Filter by
Electrical Connection
Electrical Safety Rating
Calculation Features
Frequency
AC Voltage
DC Voltage
DFARS Specialty Metals
Measurement Unit
Display Features
Software Features
BNC Test Cords
![]() | ![]() |
Style A | Style B |
![]() | ![]() |
Style C | Style D |
Connect oscilloscopes and other bench-top testers.
Hand-held voltage ratings are the maximum tested voltage for applications where you hold the cord in your hands while testing. The hands-free voltage ratings are the maximum voltage the cord is rated to withstand.
Standard Banana Connection—Standard banana connection ends hook up to multimeters and other equipment with banana jacks.
AC Voltage Rating, V AC | DC Voltage Rating, V DC | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Style | Connection End | Hand Held | Hands Free | Hand Held | Hands Free | Color | Choose a Length | Each | ||
A | BNC Plug × BNC Plug | 30 | 500 | 60 | 500 | Black | 36" , 48" , 60" | 0000000 | 000000 | |
B | BNC Plug × Two Sleeved Alligator Clips | 30 | 150 | 60 | — | Black | 36" , 60" | 0000000 | 00000 | |
C | BNC Plug × Two Sheathed Retractable Standard Banana Plugs | 30 | 500 | 60 | 500 | Black | 36" , 60" | 0000000 | 00000 | |
D | BNC Plug × Two Retractable Hooks | 30 | 300 | 60 | — | Black | 24" , 36" | 0000000 | 00000 |
Oscilloscopes
![]() |
For Computers |
These oscilloscopes graph electrical waveforms over time, allowing you to analyze signal transmission issues, voltage spikes, stray voltage, and other problems with electrical equipment. For the most accurate measurements, the oscilloscope's frequency should be at least five times the maximum signal frequency you intend to measure.
For Computers—Oscilloscopes for computers only connect using the included USB cable. Use your computer to program settings, save, and analyze results. they also have a 7" widescreen display to view readings and a panel with the traditional knobs to program and fine-tune settings directly on the device. Insert a flash drive in the USB port to save a screenshot of your waveform. Compatible with Windows operating systems.
No. of Digital Channels | Freq., MHz | Real-Time Sample Rate, Gsps | Rise Time, ns | Vert. Sensitivity Range | AC Voltage, V AC | DC Voltage, V DC | DC Voltage Accuracy | Input AC Voltage, V AC | For Operating System | Includes | Data Connection | Electrical Safety Rating | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Computers | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
2 | 0 to 100 | 1 | 0 to 3.5 | 2 mV/div to 10 V/div | 0 to 400 | 0 to 400 | 3% | 100 to 240 | Windows | PC Software, Two-Piece 10:1 Probe Set, USB Cable | USB-B | CAT I, 400V | 000000 | 0000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke Oscilloscope/Multimeters
![]() |
Perform electrical tests, record data, and see a graph of electrical waveforms with this combination multimeter and oscilloscope. Fluke oscilloscope/multimeters are known for quality and durability.
To download and analyze data on a computer, software is required (not included).
When used as an oscilloscope, the oscilloscope/multimeter is most accurate when the frequency is at least five times the maximum signal frequency you intend to measure.
True RMS AC Calculation—The multimeter function is true RMS, so it accurately takes AC measurements regardless of the load type or sine wave shape. This is important for testing electronic devices that draw current in short pulses that can distort the shape of the wave, such as computers and adjustable-speed drives.
Display Count—Display count is an industry designation and not an actual value. This 5,000-count oscilloscope/multimeter shows numbers up to 4,999.
Mfr. Model No. | No. of Digital Channels | Freq., MHz | Electrical Safety Rating | Max. AC Voltage, V AC | Max. DC Voltage, V DC | DC Voltage Accuracy | Display Count | Data Log Cap. | Includes | Certification | Measures | Batteries Included | Each | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
True RMS AC Calculation | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
123B | 2 | 0 to 20 | CAT IV, 600V | 600 | 600 | 0.5% | 5,000 | 512 | Alligator Clips, Battery Charger, BNC Adapter, Probe Tips, Test Leads | CSA Certified | AC Voltage, Capacitance, Continuity, DC Voltage, Temperature | Yes | 0000000 | 000000000 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||