About Pipe Size
More
About Pressure Gauges
More
About Pressure Transmitters
More
About Air Preparation
More
High-Accuracy Low-Pressure Gauges






Measure small pressure changes in ventilation systems, hydraulic applications, and other critical processes with these high-accuracy gauges. Mount them with the dial face upright.
Gauges with 304 stainless steel case or polyester plastic case have better corrosion resistance than gauges with steel case.
Gauges with safety case blow out in the back under excess pressure, protecting the operator in front.
- For Use With: Air, Water, Hydraulic Fluid, Carbon Dioxide, and Natural Gas
- Accuracy: ±1.5% Full Scale (Not Graded)
Available Pressure Gauges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
0 to 10 | 0.2 | 2 |
Bottom Connection | Center Back Connection | ||||||||
---|---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | Mounting Orientation | Each | Each | ||
NPT Male | |||||||||
2 1/2" | 1/4 | 0° to 140° | 0° to 140° | Black | Upright | 0000000 | 000000 | 0000000 | 000000 |
NPT Male with Calibration Certificate Traceable to NIST | |||||||||
2 1/2" | 1/4 | 0° to 140° | 0° to 140° | Black | Upright | 0000000 | 000000 | 0000000 | 000000 |
- For Use With: Air, Water, Hydraulic Fluid, Carbon Dioxide, and Natural Gas
- Accuracy: ±1% Full Scale (Grade 1A)
Available Pressure Gauges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
0 to 10 | 0.2 | 2 |
Bottom Connection | ||||||
---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Mounting Orientation | Each | |
NPT Male | ||||||
4" | 1/4 | 0° to 140° | 0° to 140° | Upright | 000000 | 0000000 |
- For Use With: Air, Argon, Nitrogen, and Natural Gas
- Accuracy: ±1% Mid Scale (Grade A)
Available Pressure Ranges | |||||
---|---|---|---|---|---|
Pressure Range | Graduation Marks | Numeric Increments | |||
psi | in. of Hg | psi | in. of Hg | psi | in. of Hg |
0 to 10 | 0 to 20 | 0.1 | 0.2 | 1 | 2 |
Mounting | Bottom Connection (Flange Mount) | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | Orientation | Fasteners Included | Hole Dia. | No. of Holes | Features | Each | |
NPT Male | |||||||||||
4 1/2" | 1/4 | 0° to 140° | -40° to 210° | Black | Upright | No | 1/4" | 3 | Safety Case | 000000 | 0000000 |
Low-Pressure Differential Gauges with Digital Display

Measure small changes in air pressure with these hand-held gauges. They have a four-digit LCD display for easy reading of measurements. Gauges are commonly used to indicate clogged filters and to monitor fans and blowers.
- For Use With: Air, Natural Gas
- Accuracy: ±0.5% Full Scale (Not Graded)
Pressure Range | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
kPa | in. of H₂O | Resolution, in. of H₂O | Max. Pressure, psi | For Tube ID | Environment Temp. Range, °F | Process Temp. Range, °F | Digit Ht. | Ht. | Wd. | Batteries Included | Environmental Rating | Each | |
Barbed Tube Connection | |||||||||||||
0-4.982 | 0-20 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 0000000 |
Barbed Tube Connection with Calibration Certificate Traceable to NIST | |||||||||||||
0-4.982 | 0-20 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | 6 1/2" | 2 13/16" | Yes | NEC Class I Division 2 Groups A, B, C, D | 0000000 | 000000 |
Optional Nylon Carrying Case | 0000000 | Each | 000000 |
Low-Pressure Differential Gauges with Inclined Scale
Easier to read than U-tube gauges, these use an inclined scale to measure pressure or velocity in air applications. Gauges are also known as manometers.

- For Use With: Air
- Accuracy: ±3% Full Scale (Not Graded)
Indicating Liquid | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pressure Range, in. of H₂O | Max. Pressure, psi | Max. Process Temp. Range, °F | Ht. | Color | Specific Gravity | Mount Type | Mounting Fasteners Included | Includes | Each | |
With Barbed Tube Connection for 3/16" Tube ID | ||||||||||
0-3 | 10 | 140° | 6" | Red | 0.826 | Screw On | Yes | 8-ft. Lg. Tubing; Indicating Liquid | 000000 | 000000 |
0-7 | 10 | 140° | 6" | Blue | 1.91 | Screw On | Yes | 8-ft. Lg. Tubing; Indicating Liquid | 000000 | 000000 |
High-Pressure Differential Gauges

These gauges are able to withstand line pressures up to 3,000 psi. They are commonly used to measure pressure differences in pumps and filters.
Gauges with 316 stainless steel case are more corrosion resistant than gauges with an aluminum case.
- For Use With: Water, Hydraulic Fluid, and Gasoline
- Accuracy: ±2% Full Scale (Not Graded)
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
2 1/2" Dial Diameter | ||
0 to 10 | 0.5 | 2 |
4 1/2" Dial Diameter | ||
0 to 10 | 0.5 | 2 |
- For Use With: Water, Hydraulic Fluid, and Gasoline
- Accuracy: ±2% Full Scale (Not Graded)
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
2 1/2" Dial Diameter | ||
0 to 10 | 0.5 | 2 |
4 1/2" Dial Diameter | ||
0 to 10 | 0.5 | 2 |
Medium-Pressure Differential Gauges

Popular for use with natural gas, these gauges measure pressure differences in pipelines and filters with a maximum pressure of 1,500 psi.
Gauges with 316 stainless steel case are more corrosion resistant than gauges with an aluminum case.
- For Use With: Water, Hydraulic Fluid, Gasoline, and Natural Gas
- Accuracy: ±2% Full Scale (Not Graded)
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
0 to 10 | 0.5 | 2 |
- For Use With: Water, Hydraulic Fluid, Gasoline, and Natural Gas
- Accuracy: ±2% Full Scale (Not Graded)
Available Pressure Ranges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
0 to 10 | 0.5 | 2 |
Differential Pressure and Vacuum Gauges with Digital Display
Gauges have a four-digit LCD display for easy reading of measurements. Commonly used to indicate clogged filters, these gauges display the difference between two pressure or vacuum measurements. They are also known as compound gauges.

- For Use With: Air
- Accuracy: ±0.5% Full Scale (Not Graded)
Pressure Range | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
psi | kPa | in. of H₂O | mbar | Vacuum Range, in. of Hg | Resolution, in. of H₂O | Max. Pressure, psi | For Tube ID | Environment Temp. Range, °F | Process Temp. Range, °F | Digit Ht. | Batteries Included | Features | Each | |
Barbed Tube Connection | ||||||||||||||
0-0.723 | 0-4.982 | 0-20" | 0-49.82 | 1.471"-0 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 0000000 |
Barbed Tube Connection with Calibration Certificate Traceable to NIST | ||||||||||||||
0-0.723 | 0-4.982 | 0-20" | 0-49.82 | 1.471"-0 | 0.01 | 10 | 1/8"-3/16" | 35° to 100° | 0° to 140° | 3/8" | Yes | 40-Reading Memory, Overpressure Alarm | 0000000 | 000000 |
Differential Pressure Transmitters with Digital Display for Air
With a digital display and selectable differential pressure ranges, these transmitters are a versatile alternative to transmitters with dial indicators. Unlike a standard transmitter that has one wider differential pressure range, these transmitters have multiple ranges to choose from. The selectable pressure range means they are more accurate than standard transmitters since their accuracy applies to each small range rather than a single wide range. They can also be configured to output either current or voltage, while standard transmitters typically output one signal type. The digital display allows you to troubleshoot and monitor differential pressure at the source. Also known as transducers, they measure the difference in pressure between two inputs and convert it to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. They are often used to indicate a filter is clogged or help you maintain a certain air pressure in ovens, dryers, and HVAC systems. All are rated UL 94 V-0, so they meet flammability standards. CE marked, they also meet European safety standards.
When measuring pressure in ductwork, pair them with a static pressure probe. Transmitters with an 8" pressure probe cable include a static pressure probe.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
Connect them using two wires when using the current output. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices. For voltage output, connect them using three wires—two wires into the power supply and a separate wire to send a signal to the receiver. The receiver and the transmitter share a common ground wire back to the power supply.
DIN-rail/surface mount transmitters give you mounting flexibility. They include the bracket you'll need for mounting it to DIN rail.
Transmitters with a calibration certificate traceable to NIST have passed tests for accuracy.
Transmitters that meet IP67 protect against dust and submersion.

- For Use With: Air
- Accuracy: ±1%
- Tube Connection Type: Barbed
- Connection Material: Brass
- Temperature Range: 32° to 122° F
Mounting Holes | Transmitters with Calibration Certificate Traceable to NIST | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range, in. of H2O | Max. Input Pressure, psi | Input Voltage | For Tube ID | For DIN Rail Ht., mm | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Pressure Probe Cable Length | Environmental Rating | Each | |
4-20 mA, 0-5V DC, 0-10V DC Output Signal—Screw Terminals | |||||||||||||
Surface Mount | |||||||||||||
-5 to 5 -2.5 to 2.5 -1 to 1 -0.5 to 0.5 0 to 0.5 0 to 1 0 to 2.5 0 to 5 | 10 | 13-30V DC | 3/16" | __ | No | 3/16" | 2 | 5 7/16" | 3 3/16" | __ | IP67 | 0000000 | 0000000 |
DIN-Rail/Surface Mount | |||||||||||||
-5 to 5 -2.5 to 2.5 -1 to 1 -0.5 to 0.5 0 to 0.5 0 to 1 0 to 2.5 0 to 5 | 10 | 13-30V DC | 3/16" | 35 | No | 3/16" | 2 | 5 7/16" | 3 3/16" | 8" | IP67 | 0000000 | 000000 |
Differential Pressure Transmitters with Dial Indicator for Air

- For Use With: Air
- Accuracy: ±2%
- Pipe Connection: NPT Female
- Housing Material: Aluminum
- Connection Material: Aluminum
- Temperature Range: 20° to 120° F
Check the difference in air pressure between two inputs at the source using the dial indicator or remotely using a receiver. The dial indicator on these transmitters operates independently and shows differential pressure in real time for troubleshooting. Also known as transducers, these transmitters convert pressure to an electrical signal that is interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls. They are often used to indicate a filter is clogged or help you maintain a certain air pressure in ovens, dryers, and HVAC systems. All are CE marked, so they meet European safety standards.
When measuring pressure in ductwork, pair them with a static pressure probe.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Mounting Holes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range , in. of H2O | Max. Input Pressure, psi | Input Voltage | Pipe Size | For No. of Wires | Mounting Hardware Included | Thread Size | No. of | Dia. | Specifications Met | Each | |
4-20 mA Output Signal—Screw Terminals | |||||||||||
0-0.5 | 10 | 10-35V DC | 1/8 | 2 | No | 6-32 | 3 | 5 1/2" | CE Marked | 000000000 | 0000000 |
0-1 | 10 | 10-35V DC | 1/8 | 2 | No | 6-32 | 3 | 5 1/2" | CE Marked | 000000000 | 000000 |
0-6 | 10 | 10-35V DC | 1/8 | 2 | No | 6-32 | 3 | 5 1/2" | CE Marked | 000000000 | 000000 |
Differential Pressure Transmitters for Liquids
Used with pumps, cooling systems, and other liquid applications, these transmitters remotely measure the difference in pressure between two inputs. They are also known as transducers. These transmitters convert differential pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. You’ll often see them used to indicate a filter is clogged.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
IP66 rated transmitters are dust tight and protect against washdowns. NEMA 4X rated transmitters protect against weather, washdowns, and corrosion.

- For Use With: Diesel Fuel, Gasoline, Hydraulic Fluid, Water
- Accuracy: ±0.5%
- Pipe Connection: NPT Female
- Connection Material: 316 Stainless Steel
- Temperature Range: 0° to 200° F
Mounting Holes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range , psi | Max. Input Pressure, psi | Input Voltage | Pipe Size | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Environmental Rating | Each | |
4-20 mA Output Signal—Screw Terminals | |||||||||||
0-10 | 50 | 10-35V DC | 1/4 | No | 1/4" | 2 | 2" | 1 7/16" | IP66, NEMA 4X | 0000000 | 0000000 |
High-Accuracy Differential Pressure Transmitters

- For Use With: Air, Water
- Accuracy: ±0.25%
- Pipe Connection: NPT Female
- Housing Material: Aluminum
- Connection Material: 17-4 PH Stainless Steel
- Temperature Range: 0° to 175° F
At least twice as accurate as standard transmitters, these transmitters sense differential pressure at an accuracy of ±0.25%. Use them in laboratories or testing applications where the difference in pressure between two points needs to be measured with high accuracy. These transmitters are often used to indicate a filter is clogged or help you maintain a certain pressure in pumps, HVAC, cooling, and other air and liquid systems. They convert differential pressure to an electrical signal that can be interpreted by receiving devices, such as remote displays, programmable logic controllers, and motor speed controls to monitor pressure or control equipment. All transmitters are rated NEMA 4 for protection in washdown environments.
For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the pressure range and output signal of the transmitter. As the differential increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range. Connect them using two wires. The same wire is used to send a signal to the receiver and to power the transmitter. Current doesn’t lose signal over long distances and isn’t affected by electrical interference from other devices.
Mounting Holes | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Differential Pressure Range, psi | Max. Input Pressure, psi | Input Voltage | Pipe Size | Mounting Hardware Included | Dia. | No. of | Ht. | Wd. | Environmental Rating | Each | |
4-20 mA Output Signal—Screw Terminals | |||||||||||
0-10 | 350 | 9-30V DC | 1/4 | Yes | 5/32" | 4 | 3 1/8" | 2 7/16" | NEMA 4 | 0000000 | 000000000 |
Ultra-High-Accuracy Digital Test Gauges for Pressure


With an accuracy of ±0.05%, these have the highest accuracy of all our test gauges. Use them for testing, calibrating, laboratory applications, and other critical processes that require precision. They have a five-digit LCD display that allows for easy reading of measurements.
- For Use With: Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water
- Accuracy: ±0.05% Full Scale (Grade 5A)
Available Pressure Ranges | ||||||
---|---|---|---|---|---|---|
Pressure Range | ||||||
psi | kPa | bar | kg/cm2 | MPa | in. of H2O | Resolution, psi |
0 to 10 | 0 to 65 | 0 to 0.6 | 0 to 0.7 | 0 to 0.06 | 0 to 270 | 0.001 |
Bottom Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|
Dial Dia. | Pipe Size | Environment Temperature Range, °F | Process Temperature Range, °F | Environmental Rating | Features | Digit Ht. | Batteries Included | Each | |
NPT Male—Calibration Certificate Traceable to NIST | |||||||||
3" | 1/4 | -40° to 180° | 0° to 150° | NEC Class I Divisions 1, 2 Groups A, B, C, D NEC Class II Divisions 1, 2 Groups E, F, G NEC Class III Divisions 1, 2 IP65 | Configurable Automatic Shut-Off (2 min., 5 min., 15 min., 30 min., or Never) | 1 1/8" | Yes | 0000000 | 000000000 |
Vibration-Damping Pressure-Regulating
Valves for Water, Oil, Air, and Inert Gas

- For Use With: Water, Oil, Air, Inert Gas
- Temperature Range: See Table
A cast iron body absorbs vibration from pressure changes to reduce wear and noise in your pipeline. These valves automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range.
Inlet | Outlet | ||||||||
---|---|---|---|---|---|---|---|---|---|
Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | Temperature Range | End-to-End Lg. | Outlet Pressure Range, psi | Each | |
NPT Female | |||||||||
Cast Iron Body—Fluoroelastomer Diaphragm and 420 Stainless Steel Seal | |||||||||
3/8 | Side | 250 | 3/8 | Side | 32° to 300° F | 4 1/4" | 0 to 10 | 0000000 | 0000000 |
1/2 | Side | 250 | 1/2 | Side | 32° to 300° F | 3 5/8" | 0 to 10 | 0000000 | 000000 |
3/4 | Side | 250 | 3/4 | Side | 32° to 300° F | 3 5/8" | 0 to 10 | 0000000 | 000000 |
1 | Side | 250 | 1 | Side | 32° to 300° F | 4 1/2" | 0 to 10 | 0000000 | 000000 |
2 | Side | 250 | 2 | Side | 32° to 300° F | 6 1/2" | 0 to 10 | 0000000 | 000000 |
Plastic Panel-Mount Pressure-Regulating Valves for Water

- For Use With: Water
- Temperature Range: 40° to 150° F
For easy panel mounting in your water system, these valves have threads below the adjustment knob and come with a panel-mount nut. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Body is polysulfone, which is lightweight and corrosion resistant.
Inlet | Outlet | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Size | Location | Max. Pressure, psi | Pipe Size | Thread Size | Location | End-to-End Lg. | Panel Cutout Dia. | Outlet Pressure Range, psi | Each | |
NPT Female | |||||||||||
Polysulfone Body—Buna-N/EPDM Diaphragm and Polyurethane Seal | |||||||||||
1/8 | __ | Side | 150 | 1/8 | __ | Side | 1 9/16" | 9/16" | 0.5 to 10 | 00000000 | 000000 |
UNF Female | |||||||||||
Polysulfone Body—Buna-N/EPDM Diaphragm and Polyurethane Seal | |||||||||||
__ | 10-32 | Side | 150 | __ | 10-32 | Side | 1 1/8" | 9/16" | 0.5 to 10 | 00000000 | 00000 |
Plastic Panel-Mount Pressure-Regulating Valves for Air

- For Use With: Air
- Temperature Range: 40° to 150° F
Regulate pressure in air and inert gas systems from your instrument panel—these valves have threads below the adjustment knob and come with a panel-mount nut. All automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Body is polysulfone, which is lightweight and corrosion resistant.
Inlet | Outlet | ||||||||
---|---|---|---|---|---|---|---|---|---|
Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | End-to-End Lg. | Panel Cutout Dia. | Outlet Pressure Range, psi | Each | |
NPT Female | |||||||||
Polysulfone Body—Buna-N/EPDM Diaphragm and Polyurethane Seal | |||||||||
1/8 | Side | 150 | 1/8 | Side | 1 9/16" | 9/16" | 0.5 to 10 | 00000000 | 000000 |
Pressure-Regulating Valves with Compression Fittings for Food and Beverage

- For Use With: Food and Beverage
- Temperature Range: 35° to 125° F
Compression fittings bite down on hard metal and plastic tubing for a tighter seal than push-to-connect fittings. These valves automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. The Buna-N/stainless steel diaphragm and EPDM seal are FDA compliant 21 CFR 177.2600.
Inlet | Outlet | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
For Tube OD | Location | Max. Pressure, psi | For Tube OD | Location | Pressure Adjustment Method | End-to-End Lg. | Specifications Met | Outlet Pressure Range, psi | Each | |
Compression Female | ||||||||||
Acetal Body—Buna-N/Stainless Steel Diaphragm and EPDM Seal | ||||||||||
1/4" | Side | 250 | 1/4" | Side | Knob | 2" | FDA Compliant 21 CFR 177.2600 | 1 to 10 | 0000000 | 0000000 |
Pressure-Regulating Valves for Steam

- For Use With: Steam
- Temperature Range: -20° to 400° F
Automatically reduce a high, variable inlet pressure in your steam system to a lower, stable outlet pressure. Adjust the outlet pressure within the range. These valves have a cast iron body that absorbs vibration from pressure changes to reduce wear and noise in your pipeline.
Valves | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Inlet | Outlet | Repair Kits | ||||||||
Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | End-to-End Lg. | Outlet Pressure Range, psi | Each | Each | ||
NPT Female | ||||||||||
Cast Iron Body—Bronze Diaphragm and 420 Stainless Steel Seal | ||||||||||
1/2 | Side | 250 | 1/2 | Side | 3 5/8" | 0 to 10 | 0000000 | 0000000 | 0000000 | 000000 |
3/4 | Side | 250 | 3/4 | Side | 3 5/8" | 0 to 10 | 0000000 | 000000 | 0000000 | 00000 |
1 | Side | 250 | 1 | Side | 4 1/2" | 0 to 10 | 0000000 | 000000 | 0000000 | 000000 |
1 1/4 | Side | 250 | 1 1/4 | Side | 4 1/2" | 0 to 10 | 0000000 | 000000 | 0000000 | 000000 |
1 1/2 | Side | 250 | 1 1/2 | Side | 6 1/2" | 0 to 10 | 0000000 | 000000 | 0000000 | 000000 |
2 | Side | 250 | 2 | Side | 6 1/2" | 0 to 10 | 0000000 | 000000 | 0000000 | 000000 |
Back-Pressure-Regulating Valves for Air and Inert Gas

- For Use With: Air, Inert Gas
- Temperature Range: 0° to 150° F
Often used to protect equipment running on air compressors, these valves obstruct flow to maintain sufficient operating pressure in your system. If the system pressure exceeds the set pressure, they exhaust through the unthreaded relief port. Adjust the set pressure within the range. Valves have two gauge ports.
Inlet | Outlet | Gauge Port | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | Pipe Size | Location | End-to-End Lg. | Outlet Pressure Range, psi | Each | |
NPT Female | ||||||||||
Aluminum Body—Buna-N Diaphragm and Seal | ||||||||||
1/4 | Side | 250 | 1/4 | Side | 1/4 | Side | 3" | 0 to 10 | 0000000 | 0000000 |
3/8 | Side | 250 | 3/8 | Side | 1/4 | Side | 3" | 0 to 10 | 0000000 | 000000 |
1/2 | Side | 250 | 1/2 | Side | 1/4 | Side | 3" | 0 to 10 | 0000000 | 000000 |
Panel-Mount Back-Pressure-Regulating Valves for Air and Inert Gas

- For Use With: Air, Inert Gas
- Temperature Range: 40° to 150° F
Threads below the adjustment knob and an included panel-mount nut allow you to add these valves to your instrument panel. Often used in systems running on air compressors, they're installed after pressure-sensitive equipment to obstruct flow and maintain a consistent operating pressure. If the system pressure exceeds the set pressure, they exhaust through the outlet. Adjust the set pressure within the range.
Inlet | Outlet | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Thread Size | Location | Max. Pressure, psi | Pipe Size | Thread Size | Location | End-to-End Lg. | Panel Cutout Dia. | Outlet Pressure Range, psi | Each | |
NPT Female | |||||||||||
Polysulfone Body—Buna-N Diaphragm and Silicone Seal | |||||||||||
1/8 | __ | Side | 100 | 1/8 | __ | Side | 1 1/8" | 9/16" | 0.5 to 10 | 00000000 | 000000 |
UNF Female | |||||||||||
Polysulfone Body—Buna-N Diaphragm and Silicone Seal | |||||||||||
__ | 10-32 | Side | 100 | __ | 10-32 | Side | 1 1/8" | 9/16" | 0.5 to 10 | 00000000 | 00000 |
Compact Compressed Air Regulators

A lower profile than our other compressed air regulators makes these regulators a better fit in tight spots. Use them to adjust and maintain the pressure of your compressed air. Install in your air line after filters.
Relieving regulators exhaust when the downstream pressure exceeds the set pressure.
Mounting brackets allow you to attach the regulator to a wall or equipment.
Regulators | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Overall | Mounting Brackets | |||||||||||
Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Gauge Included | Wd. | Ht. | Max. Temp., °F | Regulating Accuracy | Pressure Regulating Range, psi | Each | Each | ||
Zinc Housing—BSPP Female Inlet and Outlet | |||||||||||||
1/8 | 1/8 | 14 scfm @ 100 psi | 300 | Yes | 1 5/8" | 3" | 150° | ±3 psi | 1-10 | 0000000 | 000000 | 0000000 | 000000 |
1/4 | 1/4 | 15 scfm @ 100 psi | 300 | Yes | 1 5/8" | 3" | 150° | ±3 psi | 1-10 | 0000000 | 00000 | 0000000 | 00000 |
Zinc Housing—NPT Female Inlet and Outlet | |||||||||||||
1/8 | 1/8 | 14 scfm @ 100 psi | 300 | Yes | 1 5/8" | 3" | 150° | ±3 psi | 1-10 | 0000000 | 00000 | 0000000 | 00000 |
1/4 | 1/4 | 15 scfm @ 100 psi | 300 | Yes | 1 5/8" | 3" | 150° | ±3 psi | 1-10 | 0000000 | 00000 | 0000000 | 00000 |
High-Flow Precision Compressed Air Regulators
With a greater flow capacity than our standard precision compressed air regulators, use these regulators to adjust and maintain air pressure in sensitive high-flow applications where constant, consistent pressure is important. Install in your air line after filters.
Relieving regulators exhaust when the downstream pressure exceeds the set pressure.
Nonrelieving regulators do not exhaust excess downstream pressure.
Pressure gauges are for use with regulators with NPT threading.
Mounting brackets (sold separately) allow you to attach the regulator to a wall or equipment.


Regulators | ||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Overall | Mounting Brackets | ||||||||||||
Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Gauge Included | No. of Gauge Ports | Wd. | Ht. | Max. Temp., °F | Regulating Accuracy | Pressure Regulating Range, psi | Each | Each | ||
Aluminum Housing—NPT Female Inlet and Outlet | ||||||||||||||
Relieving | ||||||||||||||
1/4 | 1/4 | 100 scfm @ 100 psi | 250 | No | 2 | 4" | 7 5/8" | 200° | ±0.1% | 0-10 | 00000000 | 0000000 | 00000000 | 000000 |
1/2 | 1/2 | 225 scfm @ 100 psi | 250 | No | 2 | 4" | 7 5/8" | 200° | ±0.1% | 0-10 | 00000000 | 000000 | 00000000 | 00000 |
3/4 | 3/4 | 250 scfm @ 100 psi | 250 | No | 2 | 4" | 7 5/8" | 200° | ±0.1% | 0-10 | 00000000 | 000000 | 00000000 | 00000 |
Nonrelieving | ||||||||||||||
3/4 | 3/4 | 250 scfm @ 100 psi | 250 | No | 2 | 4" | 7 5/8" | 200° | ±0.1% | 0-10 | 00000000 | 000000 | 00000000 | 00000 |
Versa-Mount Precision Compressed Air Regulators

Mount these regulators to a 35 mm DIN rail or a wall with one of the two included brackets. With an accuracy of ±0.2%, use these regulators to adjust and maintain air pressure in sensitive applications where constant, consistent pressure is important. All are relieving regulators, so they exhaust when the downstream pressure exceeds the set pressure. Install in your air line after filters.
Pipe Size | Overall | |||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inlet | Outlet | Max. Flow Rate | Max. Pressure, psi | Gauge Included | No. of Gauge Ports | For DIN Rail Ht., mm | Wd. | Ht. | Max. Temp., °F | Includes | Regulating Accuracy | Pressure Regulating Range, psi | Each | |
Aluminum Housing | ||||||||||||||
NPT Female Inlet and Outlet | ||||||||||||||
1/4 | 1/4 | 40 scfm @ 100 psi | 250 | No | 2 | 35 | 2 1/4" | 5 1/2" | 200° | DIN-Rail Mounting Bracket, Wall Mounting Bracket | ±0.2% | 0-10 | 000000 | 0000000 |
1/4 | 1/4 | 60 scfm @ 100 psi | 500 | No | 1 | 35 | 3" | 7" | 200° | DIN-Rail Mounting Bracket, Wall Mounting Bracket | ±0.2% | 0-10 | 000000 | 000000 |
3/8 | 3/8 | 40 scfm @ 100 psi | 250 | No | 2 | 35 | 2 1/4" | 5 1/2" | 200° | DIN-Rail Mounting Bracket, Wall Mounting Bracket | ±0.2% | 0-10 | 000000 | 000000 |
3/8 | 3/8 | 60 scfm @ 100 psi | 500 | No | 1 | 35 | 3" | 7" | 200° | DIN-Rail Mounting Bracket, Wall Mounting Bracket | ±0.2% | 0-10 | 000000 | 000000 |
1/2 | 1/2 | 60 scfm @ 100 psi | 500 | No | 1 | 35 | 3" | 7" | 200° | DIN-Rail Mounting Bracket, Wall Mounting Bracket | ±0.2% | 0-10 | 000000 | 000000 |