About Actuated On/Off Valves
More
Severe-Duty Air-Driven On/Off Valves for Chemicals

- Valve Type: Diaphragm
- For Use With:
Pipe Size 1/4: Oil, Air, Propane, Butane, Acetone, Ammonia, Carbon Dioxide, Chlorine, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Fuel Oil, Gasoline, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Methanol, Methyl Ethyl Ketone, Mineral Spirits, Nitric Acid, Nitrogen, Oxygen, Sodium Hypochlorite, Sulfuric Acid, Toluene, Citric Acid, Phosphoric Acid, Sodium Hydroxide
Pipe Size 1/2: Water, Oil, Air, Natural Gas, Propane, Butane, Acetone, Ammonia, Carbon Dioxide, Chlorine, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Fuel Oil, Gasoline, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Methanol, Methyl Ethyl Ketone, Mineral Spirits, Nitric Acid, Nitrogen, Oxygen, Salt Water, Soap Solutions, Sodium Hypochlorite, Steam, Sulfuric Acid, Toluene, Citric Acid, Phosphoric Acid, Sodium Hydroxide
Pipe Size 3/4: Water, Oil, Air, Natural Gas, Propane, Butane, Acetone, Ammonia, Carbon Dioxide, Chlorine, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Fuel Oil, Gasoline, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Methanol, Methyl Ethyl Ketone, Mineral Spirits, Nitric Acid, Nitrogen, Oxygen, Salt Water, Soap Solutions, Sodium Hypochlorite, Steam, Sulfuric Acid, Toluene, Citric Acid, Phosphoric Acid, Sodium Hydroxide - Seal Material : PTFE Plastic
- Seat Material: PTFE Plastic
- Actuator Housing Material: Plastic
Also known as diaphragm valves, these have a PTFE body and seals that stand up to harsh acidic solutions. The diaphragm can handle dirty liquid, slurries, and abrasive media without damage. All valves operate on compressed air to automatically start and stop flow. You must control the air to the actuator using either an electric pilot valve (not included) or a manual on/off valve (not included). These valves don’t require a minimum pressure drop between the inlet and outlet for operation.
All have a single-acting actuator that only requires air pressure to open the valve; they automatically spring closed when the air turns off. The actuator is directly mounted to the valve body to minimize movement and reduce wear. Valves are normally closed unless actuated.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Air | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pipe Size | Gender | Thread Type | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Connection | Pressure Range, psi | Mounting Stud Screw Size | No. of Mounting Studs | Fasteners Included | Each | |
PTFE Plastic Body | |||||||||||||||
Single Acting: Air-to-Open, Spring Return (Normally Closed) | |||||||||||||||
| 1/4 | Female | NPT | 0.7 | 60 psi @ 140° F | Zero Pressure Drop | 35° to 175° | 2 1/8" | 2 7/8" | 1/8 NPT Female | 40 to 60 | __ | 2 | No | 00000000 | 0000000 |
| 1/2 | Female | NPT | 2.8 | 60 psi @ 140° F | Zero Pressure Drop | 35° to 210° | 2 3/4" | 3 3/8" | 1/8 NPT Female | 60 to 80 | 1/4" | 2 | No | 00000000 | 000000 |
| 120V AC Pilot Valve | 00000000 | Each | 0000000 |