Weatherproof Molex Compact Connector Sets
A sealed polystyrene plastic housing protects connectors from weather. All come assembled with wire leads already installed so they can be quickly added to existing wiring systems. Each set includes one male plug and one female socket. A locking tab keeps them securely in place when mated.
For technical drawings and 3-D models, click on a part number.
Pin | Wire Lead | Mated Housing | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | Wd. | Dp. | Gauge | Lg. | Color | Housing Material | Lg. | Wd. | Ht. | Max. Temp., °F | Environmental Rating | Specifications Met | Each | |
Plug × Socket | ||||||||||||||||
Molex MX150L | ||||||||||||||||
16 | 50V DC | 7A | 0.059" | 0.031" | 18 | 48" | Black | Polystyrene Plastic | 2.85" | 2.35" | 1.18" | 255° | IP67 | SAE J1128 | 0000000 | 0000000 |
16 | 600V AC | 7A | 0.059" | 0.031" | 18 | 48" | Black | Polystyrene Plastic | 2.85" | 2.35" | 1.18" | 255° | IP67 | UL 1015 | 00000000 | 000000 |
16 | 600V AC | 13A | 0.059" | 0.031" | 14 | 48" | Black | Polystyrene Plastic | 2.85" | 2.35" | 1.18" | 255° | IP67 | UL 1015 | 00000000 | 000000 |
Build-Your-Own Latching Connectors
Configure a connector for your application—combine male and female inserts with a base and a hood. Select components based on the number of poles needed. To protect connections while maintaining access, the base and hood latch together securely, yet can be quickly detached for equipment repair or replacement. Once assembled, these connectors are rated NEMA 4X, 12, and IP65 for protection against corrosion, washdowns, dirt, oil/coolant dripping, and water projected from a nozzle.
For technical drawings and 3-D models, click on a part number.
Inserts | Hoods with Side Conduit Connection | Hoods with Top Conduit Connection | Bases | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | For Wire Gauge | Each | Conduit NPT Trade Size | Each | Conduit NPT Trade Size | Each | Each | ||||
Male | |||||||||||||
Spring-Clamp Terminals | |||||||||||||
16 | 600V AC/600V DC | 16A | 26-14 | 0000000 | 000000 | 3/4 | 0000000 | 000000 | 3/4 | 0000000 | 000000 | 0000000 | 000000 |
Screw Terminals | |||||||||||||
16 | 600V AC/600V DC | 16A | 18-14 | 0000000 | 00000 | 3/4 | 0000000 | 00000 | 3/4 | 0000000 | 00000 | 0000000 | 00000 |
Female | |||||||||||||
Spring-Clamp Terminals | |||||||||||||
16 | 600V AC/600V DC | 16A | 26-14 | 0000000 | 00000 | 3/4 | 0000000 | 00000 | 3/4 | 0000000 | 00000 | 0000000 | 00000 |
Screw Terminals | |||||||||||||
16 | 600V AC/600V DC | 16A | 18-14 | 0000000 | 00000 | 3/4 | 0000000 | 00000 | 3/4 | 0000000 | 00000 | 0000000 | 00000 |
Latching Connectors
Protect connections while maintaining access. The base and hood latch together securely yet can be quickly detached for equipment repair or replacement.
Latching connectors with one latching lever quickly disconnect with one hand. Connectors with two latching levers don’t need as much room to unlatch as connectors with one latching lever and are best for tight spaces.
Latching connectors with cord grips secure cable and protect it from strain. Choose connectors with two cord grips to create a disconnection point on curved or compact equipment that cannot have a panel cutout.
NEMA 4X rated connectors protect against washdowns. NEMA 12 rated connectors resist oil/coolant dripping. IP65 rated connectors protect against dust and rinsing. IP66 rated connectors protect against washdowns.
For technical drawings and 3-D models, click on a part number.
Conduit | Connectors | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | Trade Size | Thread Type | Wire Connection Type | For Wire Gauge | Lg. | Wd. | Ht. | Base Cover Style | Max. Temp., °F | Environmental Rating | Each | |
Powder-Coated Aluminum | ||||||||||||||
16 | 600V AC/600V DC | 16A | 3/4 | NPT | Screw Terminals | 18-14 | 4.5" | 1.7" | 3.6" | Attached | 255° | NEMA 4X, NEMA 12, IP65 | 0000000 | 0000000 |
Conduit | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | Trade Size | Thread Type | Wire Connection Type | For Wire Gauge | Lg. | Wd. | Ht. | Max. Temp., °F | Environmental Rating | Each | |
Powder-Coated Aluminum | |||||||||||||
16 | 600V AC/600V DC | 16A | 3/4 | NPT | Screw Terminals | 18-14 | 4.5" | 1.7" | 3.6" | 255° | NEMA 4X, NEMA 12, IP65 | 0000000 | 0000000 |
Polypropylene Plastic | |||||||||||||
16 | 600V AC/600V DC | 16A | 3/4 | NPT | Spring-Clamp Terminals | 26-14 | 5.3" | 2.3" | 4.2" | 190° | NEMA 4X, NEMA 12, IP66 | 0000000 | 000000 |
Conduit | Connectors | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | Trade Size | Thread Type | Wire Connection Type | For Wire Gauge | Lg. | Wd. | Ht. | Base Cover Style | Max. Temp., °F | Environmental Rating | Each | |
Powder-Coated Aluminum | ||||||||||||||
16 | 600V AC/600V DC | 16A | 3/4 | NPT | Screw Terminals | 18-14 | 4.5" | 1.7" | 2.9" | Attached | 255° | NEMA 4X, NEMA 12, IP65 | 0000000 | 0000000 |
Connectors | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Conduit | Replacement Levers | ||||||||||||||
Number of Poles | Voltage | Current | Trade Size | Thread Type | Wire Connection Type | For Wire Gauge | Lg. | Wd. | Ht. | Max. Temp., °F | Environmental Rating | Each | Each | ||
Powder-Coated Aluminum | |||||||||||||||
16 | 600V AC/600V DC | 16A | 3/4 | NPT | Screw Terminals | 18-14 | 4.5" | 1.7" | 2.9" | 255° | NEMA 4X, NEMA 12, IP65 | 0000000 | 000000 | 0000000 | 000000 |
Polypropylene Plastic | |||||||||||||||
16 | 600V AC/600V DC | 16A | 3/4 | NPT | Spring-Clamp Terminals | 26-14 | 5.3" | 2.3" | 4.6" | 190° | NEMA 4X, NEMA 12, IP66 | 0000000 | 000000 | 000000 | 00 |
Covers (sold separately) protect internal terminals on IP66 rated connectors and maintain their IP rating.
Connection with
Two Latching Levers
Covers (sold separately) protect internal terminals on IP66 rated connectors and maintain their IP rating.
Connection with Two
Latching Levers
Harsh Environment Latching Connectors
Rated NEMA 4X, 12, and IP65, connectors protect against corrosion, washdowns, oil/coolant dripping, and water projected from a nozzle. They have a rubber seal and stainless steel hardware for excellent chemical resistance. Use them to protect connections while maintaining access. The base and hood latch together securely, yet can be quickly detached for equipment repair or replacement.
For technical drawings and 3-D models, click on a part number.
Conduit | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | Trade Size | Thread Type | Connection Gender | Wire Connection Type | For Wire Gauge | Lg. | Wd. | Ht. | Base Cover Style | Max. Temp., °F | Environmental Rating | Each | |
Side Conduit Connection—2 Latching Levers | |||||||||||||||
Powder-Coated Aluminum | |||||||||||||||
16 | 600V AC/600V DC | 16A | 3/4 | NPT | Female | Screw Terminals | 18-14 | 4.5" | 1.7" | 3.6" | Removable | 255° | NEMA 4X, NEMA 12, IP65 | 0000000 | 0000000 |
Servomotor M23 Connectors
with
Mounting Holes
Use these connectors with servomotor, servocontrollers, and servodrives in automated equipment and assembly lines. Rated NEMA 4X, IP67, and IP69K, they resist corrosion and protect against high-pressure, high-temperature washdowns. When mating connectors, the gender, housing thread location, and pole layout must be opposite. Poles are numbered on the face of the connector.
Signal connectors communicate between servocontrollers, servodrives, and servomotors.
For technical drawings and 3-D models, click on a part number.
Clockwise
(12 Pole Shown)
Counterclockwise
(12 Pole Shown)
Connectors | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Low-Current | Replacement Housings | Replacement Inserts | ||||||||||||
No. of Poles | Pole Layout | No. of Poles | Current | For Wire Gauge | Voltage | For Cable OD | OD | For Panel Cutout Dia. | Each | Each | Each | |||
Plug—External Thread | ||||||||||||||
16 | Clockwise | 16 | 8A | 28-17 | 160V AC/160V DC | 0.12"-0.67" | 1" | __ | 0000000 | 000000 | 0000000 | 000000 | 0000000 | 000000 |
Socket—Internal Thread | ||||||||||||||
16 | Counterclockwise | 16 | 8A | 28-17 | 160V AC/160V DC | 0.12"-0.67" | 1" | __ | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
Receptacle—External Thread | ||||||||||||||
16 | Clockwise | 16 | 8A | 28-17 | 160V AC/160V DC | __ | __ | 1" | 0000000 | 00000 | 0000000 | 00000 | 0000000 | 00000 |
Receptacle with 4 Mounting Holes—External Thread | ||||||||||||||