    59 Products

    Differential Pressure Switches for Liquids

    Image of Product. Front orientation. Differential Pressure Switches. Differential Pressure Switches for Liquids.
    Detect the difference in pressure between two points. For instance, these switches can indicate a filter is clogged in a pump or cooling system. When the differential pressure reaches your setpoint, they turn equipment on and off, activate automated controls, or signal alarms. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on or from on to off. All meet at least one safety standard.
    NEMA 1 Enclosure Rating—NEMA 1 rated switches should only be used indoors.
    NEMA 4 Enclosure Rating—NEMA 4 rated switches can be used in dirty and wet areas exposed to washdowns and weather.
    NEMA 4X Enclosure Rating—NEMA 4X rated switches can be used in dirty and wet areas exposed to washdowns and weather. They also have increased protection against corrosion, similar to 304 stainless steel.
    NEMA 13 Enclosure Rating— NEMA 13 rated switches can be used in dirty, wet, and oily areas.
    IP66 Enclosure Rating— IP66 rated switches protect against dust and washdowns.
    Pressure Set Point Range
    Approx. Difference Between Set
    Point and Reset Point
    Max. Input
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Certification
    Each
    Screw Terminal—1/4 NPT Female Pipe Connection
     
    NEMA 1 Enclosure Rating
    1 psi to 10 psi0.75 psi150±1%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 200BrassDiesel Fuel, Gasoline, Hydraulic Fluid (Petroleum Based), WaterC-UL Listed, CE Marked, UL Listed
    46845K730000000
    4 psi to 45 psi1 psi150±1%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 200BrassDiesel Fuel, Gasoline, Hydraulic Fluid (Petroleum Based), WaterC-UL Listed, CE Marked, UL Listed
    46845K74000000
     
    NEMA 4 Enclosure Rating
    1 psi to 10 psi0.75 psi150±1%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 200BrassDiesel Fuel, Gasoline, Hydraulic Fluid (Petroleum Based), WaterC-UL Listed, CE Marked, UL Listed
    46845K81000000
    4 psi to 45 psi1 psi150±1%5 amp @ 125V AC
    5 amp @ 250V AC
    0 to 200BrassDiesel Fuel, Gasoline, Hydraulic Fluid (Petroleum Based), WaterC-UL Listed, CE Marked, UL Listed
    46845K82000000
     
    NEMA 4X Enclosure Rating, NEMA 13 Enclosure Rating, IP66 Enclosure Rating
    4.5 in. H₂O to 30 in. H₂O2 in. H₂O5.4±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 240V DC
    0 to 150SteelDiesel Fuel, Gasoline, Hydraulic Fluid, Oil, WaterC-UL Listed, CE Marked, CSA Certified, CSA-US Certified, FM Approved, UL Listed
    4518N11000000
    9 in. H₂O to 60 in. H₂O2.5 in. H₂O5.4±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 240V DC
    0 to 150SteelDiesel Fuel, Gasoline, Hydraulic Fluid, Oil, WaterC-UL Listed, CE Marked, CSA Certified, CSA-US Certified, FM Approved, UL Listed
    4518N12000000
    15 in. H₂O to 100 in. H₂O4 in. H₂O5.4±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 240V DC
    0 to 150SteelDiesel Fuel, Gasoline, Hydraulic Fluid, Oil, WaterC-UL Listed, CE Marked, CSA Certified, CSA-US Certified, FM Approved, UL Listed
    4518N13000000
    22.5 in. H₂O to 150 in. H₂O6.5 in. H₂O5.4±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 240V DC
    0 to 150SteelDiesel Fuel, Gasoline, Hydraulic Fluid, Oil, WaterC-UL Listed, CE Marked, CSA Certified, CSA-US Certified, FM Approved, UL Listed
    4518N14000000
    2.25 psi to 15 psi3.5 psi500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 240V DC
    0 to 150BrassDiesel Fuel, Gasoline, Hydraulic Fluid, Oil, WaterC-UL Listed, CE Marked, CSA Certified, CSA-US Certified, FM Approved, UL Listed
    4518N15000000
    4.5 psi to 30 psi3.5 psi500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 240V DC
    0 to 150BrassDiesel Fuel, Gasoline, Hydraulic Fluid, Oil, WaterC-UL Listed, CE Marked, CSA Certified, CSA-US Certified, FM Approved, UL Listed
    4518N16000000
    9 psi to 60 psi4.5 psi500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 240V DC
    0 to 150BrassDiesel Fuel, Gasoline, Hydraulic Fluid, Oil, WaterC-UL Listed, CE Marked, CSA Certified, CSA-US Certified, FM Approved, UL Listed
    4518N17000000
    15 psi to 100 psi15.5 psi1,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    6 amp @ 30V DC
    500 mA @ 125V DC
    250 mA @ 240V DC
    0 to 150BrassDiesel Fuel, Gasoline, Hydraulic Fluid, Oil, WaterC-UL Listed, CE Marked, CSA Certified, CSA-US Certified, FM Approved, UL Listed
    4518N18000000
     

    Differential Pressure Switches for Air

    Image of Product. Front orientation. Differential Pressure Switches. Differential Pressure Switches for Air, Connects to Tube.
    Image of Product. Front orientation. Differential Pressure Switches. Differential Pressure Switches for Air, Connects to Pipe.

    Connects to

    Tube

    Connects to Pipe

    Often used with ovens, dryers, and HVAC systems, these switches detect small differences in air pressure to indicate a filter is clogged or help you maintain a certain air pressure. When the differential pressure reaches your setpoint, these switches can turn equipment on and off, activate automated controls, or signal alarms. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on or from on to off. All meet at least one safety standard.
    When measuring pressure in ductwork, pair them with a static pressure probe.
    IP54 Enclosure Rating—Switches rated IP54 protect against dust and splashing water.
    NEMA 13 Enclosure Rating— NEMA 13 rated switches can be used in dirty, wet, and oily areas.
    Pressure Set
    Point, in. H₂O
    Approx. Difference Between Set
    Point and Reset Point, in. H₂O
    Max. Input
    Pressure
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use
    With
    Certification
    Enclosure
    Rating
    Each
    Screw-Terminal Wire Connection
     
    1/4" Barbed Male Tube Connection
    0.08 to 1.20.0540 in. H₂O±1%1.5 amp @ 120V AC
    400 mA @ 250V AC
    0 to 185Nylon
    AirC-ETL Listed, ETL Listed
    IP54, NEMA 13
    3964N11000000
    0.12 to 1.60.0840 in. H₂O±1%1.5 amp @ 120V AC
    400 mA @ 250V AC
    0 to 185Nylon
    AirC-ETL Listed, ETL Listed
    IP54, NEMA 13
    3964N1200000
    0.2 to 20.0940 in. H₂O±1%1.5 amp @ 120V AC
    400 mA @ 250V AC
    0 to 185Nylon
    AirC-ETL Listed, ETL Listed
    IP54, NEMA 13
    3964N1300000
    0.8 to 40.4540 in. H₂O±1%1.5 amp @ 120V AC
    400 mA @ 250V AC
    0 to 185Nylon
    AirC-ETL Listed, ETL Listed
    IP54, NEMA 13
    3964N1400000
    2 to 100.740 in. H₂O±1%1.5 amp @ 120V AC
    400 mA @ 250V AC
    0 to 185Nylon
    AirC-ETL Listed, ETL Listed
    IP54, NEMA 13
    3964N1500000
    4 to 201.240 in. H₂O±1%1.5 amp @ 120V AC
    400 mA @ 250V AC
    0 to 185Nylon
    AirC-ETL Listed, ETL Listed
    IP54, NEMA 13
    3964N1600000
     
    1/8 NPT Female Pipe Connection
    0.07 to 0.150.0445 in. H₂O±3%15 amp @ 120V AC
    15 amp @ 240V AC
    15 amp @ 480V AC
    -30 to 180Aluminum
    AirCE Marked, FM Approved, UL Recognized Component
    40915K5400000
    0.15 to 0.550.145 in. H₂O±3%15 amp @ 120V AC
    15 amp @ 240V AC
    15 amp @ 480V AC
    -30 to 180Aluminum
    AirCE Marked, FM Approved, UL Recognized Component
    40915K5600000
    0.4 to 1.60.1645 in. H₂O±3%15 amp @ 120V AC
    15 amp @ 240V AC
    15 amp @ 480V AC
    -30 to 180Aluminum
    AirCE Marked, FM Approved, UL Recognized Component
    40915K6100000
    1.4 to 5.50.345 in. H₂O±3%15 amp @ 120V AC
    15 amp @ 240V AC
    15 amp @ 480V AC
    -30 to 180Aluminum
    AirCE Marked, FM Approved, UL Recognized Component
    40915K6200000
    3 to 11.750.445 in. H₂O±3%15 amp @ 120V AC
    15 amp @ 240V AC
    15 amp @ 480V AC
    -30 to 180Aluminum
    AirCE Marked, FM Approved, UL Recognized Component
    40915K6300000
    4 to 200.545 in. H₂O±3%15 amp @ 120V AC
    15 amp @ 240V AC
    15 amp @ 480V AC
    -30 to 180Aluminum
    AirCE Marked, FM Approved, UL Recognized Component
    40915K6500000
    5 to 440.8310 psi±2%15 amp @ 120V AC
    15 amp @ 240V AC
    15 amp @ 480V AC
    -20 to 180SteelAirCE Marked, CSA Certified, FM Approved, UL Recognized Component
    40915K71000000
    9 to 852.1510 psi±2%15 amp @ 120V AC
    15 amp @ 240V AC
    15 amp @ 480V AC
    -20 to 180SteelAirCE Marked, CSA Certified, FM Approved, UL Recognized Component
    40915K72000000
     

    Differential Pressure Switches with Dial Indicator for Air

    Image of Product. Front orientation. Differential Pressure Switches. Differential Pressure Switches with Dial Indicator for Air.
    Troubleshoot and monitor the difference in air pressure between two points—these switches have a dial indicator to show differential pressure in real time. The dial indicator operates independently, so you can read it even if the power is off. These switches are often used with ovens, dryers, and HVAC systems to indicate a filter is clogged or help you maintain a certain pressure. They activate at two set pressures, so you can trigger different processes, such as turning on a fan when pressure is too low or opening an exhaust vent if it’s too high. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on or from on to off. All are CE marked, so they meet European safety standards.
    When measuring pressure in ductwork, pair them with a static pressure probe.
    Pressure Set
    Point, in. H₂O
    Approx. Difference Between Set
    Point and Reset Point, in. H₂O
    Max. Input
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use
    With
    Certification
    Each
    Wire Lead Connection
     
    1/8 NPT Female Pipe Connection
    0 to 0.50.0125±3%500 mA @ 125V AC
    1 amp @ 30V DC
    300 mA @ 110V DC
    20 to 120Aluminum
    AirCE Marked
    4570N110000000
    0 to 10.0225±2%500 mA @ 125V AC
    1 amp @ 30V DC
    300 mA @ 110V DC
    20 to 120Aluminum
    AirCE Marked
    4570N12000000
    0 to 20.0525±2%500 mA @ 125V AC
    1 amp @ 30V DC
    300 mA @ 110V DC
    20 to 120Aluminum
    AirCE Marked
    4570N13000000
    0 to 50.125±2%500 mA @ 125V AC
    1 amp @ 30V DC
    300 mA @ 110V DC
    20 to 120Aluminum
    AirCE Marked
    4570N14000000
    0 to 100.225±2%500 mA @ 125V AC
    1 amp @ 30V DC
    300 mA @ 110V DC
    20 to 120Aluminum
    AirCE Marked
    4570N15000000
    0 to 150.525±2%500 mA @ 125V AC
    1 amp @ 30V DC
    300 mA @ 110V DC
    20 to 120Aluminum
    AirCE Marked
    4570N16000000
     

    Differential Pressure Switches with Dial Indicator for Liquids

    Image of Product. Front orientation. Differential Pressure Switches. Differential Pressure Switches with Dial Indicator for Liquids.
    To check the difference in pressure between two points, these switches have a dial indicator that shows differential pressure in real time. The dial indicator operates independently of the switch. You’ll sometimes see these switches used to indicate a filter is clogged in a pump or cooling system. When the differential pressure reaches your setpoint, they turn equipment on and off, activate automated controls, or signal alarms. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on or from on to off.
    Rated NEMA 4X, these switches protect against dirt, washdown, and corrosion. They are also rated IP65 for protection from dust and rinsing. All are CSA certified, so they meet Canadian safety standards.
    Pressure Set Point
    Approx. Difference Between Set
    Point and Reset Point
    Max. Input
    Pressure, psi
    Accuracy
    Max. Switching Current
    @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Certification
    Enclosure
    Rating
    Hazardous Location Rating
    Each
    Screw-Terminal Wire Connection
     
    1/4 NPT Female Pipe Connection
    0 in. H₂O to 25 in. H₂O5 in. H₂O1,500±2%250 mA @ 120V AC-20 to 175BrassCleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Oil, WaterCSA Certified
    IP65, NEMA 4X
    NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G
    4587N110000000
    0 psi to 1 psi0.2 psi1,500±2%250 mA @ 120V AC-20 to 175BrassCleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Oil, WaterCSA Certified
    IP65, NEMA 4X
    NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G
    4587N12000000
    0 psi to 5 psi1 psi1,500±2%250 mA @ 120V AC-20 to 175BrassCleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Oil, WaterCSA Certified
    IP65, NEMA 4X
    NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G
    4587N13000000
    3 psi to 15 psi3 psi5,000±2%250 mA @ 120V AC-40 to 175BrassCleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Oil, WaterCSA Certified
    IP65, NEMA 4X
    NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G
    40945K81000000
    6 psi to 30 psi6 psi5,000±2%250 mA @ 120V AC-40 to 175BrassCleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Oil, WaterCSA Certified
    IP65, NEMA 4X
    NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G
    40945K82000000
    10 psi to 50 psi10 psi5,000±2%250 mA @ 120V AC-40 to 175BrassCleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Oil, WaterCSA Certified
    IP65, NEMA 4X
    NEC Class I Division 2 Groups A, B, C, D; NEC Class II Division 2 Groups F, G
    40945K83000000
     

    Differential Pressure Transmitters with Electronic Switch Outputs

    Image of Product. Front orientation. Differential Pressure Transmitters. Differential Pressure Transmitters with Electronic Switch Outputs.
    Get the flexibility of a differential pressure transmitter and a switch in one. These transmitters can work as a traditional transmitter using an analog output but also have electronic switch outputs and IO Link compatibility, making them great for advanced automation applications. Also known as transducers, they measure the difference in pressure between two inputs and convert it to electrical signal. Connect them to your programmable logic controller or receiving device to monitor differential pressure remotely, activate automated controls, or trigger alarms when they reach the set pressure. A digital display lets you monitor the differential pressure and troubleshoot issues at the source. It rotates for readability.
    You’ll often see these transmitters used to indicate a clogged filter or help maintain a certain pressure in HVAC systems, pumps, and cooling systems. NEMA and IP rated, they protect against dirt, dust, corrosion, weather, washdowns, and temporary submersion.
    For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
    Configurable Analog
    Transmitter Output
    Configurable
    Digital Switch Output
    Mounting
    Holes
    Connection
    Pressure Differential,
    psi
    Max. Input
    Pressure, psi
    Input Voltage,
    V DC
    Pipe
    Size
    Ht.
    Wd.
    No.
    of
    Signal
    No.
    of
    Signal
    Type
    Mounting Hardware
    Included
    Dia.
    No.
    of
    Enclosure Rating
    For Use With
    Accuracy
    Pipe
    Material
    Temp. Range,
    ° F
    Each
    5 Poles M12 Plug In
     
    Glass-Filled Polyester Plastic Housing
    0 to 152,50015 to 321/4
    4 13/16"3"10 to 10V DC, 4 to 20 mA2PNP, NPNNo3/16"2IP65, IP67, NEMA 4X, NEMA 6
    Air, Hydraulic Fluid, Water±0.5%NPT Female316L Stainless Steel
    14 to 1584682N11000000000
    0 to 1002,50015 to 321/4
    4 13/16"3"10 to 10V DC, 4 to 20 mA2PNP, NPNNo3/16"2IP65, IP67, NEMA 4X, NEMA 6
    Air, Hydraulic Fluid, Water±0.5%NPT Female316L Stainless Steel
    14 to 1584682N1200000000
    0 to 5002,50015 to 321/4
    4 13/16"3"10 to 10V DC, 4 to 20 mA2PNP, NPNNo3/16"2IP65, IP67, NEMA 4X, NEMA 6
    Air, Hydraulic Fluid, Water±0.5%NPT Female316L Stainless Steel
    14 to 1584682N1300000000
     

    Hazardous Location Differential Pressure Switches for Air

    Image of Product. Front orientation. Differential Pressure Switches.
    With an explosion-proof enclosure that meets NEMA 7 and 9 standards for hazardous locations, these switches were tested and verified by UL for use where explosive gas or dust may be present. Often used with ovens, dryers, and HVAC systems, they can indicate a filter is clogged or help maintain a certain air pressure. These switches turn equipment on and off, activate automated controls, or signal alarms when the differential pressure reaches your setpoint. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on or from on to off.
    In addition to being UL listed, these switches are CE marked and FM approved, so they also meet European safety standards. They also are IP and NEMA rated for use outdoors and protect against dust and splashing water.
    When measuring pressure in ductwork, pair them with a static pressure probe.
    Pressure Set Point Range
    Approx. Difference Between Set
    Point and Reset Point
    Max. Input
    Pressure
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use
    With
    Enclosure Rating
    Hazardous Location Rating
    Each
    Screw-Terminal Wire Connection
     
    1/8 NPT Female Pipe Connection
    0.07 in. H₂O to 0.15 in. H₂O0.13 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N110000000
    0.15 in. H₂O to 0.5 in. H₂O0.05 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N12000000
    0.4 in. H₂O to 1.6 in. H₂O0.18 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N13000000
    1.4 in. H₂O to 5.5 in. H₂O0.35 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N14000000
    3 in. H₂O to 11 in. H₂O0.45 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N15000000
    4 in. H₂O to 20 in. H₂O0.5 in. H₂O45 in. H₂O±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N16000000
    0.5 psi to 2 psi0.3 psi35 psi±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    -40 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N17000000
    1.5 psi to 8 psi1 psi35 psi±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    0 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N18000000
    3 psi to 15 psi0.9 psi35 psi±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    0 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N19000000
    4 psi to 25 psi0.7 psi35 psi±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    0 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N21000000
    15 psi to 50 psi1.25 psi70 psi±2%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    0 to 140Aluminum
    AirIP54, NEMA 3, NEMA 7, NEMA 9
    NEC Class I Divisions 1, 2 Groups C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5114N22000000
     

    Hazardous Location Differential Pressure Switches for Liquids

    Image of Product. Front orientation. Differential Pressure Switches. Hazardous Location Differential Pressure Switches for Liquids.
    Tested and verified by UL and C-UL for use where explosive dust or gas are present, these switches have an explosion-proof enclosure that meets NEMA 7 and 9 standards for hazardous locations. They are often used to indicate a filter is clogged in a pump or cooling system. When the differential pressure reaches your setpoint, these switches can turn equipment on and off, activate automated controls, or signal alarms. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on or from on to off.
    In addition to being UL and C-UL listed, these switches are CE marked, so they also meet European safety standards. All switches are IP and NEMA rated for use outdoors and to protect against some corrosion, dust, and washdowns.
    Pressure Set
    Point Range
    Approx. Difference Between Set
    Point and Reset Point
    Max. Input
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure Rating
    Hazardous Location Rating
    Each
    Screw-Terminal Wire Connection
     
    1/4 NPT Female Pipe Connection
    5 in. H₂O to 80 in. H₂O2.5 in. H₂O225±0.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    2 amp @ 30V DC
    1 amp @ 48V DC
    500 mA @ 125V DC
    -10 to 200Aluminum
    Diesel Fuel, Gasoline, Petroleum-Based Hydraulic Oil, WaterNEMA 4X, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5214N110000000
    2 psi to 20 psi0.2 psi225±0.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    2 amp @ 30V DC
    1 amp @ 48V DC
    500 mA @ 125V DC
    -10 to 200Aluminum
    Diesel Fuel, Gasoline, Petroleum-Based Hydraulic Oil, WaterNEMA 4X, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5214N12000000
    3 psi to 30 psi0.25 psi225±0.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    2 amp @ 30V DC
    1 amp @ 48V DC
    500 mA @ 125V DC
    -10 to 200Aluminum
    Diesel Fuel, Gasoline, Petroleum-Based Hydraulic Oil, WaterNEMA 4X, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5214N13000000
    10 psi to 100 psi0.6 psi225±0.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    2 amp @ 30V DC
    1 amp @ 48V DC
    500 mA @ 125V DC
    -10 to 200Aluminum
    Diesel Fuel, Gasoline, Petroleum-Based Hydraulic Oil, WaterNEMA 4X, NEMA 7, NEMA 9, IP66
    NEC Class I Divisions 1, 2 Groups B, C, D; NEC Class II Divisions 1, 2 Groups E, F, G
    5214N14000000
     

    Air-Pressure-Actuated HVAC Switches

    Image of Product. Front orientation. HVAC Switches. Air-Pressure-Actuated HVAC Switches.
    Often used to detect clogged air filters and iced air conditioner coils, these switches sense small changes in pressure between two points in your duct.
    Pressure Set
    Point, in. H₂O
    Accuracy,
    in. H₂O
    Temp. Range,
    ° F
    Current @ Voltage
    Electrical
    Connection Type
    Switch
    Designation
    Max. Pressure,
    psi
    Low Pressure Side
    Connection
    High Pressure Side
    Inside Connection
    High Pressure Side
    Outside Connection
    For Use
    Outdoors
    Enclosure
    Rating
    Certification
    Each
    Diaphragm Sensors
    0.05 to 50.025-40 to 1652.9 amp @ 240V AC
    5.8 amp @ 120V AC
    HardwireSPDT
    11/8 NPT Female1/8 NPT Female1/2 NPSMNoNEMA 1
    CSA Certified, UL Listed
    1795K10000000
    0.05 to 50.04-40 to 1654.9 amp @ 240V AC
    9.8 amp @ 120V AC
    HardwireSPDT
    11/8 NPT Female1/8 NPT Female1/2 NPSMNoNEMA 1
    CSA Certified, UL Listed
    1795K6000000
     

    Airflow-Actuated HVAC Switches

    Image of Product. Front orientation. HVAC Switches. Airflow-Actuated HVAC Switches.
    Use this switch to sense changes in airflow velocity in duct. The paddle extends into the duct and actuates the switch when airflow reaches the setpoint. Switch is rated NEMA 3R for protection from dirt, falling liquids, and light splashing.
    Paddle
    Speed Set Point,
    fpm
    Temp. Range,
    ° F
    Current @ Voltage
    Electrical
    Connection
    Switch
    Designation
    For Conduit
    Trade Size
    Knockout
    Dia.
    Material
    Ht.
    Wd.
    For Use
    Outdoors
    Enclosure
    Rating
    Certification
    Each
    Paddle Sensors
    350 to 50032 to 10410 amp @ 240V AC
    16 amp @ 120V AC
    Screw TerminalSPDT
    1/2
    7/8"Stainless Steel
    6 7/8"3 1/8"YesIP43, NEMA 3R
    UL Listed, C-UL Listed, CE Marked
    1783K130000000
     
    back to top