About Pipe Size
More
About Pressure Gauges
More
High-Accuracy Low-Pressure Gauges




Measure small pressure changes in ventilation systems, hydraulic applications, and other critical processes with these high-accuracy gauges. Mount them with the dial face upright.
Gauges with 304 stainless steel case or polyester plastic case have better corrosion resistance than gauges with steel case.
- For Use With: Air, Water, Hydraulic Fluid, Carbon Dioxide, and Natural Gas
- Accuracy: ±1.5% Full Scale (Not Graded)
Available Pressure Gauges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
0 to 3 | 0.05 | 0.5 |
Bottom Connection | Center Back Connection | ||||||||
---|---|---|---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Case Color | Mounting Orientation | Each | Each | ||
NPT Male | |||||||||
2 1/2" | 1/4 | 0° to 140° | 0° to 140° | Black | Upright | 0000000 | 000000 | 0000000 | 000000 |
NPT Male with Calibration Certificate Traceable to NIST | |||||||||
2 1/2" | 1/4 | 0° to 140° | 0° to 140° | Black | Upright | 0000000 | 000000 | 0000000 | 000000 |
- For Use With: Air, Water, Hydraulic Fluid, Carbon Dioxide, and Natural Gas
- Accuracy: ±1% Full Scale (Grade 1A)
Available Pressure Gauges | ||
---|---|---|
Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
0 to 3 | 0.05 | 0.5 |
Bottom Connection | ||||||
---|---|---|---|---|---|---|
Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Mounting Orientation | Each | |
NPT Male | ||||||
4" | 1/4 | 0° to 140° | 0° to 140° | Upright | 000000 | 0000000 |
Low-Pressure Differential Gauges with Color Indicator
A band of green, yellow, and red provides a clear indication of changes in differential pressure. Gauges are commonly used to indicate clogged filters.

- For Use With: Air, Water, Hydraulic Fluid, Carbon Dioxide, Nitrogen, Hydrogen, Argon, and Acetylene
- Accuracy: ±5% Full Scale (Not Graded)
Pressure Range, psi | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Pipe Size | Green Band | Yellow Band | Red Band | Max. Pressure, psi | Environment Temp. Range, °F | Process Temp. Range, °F | Ht. | Wd. | Dp. | Case Color | Each | |
NPT Female | ||||||||||||
1/4 | 0-3 | 3-4.5 | 4.5-5 | 300 | -40° to 200° | -40° to 200° | 3 1/4" | 3 1/4" | 1 1/2" | Black | 0000000 | 0000000 |
High-Accuracy Digital Test Gauges for Pressure



Not only do these gauges have an accuracy of ±0.25%, they also have a four-digit LCD display that allows for easy reading of measurements. Use them for testing, calibrating, laboratory applications, and other critical applications that require precision.
Gauges with 4-20mA current output convert pressure to an electrical signal for remote monitoring.
- For Use With: See Table
- Accuracy: ±0.25% Full Scale (Not Graded)
Available Pressure Ranges | |||
---|---|---|---|
Pressure Range | |||
psi | bar | MPa | Resolution, psi |
0 to 3 | 0 to 1 | 0 to 1.4 | 0.01 |
Dial | Bottom Connection | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Pipe Size | Environment Temperature Range, °F | Process Temperature Range, °F | Environment | For Use With | Features | Digit Ht. | Batteries Included | Each | |
NPT Male | |||||||||||
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | __ | Air, Hydraulic Fluid, Water | 5-min. Automatic Shut-Off | 1/2" | Yes | 0000000 | 0000000 |
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | Hazardous Location | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water | 5-min. Automatic Shut-Off | 1/2" | Yes | 0000000 | 000000 |
NPT Male—Calibration Certificate Traceable to NIST | |||||||||||
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | __ | Air, Hydraulic Fluid, Water | 5-min. Automatic Shut-Off | 1/2" | Yes | 0000000 | 000000 |
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | Hazardous Location | Air, Diesel Fuel, Gasoline, Hydraulic Fluid, Natural Gas, Water | 5-min. Automatic Shut-Off | 1/2" | Yes | 0000000 | 000000 |
- For Use With: See Table
- Accuracy: ±0.25% Full Scale (Not Graded)
Available Pressure Ranges | |||
---|---|---|---|
Pressure Range | |||
psi | bar | MPa | Resolution, psi |
0 to 3 | 0 to 1 | 0 to 1.4 | 0.01 |
Dial | Bottom Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Pipe Size | Environment Temperature Range, °F | Process Temperature Range, °F | For Use With | Digit Ht. | Wire Connection Type | Input Voltage | Each | |
NPT Male | ||||||||||
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | Air, Hydraulic Fluid, Water | 1/2" | Wire Leads | 8-24V AC, 9-32V DC | 0000000 | 0000000 |
NPT Male—Calibration Certificate Traceable to NIST | ||||||||||
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | Air, Hydraulic Fluid, Water | 1/2" | Wire Leads | 8-24V AC, 9-32V DC | 0000000 | 000000 |
- For Use With: See Table
- Accuracy: ±0.25% Full Scale (Not Graded)
- Environmental Rating: 0 to 1,000 psi: NEMA 2, All other psi ranges: NEMA 4X
Available Pressure Ranges | |
---|---|
Pressure Range, psi | Resolution, psi |
0 to 3 | 0.01 |
Dial | Bottom Connection | |||||||||
---|---|---|---|---|---|---|---|---|---|---|
Ht. | Wd. | Pipe Size | Environment Temperature Range, °F | Process Temperature Range, °F | For Use With | Digit Ht. | Wire Connection Type | Input Voltage | Each | |
NPT Male | ||||||||||
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | Air, Hydraulic Fluid, Water | 1/2" | Wire Leads | 8-32V DC | 0000000 | 0000000 |
NPT Male—Calibration Certificate Traceable to NIST | ||||||||||
2 7/8" | 3 3/8" | 1/4 | 0° to 185° | -40° to 200° | Air, Hydraulic Fluid, Water | 1/2" | Wire Leads | 8-32V DC | 0000000 | 000000 |