How to Prime Your Pump
More
How to Determine Feet of Head
More
About Process Pumps
More
Stainless Steel Circulation Pumps for Chemicals
A 316 stainless steel housing sealed with fluoroelastomer resists mild chemicals and acids, such as coolant, oil, and phosphoric acid. These pumps have a totally enclosed fan-cooled (TEFC) motor for use in dusty, dirty, and damp environments. They are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | |||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | Replacement Impellers | |||||||||||||||||||
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | @ 60 ft. of Head | @ 70 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Solids Dia. | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | Each | ||
120/240V AC, Single Phase—With Thermal Overload Protection | |||||||||||||||||||||||
Hardwire | |||||||||||||||||||||||
32 | __ | 22 | 10 | __ | __ | __ | 44 | 100 | 1/8" | 50 | 1/3 | 5.6/2.8 | 3/4 | Female | 1/2 | Female | 15" | 9" | 7 1/2" | 0000000 | 0000000 | 0000000 | 0000000 |
32 | __ | 32 | 32 | 20 | __ | __ | 62 | 100 | 3/32" | 50 | 3/4 | 10.6/5.3 | 1 1/4 | Female | 3/4 | Female | 16" | 9" | 7 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
36 | __ | 30 | 22 | __ | __ | __ | 54 | 100 | 1/8" | 50 | 1/2 | 7.6/3.8 | 3/4 | Female | 1/2 | Female | 15" | 9" | 7 1/2" | 0000000 | 000000 | 0000000 | 000000 |
38 | __ | 33 | 27 | 18 | __ | __ | 59 | 100 | 1/8" | 50 | 3/4 | 10.6/5.3 | 3/4 | Female | 1/2 | Female | 15" | 9" | 7 1/2" | 0000000 | 000000 | 0000000 | 000000 |
90 | 82 | 63 | 35 | __ | __ | __ | 60 | 100 | 3/32" | 50 | 1 | 12.6/6.3 | 1 1/2 | Female | 1 1/4 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
240/460V AC, Three Phase—With Thermal Overload Protection | |||||||||||||||||||||||
Hardwire | |||||||||||||||||||||||
75 | 47 | 15 | __ | __ | __ | __ | 34 | 100 | 3/16" | 50 | 1 | 2.9/1.4 | 1 1/2 | Female | 1 1/4 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
95 | 80 | 55 | 20 | __ | __ | __ | 49 | 100 | 3/16" | 50 | 1 1/2 | 3.9/2 | 1 1/2 | Female | 1 1/4 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
110 | 100 | 80 | 58 | 28 | __ | __ | 70 | 100 | 3/32" | 50 | 1 1/2 | 3.9/2 | 1 1/2 | Female | 1 1/4 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
115 | __ | __ | 55 | __ | __ | __ | 52 | 100 | 3/16" | 50 | 2 | 5.3/2.7 | 2 | Female | 1 1/2 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
130 | __ | __ | __ | 90 | 60 | __ | 82 | 100 | 3/32" | 50 | 2 | 5.3/2.7 | 2 | Female | 1 1/2 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
130 | __ | __ | __ | 95 | 55 | __ | 79 | 100 | 3/16" | 50 | 3 | 7.6/3.8 | 2 | Female | 1 1/2 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
140 | __ | __ | __ | __ | 85 | 55 | 88 | 100 | 3/32" | 50 | 3 | 7.6/3.8 | 2 | Female | 1 1/2 | Female | 16" | 9" | 8 3/4" | 0000000 | 00000000 | 0000000 | 000000 |
Self-Priming Stainless Steel Circulation Pumps for Chemicals
Self-priming up to 6 ft., these pumps have a stainless steel housing sealed with PTFE to resist chemicals such as ammonia and detergents as well as harsh solvents including methyl ethyl ketone (MEK). The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are self-priming after you fill the pump chamber with liquid. As liquid in the chamber is expelled, a suction force is created which allows the pump to draw liquid upward.
Note: Pumps must be filled with liquid before use. They need a constant flow of liquid and cannot run dry. If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Flow Rate, gpm | Intake (NPT) | Discharge (NPT) | Overall | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Max. Flow Rate, gpm | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | @ 60 ft. of Head | Max. ft. of Head | Max. Pressure, psi | Max. Viscosity, cP | hp | Current, A | Pipe Size | Gender | Pipe Size | Gender | Lg. | Wd. | Ht. | Each | ||
120/240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
1 | 68 | 54 | 41 | __ | __ | __ | 50 | 75 | 20 | 3/4 | 9/5 | 1 1/2 | Female | 1 1/2 | Female | 15 3/4" | 8 3/4" | 9 1/2" | 0000000 | 000000000 |
2 | 100 | __ | 65 | 45 | __ | __ | 50 | 75 | 20 | 1 1/2 | 18/9 | 1 1/2 | Female | 1 1/2 | Female | 16 1/2" | 8 3/4" | 9 1/2" | 0000000 | 00000000 |
240/460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||||||
Hardwire | ||||||||||||||||||||
3 | 68 | 54 | 41 | __ | __ | __ | 50 | 75 | 20 | 3/4 | 3/2 | 1 1/2 | Female | 1 1/2 | Female | 15 1/4" | 8 3/4" | 9 1/2" | 0000000 | 00000000 |
4 | 100 | __ | 65 | 45 | __ | __ | 50 | 75 | 20 | 1 1/2 | 5/3 | 1 1/2 | Female | 1 1/2 | Female | 16 1/4" | 8 3/4" | 9 1/2" | 0000000 | 00000000 |
5 | 132 | __ | __ | 82 | 60 | 14 | 63 | 75 | 20 | 2 | 6/3 | 1 1/2 | Female | 1 1/2 | Female | 17 1/4" | 8 3/4" | 9 1/2" | 0000000 | 00000000 |
Extended-Life Plastic Circulation Pumps for Chemicals
These pumps have the best chemical resistance of all our circulation pumps. Instead of a shaft seal, they use magnets to turn the impeller, reducing wear and leakage. The motor is totally enclosed fan-cooled (TEFC) for use in dusty, dirty, and damp environments. Pumps are gravity fed and require an elevated liquid source. Do not run dry or use with solids.
Pumps that cannot be sold to Canada are restricted due to energy efficiency regulations.
Note: If flow control is needed, place valves or reducers on the discharge side; never restrict the inlet of a pump with a valve or reducer.
Pumps | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gpm | Pipe Size | Overall | Maintenance Kits | Replacement Impellers | ||||||||||||||||||
Max. Flow Rate, gpm | @ 10 ft. of Head | @ 20 ft. of Head | @ 30 ft. of Head | @ 40 ft. of Head | @ 50 ft. of Head | @ 60 ft. of Head | Max. ft. of Head | Max. Viscosity, cP | hp | Current, A | Intake (Gender) | Discharge (Gender) | Lg. | Wd. | Ht. | Cannot Be Sold To | Each | Each | Each | |||
120V AC, 240V AC, Single Phase—Without Thermal Overload Protection | ||||||||||||||||||||||
Hardwire | ||||||||||||||||||||||
23 | __ | 20 | 10 | __ | __ | __ | 35 | __ | 1/4 | 2.07/4.14 | 1 (Female) | 1 (Female) | 14 3/8" | 5 1/8" | 7 7/8" | __ | 0000000 | 000000000 | 00000000 | 000000 | 00000000 | 0000000 |
26 | __ | 26 | 12 | __ | __ | __ | 35 | __ | 1/3 | 3.24/6.84 | 1 (Female) | 1 (Female) | 16 5/16" | 6 1/8" | 8 3/16" | __ | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
240V AC, 460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||||||||
Hardwire | ||||||||||||||||||||||
57 | 57 | 53 | 30 | 25 | __ | __ | 45 | __ | 1/2 | 1.1/2.2 | 1 1/2 (Female) | 1 1/2 (Female) | 18 3/8" | 8 7/8" | 11 5/16" | __ | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
90 | 90 | 84 | 74 | 61 | 49 | __ | 70 | __ | 1 | 1.5/3 | 1 1/2 (Female) | 1 1/2 (Female) | 18 7/8" | 6 5/16" | 10 1/8" | __ | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
120V AC, 208–240V AC, Single Phase—With Thermal Overload Protection | ||||||||||||||||||||||
Hardwire | ||||||||||||||||||||||
38 | 36 | 32 | 27 | 21 | __ | __ | 49 | 5 | 1/2 | 7.5/3.7-3.7 | 1 (Female) | 3/4 (Male) | 15 1/2" | 9" | 8 1/4" | __ | 0000000 | 00000000 | 00000000 | 0000 | 00000000 | 000000 |
53 | 53 | 46 | 40 | 33 | 23 | 2 | 60 | 5 | 1 | 9.2/6.3-4.6 | 1 1/2 (Female) | 1 (Male) | 17 13/16" | 9 1/8" | 8 3/16" | __ | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
208–240V AC, 460V AC, Three Phase—Without Thermal Overload Protection | ||||||||||||||||||||||
Hardwire | ||||||||||||||||||||||
30 | 31 | 26 | 20 | 7 | __ | __ | 41 | 5 | 1/3 | 0.6/1.3-1.2 | 1 (Female) | 3/4 (Male) | 15 1/16" | 9 1/4" | 7 3/8" | __ | 0000000 | 00000000 | 00000000 | 0000 | 00000000 | 000000 |
38 | 36 | 32 | 27 | 21 | __ | __ | 49 | 5 | 1/2 | 1.7/1.7-0.8 | 1 (Female) | 3/4 (Male) | 15 1/16" | 9 1/8" | 7 3/16" | __ | 0000000 | 00000000 | 00000000 | 0000 | 00000000 | 000000 |
53 | 53 | 46 | 40 | 33 | 23 | 2 | 60 | 5 | 1 | 1.1/3.3-2.2 | 1 1/2 (Female) | 1 (Male) | 16 9/16" | 9 1/8" | 7 3/8" | __ | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 000000 |
82 | 82 | 82 | 81 | 80 | 71 | 61 | 85 | 5 | 2 | 2.4/4.9-4.8 | 2 (Male) | 1 1/2 (Male) | 20 11/16" | 10 3/8" | 10" | Canada | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 00000000 |
120 | 120 | 120 | 120 | 112 | 105 | 92 | 95 | 5 | 3 | 3.9/8-7.8 | 2 (Male) | 1 1/2 (Male) | 24 3/8" | 11 1/2" | 10 1/2" | __ | 0000000 | 00000000 | 00000000 | 00000 | 00000000 | 00000000 |
Impellers for Circulation Pumps
Match your pump’s manufacturer and model number to choose the right replacement impeller.
For Pump Model Number | For Pump Part Number | Kit Number | Each | |
AMT Pump Company | ||||
---|---|---|---|---|
__ | 3680-975-97, 5160-975-97 | 3680-015-09 | 0000000 | 0000000 |
__ | 3696-975-97 | 3696-013-98 | 00000000 | 000000 |
2761-95 | 2761-95 | 2820-011-0B | 000000000 | 00000 |
2762-95, 276B-95 | 2762-95, 276B-95 | 2820-011-09 | 000000000 | 00000 |
2764-95, 276D-95 | 2764-95, 276D-95 | 2820-011-0A | 000000000 | 00000 |
276C-95 | 276C-95 | 2820-011-0C | 000000000 | 00000 |
282A-95 | 282A-95 | 2820-011-05 | 000000000 | 00000 |
282B-95 | 282B-95 | 2820-011-06 | 000000000 | 00000 |
282C-95 | 282C-95 | 2820-011-03 | 000000000 | 00000 |
282D-95 | 282D-95 | 2820-011-01 | 000000000 | 00000 |
282E-95 | 282E-95 | 2820-011-07 | 000000000 | 00000 |
282F-95 | 282F-95 | 2820-011-02 | 000000000 | 00000 |
282K-95 | 282K-95 | 2820-011-04 | 000000000 | 00000 |
282M-95 | 282M-95 | 2820-011-08 | 000000000 | 00000 |
2851-95, 285E-95 | 2851-95, 285E-95 | 2850-010-01 | 000000000 | 00000 |
2852-95, 285F-95 | 2852-95, 285F-95 | 2850-010-03 | 000000000 | 00000 |
2853-95, 285G-95 | 2853-95, 285G-95 | 2850-010-05 | 000000000 | 00000 |
2855-95, 285H-95 | 2855-95, 285H-95 | 2850-010-07 | 000000000 | 00000 |
285J-95 | 285J-95 | 2850-010-06 | 000000000 | 00000 |
285K-95 | 285K-95 | 2850-010-08 | 000000000 | 00000 |
285P-95 | 285P-95 | 2850-010-04 | 000000000 | 00000 |
2874-95 | 2874-95 | 2874-013-90 | 00000000 | 000000 |
2875-95 | 2875-95 | 2875-013-90 | 00000000 | 000000 |
2876-95 | 2876-95 | 2876-013-90 | 000000000 | 000000 |
Anderson Process | ||||
AM Series | TM2FE-ER-VT-076-AA | TM-M3L23E-Z | 00000000 | 000000 |
AM Series | TM2GE-ER-VT-090-AA | TM-M5L02E-Z | 00000000 | 000000 |
AMX Series | TM4HC-EC-VT-090-BA | TM-X0L05EC | 00000000 | 000000 |
AMX Series | TM4KC-EC-VT-108-BA | TM-X1L05EC | 00000000 | 000000 |
AMX Series | TM6LC-EC-VT-123-BA | TM-X2L05EC | 00000000 | 000000 |
AMX Series | TM6MC-EC-VT-135-BA | TM-X3L05EC | 00000000 | 000000 |
Finish Thompson | ||||
AC | AC4STS1V300B015C05, AC5RTS1V300B015C13 | A102105-1 | 0000000 | 000000 |
AC | AC4STS1V320B015C08 | A102105-2 | 0000000 | 000000 |
AC | AC4STS1V350B015C15, AC5RTS1V350B015C22 | A102105-3 | 0000000 | 000000 |
AC | AC5RTS2V370B015C24 | A102105-4 | 0000000 | 000000 |
AC | AC5RTS2V450B015C25 | A102105-5 | 0000000 | 000000 |
AC | AC5STS1V400B015C12, AC5STS2V400B015C06 | A102114-1 | 0000000 | 000000 |
AC | AC5STS1V420B015C22 | A102114-2 | 0000000 | 000000 |
AC | AC5STS3V458B015C24 | A102114-11 | 0000000 | 000000 |
AC | AC5STS3V478B015C25 | A102114-12 | 0000000 | 000000 |
Goulds Pumps | ||||
1GD, 3888D3, 3888D4, 3SD, 3SDX, 4SD, 4SDX | __ | 4K11 | 0000000 | 00000 |
GT | __ | 2K713 | 0000000 | 00000 |
Graymills | ||||
IMS, IMV | IMS08-E, IMS08-F, IMV08-E, IMV08-F | 785-91346 | 0000000 | 00000 |
IMS, IMV | IMS100-F, IMS75-F, IMV100-F, IMV75-F | 785-91356 | 0000000 | 000000 |
IMS, IMV | IMS25-E, IMS25-F, IMV25-E, IMV25-F | 785-91351 | 0000000 | 00000 |
IMS, IMV | IMS50-E, IMS50-F, IMV50-E, IMV50-F | 785-91354 | 0000000 | 00000 |
VPJ | VPJ310-A, VPJ310-B, VPJ35-A, VPJ35-B, VPJ38-A, VPJ38-B | 401-37405 | 0000000 | 000000 |
MP Pumps | ||||
S110C | 25173 | 25021 | 0000000 | 000000 |
S130C | 22730 | 22628 | 0000000 | 000000 |
S130C | 27756 | 25020 | 0000000 | 000000 |
S200C | 22729 | 22689 | 0000000 | 000000 |
S200C | 22737 | 22686 | 0000000 | 000000 |
S30C | 22731 | 22573 | 0000000 | 000000 |
S30C | 22746 | 22143 | 0000000 | 000000 |
S30C | 24189 | 22138 | 0000000 | 000000 |
S60C | 27669 | 27662 | 0000000 | 000000 |
S60C | 27672 | 27663 | 0000000 | 00000000 |
S60C | 27675 | 27664 | 0000000 | 000000 |
S80C | 26539 | 25668 | 0000000 | 000000 |
S80C | 26622 | 26585 | 0000000 | 000000 |
MTH Pumps | ||||
T41 | T41B-AB | BK4100 | 000000000 | 000000 |
T41 | T41C-AB | BK4101 | 000000000 | 000000 |
T41 | T41D-AB | BK4102 | 000000000 | 000000 |
T41 | T41G-AB | BK4104 | 000000000 | 000000 |
T41 | T41J-AB | BK4105 | 000000000 | 000000 |
March | ||||
Series 4 & 5 | TE-5C-MD | 0150-0148-0200 | 0000000 | 000000 |
Series 5.5 | 0151-0027-0300, 0151-0027-0900 | 0151-0046-0300 | 00000000 | 000000 |
Series 6 | 0153-0002-0400, 0153-0002-0500 | 0153-0043-0500 | 00000000 | 000000 |
Series 7 | 0155-0173-0200, 0155-0174-0200 | 0155-0160-0200 | 00000000 | 000000 |
Series 7 & 7.5 | TE-7R-MD | 0155-0165-0100 | 0000000 | 000000 |
Series 7.5 | 0156-0001-0100 | 0156-0004-0200 | 00000000 | 00000000 |
Series 8 | 0157-0008-0200 | 0157-0050-0500 | 00000000 | 00000000 |
RS Corcoran | ||||
2000D | 2DAA05.33-3.25 | 2003D-0325 | 00000000 | 000000 |
2000D | 2DAA05.5-3.75, 2DAA05.52-3.75 | 2003D-0375 | 00000000 | 000000 |
2000D | 2DAA1-4, 2DAA13-4 | 2003D-0400 | 00000000 | 000000 |
2000D | 2DAA1.5-4.44, 2DAB3-4.44 | 2003D-0444 | 00000000 | 000000 |
2000D | 2DAB2-4.25 | 2003D-0425 | 00000000 | 000000 |
Thomsen | ||||
No. 4 | 41021-DA, 41521-DA | 9400-67 | 0000000 | 000000 |
No. 4 | 42021-EA | 9397-67 | 0000000 | 000000 |
No. 4 | 42521-GA | 9395-67 | 0000000 | 000000 |
No. 5 | 50321-KA, 50421-KA | 9405-67 | 0000000 | 000000 |
Maintenance Kits for Circulation Pumps
Keep your circulation pump in working order by replacing broken or worn parts. Match the pump’s manufacturer and model number to choose the right kit.
For Pump Model Number | For Pump Part Number | Kit Number | Each | |
AMT Pump Company | ||||
---|---|---|---|---|
__ | 3680-975-97, 5160-975-97 | 3680-015-09 | 0000000 | 000000 |
__ | 3696-975-97 | 3696-013-98 | 0000000 | 00000 |
2821-95, 2825-95, 2827-95 | 2821-95, 2825-95, 2827-95 | 2820-304-95 | 00000000 | 00000 |
Anderson Process | ||||
AM Series | TM2FE-ER-VT-076-AA | TM-RG241V | 00000000 | 00000 |
AM Series | TM2GE-ER-VT-090-AA | TM-RG244V | 00000000 | 00000 |
AMX Series | TM4HC-EC-VT-090-BA | TM-RG356V | 00000000 | 00000 |
AMX Series | TM4KC-EC-VT-108-BA | TM-RG362V | 00000000 | 00000 |
AMX Series | TM6LC-EC-VT-123-BA, TM6MC-EC-VT-135-BA | TM-RG368V | 00000000 | 00000 |
Finish Thompson | ||||
AC | AC4STS1V300B015C05, AC4STS1V320B015C08, AC4STS1V350B015C15 | A102174 | 0000000 | 000000 |
AC | AC5RTS1V300B015C13, AC5RTS1V350B015C22, AC5RTS2V370B015C24, AC5RTS2V450B015C25, AC5STS1V400B015C12, AC5STS1V420B015C22, AC5STS2V400B015C06, AC5STS3V458B015C24, AC5STS3V478B015C25 | A102147 | 0000000 | 000000 |
Graymills | ||||
IMS | IMS08-E, IMS08-F, IMS25-E, IMS25-F | 02-9551-51 | 00000000 | 00000 |
IMS | IMS100-F, IMS50-E, IMS50-F, IMS75-F | 785-92480 | 00000000 | 000000 |
MTH Pumps | ||||
T41 | T41B-AB, T41C-AB, T41G-AB, T41J-AB | SK4100 | 000000000 | 000000 |
March | ||||
Series 5.5, Series 6 | 0151-0027-0300, 0151-0027-0900, 0153-0002-0400, 0153-0002-0500 | 0153-0015-1000 | 00000000 | 0000 |
Series 7 | 0155-0173-0200, 0155-0174-0200 | 0155-0010-1000 | 00000000 | 00000 |
Series 7.5 | 0156-0001-0100 | 0156-0010-1000 | 00000000 | 00000 |
Series 8 | 0157-0008-0200 | 0157-0011-1000 | 00000000 | 00000 |
RS Corcoran | ||||
2000D | 2DAA05.33-3.25, 2DAA05.5-3.75, 2DAA05.52-3.75, 2DAA1-4, 2DAA1.5-4.44, 2DAA13-4, 2DAB2-4.25, 2DAB3-4.44 | M0830-1007V | 00000000 | 000000 |
Baseplates for Circulation Pumps
Extend the service life of your pump by mounting it to a baseplate. These heavy duty plates minimize vibration and raise the pump off the floor, preventing damage to the motor from flooding or spills.
For technical drawings and 3-D models, click on a part number.
Overall | |||||
---|---|---|---|---|---|
Material | Lg. | Wd. | Ht. | Each | |
For 56C NEMA Frame | |||||
316 Stainless Steel | 24" | 10" | 2 1/2" | 000000 | 0000000 |
Fiberglass | 13" | 9 1/2" | 2 1/2" | 000000 | 000000 |
Fiberglass | 24" | 8 1/2" | 2 3/4" | 000000 | 000000 |
Fiberglass | 24" | 10" | 2 3/4" | 000000 | 000000 |
For 143TC, 145TC NEMA Frame | |||||
316 Stainless Steel | 30 1/2" | 12" | 2 1/2" | 000000 | 000000 |
Fiberglass | 30 1/2" | 12" | 2 3/4" | 000000 | 000000 |
For 182TC, 184TC NEMA Frame | |||||
316 Stainless Steel | 39" | 12" | 2 1/2" | 000000 | 000000 |
Fiberglass | 39" | 12" | 2 3/4" | 000000 | 000000 |