About Actuated On/Off Valves
More
About On/Off Valves
More
On/Off Valves with Luer Lock Fittings
With just a half turn or a light push, these valves connect to luer lock fittings on your line. Their universal connection size fits any luer lock plug or socket.
Polycarbonate valves are lighter in weight than metal valves, but they aren’t as durable.
Connections without a locking ring are quicker to install and remove than those with a locking ring. Also known as luer slip connections, all they need is a light push. Add a snap-on ring (sold separately) to lock your connection in place and color code your line.
Connections with a locking ring are more secure than those without a locking ring, so they’re better for high pressures. Give the ring a half turn to lock them in place. You can’t remove the locking ring.


Lock Male without
Locking Ring

Locking Ring × Luer Lock
Male without Locking Ring


Locking Ring × Luer Lock
Male without Locking Ring

Ring × Luer Lock
Male with Locking Ring
- Valve Type: Stop Cock
- For Use With: Air, Argon, Helium, Krypton, Neon, Oil, Water, Xenon
| Max. Pressure | End-to-End Lg. | Each | |
Luer Lock Female × Luer Lock Female | |||
|---|---|---|---|
| 50 psi @ 70° F | 1 3/16" | 7033T26 | 00000 |
Luer Lock Female × Luer Lock Male without Locking Ring | |||
| 50 psi @ 70° F | 1 3/8" | 7033T25 | 0000 |
Luer Lock Male without Locking Ring × Luer Lock Male without Locking Ring | |||
| 50 psi @ 70° F | 1 1/2" | 7033T23 | 0000 |
Luer Lock Male with Locking Ring × Luer Lock Female | |||
| 50 psi @ 70° F | 1 3/8" | 7033T24 | 0000 |
Luer Lock Male with Locking Ring × Luer Lock Male without Locking Ring | |||
| 50 psi @ 70° F | 1 1/2" | 7033T22 | 0000 |
Luer Lock Male with Locking Ring × Luer Lock Male with Locking Ring | |||
| 50 psi @ 70° F | 1 1/2" | 7033T21 | 0000 |
Compact Solenoid On/Off Valves with Push-to-Connect Fittings

- For Use With: Water, Air, Argon, Helium, Neon, Xenon, Krypton
- Seal Material: Buna-N Rubber
- Specifications Met: CSA Certified
Insert tubing into the fittings on these valves—no heat, solder, or flux required. They operate on electricity to automatically start and stop flow.
Valves are normally closed unless actuated. They don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
| For Tube OD | Gender | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Quick-Disconnect Tab Wd. | Each | |
Polycarbonate Plastic Body with Quick-Disconnect Terminals | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
Normally Closed—24V DC | ||||||||||
| 1/4" | Female | 0.31 | 80 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2" | 3" | 1/4" | 5489T433 | 0000000 |
| 1/4" | Female | 0.37 | 40 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2" | 3" | 1/4" | 5489T453 | 000000 |
| 3/8" | Female | 1 | 5 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2 3/8" | 3" | 1/4" | 5489T493 | 000000 |
Normally Closed—120V AC | ||||||||||
| 1/4" | Female | 0.31 | 80 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2" | 3" | 1/4" | 5489T431 | 000000 |
| 1/4" | Female | 0.37 | 40 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2" | 3" | 1/4" | 5489T451 | 000000 |
| 3/8" | Female | 1 | 5 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2 3/8" | 3" | 1/4" | 5489T491 | 000000 |
Food Industry Solenoid On/Off Valves with Push-to-Connect Fittings

- For Use With: Food, Beverage
- Seal Material: EPR Rubber
- Specifications Met: CSA Certified, NSF/ANSI 169
Insert tubing into the fittings on these valves—no heat, solder, or flux required. Valves meet NSF/ANSI 169 for use with food equipment. They operate on electricity to automatically start and stop flow.
All are normally closed unless actuated. Valves don’t require a minimum pressure drop between the inlet and outlet for operation. The actuator is directly mounted to the valve body to minimize movement and reduce wear.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
| For Tube OD | Gender | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Quick-Disconnect Tab Wd. | Each | |
Polycarbonate Plastic Body with Quick-Disconnect Terminals | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
Normally Closed—24V DC | ||||||||||
| 1/4" | Female | 0.3 | 80 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2" | 3" | 1/4" | 5489T633 | 0000000 |
| 1/4" | Female | 0.4 | 40 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2" | 3" | 1/4" | 5489T653 | 000000 |
Normally Closed—120V AC | ||||||||||
| 1/4" | Female | 0.3 | 80 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2" | 3" | 1/4" | 5489T631 | 000000 |
| 1/4" | Female | 0.4 | 40 psi @ 70° F | Zero Pressure Drop | -10° to 100° | 2" | 3" | 1/4" | 5489T651 | 000000 |