Overall | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, gal./day (For Tube ID) | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Lg. | Wd. | Ht. | Includes | Each | |
115V AC,Single Phase—Plug | |||||||||||
PVDF Plastic and Viton® Fluoroelastomer Rubber Wetted Parts Material | |||||||||||
0.02 (1/32") 0.07 (1/16") 0.25 (1/8") | 30 | 800 | 32° to 122° | Subfractional | 0.03 | 5 1/2" | 3 1/4" | 3 3/4" | 4 1/2" Lg. of 1/32" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60) | 000000000 | 0000000 |
0.11 (1/32") 0.34 (1/16") 1.25 (1/8") | 30 | 800 | 32° to 122° | Subfractional | 0.03 | 5 1/2" | 3 1/4" | 3 3/4" | 4 1/2" Lg. of 1/32" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 4 1/2" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60) | 000000000 | 000000 |
0.87 (1/16") 3.53 (1/8") 6.84 (3/16") | 30 | 800 | 32° to 122° | Subfractional | 0.03 | 5 1/2" | 3 1/4" | 3 3/4" | 6" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60) | 000000000 | 000000 |
1.75 (1/16") 7.07 1/8") 13.68 (3/16") | 30 | 800 | 32° to 122° | Subfractional | 0.03 | 5 1/2" | 3 1/4" | 3 3/4" | 6" Lg. of 1/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/8" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60) | 000000000 | 000000 |
22.80 (3/16") 38.00 (1/4") | 15 | 500 | 32° to 122° | Subfractional | 0.52 | 5" | 5" | 7" | 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60) | 000000000 | 000000 |
45.6 (3/16") 76.00 (1/4") | 15 | 200 | 32° to 122° | Subfractional | 0.65 | 5" | 5" | 7" | 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60) | 000000000 | 000000 |
228.00 (3/16") 380.00 (1/4") | 15 | 50 | 32° to 122° | Subfractional | 1.74 | 5" | 5" | 7" | 6" Lg. of 3/16" ID Viton® Fluoroelastomer Tubing (Shore A60), 6" Lg. of 1/4" ID Viton® Fluoroelastomer Tubing (Shore A60) | 000000000 | 000000 |
120V AC/240V AC,Single Phase—Plug | |||||||||||
Norprene and Santoprene Rubber Wetted Parts Material | |||||||||||
6.00 (1/8") 12.00 (3/16") 20.00 (1/4") | 25 | 5,000 | 33° to 104° | Not Rated | 2 | 5 5/8" | 6 1/4" | 5 3/4" | 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60), 9" Lg. of 1/4" ID Norprene Tubing (Shore A60) | 000000000 | 000000 |
26.00 (1/8") 56.00 (3/16") 91.00 (1/4") | 25 | 5,000 | 33° to 104° | Not Rated | 2 | 5 5/8" | 6 1/4" | 5 3/4" | 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60), 9" Lg. of 1/4" ID Norprene Tubing (Shore A60) | 000000000 | 000000 |
42.00 (1/8") 88.00 (3/16") 144.00 (1/4") | 25 | 5,000 | 33° to 104° | Not Rated | 2 | 5 5/8" | 6 1/4" | 5 3/4" | 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60), 9" Lg. of 1/4" ID Norprene Tubing (Shore A60) | 000000000 | 000000 |
77.00 (1/8") 162.00 (3/16") 265.00 (1/4") | 25 | 5,000 | 33° to 104° | Not Rated | 2 | 5 5/8" | 6 1/4" | 5 3/4" | 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60), 9" Lg. of 1/4" ID Norprene Tubing (Shore A60) | 000000000 | 000000 |
122.00 (1/8") 257.00 (3/16") 421.00 (1/4") | 25 | 5,000 | 33° to 104° | Not Rated | 2 | 5 5/8" | 6 1/4" | 5 3/4" | 9" Lg. of 1/8" ID Norprene Tubing (Shore A60), 9" Lg. of 3/16" ID Norprene Tubing (Shore A60), 9" Lg. of 1/4" ID Norprene Tubing (Shore A60) | 000000000 | 000000 |
For Flow Rate, gal./day | Each | |
For PVDF Plastic and Viton® Fluoroelastomer Wetted Parts Material | ||
---|---|---|
0.02-0.11 | 000000000 | 000000 |
0.06-0.34 | 000000000 | 00000 |
0.24-1.25 | 000000000 | 00000 |
0.87-1.75 | 000000000 | 00000 |
3.53-7.07 | 000000000 | 00000 |
6.84-13.68 | 000000000 | 00000 |
22.8-228 | 000000000 | 00000 |
38-380 | 000000000 | 00000 |
For Norprene and Santoprene Wetted Parts Material | ||
1-376 | 00000000 | 00000 |
Panel-Mount Fixed-Flow-Rate Metering Pumps for Chemicals

Install these pumps in a panel cutout. Often used in food and beverage, pharmaceutical, and lab applications, they dispense small amounts of liquid at a set rate. Pumps can be wired to a switch for manual operation, or a PLC for automated equipment. The removable pump head includes an intake tube that quickly connects to your line with barbed fittings (not included). To change lines, disconnect tubing and twist and pull the head off the motor. Then twist on a replacement head (sold separately). Pumps come in three colors for easy identification or to match your existing equipment. All are self-priming and create suction to draw liquid upward. Mount pumps up to 28 ft. above your liquid source. They can run dry.
Overall | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Flow Rate, ml/min. | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Wd. | Ht. | Dp. | Each | |
Blue | ||||||||||
24V DC | ||||||||||
Hardwire | ||||||||||
55 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 0000000 |
160 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
Clear | ||||||||||
24V DC | ||||||||||
Hardwire | ||||||||||
55 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
160 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
Green | ||||||||||
24V DC | ||||||||||
Hardwire | ||||||||||
55 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
160 | 25 | 10,000 | 32° to 100° | 1/150 hp | 1.5 | 2 1/2" | 2 1/2" | 4 1/8" | 00000000 | 000000 |
Metering Pumps for Chemicals

An adjustment screw lets you increase or decrease flow rate without the hassle of changing tubing. Often used in boiler feed systems and water treatment, these pumps are compatible with chemicals such as cleaning fluids and acid-washing solutions. Pumps are self-priming and create suction to draw liquid upward. They can run dry.
Pumps | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
For Tube | Overall | Replacement Collars | Replacement Tubing | ||||||||||||||
Flow Rate, gal./day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | ID | OD | Lg. | Wd. | Ht. | Includes | Each | Each | Each | |||
120V AC, Single Phase | |||||||||||||||||
Plug | |||||||||||||||||
2-12 | 25 | 200 | 35° to 100° | 1/64 hp | 0.3 | 3/16" | 3/8" | 8" | 7" | 6" | 9" Lg. of Tygon Tubing (Shore A70) | 00000000 | 0000000 | 00000000 | 000000 | 00000000 | 000000 |
3-20 | 25 | 200 | 35° to 100° | 1/64 hp | 0.3 | 1/4" | 7/16" | 8" | 7" | 6" | 9" Lg. of Tygon Tubing (Shore A70) | 00000000 | 000000 | 00000000 | 00000 | 00000000 | 00000 |
Replacement Pump Head | 00000000 | Each | 000000 |
High-Pressure Metering Pumps for Chemicals

These pumps can be used with pressures four times higher than standard pumps. An adjustment dial lets you alter flow rate in 2.5% increments of the maximum flow without the hassle of changing tubing. Often used in boiler feed systems and water treatment, they're compatible with chemicals such as cleaning fluids and acid-washing solutions. Pumps are self-priming and create suction to draw liquid upward. They can run dry.
Pumps | |||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Discharge | Overall | Replacement Pump Heads | Replacement Tubing | ||||||||||||||
Flow Rate, gal./day | Max. Pressure, psi | Max. Viscosity, cP | Temp. Range, °F | Horsepower | Current, A | Tube ID | Tube OD | Lg. | Wd. | Ht. | Includes | Each | Each | Each | |||
120V AC, Single Phase | |||||||||||||||||
Plug | |||||||||||||||||
0.3-5 | 100 | 1,500 | 35° to 125° | 1/30 hp | 1.7 | 3/16" | 1/4" | 11" | 5" | 6" | 20-ft. Lg. of LDPE Plastic Intake/Discharge Tubing | 0000000 | 0000000 | 0000000 | 0000000 | 0000000 | 000000 |
0.8-17 | 100 | 1,500 | 35° to 125° | 1/30 hp | 1.7 | 3/16" | 1/4" | 11" | 5" | 6" | 20-ft. Lg. of LDPE Plastic Intake/Discharge Tubing | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 00000 |
2-40 | 100 | 1,500 | 35° to 125° | 1/30 hp | 1.7 | 3/16" | 1/4" | 11" | 5" | 6" | 20-ft. Lg. of LDPE Plastic Intake/Discharge Tubing | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 00000 |