About Pipe Size
More
About Pressure Gauges
More
Gas Pressure Gauges






Use these gauges with pumps, filters, regulators, and in process lines to monitor the pressure of compressed gas. Mount them with the dial face upright. Gauges for use with acetylene can also be used in welding applications.
Gauges with brass case are cleaned to meet ASME B40.1, Level IV for oxygen service.
Gauges with 304 stainless steel case are cleaned and bagged to meet ASME B40.1, Level IV for oxygen service.
- For Use With: Air, Acetylene, Carbon Dioxide, and Oxygen
- Accuracy: ±2% Mid Scale (Grade B)
Available Pressure Ranges | ||
|---|---|---|
| Pressure Range, psi | Graduation Marks, psi | Numeric Increments, psi |
| 0 to 30 | 1 | 5 |
| 0 to 60 | 1 | 10 |
| 0 to 100 | 2 | 20 |
| 0 to 200 | 5 | 40 |
| 0 to 400 | 10 | 50 |
| 0 to 600 | 10 | 100 |
| 0 to 1,000 | 20 | 200 |
| 0 to 2,000 | 50 | 400 |
| 0 to 3,000 | 50 | 500 |
| 0 to 4,000 | 100 | 500 |
- For Use With: Oxygen
- Accuracy: ±1% Mid Scale (Grade A); except
4" Dial Dia.: ±1% Full Scale (Grade 1A)
Available Pressure Ranges | |||||||||
|---|---|---|---|---|---|---|---|---|---|
Bottom and Center Back Connections | Lower Back Connection | ||||||||
Pressure Range | Graduation Marks | Numeric Increments | Graduation Marks | Numeric Increments | |||||
| psi | kPa | psi | kPa | psi | kPa | psi | kPa | psi | kPa |
2 1/2" Dial Diameter | |||||||||
| 0 to 15 | 0 to 102 | 0.2 | 2 | 3 | 20 | __ | __ | __ | __ |
| 0 to 30 | 0 to 205 | 0.5 | 5 | 5 | 50 | __ | __ | __ | __ |
| 0 to 100 | 0 to 680 | 2 | 10 | 20 | 100 | __ | __ | __ | __ |
| 0 to 200 | 0 to 1,350 | 5 | 50 | 50 | 200 | __ | __ | __ | __ |
| 0 to 300 | 0 to 2,050 | 5 | 50 | 50 | 500 | __ | __ | __ | __ |
| 0 to 600 | 0 to 4,100 | 10 | 100 | 100 | 1,000 | __ | __ | __ | __ |
4" Dial Diameter | |||||||||
| 0 to 15 | 0 to 103 | 0.2 | 1 | 3 | 10 | 0.2 | 1 | 3 | 10 |
| 0 to 30 | 0 to 206 | 0.5 | 2 | 5 | 20 | 0.5 | 2 | 5 | 20 |
| 0 to 100 | 0 to 680 | 1 | 10 | 10 | 100 | 1 | 10 | 10 | 100 |
| 0 to 200 | 0 to 1,360 | 2 | 20 | 20 | 200 | 2 | 20 | 20 | 200 |
| 0 to 300 | 0 to 2,060 | 5 | 20 | 50 | 200 | 5 | 20 | 50 | 200 |
| 0 to 600 | 0 to 4,100 | 10 | 50 | 100 | 500 | 10 | 100 | 100 | 1,000 |
| Dial Diameter | Pipe Size | Environment Temp. Range, °F | Process Temp. Range, °F | Mounting Orientation | Each | |
Bottom Connection | ||||||
|---|---|---|---|---|---|---|
NPT Male | ||||||
| 2 1/2" | 1/4 | -40° to 140° | -40° to 140° | Upright | 0000000 | 000000 |
| 4" | 1/4 | -40° to 140° | -40° to 140° | Upright | 0000000 | 00000 |
Center Back Connection | ||||||
NPT Male | ||||||
| 2 1/2" | 1/4 | -40° to 140° | -40° to 140° | Upright | 0000000 | 00000 |
Lower Back Connection | ||||||
NPT Male | ||||||
| 4" | 1/4 | -40° to 140° | -40° to 140° | Upright | 0000000 | 00000 |
Panel-Mount Ultra-High-Pressure-Regulating Valves for Air and Inert Gas

- For Use With: Air, Nitrogen, Argon, Helium
- Temperature Range: -40° to 165° F
These valves are rated for inlet pressures up to 6,000 psi. They automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Threads below the adjustment knob and an included mounting bracket let you install these valves in instrument panels. They have two gauge ports. An internal strainer traps debris.
Inlet | Outlet | Gauge Port | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | Pipe Size | Location | End-to-End Lg. | Panel Cutout Dia. | Specifications Met | Choose an Outlet Pressure Range, psi | Each | |
NPT Female | ||||||||||||
Brass Body—Polyimide Seal | ||||||||||||
| 1/4 | Side | 6,000 | 1/4 | Side | 1/4 | Side | 2 1/8" | 2 1/4" | ASME B31.3 | 0000000 | 000000000 | |
Panel-Mount High-Pressure-Regulating Valves for Air and Inert Gas

- For Use With: Air, Nitrogen, Argon, Helium
- Temperature Range: -40° to 165° F
Withstand inlet pressures up to 3,500 psi. These valves automatically reduce a high, variable inlet pressure to a lower, stable outlet pressure. Adjust the outlet pressure within the range. Valves have threads below the adjustment knob and come with a panel-mount nut. All have two gauge ports. An internal strainer traps debris.
Inlet | Outlet | Gauge Port | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Pipe Size | Location | Max. Pressure, psi | Pipe Size | Location | Pipe Size | Location | End-to-End Lg. | Panel Cutout Dia. | Specifications Met | Choose an Outlet Pressure Range, psi | Each | |
NPT Female | ||||||||||||
Brass Body—316 Stainless Steel Diaphragm and PTFE Seal | ||||||||||||
| 1/4 | Side | 3,500 | 1/4 | Side | 1/4 | Side | 2" | 1 3/8" | ASME B31.3 | 0000000 | 0000000 | |
Remote-Reading Tension Force Gauges



Safely view your tension force measurements on a handheld receiver up to 450 ft. away when moving bulk material with cranes and hoists. These gauges are also called dynamometers and crane scales. Made of steel, they’re durable enough to briefly hold heavy loads up to 500% of their capacity. But, they will no longer take measurements if the load exceeds 200%. Warning lights will flash first when your load exceeds capacity, then again when it reaches 133% capacity. To prevent overloads, the peak-hold setting displays the highest measurement. The tare function lets you reset the gauge to zero after attaching a container to weigh only the material inside. These gauges include a calibration certificate traceable to NIST that states they’ve passed a test for accuracy. They also meet IEC and ASME safety and fatigue standards.
Because their indicators and load cells are IP rated, these gauges stand up to washdowns and brief submersion common to food and chemical plants. They’re also safe to use outdoors since they’re NEMA rated to seal out weather.
These gauges come with two shackles that work with other lifting fittings, such as clevis hooks. The included batteries power their load cells for up to 2,000 hours.
Capacity | Accuracy | Measuring Increments | Shackle | Temp. Range, °F | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| English | Metric | Newtons | English | Metric | Newtons | English | Metric | Newtons | Ht. | Wd. | Dp. | Opening Ht. | Opening Wd. | Load Point | Remote Receiver | Each | |
Gauges | |||||||||||||||||
| 2,000 lbs. | 900 kg | 8,800 N | ±2 lbs. | ±1 kg | ±9 N | 1 lbs. | 0.5 kg | 5 N | 4 7/8" | 4" | 3 1/4" | 1 3/8" | 1" | -15° to 175° | 0° to 155° | 0000000 | 000000000 |
| 4,000 lbs. | 1,800 kg | 17,700 N | ±4 lbs. | ±2 kg | ±18 N | 2 lbs. | 1 kg | 9 N | 4 7/8" | 4" | 3 1/4" | 1 3/8" | 1" | -15° to 175° | 0° to 155° | 0000000 | 00000000 |
| 10,000 lbs. | 4,500 kg | 44,400 N | ±10 lbs. | ±5 kg | ±45 N | 5 lbs. | 2 kg | 23 N | 5 3/8" | 4" | 3 1/4" | 2 3/8" | 1 3/4" | -15° to 175° | 0° to 155° | 0000000 | 00000000 |
| 20,000 lbs. | 9,000 kg | 88,900 N | ±20 lbs. | ±9 kg | ±89 N | 10 lbs. | 5 kg | 45 N | 7 3/4" | 4" | 4 5/8" | 3 3/4" | 2 5/8" | -15° to 175° | 0° to 155° | 0000000 | 00000000 |
| 50,000 lbs. | 22,600 kg | 222,400 N | ±50 lbs. | ±23 kg | ±222 N | 10 lbs. | 5 kg | 50 N | 9 3/8" | 4" | 4 5/8" | 5 3/4" | 3 55/64" | -15° to 175° | 0° to 155° | 0000000 | 00000000 |