McMaster-Carr logo
    Filter by
    Thermometer Type
    System of Measurement
    Measurement Unit
    Emissivity Adjustability
    Battery Size
    For Surface Type
    Temperature Resolution
    Digital Display Type
    Housing Material
    Number of Batteries
    DFARS Specialty Metals
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Adjustability
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    32 Products

    Pocket Infrared Thermometers

    Image of ProductInUse. Style F (Shown in Use with Smartphone). Front orientation. Thermometers. Pocket Infrared Thermometers, Style F.

    Style F (Shown in

    Use with

    Smartphone)

    Image of Product. Front orientation. Thermometers. Pocket Infrared Thermometers, Style B.
    Image of Product. Front orientation. Thermometers. Pocket Infrared Thermometers, Style C.
    Image of Product. Front orientation. Thermometers. Pocket Infrared Thermometers, Style D.
    Image of Product. Front orientation. Thermometers. Pocket Infrared Thermometers, Style E.

    Style B

    Style C

    Style D

    Style E

    Keep these small thermometers in your pocket or toolkit to spot check the temperature of dangerous, hard-to-reach, and moving surfaces without touching them.
    Warning: These infrared thermometers are not intended for medical use.
    Adjustable Emissivity—Thermometers with adjustable emissivity can be calibrated for more accurate readings of shiny surfaces than thermometers with fixed emissivity.
    Laser Sight—Thermometers with laser sight have a red beam of light to indicate the precise area being measured.
    Bluetooth—Thermometers with Bluetooth wirelessly send temperature results to an app downloaded to your smartphone. Use the app to adjust the emissivity.
    Maximum Distance—Maximum working distance is the distance a one inch target can be reliably measured.
    Batteries
    Style
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    Max.
    Distance
    Emissivity
    Response
    Time, sec.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Includes
    Thermometer Features
    Enclosure
    Rating
    Certification
    Included
    Size
    No.
    of
    Each
    For Dark Surfaces
     
    Fixed Emissivity
    B-27° F to 932° F/-33° C to 500° C0.1/0.1° C±2%6"0.9516"1"1"PlasticAutomatic Shutoff, Backlit Display, Laser SightCE Marked
    YesAA14231K250000000
    C-13° F to 482° F/-25° C to 250° C0.1/0.1° C±2%Not Rated9513 1/8"1 1/4"3/4"PlasticCarrying CaseMin./Max. MemoryIP65
    CE Marked
    YesCR203219212T22000000
     
    For Dark, Light, and Shiny Surfaces
     
    Adjustable Emissivity
    D-22° F to 572° F/-30° C to 300° C0.1/0.1° C±2%6"0.2 to 0.990.54 1/2"1.7"1"PlasticCarrying CaseAutomatic Shutoff, Laser SightIP40
    CE Marked
    YesAAA29212T21000000
    E32° F to 932° F/0° C to 500° C1° F/1° C±3.6° F/±2° C15 ft.0.7 to 0.9516 5/16"1 11/16"1 11/16"PlasticAutomatic Shutoff, Laser SightIP67
    CE Marked
    Yes9V16614T31000000
     
    For Dark, Dull, Light, and Shiny Surfaces
     
    Adjustable Emissivity
    F-22° F to 480° F/-30° C to 250° C0.1/0.1° C±2.7%0.1 to 115 1/2"1 3/8"1"PlasticData Logging Capabilities, Laser Sight, Bluetooth, Min./Max. MemoryCE Marked
    YesAAA34231K27000000
     

    Infrared Thermometers with Calibration Certificate

    Image of Product. Front orientation. Thermometers. Infrared Thermometers with Calibration Certificate, Style A.
    Image of Product. Front orientation. Thermometers. Infrared Thermometers with Calibration Certificate, Style B.
    Image of Product. Front orientation. Thermometers. Infrared Thermometers with Calibration Certificate, Style C.
    Image of Product. Front orientation. Thermometers. Infrared Thermometers with Calibration Certificate, Style D.

    Style A

    Style B

    Style C

    Style D

    Image of Product. Front orientation. Thermometers. Infrared Thermometers with Calibration Certificate, Style E.
    Image of Product. Front orientation. Thermometers. Infrared Thermometers with Calibration Certificate, Style F.
    Image of Product. Front orientation. Thermometers. Infrared Thermometers with Calibration Certificate, Style G.
    Image of Product. Front orientation. Thermometers. Infrared Thermometers with Calibration Certificate, Style H.

    Style E

    Style F

    Style G

    Style H

    Ensure the accuracy of noncontact temperature readings of dangerous and inaccessible surfaces with these thermometers that come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy.
    Warning: These infrared thermometers are not intended for medical use.
    Adjustable Emissivity—Thermometers with adjustable emissivity can be calibrated for more accurate readings of shiny surfaces than thermometers with fixed emissivity.
    Maximum Distance—Maximum working distance is the distance a one inch target can be reliably measured.
    Batteries
    Style
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    Max.
    Distance
    Emissivity
    Response
    Time, sec.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Includes
    Thermometer Features
    Certification
    Included
    Size
    No.
    of
    Each
    For Dark Surfaces
     
    Fixed Emissivity
    A-76° F to 932° F/-60° C to 500° C0.1/0.1° C±2%Not Rated0.9517"1 1/2"3"PlasticAutomatic Shutoff, Laser SightCE Marked
    YesAAA29248T570000000
    B-58° F to 1,832° F/-50° C to 1,000° C0.1/0.1° C±1.5%Not Rated0.9519"2 1/4"4"PlasticCarrying CaseAutomatic Shutoff, Laser SightCE Marked
    Yes9V140045K51000000
     
    For Dark, Light, and Shiny Surfaces
     
    Fixed Emissivity
    B-4° F to 630° F/-20° C to 330° C0.1/0.1° C±2%Not Rated0.950.56 1/4"1 9/16"3 3/16"PlasticCarrying CaseAutomatic Shutoff, Laser SightCE Marked
    Yes9V19254T913000000
     
    Adjustable Emissivity
    C-58° F to 1,200° F/-50° C to 650° C0.1/0.1° C±1%12"0.1 to 116 3/8"1 5/8"3 1/4"PlasticCarrying CaseAutomatic Shutoff, Laser SightCE Marked
    Yes9V19254T72000000
    D-40° F to 1,202° F/-40° C to 650° C0.1/0.1° C±1%30"0.1 to 117"2"6 1/2"PlasticCarrying CaseAutomatic Shutoff, Laser SightCE Marked
    YesAA211175K53000000
    D-40° F to 1,472° F/-40° C to 800° C0.1/0.1° C±1%50"0.1 to 117"2"6 1/2"PlasticCarrying CaseAutomatic Shutoff, Laser SightCE Marked
    YesAA211175K54000000
    E-40° F to 1,022° F/-40° C to 550° C0.1/0.1° C±1%12"0.3 to 0.9517"2"6 1/2"PlasticCarrying CaseAutomatic Shutoff, Laser SightCE Marked
    YesAA211175K51000000
    F-4° F to 1,202° F/-20° C to 650° C0.1/0.1° C±1%Not Rated0.1 to 10.57 3/8"2 3/16"4 9/16"PlasticCarrying CaseLaser SightCE Marked
    Yes9V19254T912000000
    G-58° F to 1,832° F/-50° C to 1,000° C0.1/0.1° C±1%Not Rated0.1 to 10.55 11/16"1 11/16"4 1/16"PlasticCarrying CaseLaser SightCE Marked
    Yes9V19254T911000000
    H-58° F to 3,992° F/-50° C to 2,200° C0.1/0.1° C±1%Not Rated0.1 to 10.18"2"6 1/8"PlasticCarrying CaseBargraph, Laser SightCE Marked
    Yes9V19254T915000000
     

    Thermal Imaging Cameras

    Image of Product. Front orientation. Thermal Cameras. Thermal Imaging Cameras, Style A.
    Image of Product. Front orientation. Thermal Cameras. Thermal Imaging Cameras, Style B.

    Style A

    Style B

    Detect hot spots, leaks, moisture problems, and construction defects invisible to the eye. These imaging guns translate thermal energy into a color image that indicates hotter areas as brighter and cooler areas as darker, so it’s easy to identify and diagnose problems on instrument panels, HVAC systems, and other equipment. To review footage at a later date, use them to take photos and videos. The lower a camera’s thermal sensitivity, the more precise heat differences it will detect for more detailed images. All are CE marked as meeting European standards for health, safety, and environmental protection. Some include a calibration certificate traceable to NIST stating they’ve passed a test for accuracy.
    Adjustable Emissivity—For Dark, Dull, Light, Shiny Surfaces
    Image of Product. Front orientation. Thermal Cameras. Thermal Imaging Cameras, Style A.

    Style A

    Style
    Temp. Range
    Thermal Sensitivity
    (NETD)
    Image
    Resolution
    Accuracy
    Emissivity
    Ht.
    Wd.
    Dp.
    Diag. Screen
    Size
    Housing
    Material
    Digital Display
    Type
    Certification
    Certificate Type
    Batteries
    Included
    Each
    A-4° F to 752° F/-20° C to 400° C60 mK160 × 120±2%0.1 to 19 9/16"3 11/16"5 1/2"3 1/2"PlasticLCDCE Marked
    Yes4006K7000000000
    A-4° F to 1,200° F/-20° C to 650° C<40 mK320 × 240±2%0.01 to 111"4 5/8"4 3/8"4"PlasticLCDCE Marked
    Yes4006K9100000000
    A-4° F to 1,200° F/-20° C to 650° C<40 mK320 × 240±2%0.01 to 111"4 5/8"4 3/8"4"PlasticLCDCE Marked
    Calibration Certificate Traceable to NISTYes4006K11100000000
    Fixed Emissivity—For Dark, Dull, Light, Shiny Surfaces
    Image of ProductInUse. Style B (Shown with Smartphone). Back orientation. Thermal Cameras. Thermal Imaging Cameras, Style B.
    Image of Product. Front orientation. Thermal Cameras. Thermal Imaging Cameras, Style B.

    Style B

    (Shown

    with

    Smartphone)

    Style B

    Style B—Style B cameras connect wirelessly to your smart phone, displaying the thermal imaging on your phone’s screen.
    Emissivity
    Style
    Temp. Range
    Thermal Sensitivity
    (NETD)
    Image
    Resolution
    Accuracy
    For Dark
    Surfaces
    For Dull
    Surfaces
    For Light
    Surfaces
    For Shiny
    Surfaces
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Certification
    Batteries
    Included
    Each
    B-4° F to 248° F/-20° C to 120° C70 mK80 × 60±5%0.950.80.60.35 7/8"1 1/2"1 3/8"Rubber
    CE Marked
    Yes4006K470000000
    B-4° F to 752° F/-20° C to 400° C70 mK160 × 120±5%0.950.80.60.35 7/8"1 1/2"1 3/8"Rubber
    CE Marked
    Yes4006K41000000

    Pocket Infrared Thermometers with Calibration Certificate

    Image of Product. Front orientation. Thermometers. Pocket Infrared Thermometers with Calibration Certificate, Style A.
    Image of Product. Front orientation. Thermometers. Pocket Infrared Thermometers with Calibration Certificate, Style B.
    Image of Product. Front orientation. Thermometers. Pocket Infrared Thermometers with Calibration Certificate, Style C.

    Style A

    Style B

    Style C

    To confirm the accuracy of noncontact temperature readings of dangerous and inaccessible surfaces, these thermometers come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy.
    Warning: These infrared thermometers are not intended for medical use. Use Noncontact Forehead Thermometers for medical use.
    Adjustable Emissivity—Thermometers with adjustable emissivity can be calibrated for more accurate readings of shiny surfaces than thermometers with fixed emissivity.
    Maximum Distance—Maximum working distance is the distance a one inch target can be reliably measured.
    Batteries
    Style
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    Max.
    Distance
    Emissivity
    Response
    Time, sec.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Thermometer Features
    Certification
    Included
    Size
    No.
    of
    Each
    For Dark Surfaces
     
    Fixed Emissivity
    A-7° F to 230° F/-22° C to 110° C0.1/0.1° C±2.7° F/±1.5° C1"0.9512 1/2"1 1/2"1/2"PlasticAutomatic ShutoffCE Marked
    YesCR203219203T75000000
     
    For Dark, Light, and Shiny Surfaces
     
    Fixed Emissivity
    B-27° F to 428° F/-33° C to 220° C0.1/0.1° C±1.8° F/±1.0° C1"0.9513 1/4"2 1/2"3/4"PlasticPocket ClipCE Marked
    Yes29233T4600000
     
    Adjustable Emissivity
    C-67° F to 482° F/-55° C to 250° C0.1/0.1° C±2° F/±1° C6"0.05 to 114"2"3/4"PlasticAutomatic Shutoff, Laser SightCE Marked
    YesCR203219233T4400000
    C-30° F to 430° F/-33° C to 220° C0.5° F/0.2° C±4° F/±2° C1"0.05 to 111 1/2"2 1/2"1/2"PlasticData Hold, Min./Max. MemoryCE Marked
    Yes19233T4700000
     

    Hazardous Location Infrared Thermometers

    Image of Product. Front orientation. Thermometers. Hazardous Location Infrared Thermometers.
    These thermometers are rated for environments where hazardous material is present. They measure the temperature of surfaces without making contact and are often used to locate and diagnose problems in electrical, heating, and ventilation systems. Since they have adjustable emissivity, you can calibrate them for accurate readings of shiny surfaces. Maximum working distance is the distance a one-inch target can be reliably measured.
    Warning: These infrared thermometers are not intended for medical use. Use Noncontact Forehead Thermometers for medical use.
    Maximum Distance—Maximum working distance is the distance a one inch target can be reliably measured.
    Hazardous Location Rating—Hazardous location environmental ratings indicate whether manufacturers have included safety features in products to facilitate their safe use in a hazardous environment. Before selecting a product for a hazardous location, ensure it is rated for your environment.
    Batteries
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    Max. Distance,
    ft.
    Emissivity
    Response
    Time, sec.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Includes
    Thermometer Features
    Hazardous Location Rating
    Certification
    Included
    Size
    No.
    of
    Each
    For Dark, Dull, Light, and Shiny Surfaces
     
    Adjustable Emissivity
    -40° F to 1,472° F/-40° C to 800° C0.1/0.1° C±1%300.1 to 10.57"2"6 1/2"PlasticCarrying CaseAutomatic Shutoff, Laser SightATEX II 2 G Ex Ia IIC T4 Gb
    Ex Ia IIC T4
    IEC Zone 1 Groups IIC, IIB, IIA
    IECEx Ex Ia IIC T4 Gb
    NEC Class I Divisions 1, 2 Groups A, B, C, D
    NEC Zone 1 Groups IIC, IIB, IIA
    AEx Ia IIC T4
    C-ETL Listed, CE Marked, ETL Listed
    YesAAA22970N11000000000
     

    Infrared Thermometers

    Image of Product. Front orientation. Thermometers. Infrared Thermometers, Style A.
    Image of Product. Front orientation. Thermometers. Infrared Thermometers, Style B.
    Image of Product. Front orientation. Thermometers. Infrared Thermometers, Style C.
    Image of Product. Front orientation. Thermometers. Infrared Thermometers, Style D.
    Image of Product. Front orientation. Thermometers. Infrared Thermometers, Style E.
    Image of Product. Front orientation. Thermometers. Infrared Thermometers, Style F.

    Style A

    Style B

    Style C

    Style D

    Style E

    Style F

    Measure the temperature of dangerous, hard-to-reach, and moving surfaces without risking electrical shock or contamination. These thermometers are often used to locate and diagnose problems in electrical, heating, and ventilation systems.
    Warning: These infrared thermometers are not intended for medical use. Use Noncontact Forehead Thermometers for medical use.
    Adjustable Emissivity—Thermometers have adjustable emissivity, so they can be calibrated for accurate readings of shiny surfaces.
    Maximum Distance—Maximum working distance is the distance a one inch target can be reliably measured.
    Batteries
    Style
    Temp. Range
    Resolution/Temp.
    Resolution
    Accuracy
    Max.
    Distance
    Emissivity
    Response
    Time, sec.
    Ht.
    Wd.
    Dp.
    Housing
    Material
    Includes
    Thermometer Features
    Certification
    Included
    Size
    No.
    of
    Each
    For Dark, Light, and Shiny Surfaces
     
    Adjustable Emissivity
    A-58° F to 1,200° F/-50° C to 650° C0.1/0.1° C±1%12"0.1 to 116 3/8"1 5/8"3 1/4"PlasticCarrying CaseAutomatic Shutoff, Laser SightCE Marked
    Yes9V19254T610000000
    B-58° F to 1,832° F/-50° C to 1,000° C0.1/0.1° C±1%30"0.1 to 115 3/4"1 5/8"4"PlasticCarrying CaseAutomatic Shutoff, Laser SightCE Marked
    Yes9V19254T111000000
    C-40° F to 1,022° F/-40° C to 550° C0.1/0.1° C±1%12"0.3 to 0.9517"2"6 1/2"PlasticCarrying CaseAutomatic Shutoff, Laser SightCE Marked
    YesAA211175K91000000
    D-40° F to 1,202° F/-40° C to 650° C0.1/0.1° C±1%30"0.1 to 117"2"6 1/2"PlasticCarrying CaseAutomatic Shutoff, Laser SightCE Marked
    YesAA211175K93000000
    D-40° F to 1,472° F/-40° C to 800° C0.1/0.1° C±1%50"0.1 to 117"2"6 1/2"PlasticCarrying CaseAutomatic Shutoff, Laser SightCE Marked
    YesAA211175K94000000
    E-22° F to 932° F/-30° C to 500° C0.1/0.1° C±1.5%12"0.1 to 116 7/8"3"3 3/8"PlasticAutomatic Shutoff, Laser SightCE Marked
    YesAA13734K62000000
    F-4° F to 1,202° F/-20° C to 650° C0.1/0.1° C±1%12"0.1 to 117 7/16"2 3/16"4 5/8"PlasticCarrying CaseAutomatic Shutoff, Laser Sight, WaterproofCE Marked
    Yes9V19254T112000000
     
    back to top