McMaster-Carr logo
    Enter e-mail addresses in the fields below
    Message
    Cancel
    Comments
    E-mail address (if you would like a response)
    5 Products

    Pressure-Regulating Valves for Cryogenic Liquids

    Image of Product. Front orientation. Pressure-Regulating Valves. Pressure-Regulating Valves for Cryogenic Liquids.
    These valves can withstand the extreme cold of liquid argon, liquid carbon dioxide, liquid nitrogen, and liquid oxygen. All are cleaned and bagged for oxygen service and other high-purity applications. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range.
    Inlet
    Outlet
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Pipe
    Size
    Location
    Pressure Adjustment
    Method
    End-to-End
    Lg.
    For Use With
    Temp. Range,
    ° F
    Choose an Outlet Pressure, psi
    Each
    NPT Female
     
    Brass Body—Bronze Diaphragm and PTFE Seal
    1/4
    Side6001/4
    SideScrew1 3/4"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    15 to 65
    ,
    75 to 175
    ,
    100 to 250
    47435K310000000
    3/8
    Side6003/8
    SideScrew1 3/4"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    15 to 65
    ,
    75 to 175
    ,
    100 to 250
    47435K32000000
     

    Long-Life Pressure-Regulating Valves for Cryogenic Liquids

    Image of Product. Front orientation. Pressure-Regulating Valves. Long-Life Pressure-Regulating Valves for Cryogenic Liquids.
    For a longer service life than standard valves for cryogenic liquids, these have a durable bronze body. All are cleaned and bagged for oxygen service and other high-purity applications. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Valves are designed to withstand the extreme cold of liquid argon, liquid carbon dioxide, liquid nitrogen, and liquid oxygen. They have an internal strainer to trap debris.
    Inlet
    Outlet
    Pipe
    Size
    Location
    Max. Pressure,
    psi
    Pipe
    Size
    Location
    Pressure Adjustment
    Method
    End-to-End
    Lg.
    For Use With
    Temp. Range,
    ° F
    Choose an Outlet Pressure, psi
    Each
    NPT Female
     
    Bronze Body—Bronze Diaphragm and PTFE Seal with Internal Strainer
    1/4
    Side4001/4
    SideScrew3 1/16"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    10 to 30
    ,
    75 to 250
    49165K390000000
    1/2
    Side4001/2
    SideScrew4 1/2"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    10 to 30
    ,
    20 to 75
    ,
    20 to 100
    ,
    50 to 250
    49165K59000000
    1
    Side4001
    SideScrew5 7/8"Liquid Argon, Liquid Carbon Dioxide, Liquid Nitrogen, Liquid Oxygen-320 to 150
    10 to 35
    ,
    20 to 60
    ,
    20 to 100
    ,
    75 to 250
    49165K79000000
     
    back to top