Measure your pipe and fittings to identify their pipe size, thread size, schedule, and thread type. Then, find compatible components.
About Actuated On/Off Valves
More
About Rotating Joints

Rotating joints transfer hot and cold materials from your supply line to a continuously revolving drum, roller, or other rotating equipment.
Pipe size is an industry designation, not the actual size. View information about how to measure pipe size threads.
More
Selecting and Measuring Expansion Joints
For information about selecting pipe size, see Selecting and Measuring Pipe & Fittings.
More
About Gradual On/Off Valves
More
About On/Off Valves
More
Standard-Wall Stainless Steel Threaded Pipe Nipples and Pipe
Designed for low-pressure flow applications, this pipe is also known as Schedule 40.
304 stainless steel pipe offers very good corrosion resistance. 316 stainless steel pipe has excellent corrosion resistance.
Seamless pipe has a smooth interior for unrestricted flow and is stronger than welded pipe.
Welded pipe has a weld bead on the inside.

- For Use With: Natural Gas, Oil, Steam, Water, Air
- Specifications Met: ASTM A733, ASME B1.20.1
- Fittings: Use Class 150 stainless steel
- Flanges: Use Class 150 stainless steel
| Lg. | Construction | Each | |
1/8 Pipe Size | |||
|---|---|---|---|
| 9 1/2" | Seamless | 4830K413 | 00000 |
1/4 Pipe Size | |||
| 9 1/2" | Seamless | 4830K418 | 00000 |
3/8 Pipe Size | |||
| 9 1/2" | Seamless | 4830K424 | 00000 |
1/2 Pipe Size | |||
| 9 1/2" | Welded | 4830K429 | 00000 |
3/4 Pipe Size | |||
| 9 1/2" | Welded | 4830K435 | 00000 |
1 Pipe Size | |||
| 9 1/2" | Welded | 4830K441 | 00000 |
1 1/4 Pipe Size | |||
| 9 1/2" | Welded | 4830K446 | 00000 |
1 1/2 Pipe Size | |||
| 9 1/2" | Welded | 4830K452 | 00000 |
2 Pipe Size | |||
| 9 1/2" | Welded | 4830K457 | 00000 |
3 Pipe Size | |||
| 9 1/2" | Welded | 4830K468 | 00000 |

- For Use With: Natural Gas, Steam, Oil, Water, Air
- Specifications Met: ASTM A733, ASME B1.20.1
- Fittings: Use Class 150 stainless steel
- Flanges: Use Class 150 stainless steel
Standard-Wall Steel Threaded Pipe Nipples and Pipe
Also known as Schedule 40, this pipe is designed for low-pressure applications. Use in noncorrosive applications.
Welded pipe has a weld bead on the inside.

- For Use With: Air, Natural Gas, Oil, Steam, Water
- Specifications Met: ASTM A733, ASME B1.20.1, ASTM A53
- Fittings: Use Class 125 or 150 Iron and Steel

- For Use With: Air, Natural Gas, Oil, Steam, Water
- Specifications Met: ASTM A733, ASME B1.20.1, ASTM A53
- Fittings: Use Class 125 or 150 Iron and Steel
Expansion Joints with Butt-Weld Ends

- For Use With: Air, Natural Gas, Oil, Steam, Water
- Temperature Range: -20° to 800° F
- Maximum Pressure: 150 psi @ 72° F
- Maximum Vacuum: 29 in. of Hg @ 72° F
These joints weld to unthreaded pipe or another butt-weld fitting for a leak-resistant, permanent connection. They reduce stress, vibration, and noise in metal piping systems by providing a point of flexibility to absorb movement.
Distance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| For Pipe OD | Pipe Size | Lg. | Compression | Expansion | Offset | Expansion Joint Type | Butt Weld End Material | Each | |
321 Stainless Steel | |||||||||
| 10 3/4" | 10 | 9 1/2" | 13/16" | 7/16" | 1/16" | Bellow | Steel | 5254K16 | 000000000 |
Stainless Steel One-Way-Flow Rotating Joints

- For Use With: Air, Oil, Steam, Water
- Maximum Temperature:
Oil: 390° F
Steam: 350° F
Water: 300° F - Maximum Pressure:
Air: 300 psi @ 72° F
Oil: 100 psi @ 72° F
Steam: 120 psi @ 350° F
Water: 750 psi @ 72° F - Maximum Vacuum: 25 in. of Hg @ 72° F
These joints have a rotating shaft with threads on one end that connect to a continuously revolving drum, roller, or other rotating equipment. Use them to transfer hot and cold materials from your supply line. Joints are for one-way flow and are meant to be used in pairs—one joint serves as the supply line while the other serves as the return line. Joints are stainless steel for excellent resistance to corrosion caused by fluid flowing through them.
If your drum rotates counterclockwise as you face the connecting end, you should select a rotating joint with right-handed threads. If your drum rotates clockwise as you face the connecting end, you should select a rotating joint with left-handed threads.
Rotating Threads | Stationary Threads | Max. Speed, rpm | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pipe Size | Thread Type | Gender | Pipe Size | Thread Type | Gender | Thread Direction | Air | Water | Oil | Steam | Body Dia. | Lg. | Material | Shaft Material | Each | |
Right-Hand Rotating Threads | ||||||||||||||||
| 2 | NPT | Male | 2 | NPT | Female | Right Hand | 550 | 1,000 | 1,000 | 1,000 | 4 3/8" | 9 1/2" | 300 Series Stainless Steel | Stainless Steel | 9177K572 | 000000000 |
Left-Hand Rotating Threads | ||||||||||||||||
| 2 | NPT | Male | 2 | NPT | Female | Right Hand | 550 | 1,000 | __ | __ | 4 3/8" | 9 1/2" | 300 Series Stainless Steel | Stainless Steel | 9177K571 | 00000000 |
Threaded On/Off Valves
Use these valves in general purpose applications, such as those with water, oil, air, and inert gas.
Bronze valves are stronger and more durable than brass valves for a longer service life. Full-port valves do not restrict flow. Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.

- Valve Type: Ball
- For Use With:
NPT: Argon, Helium, Krypton, Neon, Oil, Steam, Water, Xenon
BSPP and BSPT: Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, Xenon
UN/UNF: Air, Argon, Oil, Steam, Water - Seal Material: PTFE Plastic
Lever handles give you the most leverage for quickly opening and closing valves with minimal effort.
| Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Temperature Range, °F | Port Type | End-to-End Lg. | Ball Material | Each | |
NPT Female × NPT Female | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| 2 | 389 | 600 psi @ 100° F | 150 psi @ 365° F | -20° to 450° | Full | 4 7/8" | Brass | 5754T36 | 0000000 |

- Valve Type: Ball
- For Use With: Air, Argon, Helium, Krypton, Neon, Oil, Steam, Water, Xenon
- Seal Material: PTFE Plastic
Lever handles give you the most leverage for quickly opening and closing valves with minimal effort.
Lockable handles can be fixed in place using a padlock (not included).
| Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Temperature Range, °F | Vacuum Rating, in. of Hg | Port Type | End-to-End Lg. | Ball Material | For Max. Shackle Dia. | Each | |
NPT Female × NPT Female | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 1/2 | 135 | 1000 psi @ 100° F | 200 psi @ 350° F | -20° to 500° | 29.9 | Full | 4 3/4" | 316 Stainless Steel | 1/4" | 8196N53 | 0000000 |
| 2 | 251 | 1000 psi @ 100° F | 200 psi @ 350° F | -20° to 500° | 29.9 | Full | 5 1/16" | 316 Stainless Steel | 1/4" | 8196N54 | 000000 |
High-Pressure Threaded On/Off Valves
Rated for at least three times the pressure of standard threaded valves, these valves are used to start and stop the flow of compressed gas, pressurized water, or steam.
Lever handles are easy to open and close—they give you the most leverage of any handle type. Lockable lever handles can be fixed in place using a padlock (not included). Spring-close lever handles automatically close when you release them, so they’re good where the volume of flow needs to be closely monitored to avoid overflowing and spillage. They’re also called deadman’s handles.
316 stainless steel valves are more corrosion resistant than steel valves.
Standard-port valves slightly restrict flow.

- Valve Type: Ball
- For Use With: See table
- Seal Material: PTFE Plastic
- Specifications Met: See table
| Pipe Size | Max. Pressure | Flow Coefficient (Cv) | Temperature Range, °F | Vacuum Rating, in. of Hg | Port Type | End-to-End Lg. | For Max. Shackle Dia. | For Use With | Specifications Met | Each | |
NPT Female × NPT Female | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 1/2 | 3,000 psi @ 150° F | 95 | -20° to 230° | Not Rated | Standard | 4 9/16" | 9/32" | Water, Oil, Air, Argon, Helium, Krypton, Neon, Xenon | ANSI/FCI 70-2 Class VI | 9786K27 | 0000000 |

- Valve Type: Ball
- For Use With: Oil, Steam, Water
- Seal Material: PTFE Plastic
| Pipe Size | Max. Pressure | Max. Steam Pressure | Flow Coefficient (Cv) | Temperature Range, °F | Vacuum Rating, in. of Hg | Port Type | End-to-End Lg. | Each | |
NPT Female × NPT Female | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| 1 1/2 | 1,500 psi @ 100° F | 150 psi @ 365° F | 84 | -20° to 500° | 29 | Standard | 4 3/8" | 45155K67 | 0000000 |

- Valve Type: Ball
- For Use With: See table
- Seal Material: See table
- Specifications Met: See table
| Pipe Size | Max. Pressure | Flow Coefficient (Cv) | Temperature Range, °F | Vacuum Rating, in. of Hg | Seal Material | Port Type | End-to-End Lg. | For Max. Shackle Dia. | For Use With | Specifications Met | Each | |
NPT Female × NPT Female | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 1/2 | 3,000 psi @ 150° F | 95 | -40° to 230° | Not Rated | PTFE Plastic | Standard | 4 9/16" | 9/32" | Water, Oil, Air, Argon, Helium, Krypton, Neon, Xenon | ANSI/FCI 70-2 Class VI | 47275K47 | 0000000 |

- Valve Type: Ball
- For Use With: Oil, Steam, Water
- Seal Material: PTFE Plastic
| Pipe Size | Max. Pressure | Max. Steam Pressure | Flow Coefficient (Cv) | Temperature Range, °F | Vacuum Rating, in. of Hg | Port Type | End-to-End Lg. | Each | |
NPT Female × NPT Female | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| 1 1/2 | 1,500 psi @ 100° F | 150 psi @ 365° F | 84 | -20° to 500° | 29 | Standard | 4 3/8" | 45155K57 | 0000000 |
Threaded On/Off Valves for Fuel

- Valve Type: Ball
- For Use With: Diesel Fuel, Fuel Oil, Gasoline, Kerosene
- Specifications Met: See table
Protect personnel and equipment in the presence of diesel fuel, fuel oil, gasoline, and kerosene. Fire-tested to meet American Petroleum Institute (API) 607, these valves are designed to securely isolate fluid and prevent the spread of fire. They have a lockable handle that can be fixed in place using a padlock (not included).
316 stainless steel valves are more corrosion resistant than steel valves.
Standard-port valves slightly restrict flow.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
| Pipe Size | Flow Coefficient (Cv) | Max. Pressure | Temp. Range, °F | Vacuum Rating, in. of Hg | Port Type | End-to-End Lg. | For Max. Shackle Dia. | Specifications Met | Each | |
Steel Body—PTFE Plastic Seal | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|
NPT Female × NPT Female | ||||||||||
| 2 | 81 | 2000 psi @ 250° F | -20° to 450° | 26 | Standard | 4 5/16" | 1/4" | American Petroleum Institute Standard 607 - Edition 4 | 4024T78 | 0000000 |
316 Stainless Steel Body—PTFE Plastic Seal | ||||||||||
NPT Female × NPT Female | ||||||||||
| 2 | 81 | 2000 psi @ 250° F | -20° to 450° | 26 | Standard | 4 5/16" | 1/4" | American Petroleum Institute Standard 607 - Edition 4 | 4040T68 | 000000 |
Flanged On/Off Valves for Chemicals
Bolt these valves to ANSI flanges—they meet ASME dimensional standards. They have a plastic body and a seal that withstand aggressive and corrosive solutions in chemical-processing applications.
Glass-filled vinyl ester valves stand up to a wide variety of harsh acids and solvents. You can rely on them for repeated use, changes in pressure and flow rate, and hot and cold conditions.
Valves with a lockable lever handle can be fixed in place with a padlock (not included). They give you more leverage than short lever handles, so you can quickly open and close the valve with minimal effort.
Standard-port valves slightly restrict flow.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.

- Valve Type: Ball
- For Use With: Citric Acid, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Fuel Oil, Gasoline, Hydrochloric Acid, Isopropyl Alcohol, Kerosene, Methanol, Methyl Ethyl Ketone, Mineral Spirits, Oil, Phosphoric Acid, Salt Water, Soap Solutions, Toluene, Water, Xylene
- Ball Material: Glass-Filled Vinyl Ester
- Seal Material: PTFE Plastic
- Seat Material: PTFE Plastic
- Packing Material: PTFE Plastic
- For Flange Specifications Met: ASME B16.5, ASME B16.10
Bolts | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pipe Size | Pressure Class | Flange OD | Circle Dia. | No. of Holes | Hole Dia. | Included | Flow Coefficient (Cv) | Max. Pressure | Temperature Range, °F | Vacuum Rating, in. of Hg | Port Type | End-to-End Lg. | For Max. Shackle Dia. | Each | |
Flanged × Flanged | |||||||||||||||
| 1 1/2 | 150 | 5" | 3 7/8" | 4 | 5/8" | No | 115 | 250 psi @ 100° F | -50° to 215° | 29.9 | Standard | 6 1/2" | 1/4" | 5927T112 | 0000000 |
Threaded Gradual On/Off Valves for Boiler Blow-Off
Prevent boiler scale deposits and sediment buildup with these valves that meet ASME standards for boiler drainage applications. Also known as gate valves, they gradually open and close to prevent system damage from suddenly starting or stopping flow.
Valves with a wheel handle open and close with multiple turns, providing more controlled, shock-resistant flow than valves with a lever handle.
Valves with a nonrising stem fit well in low-clearance places since the handle doesn’t move up when the valve opens.
Cast iron valves absorb vibration, reducing noise from your industrial boiler.
Use repair kits to replace worn-out seals.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.

- Valve Type: Gate
- For Use With: Water
- Packing Material: EPDM Rubber
- Specifications Met: ASME B16.34, ASME B16.5, ASME B31.1, ASME BPVC.I
Air-Driven On/Off Valves for Fuel


- Valve Type: Butterfly
- For Use With: Oil, Diesel Fuel, Ethylene Glycol, Kerosene, Butane, Fuel Oil, Gasoline, Natural Gas, Propane
- Seal Material : Viton® Fluoroelastomer Rubber
- Specifications Met: API 609, MSS-SP-67
Use these valves to safely transfer fuel and oil. They operate on compressed air to automatically start and stop flow faster than motor-driven valves. You must control the air to the actuator using either the included electric pilot valve or a manual on/off valve (not included). These valves don’t require a minimum pressure drop between the inlet and outlet for operation.
The actuator is directly mounted to the valve body to minimize movement and reduce wear. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. The manual override allows you to operate the valve during power outages.
All valves are lug style; their hole pattern matches ANSI flanges of the same pipe size. They can be sandwiched between two flanges, or bolt them directly to a single flange for servicing one end of the pipeline without depressurizing the other side.
Single-acting actuators only require air pressure to open the valve; they automatically spring closed when the air turns off. These valves are normally closed unless actuated. Double-acting actuators require air pressure to open and close the valve. Once actuated, these valves remain actuated until air pressure is applied, so they do not have a valve starting position.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Bolts | Air | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pipe Size | Flange OD | No. of Holes | Hole Size | Included | Circle Dia. | Flow Coefficient (Cv) | Max. Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Connection | Pressure Range, psi | Each | |
Ductile Iron Body with Screw Terminals | |||||||||||||||
Single Acting: Air-to-Open, Spring Return (Normally Closed)—120V AC | |||||||||||||||
| 3 | 7 1/2" | 4 | 5/8" | No | 6" | 300 | 250 psi @ 100° F | Zero Pressure Drop | 10° to 350° | 1 3/4" | 16 9/16" | 1/4 NPT Female | 40 to 115 | 2529N16 | 0000000 |
Double Acting: Air-to-Open, Air-to-Close—120V AC | |||||||||||||||
| 6 | 11" | 8 | 3/4" | No | 9 1/2" | 1,620 | 250 psi @ 100° F | Zero Pressure Drop | 10° to 350° | 2 3/16" | 20 9/16" | 1/4 NPT Female | 40 to 115 | 2529N14 | 00000000 |
Flanged Air-Driven On/Off Valves for Chemicals

- Valve Type: Ball
- For Use With: Water, Oil, Air, Natural Gas, Propane, Butane, Acetone, Argon, Carbon Dioxide, Deionized Water, Diesel Fuel, Ethanol, Ethylene Glycol, Fuel Oil, Gasoline, Helium, Kerosene, Methanol, Methyl Ethyl Ketone, Mineral Spirits, Neon, Nitric Acid, Nitrogen, Oxygen, Salt Water, Soap Solutions, Steam, Xenon, Citric Acid, Krypton
- Ball Material: 316 Stainless Steel
- Seal Material : PTFE Plastic
- Seat Material: PTFE Plastic
- Actuator Housing Material: Aluminum
- Specifications Met: ASME B16.34
A 316 stainless steel body and a PTFE seal stand up to aggressive and corrosive solutions in chemical-processing applications. Their ball-valve design allows these valves to handle at least three times the flow of standard flanged valves. For faster actuation than motor-driven valves, they operate on compressed air. You must control the air to the actuator using either the included electric pilot valve or a manual on/off valve (not included). These valves automatically start and stop flow and don't require a minimum pressure drop between the inlet and outlet for operation.
Valves are full port, so they do not restrict flow. The actuator is secured to the valve body with a bracket for easy disassembly, maintenance, and repair. A visual flow indicator on the top of the actuator shows whether the valve is open or closed. The manual override allows you to operate the valve during power outages.
Double-acting actuators require air pressure to open and close the valve. Once actuated, these valves remain actuated until air pressure is applied to close them, so they do not have a valve starting position.
Flow coefficient (Cv) is the amount of water (in gallons per minute) at 60° F that will flow through a fully open valve with a difference of 1 psi between the inlet and the outlet.
Bolts | Air | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pipe Size | Gender | Flange OD | No. of Holes | Hole Size | Included | Circle Dia. | Flow Coefficient (Cv) | Max. Pressure | Max. Steam Pressure | Pressure Drop | Temp. Range, °F | Valve Lg. | O'all Ht. | Connection | Pressure Range, psi | Each | |
316 Stainless Steel Body with Screw Terminals | |||||||||||||||||
Double Acting: Air-to-Close, Air-to-Open—120V AC | |||||||||||||||||
| 3 | Female | 7 1/2" | 4 | 0.551" | No | 6" | 1,013 | 275 psi @ 100° F | 100 psi @ 338° F | Zero Pressure Drop | 0° to 365° | 4 13/16" | 15 1/4" | 1/4 NPT Female | 40 to 115 | 2538N12 | 000000000 |