosed Nonventilated (TENV)10 1/2"5"5 1/4"Helical, SpurBall
    5/8"1 1/2"3 1/2"F311IP43
    4863N23000000
    1/630 rpm @ 295 in·lbf2.1/1.1NoTotally Enclosed Fan-Cooled (TEFC)12 1/4"5"5 1/4"Helical, SpurBall
    5/8"1 1/2"3 1/2"F311IP43
    4863N24000000
    1/640 rpm @ 219 in·lbf2/1NoTotally Enclosed Fan-Cooled (TEFC)12 1/4"5"5 1/4"Helical, SpurBall
    5/8"1 1/2"3 1/2"F311IP43
    4863N25000000
    1/690 rpm @ 103 in·lbf2.1/1.1NoTotally Enclosed Fan-Cooled (TEFC)12 1/4"5"5 1/4"Helical, SpurBall
    5/8"1 1/2"3 1/2"F311IP43
    4863N26000000
    1/6156 rpm @ 60 in·lbf2/1NoTotally Enclosed Fan-Cooled (TEFC)12 1/4"5"5 1/4"Helical, SpurBall
    5/8"1 1/2"3 1/2"F311IP43
    4863N27000000
    1/447 rpm @ 294 in·lbf2.35/1.25NoTotally Enclosed Fan-Cooled (TEFC)11 1/2"7"5 1/4"Helical, SpurBall, Roller
    3/4"1 1/2"3.56"B266IP44
    4863N11000000
    1/488 rpm @ 163 in·lbf2.35/1.25NoTotally Enclosed Fan-Cooled (TEFC)11 1/2"7"5 1/4"Helical, SpurBall, Roller
    3/4"1 1/2"3.56"B266IP44
    4863N12000000
    1/4113 rpm @ 128 in·lbf2.35/1.25NoTotally Enclosed Fan-Cooled (TEFC)11 1/2"7"5 1/4"Helical, SpurBall, Roller
    3/4"1 1/2"3.56"B266IP44
    4863N13000000
    1/4159 rpm @ 91 in·lbf2.35/1.25NoTotally Enclosed Fan-Cooled (TEFC)11 1/2"7"5 1/4"Helical, SpurBall, Roller
    3/4"1 1/2"3.56"B266IP44
    4863N14000000
    1/4338 rpm @ 41 in·lbf2.35/1.25NoTotally Enclosed Fan-Cooled (TEFC)11 1/2"7"5 1/4"Helical, SpurBall, Roller
    3/4"1 1/2"3.56"B266IP44
    4863N15000000
     

    US-Made Base/Face-Mount AC Motors

    Image of Product. Front orientation. Electric Motors. US-Made Base/Face-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. US-Made Base/Face-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. US-Made Base/Face-Mount AC Motors.
    Wound, wired, and assembled in the U.S. These motors are manufactured for durability and include high-quality bearings, so they hold up to occasional overload conditions and spikes in torque. Whether you’re switching between jobs or need flexibility during installation, these motors give you a variety of mounting options. Mount the feet to a flat surface or bolt the face directly to a gearbox, pump, or other machine. You can also do both at once for added stability in applications with high loads or vibration. They’re rated for continuous duty, so they’re often used with equipment that requires constant power, such as fans, pumps, and conveyors.
    Enclosures that are totally enclosed don’t have vents, so they can be used in wet and dirty environments. They’re not airtight, but since air isn’t flowing inside the enclosure, the motor won’t run as efficiently as it would in an open enclosure.
    Totally Enclosed Fan-Cooled (TEFC) Motor Enclosure—Totally enclosed fan-cooled (TEFC) enclosures have an external fan that blows air over the outside of the enclosure to keep the motor cool.
    Drip Covers—Drip covers are recommended when your motor will be mounted with the shaft facing down. They attach to the back side of the motor to prevent moisture from pooling on top.
    Motors
    Drip Covers
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Class
    Max. Temp.,
    ° F
    Enclosure
    Rating
    Each
    Each
    115V AC/208V AC/230V AC, Single Phase
     
    NEMA 56C
    1/31,7256.0 amp/3.6 amp/3.0 ampNoTotally Enclosed Fan-Cooled (TEFC)11 1/2"8 1/2"8"5/8"1 7/8"3 1/2"KeyedWeldedB26659845K1100000005990K4020000000
    1/21,7257.4 amp/4.1 amp/3.7 ampNoTotally Enclosed Fan-Cooled (TEFC)12 1/4"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedF311IP55
    59845K410000005990K404000000
    1/21,7257.4 amp/4.3 amp/3.7 ampNoTotally Enclosed Fan-Cooled (TEFC)12"8 1/2"8"5/8"1 7/8"3 1/2"KeyedWeldedB26659845K120000005990K402000000
    1/23,4507.0 amp/4.1 amp/3.5 ampNoTotally Enclosed Fan-Cooled (TEFC)11 1/2"8 1/2"8 3/4"5/8"1 7/8"3 1/2"KeyedWeldedB26659845K130000005990K402000000
    3/41,7258.4 amp/5.4 amp/4.2 ampNoTotally Enclosed Fan-Cooled (TEFC)12 1/2"8 1/2"8 3/4"5/8"1 7/8"3 1/2"KeyedWeldedF31159845K140000005990K402000000
    3/41,72511.0 amp/7.0 amp/5.5 ampNoTotally Enclosed Fan-Cooled (TEFC)12 1/4"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedF311IP55
    59845K42000000005990K404000000
    11,72512.8 amp/7.0 amp/6.4 ampNoTotally Enclosed Fan-Cooled (TEFC)13 1/4"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedF31159845K150000005990K404000000
    11,72512.8 amp/7.0 amp/6.4 ampNoTotally Enclosed Fan-Cooled (TEFC)13 1/4"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedF311IP55
    59845K44000000005990K404000000
    13,45011.8 amp/6.1 amp/5.9 ampNoTotally Enclosed Fan-Cooled (TEFC)12 1/4"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedB26659845K160000005990K404000000
    1 1/21,72512.4 amp/6.8 amp/6.2 ampNoTotally Enclosed Fan-Cooled (TEFC)14 1/4"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedF311IP55
    59845K45000000005990K404000000
    1 1/23,45015.0 amp/7.9 amp/7.5 ampNoTotally Enclosed Fan-Cooled (TEFC)13 1/4"9 1/2"9 1/4"5/8"1 7/8"3 1/2"KeyedWeldedF31159845K170000005990K404000000
     

    Hazardous Location Base-Mount AC Motors

    Image of Product. Front orientation. Electric Motors. Hazardous Location Base-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. Hazardous Location Base-Mount AC Motors.
    Image of Attribute. Front orientation. Contains Annotated. Hazardous Location Base-Mount AC Motors.
    These motors are rated for environments where hazardous material is present. They are continuous duty and mount horizontally. You can wire for clockwise or counterclockwise rotation; instructions are included. The base is welded to the enclosure.
    Automatic—Motors with automatic overload protection turn off in overload conditions to prevent motor damage and start automatically after they cool.
    Hazardous Location Rating—Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
    Overall
    Shaft
    Insulation
    Power,
    hp
    Max. Rotation
    Speed, rpm
    Full Load Current
    Inverter
    Rated
    Motor Enclosure Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr. to
    Base
    Type
    Base
    Type
    Overload Protection
    Type
    Class
    Max. Temp.,
    ° F
    Hazardous Location Rating
    Each
    115V AC/208V AC/230V AC, Single Phase
     
    NEMA 48
    1/41,8005.0 amp/2.6 amp/2.5 ampNoTotally Enclosed Fan-Cooled (TEFC)12 7/8"7 1/4"8 1/8"1/2"1 1/2"3"D-ProfileWeldedAutomaticB104NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    4980N210000000
     
    NEMA 56
    1/21,8007.4 amp/3.9 amp/3.7 ampNoTotally Enclosed Fan-Cooled (TEFC)14 1/4"8 3/8"9 1/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticB104NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    4980N22000000
     
    115V AC/230V AC, Single Phase
     
    NEMA 56
    11,80012.4 amp/6.2 ampNoTotally Enclosed Fan-Cooled (TEFC)15 1/4"8 3/8"9 1/8"5/8"1 7/8"3 1/2"KeyedWeldedAutomaticB104NEC Class I Divisions 1, 2 Group D; NEC Class II Divisions 1, 2 Groups F, G
    4980N2300000000
     

    Base/Face-Mount Compact AC Gearmotors

    Image of Product. Front orientation. Contains Annotated. Electric Gearmotors. Base/Face-Mount Compact AC Gearmotors.
    Image of Attribute. Front orientation. Contains Annotated. Base/Face-Mount Compact AC Gearmotors.
    Sized for small spaces, these gearmotors mount from the base or face for flexibility to fit in tight locations. Each has a motor matched with a speed reducer to lower speed while increasing torque. A plastic fan is included to improve cooling when using the gearmotor in a clockwise direction.
    To reverse the direction of the gearmotor, loosen the mounting screws, remove the stator, and rotate it 180°. You’ll also need to replace the original fan blades with fan blades for counterclockwise shaft rotation (sold separately).
    Gearmotors
    Replacement Fan Blades for
    Counterclockwise Shaft Rotation
    Overall
    Shaft
    Insulation
    Max. Rotation
    Speed, rpm
    Torque @ Max.
    Speed, in·lbf
    Power,
    hp
    Radial Load
    Cap., lb.
    Full Load
    Current, amp
    Motor Enclosure
    Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Class
    Max. Temp.,
    ° F
    Certification
    Each
    Each
    115V AC, Single Phase
    1501/300250.4Open4 1/2"3 1/4"3 1/4"0.31"1"1 5/8"B266UL Recognized Component, CSA Certified
    6142K510000006142K6500000
    3501/300250.4Open4 1/2"3 1/4"3 1/4"0.31"1"1 5/8"B266UL Recognized Component, CSA Certified
    6142K52000006142K650000
    5401/300250.4Open4 1/2"3 1/4"3 1/4"0.31"1"1 5/8"B266UL Recognized Component, CSA Certified
    6142K53000006142K660000
    10401/150251Open4 3/4"3 1/4"3 1/4"0.31"1"1 5/8"B266UL Recognized Component, CSA Certified
    6142K54000006142K660000
    20201/150251Open4 3/4"3 1/4"3 1/4"0.31"1"1 5/8"B266UL Recognized Component, CSA Certified
    6142K55000006142K660000
    35151/120251.2Open5"3 1/4"3 1/4"0.31"1"1 5/8"B266UL Recognized Component, CSA Certified
    6142K56000006142K650000
    50151/80251.6Open5 1/4"3 1/4"3 1/4"0.31"1"1 5/8"B266UL Recognized Component, CSA Certified
    6142K57000006142K650000
    75101/80251.6Open5 1/4"3 1/4"3 1/4"0.31"1"1 5/8"B266UL Recognized Component, CSA Certified
    6142K58000006142K650000
    10071/80251.6Open5 1/4"3 1/4"3 1/4"0.31"1"1 5/8"B266UL Recognized Component, CSA Certified
    6142K59000006142K660000
    12561/80251.6Open5 1/4"3 1/4"3 1/4"0.31"1"1 5/8"B266UL Recognized Component, CSA Certified
    6142K71000006142K660000
    15051/80251.6Open5 1/4"3 1/4"3 1/4"0.31"1"1 5/8"B266UL Recognized Component, CSA Certified
    6142K72000006142K660000
    20041/80251.6Open5 1/4"3 1/4"3 1/4"0.31"1"1 5/8"B266UL Recognized Component, CSA Certified
    6142K73000006142K660000
     

    Face-Mount Compact AC Gearmotors

    Image of Product. Front orientation. Contains Annotated. Electric Gearmotors. Face-Mount Compact AC Gearmotors.
    Image of Attribute. Front orientation. Contains Annotated. Face-Mount Compact AC Gearmotors.
    Power equipment in applications with limited space. Gearmotors have a motor matched with a speed reducer to lower speed while increasing torque. A plastic fan is included to improve cooling when using the gearmotor in a clockwise direction.
    To reverse the direction of the gearmotor, loosen the mounting screws, remove the stator, and rotate it 180°. You’ll also need to replace the original fan blades with fan blades for counterclockwise shaft rotation (sold separately).
    Gearmotors
    Replacement Fan Blades for
    Counterclockwise Shaft Rotation
    Overall
    Shaft
    Insulation
    Max. Rotation
    Speed, rpm
    Torque @ Max.
    Speed, in·lbf
    Power,
    hp
    Radial Load
    Cap., lb.
    Full Load
    Current, amp
    Motor Enclosure
    Type
    Lg.
    Wd.
    Ht.
    Dia.
    Lg.
    Ctr.-to-Base
    Lg.
    Class
    Max. Temp.,
    ° F
    Certification
    Each
    Each
    115V AC, Single Phase
    3501/300250.4Open4"2 1/2"3"0.31"1"2.12"B266UL Recognized Component, CSA Certified
    6142K420000006142K6600000
    5501/300250.4Open4"2 1/2"3"0.31"1"2.12"B266UL Recognized Component, CSA Certified
    6142K43000006142K660000
    10401/150251Open4 1/2"2 1/2"3"0.31"1"2.12"B266UL Recognized Component, CSA Certified
    6142K44000006142K660000
    20251/150251Open4 1/2"2 1/2"3"0.31"1"2.12"B266UL Recognized Component, CSA Certified
    6142K45000006142K650000
    35201/120251.2Open4 3/4"2 1/2"3"0.31"1"2.12"B266UL Recognized Component, CSA Certified
    6142K46000006142K650000
    50151/80251.6Open5"2 1/2"3"0.31"1"2.12"B266UL Recognized Component, CSA Certified
    6142K47000006142K650000
    75151/80251.6Open5"2 1/2"3"0.31"1"2.12"B266UL Recognized Component, CSA Certified
    6142K48000006142K660000
    10071/80251.6Open5"2 1/2"3"0.31"1"2.12"B266UL Recognized Component, CSA Certified
    6142K49000006142K660000
    12561/80251.6Open5"2 1/2"3"0.31"1"2.12"B266UL Recognized Component, CSA Certified
    6142K61000006142K660000
    15051/80251.6Open5"2 1/2"3"0.31"1"2.12"B266UL Recognized Component, CSA Certified
    6142K62000006142K660000
    20041/80251.6Open5"2 1/2"3"0.31"1"2.12"B266UL Recognized Component, CSA Certified
    6142K63000006142K660000
     
    back to top