McMaster-Carr logo
    Filter by
    Power Source
    System of Measurement
    Voltage
    Industrial Info Snippet
    Discharge Pipe Size
    Industrial Info Compare
    Maximum Pressure
    Diaphragm Material
    Priming Type
    Intake Pipe Size
    Industrial Info Compare
    For Drum Opening Pipe Size
    Industrial Info Compare
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    DFARS Specialty Metals
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    137 Products

    High-Accuracy Metering Diaphragm Pumps for Chemicals

    Image of Product. Front orientation. Diaphragm Pumps.
    These diaphragm pumps meter a consistent amount of liquid within ±2% of the maximum flow. Often used to pump water-treatment chemicals, cleaning fluids, and electropolishing solutions, they have an adjustment dial that alters flow rate in 2% increments of the maximum flow. Pumps are self-priming and create suction to draw liquid upward. They can run dry but are not for use with solids.
    Pump Repair Kits—Repair kits include a pump head assembly, a diaphragm, valves, and seals.
    Diaphragm Pumps
    Pump Repair Kits
    Replacement
    Drain Valves
    Replacement
    Flow-Adjustment Valves
    For
    Tube
    Overall
    Flow Rate,
    gal/day
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    ID
    OD
    Lg.
    Wd.
    Ht.
    Features
    Each
    Each
    Each
    Each
    120V AC, Single Phase
     
    Plug In
    0.03 to 33001,00035 to 15011/6411/4"3/8"10 7/8"5 1/2"10 3/8"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K93000000082695K39000000082695K9400000082695K81000000
    0.05 to 52501,00035 to 15011/6411/4"3/8"10 7/8"5 1/2"10 3/8"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K4500000082695K3900000082695K940000082695K8100000
    0.12 to 122501,00035 to 15011/6411/4"3/8"11 1/4"5 1/2"10 5/8"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K5200000082695K3200000082695K820000082695K8100000
    0.22 to 221501,00035 to 15011/6411/4"3/8"11 1/4"5 1/2"10 5/8"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K5300000082695K3300000082695K820000082695K8100000
    0.24 to 241001,00035 to 15011/6411/4"3/8"10 3/4"5 1/2"10 5/8"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K5400000082695K3300000082695K820000082695K8100000
    0.42 to 421501,00035 to 15011/6411/4"3/8"11 3/4"5 1/2"10 5/8"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K550000000082695K33000000———0———0
    0.44 to 441001,00035 to 15011/6411/4"3/8"11 1/4"5 1/2"10 5/8"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K560000000082695K33000000———0———0
    0.94 to 941001,00035 to 15011/6413/8"1/2"11 3/4"5 1/2"11"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K570000000082695K3500000082695K710000082695K4100000
    1.2 to 1201001,00035 to 15011/6413/8"1/2"12"6 1/4"11 3/8"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K580000000082695K3600000082695K710000082695K4100000
    1.92 to 192501,00035 to 15011/6413/8"1/2"11 1/4"6 1/8"11 3/4"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K590000000082695K3700000082695K710000082695K4100000
    2.4 to 240351,00035 to 15011/6413/8"1/2"12"6 1/8"11 3/4"Backflow-Prevention Valve, Bleed Valve, Foot Valve/Strainer82695K610000000082695K3700000082695K710000082695K4100000
    6 to 600301,00035 to 15011/6411/2"3/4"11 3/8"6 1/8"11"Backflow-Prevention Valve, Foot Valve/Strainer82695K620000000082695K3800000082695K42000000———0
     
    Replacements for Diaphragm Pumps

    Compact Drum Pumps for Water and Chemicals

    Image of Product. Front orientation. Drum Pumps. Compact Drum Pumps for Water and Chemicals, Style A.

    Style A

    Designed to move low volumes of caustic liquids in confined areas, these pumps have a thin intake tube and a small handle. They are often used to pump cleaning fluids, acid-washing solutions, and bleach.
    Style A—Style A pumps have a selectable flow rate, so you can adjust flow for different dispensing applications.
    Temp.
    Intake
    Style
    Flow Rate, fl oz/stroke
    For Container
    Size, gal.
    Max.
    Viscosity
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Spout
    Type
    Drum Pump
    Type
    Each
    A2, 4, 6, 85Not RatedNot Rated1253/4 NPT5/8"18 1/4"Spout EndFixedPlunger4368K15000000
    A2, 4, 6, 815 to 55Not RatedNot Rated1253/4 NPT, 2 NPTTwo Drum Connectors5/8"33"Spout EndFixedPlunger4368K1300000
    A4, 8, 12, 1615 to 55Not RatedNot Rated1253/4 NPT, 2 NPTTwo Drum Connectors5/8"33"Spout EndFixedPlunger4368K1400000
     

    316 Stainless Steel Air-Powered Double Diaphragm Pumps for Chemicals, Fuel, and Flammable Liquids

    With a 316 stainless steel housing and a PTFE diaphragm, these pumps resist a variety of acids, alkalies, and flammable liquids such as phosphoric acid, acetone, and methyl ethyl ketone (MEK). They're designed for moving large volumes of thick sludges and slurries in demanding environments. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All are submersible and can run dry.
    Threaded Bottom Intake and Threaded Top Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. 316 Stainless Steel Air-Powered Double Diaphragm Pumps for Chemicals, Fuel, and Flammable Liquids, Threaded Bottom Intake and Threaded Top Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Max. Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 80 ft.
    of Head
    @ 120 ft.
    of Head
    @ 160 ft.
    of Head
    Max. Solids
    Dia.
    Max. Viscosity,
    cP
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge Size
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    289 ft. Maximum Feet of Head—125 psi Maximum Discharge Pressure
    15121071/8"10,000201/4 Female NPT1/2 Female NPT1/2 Female NPT9"10"10"41655K270000000009948K5800000003781K520000000
    453830191/4"20,000401/2 Female NPT1 Female NPT1 Female NPT13"10"13"41655K28000000003781K680000003781K47000000
    1067762451/4"30,000503/4 Female NPT1 1/2 Female NPT1 1/2 Female NPT15"17"22"41655K29000000003781K630000003781K4400000000
    15010476531/4"40,0001003/4 Female NPT2 Female NPT2 Female NPT15"17"26"41655K31000000003781K630000003781K1900000000
    235174127903/8"50,0001403/4 Female NPT3 Female NPT3 Female NPT17"20"32"41655K320000000003781K630000003781K3900000000
     

    High-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. High-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals.
    Designed to move 40 gallons of liquid per minute, these pumps quickly empty drum contents. They're often used with lubricating oil as well as with chemicals such as detergents and etching and cleaning solutions.
    Temp.,
    ° F
    Intake
    Discharge
    Electrical
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Discharge
    Pressure, psi
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Connection
    No. of
    Blades
    Each
    120V AC—Single Phase—Plug In
    403035500351601/25.72 NPTDrum Connector2"27"Tube End1"1 5/16"60"PVC
    Straight Blade36800K12000000000
    405535500351601/25.72 NPTDrum Connector2"40"Tube End1"1 5/16"60"PVC
    Straight Blade36800K1400000000
    405535500351601/25.72 NPTDrum Connector2"48"Tube End1"1 5/16"60"PVC
    Straight Blade36800K1800000000
     
    Pump Replacement Parts

    Siphon Drum Pumps

    Image of Product. Front orientation. Drum Pumps. Siphon Drum Pumps, Style B.

    Style B

    Since these pumps use suction to draw liquid out of your container, they continue dispensing once you get them started. They're often used with coolant and water.
    5 gpm to 7 gpm Flow Rate—Adjust pumps with a 5-7 gpm flow rate for different dispensing applications.
    Temp.
    Intake
    Discharge
    Style
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Drum Pump
    Type
    Each
    B5 to 75650Not Rated1402 NPS, 70 mmDrum Connector1 1/2"16"Tube End1"1 1/4"60"PVC
    Siphon4270K24000000
    B5 to 75 to 6650Not Rated1402 NPSDrum Connector1 1/2"16"Tube End1"1 1/4"60"PVC
    Siphon4270K2500000
    B5 to 715650Not Rated1402 NPSDrum Connector1 1/2"24"Tube End1"1 1/4"60"PVC
    Siphon4270K2600000
     
    Connectors

    316 Stainless Steel Air-Powered Double Diaphragm Pumps for Oil, Chemicals, Fuel, and Large Solids

    With a 316 stainless steel housing and a fluoroelastomer diaphragm, these pumps resist a variety of harsh acids and alkalies, such as phosphoric acid, nitric acid, and sulfuric acid. They have large internal pathways and check valves with flaps to accommodate thick sewage, abrasive slurries, and industrial waste with large solids that would damage standard air-powered double diaphragm pumps. All are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. Pumps are submersible and can run dry.
    Threaded Top Intake and Threaded Bottom Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. 316 Stainless Steel Air-Powered Double Diaphragm Pumps for Oil, Chemicals, Fuel, and Large Solids, Threaded Top Intake and Threaded Bottom Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Max. Flow Rate, gpm
    Overall
    Max. Flow
    Rate, gpm
    @ 80 ft.
    of Head
    @ 120 ft.
    of Head
    @ 160 ft.
    of Head
    Max. Solids
    Dia.
    Max.
    Viscosity
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge
    Size
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    289 ft. Maximum Feet of Head—125 psi Maximum Discharge Pressure
    704735201"Not Rated501/2 Female NPT1 Female NPT1 Female NPT11"17"16"2785K630000000003781K5800000008090K42000000000
     

    Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals, Style A.
    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals, Style B.

    Style A

    Style B

    Alter the flow rate for versatile dispensing. These pumps do not include a drum connector.
    Tube-End Discharge
    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals, Style A.

    Style A

    Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Electrical
    Style
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Connection
    No. of
    Blades
    Each
    Each
    120V AC—Single Phase—Plug In—With Thermal Overload Protection
    A0 to 18.5930300151201/41.532 mmWall Bracket1 1/4"27"3/4"1"60"Straight Blade242895K81000000042895K940000000
    A0 to 18.5955300151201/41.532 mmWall Bracket1 1/4"39"3/4"1"60"Straight Blade242895K8200000042895K95000000
     
    Pump Replacement Parts
    Pump Body
    Image of Product. Front orientation. Drum Pumps. Adjustable-Flow Electric Drum Pumps for Water, Oil, Coolants, and Chemicals, Style B.

    Style B

    Pumps
    Pump Repair Kits
    Connectors
    Temp.
    Intake
    Discharge
    (Pump Body)
    Electrical
    Style
    Flow Rate,
    gpm
    Discharge
    Pressure, psi
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.,
    ° F
    Power,
    hp
    Current,
    amp
    For Drum Opening
    Size
    Tube
    OD
    Tube
    Lg.
    Connection
    For Tube
    ID
    Connection
    No. of
    Blades
    Each
    Each
    Each
    120V AC—Single Phase—Plug In—With Thermal Overload Protection
    B0 to 3516551,500Not Rated13018.52"1 5/8"39"Barbed
    1"Straight Blade32850K350000000002850K7100000002850K62000000
    B0 to 3516551,500Not Rated13018.52"1 5/8"47"Barbed
    1"Straight Blade32850K36000000002850K710000002850K6200000
    B0 to 3516551,500Not Rated17518.52"1 5/8"39"Barbed
    1"Straight Blade32850K41000000002850K720000002850K6200000
     
    Pump Replacement Parts

    Drum Pumps for Water and Chemicals

    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style F.

    Style F

    Push the plunger to pump water, cleaners, and chemicals.
    Style F
    Image of Product. Front orientation. Drum Pumps. Drum Pumps for Water and Chemicals, Style F.
    Style F are rated for liquids up to 2,500 centipoise.
    Pumps
    Connectors
    Replacement
    Connectors
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    fl oz/stroke
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    For Drum Opening
    Size
    Includes
    Tube
    OD
    Tube
    Lg.
    Location
    Tube
    ID
    Tube
    OD
    Tube
    Lg.
    Tube
    Material
    Each
    Connection
    Each
    Pipe
    Size
    Each
    Viton® Fluoroelastomer Piston
    28552,500351202 NPTDrum Connector1 1/2"38"Tube End1 1/4"1 1/2"36"Polyethylene9918K7500000002 5/8"-5 Buttress9918K450000002 NPT9918K43000000
    28552,500351202 NPTDrum Connector1 1/2"38"Tube End1 1/4"1 1/2"72"Polyethylene9918K760000002 5/8"-5 Buttress9918K45000002 NPT9918K4300000
    28552,500351202"Drum Connector1 1/2"38"Tube End1 1/4"1 1/2"36"Polyethylene9918K120000002 5/8"-5 Buttress9918K45000002 NPT9918K4300000
    28552,500351202"Drum Connector1 1/2"38"Tube End1 1/4"1 1/2"72"Polyethylene9918K1150000002 5/8"-5 Buttress9918K45000002 NPT9918K4300000
     

    Precision Flow-Adjustment Valves with Push-to-Connect Fittings for Chemicals

    Insert tubing into the fittings on these valves—no heat, solder, or flux required. With a fluoroelastomer seal and a PVDF body, they can withstand aggressive and corrosive solutions in chemical-processing applications. Turn the handle to adjust flow in small increments for metering, sampling, and other applications requiring fine flow control. Threads and a hex nut below the handle allow you to install these valves in instrument panels. They have a nut that can be tightened to compress the packing if it leaks.
    PVDF Body
    Image of Product. Front orientation. Flow-Adjustment Valves. Precision Flow-Adjustment Valves with Push-to-Connect Fittings for Chemicals.
    Overall
    For Tube
    ID
    For Tube
    OD
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Ht.
    Lg.
    Seal Material
    Panel Cutout
    Dia.
    Packing
    Material
    Needle
    Material
    End-to-End
    Lg.
    For Use With
    Valve
    Type
    Each
    Push to Connect × Push to Connect
    1/8" 1/4" 0.3125 psi @ 140° F2 5/8"2 11/16"Fluoroelastomer
    7/8"PTFE
    PVDF2 11/16"Water, Oil, Air, Argon, Butane, Carbon Dioxide, Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Gasoline, Helium, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Krypton, Methanol (Methyl Alcohol), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oxygen, Phosphoric Acid, Propane, Salt Water, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Sulfuric Acid, Toluene (Methylbenzene), Xenon, XyleneNeedle3112N11000000
    1/4" 3/8" 0.4125 psi @ 140° F2 5/8"2 11/16"Fluoroelastomer
    7/8"PTFE
    PVDF2 11/16"Water, Oil, Air, Argon, Butane, Carbon Dioxide, Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Gasoline, Helium, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Krypton, Methanol (Methyl Alcohol), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oxygen, Phosphoric Acid, Propane, Salt Water, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Sulfuric Acid, Toluene (Methylbenzene), Xenon, XyleneNeedle3112N1200000
     

    PTFE Air-Powered Double Diaphragm Pumps for Harsh Chemicals

    With all PTFE wetted parts, these pumps offer the best chemical resistance of all our air-powered double diaphragm pumps and can handle solvents and petroleum-based fluids that PVDF pumps can’t. Pumps are self-priming, which means they create a suction force to draw liquid upward to fill the pump chamber. All can run dry.
    Threaded Side Intake and Threaded Side Discharge
    Image of Product. Front orientation. Double Diaphragm Pumps. PTFE Air-Powered Double Diaphragm Pumps for Harsh Chemicals, Threaded Side Intake and Threaded Side Discharge.
    Air Motor Pump Repair Kits—Air-motor repair kits include seals, O-rings, gaskets, retaining rings, and an air valve spool.
    Fluid Side Pump Repair Kits—Fluid-side repair kits include diaphragms, check valve balls, and seals.
    Double Diaphragm Pumps
    Air Motor Pump
    Repair Kits
    Fluid Side Pump
    Repair Kits
    Overall
    Max. Flow
    Rate, gpm
    Max. Solids
    Dia.
    Air Consumption,
    ft³/min
    Air Connection
    Size
    Intake Size
    Discharge
    Size
    Lg.
    Wd.
    Ht.
    Each
    Each
    Each
    231 ft. Maximum Feet of Head—100 psi Maximum Discharge Pressure
    2.50.06"4.81/8 Female NPT1/4 Female NPT1/4 Female NPT3 3/8"5 1/2"6 1/2"2925N10000000002666N2800000002666N210000000
    6.70.08"9.31/8 Female NPT3/8 Female NPT3/8 Female NPT3 1/2"5 7/8"7 5/8"2925N2000000002666N290000002666N22000000
    160.16"291/4 Female NPT1/2 Female NPT1/2 Female NPT6"9 3/16"8"2925N3000000002666N310000002666N2300000000
    390.24"461/4 Female NPT1 Female NPT1 Female NPT8"10 7/8"10 3/8"2925N4000000002666N320000002666N2400000000
     

    Threaded Precision Flow-Adjustment Valves for Chemicals

    To withstand aggressive and corrosive solutions in chemical-processing applications, these valves have a fluoroelastomer seal and a plastic body. Turn the handle to adjust flow in small increments for metering, sampling, and other applications requiring fine flow control.
    White PVDF Body
    Image of Product. Front orientation. Flow-Adjustment Valves. Threaded Precision Flow-Adjustment Valves for Chemicals, White, Straight.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Pipe
    Size
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Max. Temp.,
    ° F
    Panel Cutout
    Dia.
    Seat
    Material
    End-to-End
    Lg.
    Valve
    Type
    For Use With
    Seal Material
    Needle
    Material
    Each
    NPT Female × NPT Female
    1/4 0.64150 psi @ 70° F3001 5/16"PTFE2 1/2"NeedleWater, Oil, Food, Beverage, Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Fuel Oil, Gasoline, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Methanol (Methyl Alcohol), Mineral Spirits, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Sulfuric AcidFluoroelastomer
    Polypropylene2547N110000000
    3/8 0.72150 psi @ 70° F3001 5/16"PTFE2 1/2"NeedleWater, Oil, Food, Beverage, Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Fuel Oil, Gasoline, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Methanol (Methyl Alcohol), Mineral Spirits, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Sulfuric AcidFluoroelastomer
    Polypropylene2547N12000000
    1/2 0.79150 psi @ 70° F3001 5/16"PTFE2 1/2"NeedleWater, Oil, Food, Beverage, Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Fuel Oil, Gasoline, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Methanol (Methyl Alcohol), Mineral Spirits, Phosphoric Acid, Salt Water, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Sulfuric AcidFluoroelastomer
    Polypropylene2547N13000000
     

    High-Flow Peristaltic Pumps for Chemicals

    Image of Product. Front orientation. Peristaltic Pumps. High-Flow Peristaltic Pumps for Chemicals.
    For high-volume chemical sampling and draining, these pumps have a powerful motor that enables them to move 2,592 gallons of liquid per day. They're commonly used with ammonia, acid-washing solutions, and cleaning fluids. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are self-priming and create a suction force to draw liquid upward. Mount up to 15 feet above your liquid source. They can run dry. Do not use with solids.
    Intake
    Discharge
    Overall
    Flow Rate,
    gal/day
    Max. Pressure,
    psi
    Max. Viscosity,
    cP
    Temp. Range,
    ° F
    Power,
    hp
    Current,
    amp
    For Tube
    ID
    Connection
    For Tube
    ID
    Connection
    Lg.
    Wd.
    Ht.
    Includes
    Each
    120V AC, Single Phase
     
    Plug In
    2,592201,00035 to 1601/43.11/2"Barbed
    1/2"Barbed
    10"5 1/2"10"10 5/8" Lg. of 1/2" ID Tygon Tubing (Shore A61)4306K640000000
     
    Replacements for Peristaltic Pumps

    PVDF Long-Life Air-Powered Drum Pumps for Chemicals

    Image of Product. Front orientation. Drum Pumps. PVDF Long-Life Air-Powered Drum Pumps for Chemicals.
    A chemical- and impact-resistant PVDF housing stands up to aggressive chemicals such as methyl ethyl ketone (MEK) and xylene. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/lubricator to ensure efficiency and reduce wear on the pump.
    Pump Repair Kits—Repair kits include O-rings, valves, and diaphragms.
    Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Connection
    Pipe Size
    Tube
    Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    Each
     
    PTFE Diaphragm
    13553,00040210100122 NPTDrum Connector1/4 Female NPTThreaded1/2 Female NPT36"Pump BodyThreaded1/2 Female NPT2534K540000000008281K1110000000
     

    Precision Flow-Adjustment Valves with Barbed Fittings for Chemicals

    Image of Product. Front orientation. Flow-Adjustment Valves. Precision Flow-Adjustment Valves with Barbed Fittings for Chemicals.
    Barbs grip onto tubing, providing a secure hold. To withstand aggressive and corrosive solutions in chemical-processing applications, these valves have a PTFE seal and a PVDF body. Turn the handle to adjust flow in small increments for metering, sampling, and other applications requiring fine flow control. Threads and a hex nut below the handle allow you to install these valves in instrument panels. They have a nut that can be tightened to compress the packing if it leaks.
    For Tube
    ID
    For Tube
    OD
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Max. Temp.,
    ° F
    Panel Cutout
    Dia.
    End-to-End
    Lg.
    Valve
    Type
    For Use With
    Seal
    Material
    Packing
    Material
    Needle
    Material
    Each
    Black PVDF Body
     
    Barbed × Barbed
    1/4" 3/8" 0.3125 psi @ 140° F1407/8"3 5/16"NeedleWater, Oil, Air, Argon, Butane, Carbon Dioxide, Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Gasoline, Helium, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Krypton, Methanol (Methyl Alcohol), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oxygen, Phosphoric Acid, Propane, Salt Water, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Sulfuric Acid, Toluene (Methylbenzene), Xenon, XylenePTFE
    PTFE
    PVDF3010N11000000
    3/8" 1/2" 0.3125 psi @ 140° F1407/8"3 5/16"NeedleWater, Oil, Air, Argon, Butane, Carbon Dioxide, Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Gasoline, Helium, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Krypton, Methanol (Methyl Alcohol), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oxygen, Phosphoric Acid, Propane, Salt Water, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Sulfuric Acid, Toluene (Methylbenzene), Xenon, XylenePTFE
    PTFE
    PVDF3010N1200000
    1/2"5/8" 0.4125 psi @ 140° F1407/8"3 5/16"NeedleWater, Oil, Air, Argon, Butane, Carbon Dioxide, Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Gasoline, Helium, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Krypton, Methanol (Methyl Alcohol), Mineral Spirits, Natural Gas, Neon, Nitric Acid, Nitrogen, Oxygen, Phosphoric Acid, Propane, Salt Water, Soap Solutions, Sodium Hydroxide (Caustic Soda), Sodium Hypochlorite (Bleach), Sulfuric Acid, Toluene (Methylbenzene), Xenon, XylenePTFE
    PTFE
    PVDF3010N1300000
     

    Air-Powered Drum Pumps with Hose and Filter/Lubricator for Water, Oil, Coolants, and Chemicals

    Image of Product. Front orientation. Contains Annotated. Drum Pumps. Air-Powered Drum Pumps with Hose and Filter/Lubricator for Water, Oil, Coolants, and Chemicals.
    A filter/lubricator ensures efficiency and reduces wear on the pump. They have a chemically resistant seal for use with hydraulic oil and motor oil in addition to acidic and alkaline liquids such as ammonia and etching and cleaning solutions. Pumps have a nonsparking motor for use in applications where electricity is unavailable or dangerous.
    Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Tube
    OD
    Tube
    Lg.
    Discharge
    Location
    Tube
    ID
    Tube Lg.,
    ft.
    Tube
    Material
    Features
    Each
    Each
    16552,0003515080 to 100322 NPTDrum Connector1/4 Female NPT1 5/8"40"Tube End1"5PVC
    15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler8243K310000000008243K620000000
    22553303516080 to 100322 NPTDrum Connector1/4 Female NPT2"40"Tube End1"5PVC
    15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler4296K4100000000———0
    22553303516080 to 100322 NPTDrum Connector1/4 Female NPT2"48"Tube End1"5PVC
    15-ft. Air Hose Assembly, Air Filter/Lubricator, Ball Valve, Muffler4296K4800000000———0
     
    Couplings

    Polypropylene Long-Life Air-Powered Drum Pumps for Chemicals

    Image of Product. Front orientation. Drum Pumps. Polypropylene Long-Life Air-Powered Drum Pumps for Chemicals.
    The polypropylene housing provides good resistance to caustics such as ammonia, electropolishing solutions, and detergents and cleaning fluids. Also known as diaphragm pumps, they have few moving parts that can fail for a long service life. Install an air line filter/regulator to ensure efficiency and reduce wear on the pump.
    PTFE Diaphragm—Choose a pump with a PTFE diaphragm for superior resistance to a wider variety of concentrated chemicals than Santoprene.
    Pump Repair Kits—Repair kits include components such as O-rings, valves, balls, and diaphragms.
    Pumps
    Pump Repair Kits
    Temp.,
    ° F
    Intake
    Discharge
    Flow Rate,
    gpm
    For Container
    Size, gal.
    Max. Viscosity,
    cP
    Min.
    Max.
    Air Pressure,
    psi
    Air Consumption,
    ft³/min
    For Drum Opening
    Size
    Includes
    Air
    Connection
    Connection
    Pipe Size
    Tube
    Lg.
    Discharge
    Location
    Connection
    Pipe Size
    Each
    Each
     
    Santoprene Diaphragm
    13553,00030180100122 NPTDrum Connector1/4 Female NPTThreaded1/2 Female NPT36"Pump BodyThreaded1/2 Female NPT2534K1800000008281K460000000
    31558,00030180100402 NPTDrum Connector1/4 Female NPTThreaded3/4 Female NPT36"Pump BodyThreaded3/4 Female NPT8281K55000000008281K47000000
     
    PTFE Diaphragm
    13553,00040180100122 NPTDrum Connector1/4 Female NPTThreaded1/2 Female NPT36"Pump BodyThreaded1/2 Female NPT8281K520000008281K111000000
    28558,00040180100402 NPTDrum Connector1/4 Female NPTThreaded3/4 Female NPT36"Pump BodyThreaded3/4 Female NPT8281K57000000008281K48000000
     
    back to top