NEMA Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Color | Each | |
Non-Grounded | ||||||||
---|---|---|---|---|---|---|---|---|
18-60 | 120V AC/208V AC | 60A | 3.1" | Screw Terminals | 0.43"-1.31" | Gray | 0000000 | 000000 |


NEMA Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Features | Color | Each | |
Non-Grounded | |||||||||
---|---|---|---|---|---|---|---|---|---|
18-60 | 120V AC/208V AC | 60A | 3.3" | Screw Terminals | 0.63"-1.38" | Rotating Face | Black | 0000000 | 000000 |


NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Color | Each | |
Non-Grounded | |||||||||
---|---|---|---|---|---|---|---|---|---|
18-60 | 120V AC/208V AC | 60A | 2.1" | Screw Terminals | Back | Outlet Box | Black | 0000000 | 000000 |
Premium Straight-Blade Plugs, Sockets, and Receptacles
Built to handle tough, repetitive-use applications, these are more durable than standard straight-blade connectors.
Receptacles for outlet boxes fit standard wall plates (not included).
Note: The current rating of your plug should not exceed that of your socket or receptacle.


NEMA Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Environmental Rating | Specifications Met | Color | Each | |
Non-Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
18-60 | 120V AC/208V AC | 60A | 2.9" | Screw Terminals | 0.63"-1.31" | IP20 | UL Listed, UL 94 HB | Black | 0000000 | 0000000 |


NEMA Style | Voltage | Current | Wd. | Wire Connection Type | For Cable OD | Specifications Met | Color | Each | |
Non-Grounded | |||||||||
---|---|---|---|---|---|---|---|---|---|
18-60 | 120V AC/208V AC | 60A | 3.4" | Screw Terminals | 0.63"-1.31" | UL Listed, UL 498 | Black | 0000000 | 0000000 |


NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Environmental Rating | Specifications Met | Color | Each | |
Non-Grounded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
18-60 | 120V AC/208V AC | 60A | 2.3" | Screw Terminals | Back, Side | Outlet Box | IP20 | UL Listed, CSA Certified, UL 94 HB | Black | 0000000 | 0000000 |
Turn-Lock Plugs, Sockets, and Receptacles
A quarter turn locks these connectors in place to remain secure in high-vibration applications and prevent accidental disconnection.
Receptacles for outlet boxes fit standard wall plates (not included).















NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Specifications Met | Color | Each | |
Non-Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L18-20 | 120V AC/208V AC | 20A | 1.6" | Screw Terminals | Back, Side | Outlet Box | UL Listed, CSA Certified | Black | 000000 | 000000 |
L18-30 | 120V AC/208V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | UL Listed, CSA Certified | Black | 0000000 | 00000 |



NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Specifications Met | Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L21-20 | 120V AC/208V AC | 20A | 1.6" | Screw Terminals | Back | Outlet Box | UL Listed, CSA Certified | Black | 0000000 | 000000 |
L21-30 | 120V AC/208V AC | 30A | 1.6" | Screw Terminals | Back | Outlet Box | UL Listed, CSA Certified | Black | 0000000 | 00000 |



NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | For Panel Cutout Dia. | Specifications Met | Color | Each | |
Non-Grounded | |||||||||
---|---|---|---|---|---|---|---|---|---|
L18-20 | 120V AC/208V AC | 20A | Screw Terminals | Back, Side | 2.1" | UL Listed, CSA Certified | Gray | 0000000 | 000000 |
L18-30 | 120V AC/208V AC | 30A | Screw Terminals | Back, Side | 2.3" | UL Listed, CSA Certified | Gray | 0000000 | 00000 |



NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | For Panel Cutout Dia. | Specifications Met | Color | Each | |
Grounded | |||||||||
---|---|---|---|---|---|---|---|---|---|
L21-20 | 120V AC/208V AC | 20A | Screw Terminals | Back, Side | 2.1" | UL Listed, CSA Certified | Gray | 0000000 | 000000 |
L21-30 | 120V AC/208V AC | 30A | Screw Terminals | Back, Side | 2.3" | UL Listed, CSA Certified | Gray | 0000000 | 000000 |



NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | For Panel Cutout Dia. | Specifications Met | Color | Each | |
Non-Grounded | |||||||||
---|---|---|---|---|---|---|---|---|---|
L18-20 | 120V AC/208V AC | 20A | Screw Terminals | Back, Side | 2.3" | UL Listed, CSA Certified | Gray | 0000000 | 000000 |
L18-30 | 120V AC/208V AC | 30A | Screw Terminals | Back, Side | 2.3" | UL Listed, CSA Certified | Gray | 0000000 | 00000 |



NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | For Panel Cutout Dia. | Specifications Met | Color | Each | |
Grounded | |||||||||
---|---|---|---|---|---|---|---|---|---|
L21-20 | 120V AC/208V AC | 20A | Screw Terminals | Back, Side | 2.3" | UL Listed, CSA Certified | Gray | 0000000 | 000000 |
L21-30 | 120V AC/208V AC | 30A | Screw Terminals | Back, Side | 2.3" | UL Listed, CSA Certified | Gray | 0000000 | 00000 |
Premium Turn-Lock Plugs, Sockets, and Receptacles
Also known as twist-lock devices, these connectors are built to handle tough, repetitive-use applications, and are more durable than standard turn-lock connectors. A quarter turn locks them in place to remain secure in high-vibration applications and prevent accidental disconnection.
Receptacles for outlet boxes fit standard wall plates (not included).



NEMA Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Color | Environmental Rating | Specifications Met | Each | |
Non-Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L18-20 | 120V AC/208V AC | 20A | 2.3" | Screw Terminals | 0.35"-1.15" | Black | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 0000000 | 000000 |
L18-30 | 120V AC/208V AC | 30A | 2.3" | Screw Terminals | 0.35"-1.15" | Black | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 0000000 | 00000 |



NEMA Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Color | Environmental Rating | Specifications Met | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L21-20 | 120V AC/208V AC | 20A | 2.3" | Screw Terminals | 0.35"-1.15" | Black | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 0000000 | 000000 |
L21-30 | 120V AC/208V AC | 30A | 2.3" | Screw Terminals | 0.35"-1.15" | Black | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 0000000 | 00000 |



NEMA Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Color | Environmental Rating | Specifications Met | Each | |
Non-Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L18-20 | 120V AC/208V AC | 20A | 2.3" | Screw Terminals | 0.35"-1.15" | Black | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 0000000 | 000000 |
L18-30 | 120V AC/208V AC | 30A | 2.3" | Screw Terminals | 0.35"-1.15" | Black | __ | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 0000000 | 000000 |



NEMA Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Color | Specifications Met | Each | |
Grounded | |||||||||
---|---|---|---|---|---|---|---|---|---|
L21-20 | 120V AC/208V AC | 20A | 2.3" | Screw Terminals | 0.35"-1.15" | Black | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 0000000 | 0000000 |
L21-30 | 120V AC/208V AC | 30A | 2.3" | Screw Terminals | 0.35"-1.15" | Black | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 0000000 | 000000 |



NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Color | Environmental Rating | Specifications Met | Each | |
Non-Grounded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
L18-20 | 120V AC/208V AC | 20A | 1.6" | Screw Terminals | Back, Side | Outlet Box | Black | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 V-2, UL 498 | 0000000 | 000000 |
L18-30 | 120V AC/208V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | Black | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 V-2, UL 498 | 0000000 | 00000 |



NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Color | Environmental Rating | Specifications Met | Each | |
Grounded | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
L21-20 | 120V AC/208V AC | 20A | 1.6" | Screw Terminals | Back, Side | Outlet Box | Black | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 V-2, UL 498 | 0000000 | 000000 |
L21-30 | 120V AC/208V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | Black | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 V-2, UL 498 | 0000000 | 00000 |


NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | For Panel Cutout Dia. | Color | Environmental Rating | Specifications Met | Each | |
Non-Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L18-20 | 120V AC/208V AC | 20A | Screw Terminals | Back | 2.2" | White | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 00000000 | 000000 |



NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | For Panel Cutout Dia. | Color | Environmental Rating | Specifications Met | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L21-20 | 120V AC/208V AC | 20A | Screw Terminals | Back | 2.2" | White | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 00000000 | 0000000 |
L21-30 | 120V AC/208V AC | 30A | Screw Terminals | Back | 2.2" | White | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 00000000 | 000000 |

NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | For Panel Cutout Dia. | Color | Environmental Rating | Specifications Met | Each | |
Non-Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L18-20 | 120V AC/208V AC | 20A | Screw Terminals | Back | 2.2" | White | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 0000000 | 000000 |



NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | For Panel Cutout Dia. | Color | Environmental Rating | Specifications Met | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L21-20 | 120V AC/208V AC | 20A | Screw Terminals | Back | 2.2" | White | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 0000000 | 000000 |
L21-30 | 120V AC/208V AC | 30A | Screw Terminals | Back | 2.2" | White | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 94 HB, UL 498 | 0000000 | 00000 |
Interference-Limiting Turn-Lock Receptacles
Protect computers and other sensitive equipment from electromagnetic interference (EMI). Also known as isolated ground receptacles, they have a ground terminal that is insulated from the mounting strap so you can run an isolated ground wire through the conduit. When mated with a plug, a quarter turn locks them in place to remain secure in high-vibration applications and prevent accidental disconnection. Receptacles fit standard wall plates (not included).



NEMA Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Features | Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L21-20 | 120V AC/208V AC | 20A | 1.6" | Screw Terminals | Back, Side | Outlet Box | Green Triangle, Isolated Ground Connection | Orange | 0000000 | 000000 |
L21-30 | 120V AC/208V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | Green Triangle, Isolated Ground Connection | Orange | 0000000 | 00000 |
Washdown Turn-Lock Connectors and Cords
When mated, connectors meet NEMA 6P for protection against corrosion and washdowns. All have a multiple-ring seal and rubber housing to keep out liquid. They resist heat, oil, and chemicals. A quarter turn locks them in place to remain secure in high-vibration applications and prevent accidental disconnection.
Plugs mate with female receptacles and female sockets with an attached cover.
Male receptacles mate with female sockets without an attached cover.



Plugs | Caps for Plugs | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
NEMA Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Color | Each | Each | ||
Grounded | ||||||||||
L21-20 | 120V AC/208V AC | 20A | 2.5" | Screw Terminals | 0.56"-0.81" | Yellow | 000000000 | 000000 | 000000000 | 000000 |
L21-20 | 120V AC/208V AC | 20A | 2.5" | Screw Terminals | 0.56"-0.81" | Black | 000000000 | 00000 | 000000000 | 00000 |
L21-30 | 120V AC/208V AC | 30A | 2.8" | Screw Terminals | 0.63"-0.81" | Yellow | 000000000 | 00000 | 000000000 | 00000 |



Sockets | Replacement Caps for Sockets | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
NEMA Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Color | Each | Each | ||
Grounded | ||||||||||
L21-20 | 120V AC/208V AC | 20A | 2.5" | Screw Terminals | 0.56"-0.81" | Yellow | 000000000 | 0000000 | 000000000 | 000000 |
L21-20 | 120V AC/208V AC | 20A | 2.5" | Screw Terminals | 0.56"-0.81" | Black | 000000000 | 000000 | 000000000 | 00000 |
L21-30 | 120V AC/208V AC | 30A | 2.8" | Screw Terminals | 0.63"-0.81" | Yellow | 000000000 | 000000 | 000000000 | 00000 |



NEMA Style | Voltage | Current | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Color | Each | |
Grounded | ||||||||
---|---|---|---|---|---|---|---|---|
L21-20 | 120V AC/208V AC | 20A | Screw Terminals | Back | Outlet Box | Yellow | 000000000 | 000000 |
L21-20 | 120V AC/208V AC | 20A | Screw Terminals | Back, Front, Side | Outlet Box | Black | 000000000 | 000000 |
L21-30 | 120V AC/208V AC | 30A | Screw Terminals | Back | Outlet Box | Yellow | 000000000 | 000000 |
Corrosion-Resistant Turn-Lock Connectors
Stainless steel hardware and nickel-plated blades or slots protect connectors from damage in corrosive environments. A quarter turn locks them in place to remain secure in high-vibration applications and prevent accidental disconnection.



NEMA Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Environmental Rating | Specifications Met | Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L21-20 | 120V AC/208V AC | 20A | 2.2" | Screw Terminals | 0.35"-1.15" | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 498, UL 94 HB | Yellow | 0000000 | 000000 |
L21-30 | 120V AC/208V AC | 30A | 2.2" | Screw Terminals | 0.35"-1.15" | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 498, UL 94 HB | Yellow | 0000000 | 00000 |



NEMA Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Environmental Rating | Specifications Met | Color | Each | |
Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
L21-20 | 120V AC/208V AC | 20A | 2.3" | Screw Terminals | 0.35"-1.15" | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 498, UL 94 HB | Yellow | 0000000 | 0000000 |
L21-30 | 120V AC/208V AC | 30A | 2.3" | Screw Terminals | 0.35"-1.15" | IP20 | UL Listed, CSA Certified, Fed. Spec. W-C-596, UL 498, UL 94 HB | Yellow | 0000000 | 000000 |
Impact-Resistant Turn-Lock Connectors
A rubber housing protects these connectors from damage caused by drops and impact. Lock them in place with a quarter turn to remain secure in high-vibration applications and prevent accidental disconnection. Not intended for use in wet or damp environments.
Non-NEMA Turn-Lock Connectors
A quarter turn locks these connectors in place to remain secure in high-vibration applications and prevent accidental disconnection. They are not compatible with NEMA configurations.
Receptacles fit standard wall plates (not included).



Style | Voltage | Current | OD | Wire Connection Type | For Cable OD | Specifications Met | Color | Each | |
Non-Grounded | |||||||||
---|---|---|---|---|---|---|---|---|---|
G | 120V AC/208V AC | 20A | 2.2" | Screw Terminals | 0.23"-1.15" | UL Listed, CSA Certified, UL 498, Fed. Spec. W-C-596 | Black | 0000000 | 000000 |
H | 120V AC/208V AC | 30A | 2.2" | Screw Terminals | 0.23"-1.15" | UL Listed, Fed. Spec. W-C-596 | Black | 0000000 | 00000 |






Style | Voltage | Current | Face Dia. | Wire Connection Type | Receptacle Terminal Location | Mounting Location | Specifications Met | Color | Each | |
Non-Grounded | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
G | 120V AC/208V AC | 20A | 1.6" | Screw Terminals | Back, Side | Outlet Box | UL Listed, CSA Certified, UL 498, Fed. Spec. W-C-596 | Black | 0000000 | 000000 |
H | 120V AC/208V AC | 30A | 1.6" | Screw Terminals | Back, Side | Outlet Box | UL Listed, Fed. Spec. W-C-596 | Black | 0000000 | 00000 |
IEC Safe-Break Pin-and-Sleeve Connectors
These connectors meet international standards IEC 309-1 and 309-2, so they’re compatible with other IEC 309 devices. They allow you to connect and disconnect with the power on—spring-loaded contacts open like a switch when separating the connectors, preventing an electrical arc. All are approved as switch-rated connectors for branch and motor circuit disconnect switching. Connectors have a ground pin that is included in the number of wires. Rated NEMA 4X, 12, and IP69K, they're protected against corrosion, oil/coolant seepage, washdowns, and high-temperature, high-pressure washdowns.


AC,
4W5P Male

AC,
4W5P Male

AC,
4W5P Male
Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Wire Connection Type | For Wire Gauge | For Cable OD | Temp. Range, °F | Environmental Rating | Voltage | Each | |
2" | 5 | 1 | 4 | 4W5P | Three | 30A | Screw Terminals | 12-8 | 0.5"-1.45" | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 120V AC/208V AC | 0000000 | 0000000 |


AC,
4W5P Female

AC,
4W5P Female

AC,
4W5P Female
Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Wire Connection Type | For Wire Gauge | For Cable OD | Temp. Range, °F | Features | Environmental Rating | Voltage | Each | |
2" | 5 | 1 | 4 | 4W5P | Three | 30A | Screw Terminals | 12-8 | 0.5"-1.45" | -40° to 165° | Cord Grip, Power-Indicating Light | NEMA 4X, NEMA 12, IP69K | 120V AC/208V AC | 0000000 | 0000000 |


AC,
4W5P Female

AC,
4W5P Female

AC,
4W5P Female
Face Dia. | No. of Poles | No. of Ground Connections | No. of Wires | Industry Designation | Electrical Phase | Current | Wire Connection Type | For Wire Gauge | Features | Temp. Range, °F | Environmental Rating | Voltage | Each | |
2" | 5 | 1 | 4 | 4W5P | Three | 30A | Screw Terminals | 12-8 | Cord Grip, Power-Indicating Light | -40° to 165° | NEMA 4X, NEMA 12, IP69K | 120V AC/208V AC | 0000000 | 0000000 |