How to Prime Your Pump
More
How to Determine Feet of Head
More
About Process Pumps
More
Panel-Mount Fixed-Flow-Rate Metering Pumps for Chemicals

Install these pumps in a panel cutout. Often used in food and beverage, pharmaceutical, and lab applications, they dispense small amounts of liquid at a set rate. Pumps can be wired to a switch for manual operation, or a PLC for automated equipment. The removable pump head includes an intake tube that quickly connects to your line with barbed fittings (not included). To change lines, disconnect tubing and twist and pull the head off the motor. Then twist on a replacement head (sold separately). Pumps come in three colors for easy identification or to match your existing equipment. All are self-priming and create suction to draw liquid upward. Mount pumps up to 28 ft. above your liquid source. They can run dry.
Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, ml/min. | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Wd. | Ht. | Dp. | Each | |
Blue | ||||||||||
24V DC | ||||||||||
Hardwire | ||||||||||
55 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 0000000 |
160 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
Clear | ||||||||||
24V DC | ||||||||||
Hardwire | ||||||||||
55 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
160 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
Green | ||||||||||
24V DC | ||||||||||
Hardwire | ||||||||||
55 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
160 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
High-Flow Metering Pumps for Chemicals

For high-volume chemical sampling and draining, these pumps have a powerful motor that enables them to move 2,592 gallons of liquid per day. They're commonly used with ammonia, acid-washing solutions, and cleaning fluids. Motor is open dripproof (ODP) for use in clean, dry, and well-ventilated environments. Pumps are self-priming and create a suction force to draw liquid upward. Mount up to 15 feet above your liquid source. They can run dry. Do not use with solids.
Intake | Discharge | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gal./day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | For Tube ID | Tube Connection Type | For Tube ID | Tube Connection Type | Lg. | Wd. | Ht. | Includes | Each | |
120V AC, Single Phase | |||||||||||||||
Plug | |||||||||||||||
2,592 | 20 | 1,000 | 35° to 160° | 1/4 hp | 3.1 | 1/2" | Barbed | 1/2" | Barbed | 10" | 5 1/2" | 10" | 10 5/8" Lg. of 1/2" ID Tygon Tubing (Shore A61) | 0000000 | 0000000 |
Remote-Adjustment High-Pressure Metering Pumps for Chemicals

Automatically control output from a distance using a variety of analog and digital signals, including 4-20mA and external pulse signals. Pumps can also be controlled manually, run on a schedule, or set to cycle on and off. View flow rate on the LED display. These pumps handle pressures four times higher than standard pumps. They meter a consistent amount of liquid within ±1% of the maximum flow. Often used in boiler feed systems and water treatment, they're compatible with chemicals such as cleaning fluids and acid-washing solutions. Pumps are self-priming and create suction to draw liquid upward. They can run dry.
Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gal./day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Lg. | Wd. | Ht. | Each | |
120V AC, Single Phase—With Thermal Overload Protection | ||||||||||
Plug | ||||||||||
0.05-5 | 100 | 1,500 | 32° to 100° | 3/32 hp | 0.6 | 11" | 5 7/8" | 7 3/16" | 00000000 | 000000000 |
0.17-17 | 100 | 1,500 | 32° to 100° | 3/32 hp | 0.6 | 11" | 5 7/8" | 7 3/16" | 00000000 | 00000000 |
0.4-40 | 100 | 1,500 | 32° to 100° | 3/32 hp | 0.6 | 11" | 5 7/8" | 7 3/16" | 00000000 | 00000000 |
0.85-85 | 25 | 1,500 | 32° to 100° | 3/32 hp | 0.6 | 11" | 5 7/8" | 7 3/16" | 00000000 | 00000000 |
Metering Pumps for Chemicals

An adjustment screw lets you increase or decrease flow rate without the hassle of changing tubing. Often used in boiler feed systems and water treatment, these pumps are compatible with chemicals such as cleaning fluids and acid-washing solutions. Pumps are self-priming and create suction to draw liquid upward. They can run dry.
Pumps | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube | Overall | Replacement Collars | Replacement Tubing | ||||||||||||||
Flow Rate, gal./day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | ID | OD | Lg. | Wd. | Ht. | Includes | Each | Each | Each | |||
120V AC, Single Phase | |||||||||||||||||
Plug | |||||||||||||||||
2-12 | 25 | 200 | 35° to 100° | 1/64 hp | 0.3 | 3/16" | 3/8" | 8" | 7" | 6" | 9" Lg. of Tygon Tubing (Shore A70) | 00000000 | 0000000 | 00000000 | 000000 | 00000000 | 000000 |
3-20 | 25 | 200 | 35° to 100° | 1/64 hp | 0.3 | 1/4" | 7/16" | 8" | 7" | 6" | 9" Lg. of Tygon Tubing (Shore A70) | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 |
Replacement Pump Head | 00000000 | Each | 000000 |
High-Pressure Metering Pumps for Chemicals

These pumps can be used with pressures four times higher than standard pumps. An adjustment dial lets you alter flow rate in 2.5% increments of the maximum flow without the hassle of changing tubing. Often used in boiler feed systems and water treatment, they're compatible with chemicals such as cleaning fluids and acid-washing solutions. Pumps are self-priming and create suction to draw liquid upward. They can run dry.
Pumps | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Discharge | Overall | Replacement Pump Heads | Replacement Tubing | ||||||||||||||
Flow Rate, gal./day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Tube ID | Tube OD | Lg. | Wd. | Ht. | Includes | Each | Each | Each | |||
120V AC, Single Phase | |||||||||||||||||
Plug | |||||||||||||||||
0.3-5 | 100 | 1,500 | 35° to 125° | 1/30 hp | 1.7 | 3/16" | 1/4" | 11" | 5" | 6" | 20-ft. Lg. of LDPE Plastic Intake/Discharge Tubing | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 000000 |
0.8-17 | 100 | 1,500 | 35° to 125° | 1/30 hp | 1.7 | 3/16" | 1/4" | 11" | 5" | 6" | 20-ft. Lg. of LDPE Plastic Intake/Discharge Tubing | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 00000 |
2-40 | 100 | 1,500 | 35° to 125° | 1/30 hp | 1.7 | 3/16" | 1/4" | 11" | 5" | 6" | 20-ft. Lg. of LDPE Plastic Intake/Discharge Tubing | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 00000 |