Because they tightly thread to M12 connections, these connectors won’t let contaminants in or come loose from vibration in rugged industrial environments and automated systems as they send power and signal or just power to your equipment. Their poles and keyways adhere to standard coding layouts, reducing the chance you’ll mismatch connectors.
A- and C-coded connectors send both power and signal, while K-, L-, S-, and T-coded connectors only send power. Choose A-coded connectors for AC and DC sensors, actuators, motors, light curtains, and other devices. They’re often used to connect equipment to IO Link controllers and within Profibus, DeviceNet, and other fieldbus systems. Connectors with a snap-on wire connection pierce the wire’s insulation, so you don’t need to strip it.IP67 and IP68 rated connectors can withstand brief submersion. Add caps to protect connectors and maintain their IP and NEMA ratings when not in use.
Note: Sockets and female receptacles may have extra holes on their face that are not used.
For technical drawings and 3-D models, click on a part number.
Housing Thread | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Coding | Face Dia. | Voltage | Current | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Type | Max. Temp., °F | Environmental Rating | Each | |
5 | A | 0.3" | 50V AC/50V DC | 4A | 22-20 | 0.19"-0.23" | Nylon Plastic | M12 | 1 | Metric | 185° | IP67 | 0000000 | 000000 |
Housing Thread | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Coding | Voltage | Current | Face Dia. | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Type | Max. Temp., °F | Environmental Rating | Each | |
5 | A | 50V AC/50V DC | 4A | 0.3" | 22-20 | 0.19"-0.23" | Nylon Plastic | M12 | 1 | Metric | 185° | IP67 | 0000000 | 000000 |
Shielded Micro M12 Screw-Together Connectors
Block signal interference from nearby devices, such as motors and transmitters, while maintaining a strong, stable connection for M12 threads. The shielding on these connectors maintains signal integrity and minimizes signal loss between equipment. The threaded housing creates a secure connection that withstands the shaking and vibrating of industrial automation.
A-coded, these connectors are often used to connect equipment to IO Link controllers and devices within Profibus, DeviceNet, and other fieldbus systems. They work with both AC and DC devices such as sensors, motors, and light curtains. Poles and keyways on their face adhere to standard coding layouts to reduce the chance you’ll mismatch connections.
Snap-on connectors pierce your wire’s insulation, so you don’t need to strip it.
All meet IP ratings when either mated or capped. IP65 rated connectors seal out dust and water from low-pressure washdowns. IP67 rated connectors are protected from dust and temporary submersion.
Add caps to protect connectors and maintain their IP ratings when not in use.
Note: They may have extra holes on the face that are not used.
For technical drawings and 3-D models, click on a part number.
Housing Thread | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Coding | Face Dia. | Voltage | Current | For Wire Gauge | For Cable OD | Housing Material | Size | Pitch, mm | Type | Temp. Range, °F | Environmental Rating | Each | |
4 | A | 0.3" | 50V AC/50V DC | 4A | 24-22 | 0.18" - 0.35" | Nickel-Plated Brass | M12 | 1 | Metric | -40° to 185° | IP65, IP67 | 0000000 | 000000 |
For Thread Size | Material | Each | |
For Sockets with Internal Threads | |||
---|---|---|---|
M12 | Anodized Aluminum | 0000000 | 000000 |
Compact Build-Your-Own Latching Connectors
Build a connector that fits in tight spaces by combining male and female inserts and then pairing them with any base and hood of the same material. Use them to protect connections while maintaining access. The base and hood latch together securely, yet can be quickly detached for equipment repair or replacement. Once assembled, they’re rated NEMA 4X for protection against washdowns and NEMA 12 to resist oil/coolant dripping.
Insert sets include one male plug and one female socket.
For technical drawings and 3-D models, click on a part number.
Number of Poles | Voltage | Current | For Wire Gauge | Insert Material | Specifications Met | Each | |
Female Insert | |||||||
---|---|---|---|---|---|---|---|
6 | 50V AC/50V DC | 10A | 18-16 | Polyamide Plastic | UL Recognized Component, UL 94 V-0, CSA Certified | 0000000 | 000000 |
Male Insert | |||||||
6 | 50V AC/50V DC | 10A | 18-16 | Polyamide Plastic | UL Recognized Component, UL 94 V-0, CSA Certified | 0000000 | 00000 |
Insert Set | |||||||
6 | 50V AC/50V DC | 10A | 18-16 | Polyamide Plastic | UL Recognized Component, UL 94 V-0, CSA Certified | 0000000 | 00000 |
Weatherproof Molex Compact Connector Sets
A sealed polystyrene plastic housing protects connectors from weather. All come assembled with wire leads already installed so they can be quickly added to existing wiring systems. Each set includes one male plug and one female socket. A locking tab keeps them securely in place when mated.
For technical drawings and 3-D models, click on a part number.
Pin | Wire Lead | Mated Housing | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Number of Poles | Voltage | Current | Wd. | Dp. | Gauge | Lg. | Color | Housing Material | Lg. | Wd. | Ht. | Max. Temp., °F | Environmental Rating | Specifications Met | Each | |
Plug × Socket | ||||||||||||||||
Molex MX150L | ||||||||||||||||
2 | 50V DC | 10A | 0.059" | 0.031" | 18 | 48" | Black | Polystyrene Plastic | 2.85" | 0.96" | 0.93" | 255° | IP67 | SAE J1128 | 0000000 | 000000 |
2 | 50V DC | 15A | 0.059" | 0.031" | 14 | 48" | Black | Polystyrene Plastic | 2.85" | 0.96" | 0.93" | 255° | IP67 | SAE J1128 | 0000000 | 00000 |
4 | 50V DC | 7A | 0.059" | 0.031" | 18 | 48" | Black | Polystyrene Plastic | 2.85" | 0.96" | 1.18" | 255° | IP67 | SAE J1128 | 0000000 | 00000 |
6 | 50V DC | 7A | 0.059" | 0.031" | 18 | 48" | Black | Polystyrene Plastic | 2.85" | 1.2" | 1.18" | 255° | IP67 | SAE J1128 | 0000000 | 00000 |
6 | 50V DC | 13A | 0.059" | 0.031" | 14 | 48" | Black | Polystyrene Plastic | 2.85" | 1.2" | 1.18" | 255° | IP67 | SAE J1128 | 0000000 | 00000 |
8 | 50V DC | 7A | 0.059" | 0.031" | 18 | 48" | Black | Polystyrene Plastic | 2.85" | 1.43" | 1.18" | 255° | IP67 | SAE J1128 | 0000000 | 00000 |
10 | 50V DC | 7A | 0.059" | 0.031" | 18 | 48" | Black | Polystyrene Plastic | 2.85" | 1.66" | 1.18" | 255° | IP67 | SAE J1128 | 0000000 | 00000 |
10 | 50V DC | 13A | 0.059" | 0.031" | 14 | 48" | Black | Polystyrene Plastic | 2.85" | 1.66" | 1.18" | 255° | IP67 | SAE J1128 | 0000000 | 000000 |
12 | 50V DC | 13A | 0.059" | 0.031" | 14 | 48" | Black | Polystyrene Plastic | 2.85" | 1.89" | 1.18" | 255° | IP67 | SAE J1128 | 0000000 | 000000 |
16 | 50V DC | 7A | 0.059" | 0.031" | 18 | 48" | Black | Polystyrene Plastic | 2.85" | 2.35" | 1.18" | 255° | IP67 | SAE J1128 | 0000000 | 000000 |
Low-Voltage High-Temperature Wire
- Use for ovens and furnaces, panel and equipment (hook-up)
- Wire with FEP Plastic Insulation: Flexible
Wire with Silicone Rubber Insulation: Ultra Flexible - Temperature Range:
Wire with FEP Plastic Insulation: -239° to 390° F
Wire with Silicone Rubber Insulation: -100° to 400° F
Rated to 50 volts AC/DC, this wire is often used in small electronics and robotics. It’s also known as hook-up wire.
Wire with FEP insulation is chemical resistant.
Wire with silicone rubber insulation is ultra-flexible for use in applications that require tight turns. It also withstands moisture.
Silver-plated wire is stronger and more corrosion resistant than bare wire.
Wire Ga. | Strand Count | Current | OD | Wire Material | Choose an Outer Insulation Color | 10 ft. | 25 ft. | 50 ft. | |
Stranded Wire with FEP Plastic Insulation | |||||||||
---|---|---|---|---|---|---|---|---|---|
50V AC/50V DC | |||||||||
36 | 25/50 | 0.1 A @ 86° F | 0.01" | Silver-Plated Copper | 000000 | ||||
29 | 51/46 | 0.5 A @ 86° F | 0.02" | Silver-Plated Copper | 000000 | ||||
26 | 66/44 | 1 A @ 86° F | 0.02" | Silver-Plated Copper | 000000 | ||||
Stranded Wire with Silicone Rubber Insulation | |||||||||
50V AC/50V DC | |||||||||
36 | 25/50 | 0.1 A @ 86° F | 0.02" | Bare Copper | 000000 | ||||
29 | 51/46 | 0.5 A @ 86° F | 0.03" | Bare Copper | 000000 | ||||
26 | 66/44 | 1 A @ 86° F | 0.04" | Bare Copper | 000000 |