The small dial on these gauges allows for installation in tight spaces. Use them with pumps, filters, regulators, and in process lines to measure and display pressure.
Gauges with brass case are more impact resistant than ABS plastic-case gauges.
- For Use With: Air, Water, Hydraulic Fluid, and Natural Gas
- Accuracy: ±5% Full Scale (Grade D)
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
0 to 500 | 20 | 100 |
Center Back Connection | ||||||
---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Mounting Orientation | Each | |
NPT Male | ||||||
1" | 1/8 | -50° to 160° | -50° to 160° | Any | 0000000 | 000000 |
Digital High-Accuracy Pressure Gauges

With Bottom
Connection

A four-digit LCD display allows for easy reading of measurements. The LCD shuts off automatically to extend battery life. Gauges are commonly used with pneumatic regulators, compressors, and in critical processes that require high accuracy, such as hydraulic and laboratory applications.
- For Use With: Air, Water, Hydraulic Fluid, Gasoline, Diesel Fuel, Natural Gas
- Accuracy: ±1% Full Scale (Not Graded)
Available Pressure Ranges | |||
---|---|---|---|
Pressure Range | |||
psi | bar | MPa | Resolution, psi |
0 to 500 | 0 to 34.4 | 0 to 3.4 | 0.1 |
Bottom Connection | ||||||||
---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Batteries Included | Mounting Orientation | Features | Each | |
NPT Male | ||||||||
2 1/2" | 1/4 | 0° to 185° | 15° to 140° | Yes | Any | 3-min. Automatic Shut-Off, Maximum Reading Recall | 00000000 | 0000000 |
NPT Male Calibration Certificate Traceable to NIST | ||||||||
2 1/2" | 1/4 | 0° to 185° | 15° to 140° | Yes | Any | 3-min. Automatic Shut-Off, Maximum Reading Recall | 00000000 | 000000 |
Extreme-Temperature Pressure Gauges




These gauges can withstand both extremely cold and extremely hot temperatures. Use them with pumps, filters, regulators, and in process lines to measure and display pressure. Mount them with the dial face upright.
- For Use With: Air, Water, Hydraulic Fluid, Gasoline, Diesel Fuel, and Natural Gas
- Accuracy: ±0.5% Mid Scale (Not Graded)
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
2 1/2" Dial Diameter | ||
0 to 500 | 5 | 50 |
3 1/2" Dial Diameter | ||
0 to 500 | 5 | 50 |
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Mounting Orientation | Each | |
NPT Male | ||||||
---|---|---|---|---|---|---|
2 1/2" | 1/4 | -65° to 400° | -65° to 600° | Upright | 0000000 | 0000000 |
Flange | Bolt | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Mounting Orientation | Location | OD | Mounting Fasteners Included | Circle Dia. | Hole Dia. | No. of Holes | Each | |
NPT Male | ||||||||||||
3 1/2" | 1/4 | -65° to 400° | -65° to 600° | Upright | Back | 4 3/4" | No | 4 1/4" | 7/32" | 3 | 0000000 | 0000000 |
- For Use With: Air, Water, Hydraulic Fluid, Gasoline, Diesel Fuel, and Natural Gas
- Accuracy: ±0.5% Mid Scale (Not Graded)
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
0 to 500 | 5 | 50 |
Bottom Connection (Flange Mount) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Mounting | ||||||||||
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | Mounting Orientation | Fasteners Included | Hole Dia. | No. of Holes | Each | |
NPT Male | ||||||||||
4 1/2" | 1/2 | -65° to 400° | -65° to 600° | Yellow | Upright | No | 7/32" | 3 | 0000000 | 0000000 |
Pressure Transmitters


M12 Plug
Connection



Plug
Connection

Deutsch-Style
Plug Connection
Remotely monitor pressure in general purpose applications such as pumping and compressing systems. These transmitters, also known as transducers, convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Transmitters with voltage output connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
Transmitters with calibration certificate traceable to NIST include documentation that states they've passed a test for accuracy.
Transmitters are rated NEMA 4X and IP65 or IP67 and are good for washdown and corrosive environments.
Transmitters with a micro M12 plug connection are compatible with micro M12 connectors.
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy:
0-15 psi Pressure Range: ±1.5%
All Other Pressure Ranges: ±1% - Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material:
0-15 psi Pressure Range: 316L Stainless Steel
All Other Pressure Ranges: 304 Stainless Steel - Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 500 | 1,000 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 0000000 |
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy:
0-15 psi Pressure Range: ±1.5%
All Other Pressure Ranges: ±1% - Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material:
0-15 psi Pressure Range: 316L Stainless Steel
All Other Pressure Ranges: 304 Stainless Steel - Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 500 | 1,000 | 9-36V DC | 1/4 | 1 11/16" | 15/16" | IP67, NEMA 4X | 00000000 | 0000000 |
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±1%
- Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material: 304 Stainless Steel
- Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Electrical Connection Thread Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 500 | 1,000 | 9-36V DC | 1/4 | PG-9 | 3 7/16" | 1 5/16" | IP65, NEMA 4X | 00000000 | 0000000 |
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy:
0-15 psi Pressure Range: ±1.5%
All Other Pressure Ranges: ±1% - Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material:
0-15 psi Pressure Range: 316L Stainless Steel
All Other Pressure Ranges: 304 Stainless Steel - Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Electrical Connection Thread Size | Ht. | Wd. | Environmental Rating | Each | |
Transmitters | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
0-500 | 500 | 1,000 | 9-36V DC | 1/8 | PG-7 | 2 5/8" | 1 3/8" | IP65, NEMA 4X | 00000000 | 0000000 |
0-500 | 500 | 1,000 | 9-36V DC | 1/4 | PG-7 | 2 5/8" | 1 3/8" | IP65, NEMA 4X | 0000000 | 000000 |
Transmitters with Calibration Certificate Traceable to NIST | ||||||||||
0-500 | 500 | 1,000 | 9-36V DC | 1/4 | PG-7 | 2 5/8" | 1 3/8" | IP65, NEMA 4X | 0000000 | 000000 |
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±1.0%
- Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material: 304 Stainless Steel
- Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 500 | 1,000 | 9-36V DC | 1/4 | 2 1/16" | 1 1/16" | IP67, NEMA 4X | 00000000 | 0000000 |
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±1.0%
- Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material: 304 Stainless Steel
- Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 500 | 1,000 | 9-36V DC | 1/4 | 2 1/16" | 1 1/16" | IP67, NEMA 4X | 00000000 | 0000000 |
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy:
0-15 psi Pressure Range: ±1.5%
All Other Pressure Ranges: ±1% - Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material:
0-15 psi Pressure Range: 316L Stainless Steel
All Other Pressure Ranges: 304 Stainless Steel - Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 500 | 1,000 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 0000000 |
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy:
0-15 psi Pressure Range: ±1.5%
All Other Pressure Ranges: ±1% - Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material:
0-15 psi Pressure Range: 316L Stainless Steel
All Other Pressure Ranges: 304 Stainless Steel - Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 500 | 1,000 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 0000000 |
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy:
0-15 psi Pressure Range: ±1.5%
All Other Pressure Ranges: ±1% - Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material:
0-15 psi Pressure Range: 316L Stainless Steel
All Other Pressure Ranges: 304 Stainless Steel - Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 500 | 1,000 | 9-36V DC | 1/4 | 1 11/16" | 7/8" | IP67, NEMA 4X | 00000000 | 0000000 |
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±1%
- Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material: 304 Stainless Steel
- Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Electrical Connection Thread Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 500 | 1,000 | 9-36V DC | 1/4 | PG-9 | 3 7/16" | 1 5/16" | IP65, NEMA 4X | 00000000 | 0000000 |
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy:
0-15 psi Pressure Range: ±1.5%
All Other Pressure Ranges: ±1% - Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material:
0-15 psi Pressure Range: 316L Stainless Steel
All Other Pressure Ranges: 304 Stainless Steel - Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Electrical Connection Thread Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 500 | 1,000 | 9-36V DC | 1/4 | PG-7 | 2 5/8" | 1 3/8" | IP65, NEMA 4X | 00000000 | 0000000 |
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy:
0-15 psi Pressure Range: ±1.5%
All Other Pressure Ranges: ±1% - Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material:
0-15 psi Pressure Range: 316L Stainless Steel
All Other Pressure Ranges: 304 Stainless Steel - Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 500 | 1,000 | 14-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 0000000 |
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy:
0-15 psi Pressure Range: ±1.5%
All Other Pressure Ranges: ±1% - Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material:
0-15 psi Pressure Range: 316L Stainless Steel
All Other Pressure Ranges: 304 Stainless Steel - Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 500 | 1,000 | 14-36V DC | 1/4 | 1 11/16" | 15/16" | IP67, NEMA 4X | 00000000 | 0000000 |
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±1%
- Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material: 304 Stainless Steel
- Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Electrical Connection Thread Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 500 | 1,000 | 14-36V DC | 1/4 | PG-9 | 3 7/16" | 1 5/16" | IP65, NEMA 4X | 00000000 | 0000000 |
- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy:
0-15 psi Pressure Range: ±1.5%
All Other Pressure Ranges: ±1% - Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material:
0-15 psi Pressure Range: 316L Stainless Steel
All Other Pressure Ranges: 304 Stainless Steel - Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Electrical Connection Thread Size | Ht. | Wd. | Environmental Rating | Each | |
Transmitters | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
0-500 | 500 | 1,000 | 14-36V DC | 1/4 | PG-7 | 2 5/8" | 1 3/8" | IP65, NEMA 4X | 00000000 | 0000000 |
Transmitters with Calibration Certificate Traceable to NIST | ||||||||||
0-500 | 500 | 1,000 | 14-36V DC | 1/4 | PG-7 | 2 5/8" | 1 3/8" | IP65, NEMA 4X | 0000000 | 000000 |
High-Accuracy Pressure Transmitters

- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy: See table
- Pipe Connection: NPT Male
- Housing Material: 304 Stainless Steel
- Connection Material: 17-4 PH Stainless Steel
- Temperature Range: See table
At least four times as accurate as standard pressure transmitters, these transmitters are ideal for use in laboratories and analytical testing applications. All come with a calibration certificate traceable to NIST that states they’ve passed a test for accuracy. Also known as transducers, pressure transmitters convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. As pressure increases, the output signal from the transmitter will increase. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. Transmitters will only provide accurate readings within the rated pressure range.
These transmitters connect using two wires to send a 4-20mA current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
All transmitters are CE marked, meaning they meet European safety standards. NEMA 4X rated transmitters are for use in washdown and corrosive environments. IP67 rated transmitters are protected from temporary submersion during washdowns.
Transmitters with Calibration Certificate Traceable to NIST | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Temperature Range, °F | Environmental Rating | Each | |
4-20mA Current Output—Wire Leads | ||||||||||
±0.25% Accuracy | ||||||||||
0-250 | 250 | 500 | 9-30V DC | 1/4 | 2 1/8" | 1" | -40° to 255° | IP67, NEMA 4X | 0000000 | 0000000 |
0-500 | 500 | 1,000 | 9-30V DC | 1/4 | 2 1/8" | 1" | -40° to 255° | IP67, NEMA 4X | 0000000 | 000000 |
Economy Pressure Transmitters

- For Use With: Air, Argon, Diesel Fuel, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±1.5%
- Pipe Connection: NPT Male
- Housing Material: 304 Stainless Steel
- Connection Material: 304 Stainless Steel
- Temperature Range: -20° to 220° F
Choose these transmitters when you need reliable pressure monitoring but not high accuracy. Also known as transducers, they convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
Rated IP65, all seal out dust and water from light rinses. They’re CE marked, so they meet European safety standards.
These transmitters connect using two wires to send a 4-20mA current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
4-20mA Current Output—Wire Leads | |||||||||
---|---|---|---|---|---|---|---|---|---|
0-500 | 500 | 750 | 12-36V DC | 1/4 | 1 13/16" | 15/16" | IP65 | 0000000 | 0000000 |
Absolute Pressure Transmitters
Monitor and control pressure in portable HVAC systems, hydraulics, and oil and gas equipment. Unlike other pressure transmitters that measure the difference between your system and the atmosphere, these transmitters give measurements relative to zero pressure—regardless of altitude or temperature. Also known as transducers, they convert pressure into an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers (PLCs), and motor speed controls. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. Transmitters will only provide accurate readings within the rated pressure range.
All transmitters are rated IP67 for protection from dust and temporary submersion during washdowns. Those that are rated NEMA 4X also protect against weather and corrosion.
Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.

- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±1.5%
- Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material: 316L Stainless Steel
- Temperature Range: -40° to 255° F
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 1,000 | 1,000 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 0000000 | 0000000 |
Hazardous Location Pressure Transmitters

- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±0.25%
- Pipe Connection: NPT Male
- Housing Material: 316 Stainless Steel
- Connection Material: 316 Stainless Steel
- Temperature Range: -40° to 130° F
FM approved and CSA certified for use in hazardous locations, these transmitters monitor pressure where combustible fumes may be present. Also known as transducers, they convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. You will need to calibrate your receiving device for the transmitter's pressure range and output signal for the receiving device to interpret the signal. The output signal from the transmitter increases as the pressure increases. Transmitters will only provide accurate readings within the rated pressure range.
These transmitters are rated IP67 for protection from dust and temporary submersion. They are CE marked, so they meet European safety standards.
With a current output, they connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
4-20mA Current Output—Wire Leads | |||||||||
---|---|---|---|---|---|---|---|---|---|
0-500 | 500 | 875 | 10-30V DC | 1/4 | 3 5/16" | 1 1/16" | IP67; NEC Class I Division 1 Groups A, B, C, D | 0000000 | 0000000 |
Pressure Transmitters for Oxygen

- For Use With: Oxygen
- Accuracy: ±1.0%
- Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material: 304 Stainless Steel
- Temperature Range: -40° to 255° F
Adhere to safety standards and monitor pressure when working with high concentrations of oxygen. These transmitters are cleaned following ASME B40.100 IV guidelines and are sealed in an airtight bag to prevent contamination before use. Also known as transducers, they convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
These transmitters are rated NEMA 4X and IP65 for protection from dust, weather, washdown, and corrosion. UL and C-UL recognized components and CE marked, they also meet American, Canadian, and European safety standards.
With a current output, they connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
4-20mA Current Output—Wire Leads | |||||||||
---|---|---|---|---|---|---|---|---|---|
0-500 | 1,000 | 1,000 | 9-36V DC | 1/4 | 2 3/8" | 1 5/16" | IP65, NEMA 4X | 0000000 | 0000000 |
Sanitary Pressure Transmitters

- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy: ±0.5%
- Housing Material: 304 Stainless Steel
- Connection Material: 316 Stainless Steel
- Temperature Range: 30° to 300° F
For use in sanitary applications such as food processing, these transmitters are 3-A certified. They are rated IP66, IP69K, and NEMA 4X to resist washdowns and corrosion. Also known as transducers, they convert pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. As pressure increases, the output signal from the transmitter will increase. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure range and output signal. Transmitters are accurate only within the pressure range.
These transmitters connect using two wires to send a 4-20mA current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices. Transmitters are compatible with micro M12 sockets.
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Ht. | Wd. | Environmental Rating | Specifications Met | Each | |
For 1 1/2" Flange OD | |||||||||
---|---|---|---|---|---|---|---|---|---|
4-20mA Current Output—5-Pole Micro M12 Plug Connection | |||||||||
0-500 | 500 | 1,000 | 10-40V DC | 2 5/16" | 2 7/16" | IP66, IP69K, NEMA 4X | 3-A Certified 74-06, CE Marked | 00000000 | 0000000 |
For 2" Flange OD | |||||||||
4-20mA Current Output—5-Pole Micro M12 Plug Connection | |||||||||
0-500 | 500 | 1,000 | 10-40V DC | 2 5/16" | 2 7/16" | IP66, IP69K, NEMA 4X | 3-A Certified 74-06, CE Marked | 00000000 | 000000 |
Adjustable-Range Pressure Transmitters

- For Use With: Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Water
- Accuracy: See table
- Pipe Connection: NPT Male
- Housing Material: 304 Stainless Steel
- Connection Material: 304 Stainless Steel
- Temperature Range: -20° to 180° F
Fine-tune the pressure range on these transmitters to account for changes in pressure readings over time. With an adjustable range, also known as adjustable zero and adjustable span, the top and bottom of the pressure range can be changed by up to 5%. This saves you from having to make corrections on receiving devices, such as programmable logic controllers (PLCs), remote displays, and motor speed controls. These transmitters, often called transducers, convert pressure to an electrical signal that is interpreted by receiving devices to monitor pressure or control equipment. As pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
Rated NEMA 4X, these transmitters stand up to washdowns and corrosion.
Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Transmitters with voltage output connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
Pressure Range, psi | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
±1% Accuracy | |||||||||
---|---|---|---|---|---|---|---|---|---|
4-20mA Current Output—Wire Leads | |||||||||
0-500 | 500 | 1,000 | 10-36V DC | 1/4 | 3" | 7/8" | NEMA 4X | 000000000 | 0000000 |
1-5V DC Voltage Output—Wire Leads | |||||||||
0-500 | 500 | 1,000 | 10-36V DC | 1/4 | 3" | 7/8" | NEMA 4X | 000000000 | 000000 |
±0.5% Accuracy | |||||||||
4-20mA Current Output—Wire Leads | |||||||||
0-500 | 500 | 1,000 | 10-36V DC | 1/4 | 3" | 7/8" | NEMA 4X | 000000000 | 000000 |
1-5V DC Voltage Output—Wire Leads | |||||||||
0-500 | 500 | 1,000 | 10-36V DC | 1/4 | 3" | 7/8" | NEMA 4X | 000000000 | 000000 |
Pressure and Vacuum Transmitters



- For Use With: Air, Argon, Diesel Fuel, Gasoline, Hydraulic Fluid, Nitrogen, Water
- Accuracy:
0-15 psi Pressure Range: ±1.5%
All Other Pressure Ranges: ±1% - Pipe Connection: NPT Male
- Housing Material: Glass-Reinforced Nylon
- Connection Material:
0-15 psi Pressure Range: 316L Stainless Steel
All Other Pressure Ranges: 304 Stainless Steel - Temperature Range: -40° to 255° F
Monitor and control vacuum pumps, air compressors, and hydraulics. These transmitters convert both pressure and vacuum into an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. As pressure increases, the output signal from the transmitter will increase. For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's pressure or vacuum range and output signal. Transmitters will only provide accurate readings within the rated pressure or vacuum range.
Transmitters with current output connect using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Transmitters with voltage output connect using three wires—two wires into the power supply and a separate wire that sends a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
All transmitters are rated NEMA 4X for use in washdown and corrosive environments. IP67 rated transmitters are protected from temporary submersion during washdowns. IP65 rated transmitters are protected from dust and low-pressure jets of water.
Transmitters with a micro M12 plug are compatible with micro M12 connectors.
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 30-0 | 1,000 | 1,000 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 0000000 |
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 30-0 | 1,000 | 1,000 | 9-36V DC | 1/4 | 1 11/16" | 7/8" | IP67, NEMA 4X | 00000000 | 0000000 |
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Electrical Connection Thread Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 30-0 | 1,000 | 1,000 | 9-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 00000000 | 0000000 |
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 30-0 | 1,000 | 1,000 | 9-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 0000000 |
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 30-0 | 1,000 | 1,000 | 14-36V DC | 1/4 | 1 15/16" | 15/16" | IP67, NEMA 4X | 00000000 | 0000000 |
Pressure Range, psi | Vacuum Range, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Input Voltage | Pipe Size | Electrical Connection Thread Size | Ht. | Wd. | Environmental Rating | Each | |
0-500 | 30-0 | 1,000 | 1,000 | 14-36V DC | 1/4 | PG-7 | 2 1/2" | 15/16" | IP65, NEMA 4X | 0000000 | 0000000 |
Differential Pressure Transmitters for Liquids
Used with pumps, cooling systems, and other liquid applications, these transmitters remotely measure the difference in pressure between two inputs. They are also known as transducers. These transmitters convert differential pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. You’ll often see them used to indicate a filter is clogged.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
IP66 rated transmitters are dust tight and protect against washdowns. NEMA 4X rated transmitters protect against weather, washdowns, and corrosion.

- For Use With: Diesel Fuel, Gasoline, Hydraulic Fluid, Water
- Accuracy: ±0.5%
- Pipe Connection: NPT Female
- Connection Material: 316 Stainless Steel
- Temperature Range: 0° to 200° F
Mounting Holes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range , psi | Max. Input Pressure, psi | Input Voltage | Pipe Size | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Environmental Rating | Each | |
4-20 mA Output Signal—Screw Terminals | |||||||||||
0-100 | 500 | 10-35V DC | 1/4 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 0000000 |
Differential Pressure Transmitters with Electronic Switch Outputs

- For Use With: Air, Hydraulic Fluid, Water
- Accuracy: ±0.5%
- Pipe Connection: NPT Female
- Housing Material: Glass-Reinforced Polyester
- Connection Material: 316L Stainless Steel
- Temperature Range: 14° to 158° F
Get the flexibility of a differential pressure transmitter and a switch in one. These transmitters can work as a traditional transmitter using an analog output but also have electronic switch outputs and IO Link compatibility, making them great for advanced automation applications. Also known as transducers, they measure the difference in pressure between two inputs and convert it to electrical signal. Connect them to your programmable logic controller or receiving device to monitor differential pressure remotely, activate automated controls, or trigger alarms when they reach the set pressure. A digital display lets you monitor the differential pressure and troubleshoot issues at the source. It rotates for readability.
You’ll often see these transmitters used to indicate a clogged filter or help maintain a certain pressure in HVAC systems, pumps, and cooling systems. NEMA and IP rated, they protect against dirt, dust, corrosion, weather, washdowns, and temporary submersion.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
Configurable Analog Transmitter Output | Configurable Digital Switch Output | Mounting Holes | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range, psi | Max. Input Pressure, psi | Input Voltage | Pipe Size | Ht. | Wd. | No. of | Signal | No. of | Signal Type | Mounting Hardware Included | Dia. | No. of | Environmental Rating | Each | |
5-Pole Micro M12 Plug Connection | |||||||||||||||
0-500 | 2,500 | 15-32V DC | 1/4 | 4 13/16" | 3" | 1 | 0-10V DC, 4-20 mA | 2 | PNP, NPN | No | 3/16" | 2 | IP65, IP67, NEMA 4X, NEMA 6 | 0000000 | 000000000 |
High-Accuracy Digital Test Gauges for Pressure



Not only do these gauges have an accuracy of ±0.25%, they also have a four-digit LCD display that allows for easy reading of measurements. Use them for testing, calibrating, laboratory applications, and other critical applications that require precision.
Gauges with 4-20mA current output convert pressure to an electrical signal for remote monitoring.
- For Use With: See Table
- Accuracy: ±0.25% Full Scale (Not Graded)
Available Pressure Ranges | |||
---|---|---|---|
Pressure Range | |||
psi | bar | MPa | Resolution, psi |
0 to 500 | 0 to 35 | 0 to 3.5 | 1 |
Dial | Bottom Connection | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Pipe Size | Environment Temperature Range, °F | Process Temperature Range, °F | Environment | For Use With | Features | Digit Ht. | Batteries Included | Each | |
NPT Male | |||||||||||
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | __ | Air, Hydraulic Fluid, Water | 5-min. Automatic Shut-Off | 1/2" | Yes | 0000000 | 0000000 |
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | Hazardous Location | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water | 5-min. Automatic Shut-Off | 1/2" | Yes | 0000000 | 000000 |
NPT Male—Calibration Certificate Traceable to NIST | |||||||||||
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | __ | Air, Hydraulic Fluid, Water | 5-min. Automatic Shut-Off | 1/2" | Yes | 0000000 | 000000 |
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | Hazardous Location | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water | 5-min. Automatic Shut-Off | 1/2" | Yes | 0000000 | 000000 |
- For Use With: See Table
- Accuracy: ±0.25% Full Scale (Not Graded)
Available Pressure Ranges | |||
---|---|---|---|
Pressure Range | |||
psi | bar | MPa | Resolution, psi |
0 to 500 | 0 to 35 | 0 to 3.5 | 1 |
Dial | Bottom Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Pipe Size | Environment Temperature Range, °F | Process Temperature Range, °F | For Use With | Digit Ht. | Wire Connection Type | Input Voltage | Each | |
NPT Male | ||||||||||
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | Air, Hydraulic Fluid, Water | 1/2" | Wire Leads | 8-24V AC, 9-32V DC | 0000000 | 0000000 |
NPT Male—Calibration Certificate Traceable to NIST | ||||||||||
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | Air, Hydraulic Fluid, Water | 1/2" | Wire Leads | 8-24V AC, 9-32V DC | 0000000 | 000000 |
- For Use With: See Table
- Accuracy: ±0.25% Full Scale (Not Graded)
- Environmental Rating: 0 to 1,000 psi: NEMA 2, All other psi ranges: NEMA 4X
Available Pressure Ranges | |
---|---|
Pressure Range, psi | Resolution, psi |
0 to 500 | 1 |
Dial | Bottom Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Pipe Size | Environment Temperature Range, °F | Process Temperature Range, °F | For Use With | Digit Ht. | Wire Connection Type | Input Voltage | Each | |
NPT Male | ||||||||||
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | Air, Hydraulic Fluid, Water | 1/2" | Wire Leads | 8-32V DC | 0000000 | 0000000 |
NPT Male—Calibration Certificate Traceable to NIST | ||||||||||
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | Air, Hydraulic Fluid, Water | 1/2" | Wire Leads | 8-32V DC | 0000000 | 000000 |
Corrosion-Resistant Test Gauges for Pressure


All-stainless steel construction makes these gauges suitable for testing and calibrating in corrosive environments.
- For Use With:
3" Dial Dia.: Air, Hydraulic Fluid, Water
4 1/2" Dial Dia.: Air, Hydraulic Fluid, Natural Gas, Water - Accuracy: ±0.5% Full Scale (Grade 2A)
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
4 1/2" Dial Dia. | ||
0 to 500 | 5 | 50 |
Bottom Connection | |||||
---|---|---|---|---|---|
Dial Dia. | Pipe Size | Environment Temperature Range, °F | Process Temperature Range, °F | Each | |
NPT Male—Calibration Certificate Traceable to NIST | |||||
4 1/2" | 1/2 | -40° to 150° | -40° to 225° | 0000000 | 0000000 |
Cleaned and Bagged Pressure-Regulating Valves for Air and Inert Gas

- For Use With: Nitrogen, Oxygen, Argon, Helium, Neon
- Temperature Range: -40° to 165° F
Often used for oxygen service and other high-purity applications, these valves are cleaned and bagged to meet CGA G-4.1 standards to prevent contamination. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Valves have two gauge ports. They are no-bleed style, so they keep process gases contained in the valve.
Inlet | Outlet | Gauge Port | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | Pipe Size | Location | End-to-End Lg. | Choose an Outlet Pressure Range, psi | Each | |
NPT Female | ||||||||||
Brass Body—Buna-N Diaphragm and Fluoroelastomer Seal | ||||||||||
1/2 | Side | 500 | 1/2 | Side | 1/4 | Side | 2 13/16" | 00000000 | 0000000 | |
3/4 | Side | 500 | 3/4 | Side | 1/4 | Side | 3 5/16" | 00000000 | 000000 | |
1 | Side | 500 | 1 | Side | 1/4 | Side | 3 5/16" | 00000000 | 000000 |
Panel-Mount Ultra-High-Pressure-Regulating Valves for Air and Inert Gas

- For Use With: Air, Nitrogen, Argon, Helium
- Temperature Range: -40° to 165° F
These valves are rated for inlet pressures up to 6,000 psi. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Threads below the adjustment knob and an included mounting bracket let you install these valves in instrument panels. They have two gauge ports. An internal strainer traps debris.
Inlet | Outlet | Gauge Port | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | Pipe Size | Location | End-to-End Lg. | Panel Cutout Dia. | Specifications Met | Outlet Pressure Range, psi | Each | |
NPT Female | ||||||||||||
Brass Body—Polyimide Seal | ||||||||||||
1/4 | Side | 6,000 | 1/4 | Side | 1/4 | Side | 2 1/8" | 2 1/4" | ASME B31.3 | 0 to 500 | 0000000 | 000000000 |
Panel-Mount High-Pressure-Regulating Valves for Air and Inert Gas

- For Use With: Air, Nitrogen, Argon, Helium
- Temperature Range: -40° to 165° F
Withstand inlet pressures up to 3,500 psi. These valves automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Valves have threads below the adjustment knob and come with a panel-mount nut. All have two gauge ports. An internal strainer traps debris.
Inlet | Outlet | Gauge Port | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | Pipe Size | Location | End-to-End Lg. | Panel Cutout Dia. | Specifications Met | Outlet Pressure Range, psi | Each | |
NPT Female | ||||||||||||
Brass Body—316 Stainless Steel Diaphragm and PTFE Seal | ||||||||||||
1/4 | Side | 3,500 | 1/4 | Side | 1/4 | Side | 2" | 1 3/8" | ASME B31.3 | 0 to 500 | 0000000 | 0000000 |
Cleaned and Bagged Panel-Mount
Pressure-Regulating Valves for Air and Inert Gas

- For Use With: Air, Nitrogen, Argon, Helium
- Temperature Range: -40° to 165° F
Commonly used for oxygen service and other high-purity applications, these valves come cleaned and bagged to prevent contamination. All automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Valves have threads below the adjustment knob and come with a panel-mount nut. They can also be surface mounted. All have two gauge ports. Body is 316 stainless steel for exceptional corrosion resistance. Valves are no-bleed style, so they keep process gases contained in the valve.
Inlet | Outlet | Gauge Port | |||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | Pressure Range, psi | Pipe Size | Connection | End-to-End Lg. | Panel Cutout Dia. | Each | |
NPT Female | |||||||||||
316 Stainless Steel Body—316 Stainless Steel Diaphragm and PTFE Seal | |||||||||||
1/4 | Side | 3,500 | 1/4 | Side | 0 to 500 | 1/4 | NPT Female | 5 3/8" | 1.37" | 0000000 | 0000000 |
1/2 | Side | 500 | 1/2 | Side | 0 to 25 | 1/4 | NPT Female | 5 1/2" | 1.37" | 0000000 | 00000000 |
1/2 | Side | 500 | 1/2 | Side | 0 to 100 | 1/4 | NPT Female | 5 1/2" | 1.37" | 0000000 | 00000000 |
1/2 | Side | 500 | 1/2 | Side | 0 to 150 | 1/4 | NPT Female | 5 1/2" | 1.37" | 0000000 | 00000000 |
Tank-Mount Pressure-Regulating Valves for Moisture Removal

- For Use With: Nitrogen
- Temperature Range: 32° to 120° F
Designed for nitrogen gas purging in air conditioning, refrigeration, and plumbing systems, these valves automatically reduce a high inlet pressure to a lower, stable outlet pressure. They have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Valves have 45° flared tube outlet fittings for a tight seal on metal tubing. They come with a gauge to monitor inlet pressure from the tank. They are single stage and reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank.
Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
Inlet | Outlet | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
CGA Number | Location | Thread Direction | Pressure Gauge Range, psi | Stage | For Tube OD | Location | Thread Direction | Purging Flow Range, cfh | Brazing Flow Range, cfh | Testing Pressure Range, psi | Each | |
NGO Male Inlet × 45° Flared UN/UNF (SAE 45°) Male Outlet with 7/16"-20 End | ||||||||||||
Brass Body—PTFE Seal | ||||||||||||
CGA 580 | Side | Right Hand | 0 to 3,000 | Single | 1/4" | Side | Right Hand | 25 to 35 | 3 to 6 | 0 to 500 | 00000000 | 0000000 |
Tank-Mount Pressure-Regulating Valves for Air and Inert Gas
- For Use With: See Table
- Temperature Range: -20° to 120° F
These valves automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. All have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Valves have a gauge to monitor outlet pressure and a gauge to monitor inlet pressure from the tank.
Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
Single-stage valves reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank. They’re best for applications where a constant outlet pressure isn’t critical.
Valves with a brass body have a longer service life than valves with a brass and steel body.
Valves with flared tube outlet fittings form a tight seal on metal tubing.

Inlet | Outlet | Material | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
CGA Number | Location | Thread Direction | Pressure Gauge Range, psi | Location | Thread Direction | Pressure Range, psi | Pressure Adjustment Method | Body | Seal | Diaphragm | Each | |
For Use With Argon, Helium, and Nitrogen | ||||||||||||
45° Flared UN/UNF (SAE 45°) Male Outlet × NGO Male Inlet | ||||||||||||
CGA 580 | Side | Right Hand | 0 to 4,000 | Side | Right Hand | 0 to 500 | T-Handle | Brass | PTFE | Neoprene | 00000000 | 0000000 |
High-Purity Tank-Mount Pressure-Regulating Valves for Inert Gas
- For Use With: See Table
- Temperature Range: -20° to 120° F
Reduce contaminants in research sample systems, emission monitoring systems, chromatography, and other high-purity applications that use argon, helium, nitrogen, or carbon dioxide. These valves have a 316 stainless steel and brass body with a smooth finish to reduce dust collection and internal components designed to protect the seal and diaphragm from contamination. They automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. All have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Outlet fittings are Swagelok® for a leak-free seal around hard metal tubing in high-pressure lines. Also known as instrumentation fittings, Swagelok® fittings are compatible with Parker A-Lok, Gyrolok, Bilok, and Tylok fittings. Valves have a gauge to monitor outlet pressure and a gauge to monitor inlet pressure from the tank.
Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
Single-stage valves reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank. They’re best for applications where a constant outlet pressure isn’t critical.

Inlet | Outlet | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
CGA Number | Location | Thread Direction | Pressure Gauge Range, psi | Stage | For Tube OD | Location | Pressure Range, psi | Pressure Adjustment Method | Each | |
Swagelok® Female Outlet × NGO Male Inlet | ||||||||||
Brass Body—316 Stainless Steel Diaphragm and PTFE Seal | ||||||||||
CGA 580 | Side | Right Hand | 0 to 4,000 | Single | 1/4" | Side | 0 to 500 | Knob | 0000000 | 0000000 |
Pressure-Regulating Valves for Fuel Gases

- For Use With: See table
- Temperature Range: See table
Install these valves directly in gas distribution pipelines for acetylene, hydrogen, or propane. They automatically reduce a high inlet pressure to a lower, stable outlet pressure. Valves have two outlets to fit various pipe configurations and come with a plug to close the unused outlet. The gauge monitors outlet pressure. All valves are single stage and reduce pressure in one step, which causes the outlet pressure to fluctuate.
Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
Inlet | Outlet | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
For Use With | Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | Pressure Adjustment Method | Pressure Gauge Range, psi | Temperature Range, °F | End-to-End Lg. | Port-to-Port Lg. | Each | |
NPT Female | ||||||||||||
Brass Body—Stainless Steel Diaphragm and Neoprene Seal | ||||||||||||
Hydrogen, Propane | 1/4 | Side | 500 | 1/4 | Bottom, Side | T-Handle | 0 to 60 | 0° to 120° | 2.40" | 1.01" | 0000000 | 0000000 |
Hydrogen, Propane | 1/4 | Side | 500 | 1/4 | Bottom, Side | T-Handle | 0 to 200 | 0° to 120° | 2.40" | 1.01" | 0000000 | 000000 |
Tank-Mount Pressure-Regulating Valves for Fuel Gases
- For Use With: See Table
- Temperature Range: -20° to 120° F
Attach these valves to acetylene, hydrogen, methane, propane, or propylene tanks to reduce a high inlet pressure to a lower, stable outlet pressure. They have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Valves come with a gauge to monitor outlet pressure and a gauge to monitor inlet pressure from the tank.
Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
Single-stage valves reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank. They’re best for applications where a constant outlet pressure isn’t critical.
Two-stage valves progressively reduce pressure over two steps for more consistent outlet pressure at all times. They’re often used in applications that require a constant outlet pressure regardless of the tank level.
Valves with a brass body have a longer service life than valves with a brass and steel body.
Valves with a stainless steel diaphragm can withstand harsh environments.




Inlet | Outlet | Material | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CGA Number | Location | Thread Direction | Pressure Gauge Range, psi | Thread Size | Location | Thread Direction | Pressure Range, psi | Pressure Adjustment Method | Body | Seal | Diaphragm | Each | |
For Use With Acetylene | |||||||||||||
UNF Male Outlet × NGO Female Inlet | |||||||||||||
CGA 300 | Side | Right Hand | 0 to 400 | 9/16"-18 | Side | Left Hand | 0 to 15 | Knob | Brass/Steel | PTFE | Rubber | 0000000 | 0000000 |
CGA 300 | Side | Right Hand | 0 to 400 | 9/16"-18 | Side | Left Hand | 0 to 15 | T-Handle | Brass | PTFE | Rubber | 000000 | 000000 |
UNF Male Outlet × NGO Male Inlet | |||||||||||||
CGA 510 | Side | Left Hand | 0 to 400 | 9/16"-18 | Side | Left Hand | 0 to 15 | Knob | Brass/Steel | PTFE | Rubber | 0000000 | 000000 |
CGA 510 | Side | Left Hand | 0 to 400 | 9/16"-18 | Side | Left Hand | 0 to 15 | T-Handle | Brass | PTFE | Rubber | 000000 | 000000 |
CGA 510 | Side | Left Hand | 0 to 400 | 9/16"-18 | Side | Left Hand | 0 to 15 | T-Handle | Brass | PTFE | Stainless Steel | 0000000 | 000000 |
For Use With Propane and Propylene | |||||||||||||
UNF Male Outlet × NGO Male Inlet | |||||||||||||
CGA 510 | Side | Left Hand | 0 to 400 | 9/16"-18 | Side | Left Hand | 5 to 50 | Knob | Brass/Steel | PTFE | Rubber | 0000000 | 000000 |


Inlet | Outlet | Material | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
CGA Number | Location | Thread Direction | Pressure Gauge Range, psi | Thread Size | Location | Thread Direction | Pressure Range, psi | Pressure Adjustment Method | Body | Seal | Diaphragm | Each | |
For Use With Acetylene | |||||||||||||
UNF Male Outlet × NGO Female Inlet | |||||||||||||
CGA 300 | Side | Right Hand | 0 to 400 | 9/16"-18 | Side | Left Hand | 0 to 15 | T-Handle | Brass/Steel | PTFE | Rubber | 000000 | 0000000 |
UNF Male Outlet × NGO Male Inlet | |||||||||||||
CGA 510 | Side | Left Hand | 0 to 400 | 9/16"-18 | Side | Left Hand | 0 to 15 | T-Handle | Brass | PTFE | Stainless Steel | 0000000 | 000000 |
CGA 510 | Side | Left Hand | 0 to 400 | 9/16"-18 | Side | Left Hand | 0 to 15 | T-Handle | Brass/Steel | PTFE | Rubber | 0000000 | 000000 |
For Use With Propane and Propylene | |||||||||||||
UNF Male Outlet × NGO Male Inlet | |||||||||||||
CGA 510 | Side | Left Hand | 0 to 400 | 9/16"-18 | Side | Left Hand | 0 to 50 | T-Handle | Brass/Steel | PTFE | Rubber | 0000000 | 000000 |
High-Purity Tank-Mount Pressure-Regulating Valves for Fuel Gases

- For Use With: Hydrogen, Methane
- Temperature Range: -20° to 120° F
Designed to reduce contaminants in high-purity applications using hydrogen and methane gas, these valves have a stainless steel and brass body with a smooth finish to reduce dust collection and internal components designed to protect the seal and diaphragm from contamination. They’re often used in research sample systems, emission monitoring systems, and chromatography. Valves automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. All have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Outlet fittings are Swagelok® for a leak-free seal around hard metal tubing in high-pressure lines. Also known as instrumentation fittings, Swagelok® fittings are compatible with Parker A-Lok, Gyrolok, Bilok, and Tylok fittings. Valves come with a gauge to monitor outlet pressure and a gauge to monitor inlet pressure from the tank.
Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
Two-stage valves progressively reduce pressure over two steps for more consistent outlet pressure at all times. They’re often used in applications that require a constant outlet pressure regardless of the tank level.
Inlet | Outlet | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
CGA Number | Location | Thread Direction | Pressure Gauge Range, psi | Stage | For Tube OD | Location | Pressure Range, psi | Pressure Adjustment Method | Each | |
Swagelok® Female Outlet × NGO Female Inlet | ||||||||||
Brass/Stainless Steel Body—316 Stainless Steel Diaphragm and PTFE Seal with Relief Valve | ||||||||||
CGA 350 | Side | Left Hand | 0 to 4,000 | Two | 1/4" | Side | 0 to 500 | Knob | 0000000 | 0000000 |
Tank-Mount Pressure-Regulating Valves for Cryogenic Cylinders

- For Use With: See Table
- Temperature Range: -20° to 120° F
Automatically reduce a high inlet pressure from compressed gas tanks to a lower, stable outlet pressure. These valves can remove gases from liquid cryogenic cylinders. They have Compressed Gas Association (CGA) numbered inlet fittings for secure connections to compressed gas tanks. Choose a valve with the same CGA number as your tank and other system components. Valves come with a gauge to monitor outlet pressure. They are single stage and reduce pressure in one step, which causes the outlet pressure to fluctuate slightly as you empty the tank.
Choose a valve with a maximum outlet pressure that’s approximately twice your application’s normal operating pressure. Your operating pressure should never exceed 75% of the valve’s maximum outlet pressure.
Inlet | Outlet | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
For Use With | CGA Number | Location | Thread Direction | Stage | Thread Size | Location | Thread Direction | Pressure Range, psi | Pressure Adjustment Method | Each | |
UNF Male Outlet × NGO Female Inlet | |||||||||||
Brass Body—Stainless Steel Diaphragm and PTFE Seal | |||||||||||
Carbon Dioxide | CGA 320 | Side | Right Hand | Single | 9/16"-18 | Bottom | Right Hand | 0 to 350 | T-Handle | 0000000 | 0000000 |
UNF Male Outlet × NGO Male Inlet | |||||||||||
Brass Body—Stainless Steel Diaphragm and PTFE Seal | |||||||||||
Argon, Nitrogen | CGA 580 | Side | Right Hand | Single | 9/16"-18 | Bottom | Right Hand | 0 to 350 | T-Handle | 0000000 | 000000 |
Versa-Mount Precision Compressed Air Regulators

Mount these regulators to a 35 mm DIN rail or a wall with one of the two included brackets. With an accuracy of ±0.2%, use these regulators to adjust and maintain air pressure in sensitive applications where constant, consistent pressure is important. All are relieving regulators, so they exhaust when the downstream pressure exceeds the set pressure. Install in your air line after filters.
Pipe Size | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Gauge Included | No. of Gauge Ports | For DIN Rail Ht., mm | Wd. | Ht. | Max. Temp., °F | Includes | Regulating Accuracy | Choose a Pressure Regulating Range, psi | Each | |
Aluminum Housing | ||||||||||||||
NPT Female Inlet and Outlet | ||||||||||||||
1/4 | 1/4 | 60 scfm @ 100 psi | 500 | No | 1 | 35 | 3" | 7" | 200° | DIN-Rail Mounting Bracket, Wall Mounting Bracket | ±0.2% | 000000 | 0000000 | |
3/8 | 3/8 | 60 scfm @ 100 psi | 500 | No | 1 | 35 | 3" | 7" | 200° | DIN-Rail Mounting Bracket, Wall Mounting Bracket | ±0.2% | 000000 | 000000 | |