Filter by
Input Voltage
Motor Protection
Mounting Location
Measures
Wire Connection
Reset Type
Trip Time
U.S.–Mexico–Canada Agreement (USMCA) Qualifying
DFARS Specialty Metals
Export Control Classification Number (ECCN)
Mechanical Life Cycles
Switch Starting Position
Electrical Protection Type
Surface-Mount Motor Voltage Monitors
Trip Time, sec. | Switching | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage Range, V AC | No. of Terminals | Control Power, W | Voltage Imbalance Adjustment | Automatic Reset | Delayed Automatic Reset | Current, amp | Voltage, V AC | Ht. | Wd. | Certification | Each | |||
1 Circuit Controlled with 1 Off or 1 On—SPDT | ||||||||||||||
For Three Phase | ||||||||||||||
| 190 to 480 | 7 | 6 | 2% to 8% | 1 to 30 | 1 to 500 | 10 | 240 | 3.5" | 2.08" | UL Listed | 7632K72 | 0000000 | ||
| 475 to 600 | 7 | 6 | 2% to 8% | 1 to 30 | 1 to 500 | 10 | 240 | 3.5" | 2.08" | UL Listed | 7632K74 | 000000 | ||
DIN-Rail Mount Motor Voltage Monitors
Switching | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Input Voltage Range, V AC | No. of Terminals | Control Power, W | Voltage Imbalance Adjustment | Trip Time, sec. | Reset Type | Current, amp | Voltage, V AC | hp @ Voltage | Ht. | Wd. | Certification | Each | |||
1 Circuit Controlled with 1 Off or 1 On—SPDT | |||||||||||||||
For Three Phase | |||||||||||||||
| 200 to 480 | 9 | 5 | 2% to 10% | 1 to 30 | Automatic | 10 | 240 | 1/3 hp @ 240V AC | 3" | 2" | UL Listed, C-UL Listed | 6969K52 | 0000000 | ||
Smart Multifunction Monitoring Relays
No. of Terminals | Input Voltage, V AC | Trip Voltage, V AC | Input Freq., Hz | Trip Freq., Hz | Trip Time, sec. | Reset Type | Switching Current @ Voltage | Max. Switching Voltage, V AC | Ht. | Wd. | Dp. | Operating System Compatibility | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
2 Circuits Controlled with 2 Off or 2 On—DPDT | ||||||||||||||||
With Screw Terminals | ||||||||||||||||
| 12 | 208, 240, 300, 480 | 208 to 480 | 50, 60 | 45 to 66 | 0.1 to 60 | Automatic | 8 amp @ 240V AC | 250 | 3.5" | 0.9" | 3.9" | Android 7.0 or Later, iOS 14.5 or Later | 8452N11 | 0000000 | ||
Socket-Mount Motor Voltage Monitors
Voltage Monitors | Sockets | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Switching | ||||||||||||||||
Input Voltage Range, V AC | No. of Terminals | Control Power, W | Voltage Imbalance Adjustment | Trip Time, sec. | Reset Type | Current, amp | Voltage, V AC | Ht. | Wd. | Certification | Each | Each | ||||
1 Circuit Controlled with 1 Off or 1 On—SPDT | ||||||||||||||||
For Three Phase | ||||||||||||||||
| 200 to 480 | 8 | 5 | 2% to 10% | 0.25 to 30 | Automatic | 10 | 240 | 2.4" | 1.8" | UL Recognized Component, CSA Certified | 6973K73 | 0000000 | 7122K26 | 00000 | ||
Multifunction Monitoring Relays
No. of Terminals | Input Voltage, V DC | Trip Voltage, V AC | Input Freq., Hz | Trip Freq., Hz | Trip Time, sec. | Reset Type | Switching Current @ Voltage | Max. Switching Voltage | Adjustment Mechanism | Ht. | Wd. | Dp. | Each | |||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 Circuit Controlled with 1 Off or 1 On—SPDT | ||||||||||||||||
Screw Terminals with IO-Link | ||||||||||||||||
| 12 | 24 | 90 to 760 | 50, 60 | 15 to 70 | 0.1 to 30 | Automatic | 3 amp @ 240V AC 1 amp @ 24V DC | 400V AC 250V DC | External Controller, Keypad | 3.9" | 0.9" | 3.6" | 8449N12 | 0000000 | ||
Spring-Clamp Terminals with IO-Link | ||||||||||||||||
| 12 | 24 | 90 to 760 | 50, 60 | 15 to 70 | 0.1 to 30 | Automatic | 3 amp @ 240V AC 1 amp @ 24V DC | 400V AC 250V DC | External Controller, Keypad | 3.9" | 0.9" | 3.6" | 8449N11 | 000000 | ||






























