Fuse Type Fuse Type | Show |
|---|
![]() | Plug Base |
Fuse Type Fuse Type | Hide |
|---|
| Cartridge | Glass |
![]() | |
| Ceramic | Automotive |
| European | Thermal |
![]() | |
| Branch Circuit | Inline |
![]() | |
| Plug Base |
Protection Type Protection Type |
|---|
|
Voltage Voltage |
|---|
|
Breakthrough Current Breakthrough Current |
|---|
|
Specifications Met Specifications Met |
|---|
Blown Fuse Indicator Blown Fuse Indicator |
|---|
|
DFARS (Defense Acquisition Regulations Supplement) DFARS (Defense AcquisitionRegulations Supplement) |
|---|
REACH (Registration, Evaluation, Authorization and Restriction of Chemicals) REACH (Registration,Evaluation, Authorization and Restriction of Chemicals) |
|---|
|
RoHS (Restriction of Hazardous Substances) RoHS (Restriction ofHazardous Substances) |
|---|
|
Don’t see the fuse you need? Just tell us what you’re looking for and we’ll get it for you.
About Fuses
More
Time-Delay Plug Base Fuses


Able to withstand current overload for a short time, these fuses will not open when exposed to harmless temporary surges, such as during equipment start-up. They are designed to fit into a socket on a panel; match the fuse to your panel socket by the manufacturer equivalent.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
Type GSL and S fuses have a non-interchangeable base to prevent the wrong size fuse from being used.
Type GTL, TL, and TLO fuses can be used in motor applications.
For technical drawings and 3-D models, click on a part number.
| Current, A | Voltage | Breakthrough Current | No. of Elements | Plug Base Style | Specifications Met | Pkg. Qty. | Plug Base Fuse Type | Pkg. | |
Manufacturer Equivalent: GSL, S | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| 15 | 125V AC | 10,000 A @ 125 V AC | 2 | __ | UL Listed | 4 | Type S | 0000000 | 000000 |
| 20 | 125V AC | 10,000 A @ 125 V AC | 2 | __ | UL Listed | 4 | Type S | 0000000 | 00000 |
| 30 | 125V AC | 10,000 A @ 125 V AC | 2 | __ | UL Listed | 4 | Type S | 0000000 | 00000 |
Manufacturer Equivalent: GTL, TL, TLO | |||||||||
| 15 | 125V AC | 10,000 A @ 125 V AC | 1 | Edison | UL Listed | 4 | __ | 0000000 | 00000 |
| 20 | 125V AC | 10,000 A @ 125 V AC | 1 | Edison | UL Listed | 4 | __ | 0000000 | 00000 |
| 30 | 125V AC | 10,000 A @ 125 V AC | 1 | Edison | UL Listed | 4 | __ | 0000000 | 00000 |
Long-Time-Delay Plug Base Fuses

These fuses have a longer time delay than standard time-delay fuses. Use them in motor applications where the motor is cycled on and off frequently. Also known as Edison-type fuses, they are designed to fit into a socket on a panel; match the fuse to your panel socket by the manufacturer equivalent.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
Fast-Acting Plug Base Fuses

These fuses open circuits quickly when surges are detected. Also known as Edison-type fuses, they are designed to fit into a socket on a panel; match the fuse to your panel socket by the manufacturer equivalent.
Breakthrough current, labeled on the fuse as IR, is the maximum current that a fuse can safely stop in the event of a short circuit.
For technical drawings and 3-D models, click on a part number.