McMaster-Carr logo
    Filter by
    Pipe Size
    Industrial Info Compare
    Actuation
    Fitting Connection
    Body Material
    Ball Material
    Valve Function
    Port Type
    Bolt Circle Diameter
    Pressure Class
    Industrial Info Snippet
    Maximum Pressure @ Temperature
    Maximum Temperature
    Number of Bolt Holes
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Industrial Info Snippet
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    8 Products
    About Actuated On/Off Valves
    industrial info icon

    Choose the right automatic on/off valve based on power source, pressure, and flow rate.

    High-Flow Flanged Motor-Actuated On/Off Valves

    Their ball-valve design allows these valves to handle at least three times the flow of standard flanged valves. All operate on electricity to automatically start and stop flow. They don’t require a minimum pressure drop between the inlet and outlet for operation. All are fail in place; upon loss of power, the valve will remain in its current position. Valves are full port, so they do not restrict flow.
    The actuator is secured to the valve body with a bracket for easy disassembly, maintenance, and repair. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. Two single pole, double throw (SPDT) auxiliary switches allow you to connect these valves to temperature-monitoring equipment, programmable logic controllers, or conveyor sirens. The internal heater automatically turns on when the valve is actuated to prevent motor damage caused by condensation buildup. A manual override allows you to operate the valve during power outages.
    Carbon Steel Body with Screw-Terminal Wire Connection
    Image of Product. Front orientation. Contains Annotated. Motor-Actuated On/Off Valves. High-Flow Flanged Motor-Actuated On/Off Valves.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Bolts
    Overall
    Pipe
    Size
    Fitting
    Connection
    Gender
    Port
    Type
    Flange
    OD
    No. of
    Holes
    Hole
    Size
    Included
    Circle
    Dia.
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Max. Steam Pressure
    @ Temp.
    Manual
    Override
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Lg.
    Ht.
    Specs. Met
    Each
    Fail in Place—24V AC/24V DC
    2
    Flanged
    FemaleFull6"45/8"No4 3/4"307.4275 psi @ 100° F100 psi @ 338° FYesBall
    Zero Pressure Drop
    0 to 3653 1/4"7 3/4"15 1/4"ASME B16.342531N14000000000
    3
    Flanged
    FemaleFull7 1/4"45/8"No6"1,012.68275 psi @ 100° F100 psi @ 338° FYesBall
    Zero Pressure Drop
    0 to 3654 13/16"10 1/2"22 5/8"ASME B16.342531N1500000000
     
    Fail in Place—120V AC
    2
    Flanged
    FemaleFull6"45/8"No4 3/4"307.4275 psi @ 100° F100 psi @ 338° FYesBall
    Zero Pressure Drop
    0 to 3653 1/4"7 3/4"19 1/16"ASME B16.342531N1100000000
    3
    Flanged
    FemaleFull7 1/4"45/8"No6"1,012.68275 psi @ 100° F100 psi @ 338° FYesBall
    Zero Pressure Drop
    0 to 3654 13/16"10 1/2"22 5/8"ASME B16.342531N1200000000
     

    High-Flow Flanged Air-Driven On/Off Valves

    Image of Product. Front orientation. Contains Annotated. Air-Actuated On/Off Valves. High-Flow Flanged Air-Driven On/Off Valves.
    Their ball-valve design allows these valves to handle three times the flow of other flanged valves. They operate on compressed air to automatically start and stop flow faster actuation than motor-driven valves. You must control the air to the actuator using either the included electric pilot valve or a manual on/off valve (not included). These valves don’t require a minimum pressure drop between the inlet and outlet for operation. All are full port, so they do not restrict flow.
    The actuator is secured to the valve body with a bracket for easy disassembly, maintenance, and repair. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. The manual override allows you to operate the valve during power outages.
    Single Acting—Single-acting actuators only require air pressure to open the valve; they automatically spring closed when the air turns off. These valves are fail closed unless actuated.
    Double Acting—Double-acting actuators require air pressure to open and close the valve. Once actuated, these valves remain actuated until air pressure is applied to close them, so they do not have a valve starting position.
    Flow Coefficient (Cv)—Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
    Bolts
    Air
    Pipe
    Size
    Gender
    Flange
    OD
    No. of
    Holes
    Hole
    Size
    Included
    Circle
    Dia.
    Flow Coefficient
    (Cv)
    Max. Pressure
    @ Temp.
    Max. Steam Pressure
    @ Temp.
    Valve Type
    Temp. Range,
    ° F
    Valve
    Lg.
    Overall
    Ht.
    Connection
    Min. Pressure,
    psi
    Max. Pressure,
    psi
    Specs. Met
    Each
    Carbon Steel Body with Screw Terminals
     
    Single Acting: Air-to-Open, Spring Return (Fail Closed)—120V AC
    2
    Female6"45/8"No4 3/4"307.4285 psi @ 100° F100 psi @ 338° FBall, Zero Pressure Drop0 to 3653 1/4"14"1/4 NPT Female40115ASME B16.342534N14000000000
    3
    Female7 1/2"45/8"No6"1,012.68285 psi @ 100° F100 psi @ 338° FBall, Zero Pressure Drop0 to 3654 13/16"18 5/16"1/4 NPT Female40115ASME B16.342534N1500000000
     
    Double Acting: Air-to-Open, Air-to-Close—120V AC
    2
    Female6"45/8"No4 3/4"307.4285 psi @ 100° F100 psi @ 338° FBall, Zero Pressure Drop0 to 3653 1/4"12 15/16"1/4 NPT Female40115ASME B16.342534N11000000
    3
    Female7 1/4"45/8"No6"1,012.68285 psi @ 100° F100 psi @ 338° FBall, Zero Pressure Drop0 to 3654 13/16"19 15/16"1/4 NPT Female40115ASME B16.342534N1200000000
     
    back to top