McMaster-Carr logo
    Filter by
    Ethernet Cable Category
    Industrial Info Compare
    American Wire Gauge (AWG)
    Industrial Info Compare
    Attribute Image
    Transmission Frequency
    Minimum Temperature
    Housing Thread Size
    Industrial Info Compare
    Number of Poles
    Shield Type
    U.S.–Mexico–Canada Agreement (USMCA) Qualifying
    Maximum Temperature
    DFARS Specialty Metals
    Export Control Classification Number (ECCN)
    Industrial Info Snippet
    Signal Type
    Electrical Connection Coding
    Industrial Info Compare
    Enclosure Rating
    Industrial Info Compare
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    15 Products

    Single Pair Ethernet Cords

    These cords contain a single pair of twisted wires, making them lighter and more flexible than other Ethernet cords. They’re good for transportation, robotics, and automation applications. Cords have a metal locking tab to create a more secure connection than cords with RJ45 connectors, and are easier to install than coaxial cords and cords with M12 connectors. They transmit power as well as data, making them useful in places without an easily accessible power supply. These cords are shielded to block out signal interference from nearby devices.
    Cords meet IEEE standards for data transmission speeds and protocols and EN 60811-404 for resistance to mineral oil. They’re compliant with IEC 60332-1-2 for flame retardancy and IEC 63171-6 for single pair Ethernet cord dimensions and compatibility.
    Straight T1 Industrial Plug × Straight T1 Industrial Plug
    Image of Product. Front orientation. Ethernet Cords. Single Pair Ethernet Cords.
    Lg.,
    ft.
    Transmission
    Freq., MHz
    Voltage,
    V DC
    Current,
    amp
    AWG
    Cord
    OD
    Shielding
    Shield
    Type
    Temp. Range,
    ° F
    Certification
    Enclosure
    Rating
    Specs. Met
    Flammability
    Rating
    Features
    Color
    Each
     
    Single-Pair Ethernet Cable
    4960060426
    0.17"Shielded
    Braid, Foil-40 to 175UL Listed
    IP20
    EN 60811-404, IEC 63171-6, IEEE 802.3bp, IEEE 802.3bu, IEEE 802.3bw, IEEE 802.3cgIEC 60332-1-2Locking Tab, Power over Data Line (PoDL)Yellow3748N17000000
     

    Duct-Rated Ethernet Cords

    Also known as plenum-rated cords, these CMP ethernet cords have flame-resistant, low-smoke insulation and can be used without conduit in ductwork and above a drop ceiling. The RJ45 plugs on each end connect to Ethernet equipment, such as computers, IO modules, and programmable logic controllers (PLCs). Not only do these cords transmit data, but they also power devices that are Power over Ethernet (PoE) compatible. They’re often used with EtherNet/IP, Profinet, and EtherCAT systems.
    Straight RJ45 Plug × Straight RJ45 Plug
    Image of Product. Front orientation. Ethernet Cords. Duct-Rated Ethernet Cords.
    Lg.,
    ft.
    Transmission
    Freq., MHz
    AWG
    Cord
    OD
    Cable
    Designation
    Shielding
    Temp. Range,
    ° F
    Color
    Each
     
    Category 6 Ethernet Cable
    1555023
    0.28"CMP
    Unshielded
    35 to 140Black5591N11000000
    2555023
    0.28"CMP
    Unshielded
    35 to 140Black5591N1200000
     

    Ethernet Cords with M8 Connectors

    Unlike the RJ45 ends on traditional Ethernet cords, the threaded M8 ends on these cords keep contaminants out and resist coming loose from vibration. They are often used with sensors, switches, I/O modules, and computers. Braided shielding protects against signal interference. Insulated with polyurethane rubber, these cords bend easily, so they are ideal for applications that require continuous flexibility such as robotics. They also resist oil. When mated, they are IP67 rated for protection from dust and temporary submersion.
    Straight M8 Plug × Wire Leads—External Thread
    Image of Product. Front orientation. Ethernet Cords. Ethernet Cords with M8 Connectors, Plug, Straight End.
    Image of Specification. A Code. Front orientation. External Thread. Ethernet Cords with M8 Connectors.

    A Code

    A Code—A-coded cords work with EtherCAT connections that have the same pole configuration.
    Cord
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    Face
    Dia.
    Voltage
    Current,
    amp
    Wire Lead
    AWG
    OD
    Insulation
    Material
    Cable Lead
    Lg., ft.
    Shielding
    Shield
    Type
    Temp. Range,
    ° F
    Enclosure
    Rating
    Certification
    Each
    A-Coded—Category 5e Ethernet Cable
    41000.27"30V AC/30V DC426
    0.19"Polyurethane Rubber
    1.5Shielded
    Braid, Foil0 to 120IP67
    UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified
    6115N26000000
    41000.27"30V AC/30V DC426
    0.19"Polyurethane Rubber
    3Shielded
    Braid, Foil0 to 120IP67
    UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified
    6115N1700000
    41000.27"30V AC/30V DC426
    0.19"Polyurethane Rubber
    6.5Shielded
    Braid, Foil0 to 120IP67
    UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified
    6115N1800000
    41000.27"30V AC/30V DC426
    0.19"Polyurethane Rubber
    16Shielded
    Braid, Foil0 to 120IP67
    UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified
    6115N1900000
    41000.27"30V AC/30V DC426
    0.19"Polyurethane Rubber
    32.5Shielded
    Braid, Foil0 to 120IP67
    UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified
    6115N21000000
     
    90° Elbow M8 Plug × Wire Leads—External Thread
    Image of Product. Front orientation. Ethernet Cords. Ethernet Cords with M8 Connectors, Plug, 90° Elbow End.
    Image of Specification. A Code. Front orientation. External Thread. Ethernet Cords with M8 Connectors.

    A Code

    A Code—A-coded cords work with EtherCAT connections that have the same pole configuration.
    Cord
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    Face
    Dia.
    Voltage
    Current,
    amp
    Wire Lead
    AWG
    OD
    Insulation
    Material
    Cable Lead
    Lg., ft.
    Shielding
    Shield
    Type
    Temp. Range,
    ° F
    Enclosure
    Rating
    Certification
    Each
    A-Coded—Category 5e Ethernet Cable
    41000.27"30V AC/30V DC426
    0.19"Polyurethane Rubber
    3Shielded
    Braid, Foil0 to 120IP67
    UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified
    6115N22000000
    41000.27"30V AC/30V DC426
    0.19"Polyurethane Rubber
    6.5Shielded
    Braid, Foil0 to 120IP67
    UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified
    6115N2300000
    41000.27"30V AC/30V DC426
    0.19"Polyurethane Rubber
    16Shielded
    Braid, Foil0 to 120IP67
    UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified
    6115N2400000
    41000.27"30V AC/30V DC426
    0.19"Polyurethane Rubber
    32.5Shielded
    Braid, Foil0 to 120IP67
    UL Listed, C-UL Listed, CE Marked, CSA-US Certified, CSA Certified
    6115N25000000
     

    Ethernet Cords with M12 Connectors

    The M12 threaded ends on these cords seal out contaminants and resist coming loose from vibration better than the RJ45 ends on traditional Ethernet cords. Use them in tough, rugged environments to send high-speed data between sensors, switches, servers, computers, and PLCs not protected by control panels. These cords can power devices as they send data, as long as devices are Power over Ethernet (PoE) compatible. They are often used within Ethernet/IP, Profinet, and EtherCat systems. Their poles and keyways adhere to standard coding layouts, reducing the chance you’ll mismatch connections.
    All cords are backward compatible, so they work in networks that meet the same or lower ethernet cable category. For example, a Category 6 cord will work in a Category 5 network, but it will only run at the Category 5 speed.
    With either TPE or polyurethane rubber insulation, all cords stand up to harsh factory conditions, chemicals, and UV rays. All are also highly flexible, so they’re good for jobs with continuous motion, such as robotics.
    When mated, all cords are IP67 rated to protect against dust and temporary submersion.
    Straight M12 Plug × Wire Leads—External Thread
    Image of Product. Front orientation. Ethernet Cords. Ethernet Cords with M12 Connectors, Straight End, Plug, Y Code.
    Image of Specification. Y-Code Male. Front orientation. Y Code. Ethernet Cords with M12 Connectors.

    Y Code

    Y-Code Male

    Polyurethane Rubber Cord Insulation—Oil-resistant polyurethane-rubber-insulated cords are free of halogen, so they’re safer than most plastic as they won’t release toxic fumes or corrode metal.
    IP65 Enclosure Rating—IP65-rated cords stand up to washdowns.
    Cord
    3 ft. Long
    Cable Lead
    16 ft. Long
    Cable Lead
    No. of
    Poles
    Transmission
    Speed, Mbit/s
    OD
    Insulation
    Material
    Wire Lead AWG (No.
    of Wires)
    Shielding
    Housing Material
    Housing Thread
    Size
    Temp. Range,
    ° F
    Certification
    Enclosure
    Rating
    Each
    Each
    Y-Coded—Category 5e Ethernet Cable
    81000.32"Polyurethane Rubber
    20 (4); 26 (4)Shielded
    Nickel-Plated Zinc AlloyM12 × 1 mm-10 to 155UL Listed, C-UL Listed
    IP65, IP67
    8256T680000008256T690000000
     
    Caps
    back to top