Filter by
Insulated Pin Terminals

A plastic cover insulates the barrel to prevent short-circuiting with nearby wire. These solid pins make it easier to insert stranded wire into screw-clamp connections. Use a crimper (not included) to install wire.
Nylon-insulated terminals are more durable and resist chemicals better than vinyl-insulated terminals.
For technical drawings and 3-D models, click on a part number.
For Wire Gauge | Pin Dia. | Terminal Material | Max. Temp., °F | Max. Voltage | Specifications Met | Insulation Color | Pin Lg. | Pkg. Qty. | Pkg. | |
Vinyl Plastic Insulation | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
26-22 | 0.06" | Tin-Plated Copper | 220° | 600V AC 600V DC | CE Marked | Yellow | 0.39" | 100 | 0000000 | 000000 |
22-18 | 0.08" | Tin-Plated Copper | 220° | 600V AC 600V DC | UL Listed, CSA Certified | Red | 0.35" | 50 | 0000000 | 00000 |
16-14 | 0.08" | Tin-Plated Copper | 220° | 600V AC 600V DC | UL Listed, CSA Certified | Blue | 0.35" | 50 | 0000000 | 00000 |
12-10 | 0.11" | Tin-Plated Copper | 220° | 600V AC 600V DC | UL Listed, CSA Certified | Yellow | 0.41" | 50 | 0000000 | 00000 |
Nylon Plastic Insulation | ||||||||||
26-22 | 0.05" | Tin-Plated Copper | 105° | 600V AC 600V DC | UL Recognized Component, CE Marked | Yellow | 0.39" | 100 | 0000000 | 00000 |
22-18 | 0.08" | Tin-Plated Copper | 220° | 600V AC 600V DC | UL Listed, CSA Certified | Red | 0.41" | 25 | 0000000 | 0000 |
16-14 | 0.08" | Tin-Plated Copper | 220° | 600V AC 600V DC | UL Listed, CSA Certified | Blue | 0.35" | 25 | 0000000 | 0000 |
12-10 | 0.11" | Tin-Plated Copper | 220° | 600V AC 600V DC | UL Listed, CSA Certified | Yellow | 0.35" | 25 | 0000000 | 00000 |