    51 Products

    Dual-Setpoint Electronic Pressure Switches with Digital Display

    Image of Product. Front orientation. Contains Inset. Pressure Switches. Dual-Setpoint Electronic Pressure Switches with Digital Display.
    Image of Specification. 4-Pole M12 Plug. Front orientation. Pressure Switches. Dual-Setpoint Electronic Pressure Switches with Digital Display.

    4-Pole

    M12

    Plug

    When these switches reach either of their two set pressures—both of which can be controlled from the display—they send digital signals to your programmable logic controller (PLC) to activate automated controls. This means you could turn on a pump at one setpoint if pressure drops too low and open a valve at another if pressure rises too high. These switches could also be used to signal an alarm before switching off a pump. For remote control and monitoring from your PLC or PC, connect an IO Link controller (not included). You’ll also need to set one of the outputs to use IO Link instead of a PNP or NPN signal.
    Change your setpoint, reset point, scaling, and other settings using the display’s buttons. An adjustable reset point means you can control the amount of pressure change before the switch resets, also known as deadband or differential. Choose anywhere within the setpoint range for your reset point. The head rotates, so you can view the display from the best angle. To reduce stress on pipes in your pressure system, secure these switches against a wall or other structure with a mounting bracket (sold separately). Use these switches with an M12 cable (sold separately) to quickly connect and disconnect them.
    All are rated IP65 and IP67, so they seal out dust and water from washdowns and brief submersion. UL and C-UL listed, all meet U.S. and Canadian safety standards.
    Configurable
    Digital Output
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Signal
    Output
    Communication
    Protocol
    Accuracy
    Max. Switching
    Current @ Voltage
    Process Temp.
    Range, ° F
    Connection Material
    Measurement Unit
    For Use With
    Each
    M12 Connection with 4 Poles
     
    1/4 NPT Male Pipe
    0 to 14Adjustable145PNP, NPNIO Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Inches of Mercury, Kilopascals, Millibars, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water3167K310000000
    0 to 36Adjustable290PNP, NPNIO Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Bar, Kilopascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water3167K32000000
    0 to 360Adjustable1,015PNP, NPNIO Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Bar, Kilopascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water6360N11000000
    0 to 1,450Adjustable1,810PNP, NPNIO Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Bar, Kilopascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water6360N12000000
    0 to 3,600Adjustable7,250PNP, NPNIO Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Bar, Kilopascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water6360N13000000
    0 to 5,800Adjustable11,580PNP, NPNIO Link±0.2%35 mA @ 30V DC-10 to 175316L Stainless Steel
    Bar, Kilopascals, Pounds per Square InchAir, Argon, Diesel Fuel, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Water6360N14000000
     
    Accessories for Pressure Switches

    Electronic Pressure Switches

    When these switches reach a set pressure, they send electronic signals to your programmable logic controller (PLC) to activate automated controls or alarms. Easily adjust the setpoint by twisting the external ring. An indicating pointer and incremental markings make sure adjustments are precise. When you have your setpoint, tighten the locking ring to prevent unintentional changes. Pair these switches with an M12 socket to quickly connect and disconnect them.
    Rated IP67, these switches seal out dust and water from temporary submersion. All are UL and C-UL listed as well as CE marked, which means they meet U.S., Canadian, and European safety standards.
    1 Circuit Controlled—1 Off (Normally Open)
    Image of Product. Front orientation. Pressure Switches. Electronic Pressure Switches, 1 Circuit Controlled.
    Image of Attribute. Front orientation. Electronic Pressure Switches.

    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Signal
    Output
    Accuracy
    Max. Switching Current
    @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    M12 Connection with 4 Pins
     
    1/4 BSPP Male Pipe
    7.5 to 1452.9360360PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N190000000
    11 to 3637.2870870PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N23000000
    44 to 1,450292,9002,900PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N22000000
    109 to 3,625725,8005,800PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N21000000
    175 to 5,8001168,7008,700PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N24000000
     
    BSPP to NPT Thread Adapter
    2 Circuits Controlled—1 Off (Normally Open) and 1 On (Normally Closed)
    Image of Product. Front orientation. Pressure Switches. Electronic Pressure Switches, 2 Circuits Controlled.
    Image of Attribute. Front orientation. Electronic Pressure Switches.

    Switches for two circuits function like single pole, double throw (SPDT) switches. When the switches reach the setpoint, they turn one circuit from off to on (normally open) and another from on to off (normally closed). They have an adjustable reset, which means you can control the amount of pressure change before the switch resets. This pressure difference is commonly referred to as deadband and differential. Use the second external ring to change the reset point anywhere along the setpoint range.
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Signal
    Output
    Accuracy
    Max. Switching Current
    @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Each
    M12 Connection with 4 Pins
     
    1/4 NPT Male Pipe
    7.5 to 145Adjustable360360PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N110000000
    75 to 1,450Adjustable2,9002,900PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N12000000
    290 to 5,800Adjustable8,7008,700PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N13000000
     
    1/4 BSPP Male Pipe
    7.5 to 145Adjustable360360PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N14000000
    18 to 363Adjustable870870PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N18000000
    75 to 1,450Adjustable2,9002,900PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N16000000
    181 to 3,625Adjustable5,8005,800PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N15000000
    290 to 5,800Adjustable8,7008,700PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    4064N17000000
     
    BSPP to NPT Thread Adapter

    Dual-Setpoint Electronic Pressure Switches

    Send two digital signals to your programmable logic controller (PLC) to trigger different processes—these switches activate at two set pressures. For example, you can turn on one pump to empty a tank when the pressure rises too high and another to fill the tank when the pressure drops too low. They could also be used to signal an alarm before switching off a pump. Twist the external rings to adjust each setpoint. Indicator markings and pointer make precise adjustments in the field easy. Avoid accidental changes to the setpoints by tightening the setpoint locking ring. Pair these switches with an M12 socket to quickly connect and disconnect them.
    All switches are rated IP67, so they’re protected from dust and temporary submersion. UL and C-UL listed as well as CE marked, all meet U.S., Canadian, and European safety standards.
    M12 Connection with 4 Poles
    Image of Product. Front orientation. Pressure Switches. Dual-Setpoint Electronic Pressure Switches.
    Image of Attribute. Front orientation. Pressure Switches. Dual-Setpoint Electronic Pressure Switches.
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Signal
    Output
    Accuracy
    Max. Switching Current
    @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Enclosure
    Rating
    Certification
    Each
    1/4 Threaded BSPP Male Pipe
     
    External Adjustment
    4 1/2 to 1452.9360360PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    C-UL Listed, CE Marked, UL Listed
    4064N260000000
    45 to 1,450292,9002,900PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    C-UL Listed, CE Marked, UL Listed
    4064N27000000
    109 to 3,625725,8005,800PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    C-UL Listed, CE Marked, UL Listed
    4064N25000000
    174 to 5,8001168,7008,700PNP±2.5%500 mA @ 32V DC-10 to 175316 Stainless SteelAir, Diesel Fuel, Hydraulic Fluid, Oil, WaterIP67
    C-UL Listed, CE Marked, UL Listed
    4064N28000000
     
    BSPP to NPT Thread Adapter

    Differential Pressure Transmitters with Electronic Switch Outputs

    Image of Product. Front orientation. Differential Pressure Transmitters. Differential Pressure Transmitters with Electronic Switch Outputs.
    Get the flexibility of a differential pressure transmitter and a switch in one. These transmitters can work as a traditional transmitter using an analog output but also have electronic switch outputs and IO Link compatibility, making them great for advanced automation applications. Also known as transducers, they measure the difference in pressure between two inputs and convert it to electrical signal. Connect them to your programmable logic controller or receiving device to monitor differential pressure remotely, activate automated controls, or trigger alarms when they reach the set pressure. A digital display lets you monitor the differential pressure and troubleshoot issues at the source. It rotates for readability.
    You’ll often see these transmitters used to indicate a clogged filter or help maintain a certain pressure in HVAC systems, pumps, and cooling systems. NEMA and IP rated, they protect against dirt, dust, corrosion, weather, washdowns, and temporary submersion.
    For your receiving device to interpret the signal from the transmitter, you will need to calibrate it for the transmitter's differential pressure range and output signal. As differential pressure increases, the output signal from the transmitter will increase. Transmitters will only provide accurate readings within the rated pressure range.
    Configurable Analog
    Transmitter Output
    Configurable
    Digital Switch Output
    Mounting
    Holes
    Connection
    Pressure Differential,
    psi
    Max. Input
    Pressure, psi
    Input Voltage,
    V DC
    Pipe
    Size
    Ht.
    Wd.
    No.
    of
    Signal
    No.
    of
    Signal
    Type
    Mounting Hardware
    Included
    Dia.
    No.
    of
    Enclosure Rating
    For Use With
    Accuracy
    Pipe
    Material
    Temp. Range,
    ° F
    Each
    5 Poles M12 Plug In
     
    Glass-Filled Polyester Plastic Housing
    0 to 152,50015 to 321/4
    4 13/16"3"10 to 10V DC, 4 to 20 mA2PNP, NPNNo3/16"2IP65, IP67, NEMA 4X, NEMA 6
    Air, Hydraulic Fluid, Water±0.5%NPT Female316L Stainless Steel
    14 to 1584682N11000000000
    0 to 1002,50015 to 321/4
    4 13/16"3"10 to 10V DC, 4 to 20 mA2PNP, NPNNo3/16"2IP65, IP67, NEMA 4X, NEMA 6
    Air, Hydraulic Fluid, Water±0.5%NPT Female316L Stainless Steel
    14 to 1584682N1200000000
    0 to 5002,50015 to 321/4
    4 13/16"3"10 to 10V DC, 4 to 20 mA2PNP, NPNNo3/16"2IP65, IP67, NEMA 4X, NEMA 6
    Air, Hydraulic Fluid, Water±0.5%NPT Female316L Stainless Steel
    14 to 1584682N1300000000
     

    Electronic Insertion-Mount Flow Switches

    Image of Product. Front orientation. Flow Switches. Electronic Insertion-Mount Flow Switches.
    Instead of disassembling your system for inline installation, thread these flow switches onto a mounting adapter (sold separately) and insert them into a pipe tee or pipe outlet. They send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms when they reach a set flow rate. To calculate the flow rate, they generate a small amount of heat, then measure the cooling effect your liquid or gas has on it. This makes them ideal in applications with fluctuating temperatures. Use the buttons on the display to adjust the set point and other settings. These switches are accurate in any mounting position.
    IP65 rated switches protect against dust and washdowns. IP67 rated switches withstand temporary submersion.
    Flow Set Point
    1 13/16"
    Probe Length
    For Pipe Size
    For Liquids, gpm
    For Gas, scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage,
    V DC
    Max. Switching Current
    @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Certification
    Each
    304 Stainless Steel Body with 316 Stainless Steel Fittings
     
    1 Digital NPN Signal Output
    1/4
    1/2
    3/4
    1
    0.02 to 1.5
    0.05 to 4.9
    0.13 to 12.7
    0.23 to 23
    0.14 to 2
    0.54 to 8.05
    1.21 to 18.11
    2.15 to 32.21
    4,300 psi @ 70° F-10 to 17536250 mA @ 19V DC
    250 mA @ 36V DC
    2 11/16"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    4547N130000000
     
    1 Digital PNP Signal Output
    1/4
    1/2
    3/4
    1
    0.02 to 1.5
    0.05 to 4.9
    0.13 to 12.7
    0.23 to 23
    0.14 to 2
    0.54 to 8.05
    1.21 to 18.11
    2.15 to 32.21
    4,300 psi @ 70° F-10 to 17536250 mA @ 36V DC
    250 mA @ 18V DC
    2 11/16"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    4547N11000000
     
    2 Digital NPN Signal Output
    1/4
    1/2
    3/4
    1
    0.02 to 1.5
    0.05 to 4.9
    0.13 to 12.7
    0.23 to 23
    0.14 to 2
    0.54 to 8.05
    1.21 to 18.11
    2.15 to 32.21
    4,300 psi @ 70° F-10 to 17536250 mA @ 19V DC
    250 mA @ 36V DC
    2 11/16"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    4547N14000000
     
    2 Digital PNP Signal Output
    1/4
    1/2
    3/4
    1
    0.02 to 1.5
    0.05 to 4.9
    0.13 to 12.7
    0.23 to 23
    0.14 to 2
    0.54 to 8.05
    1.21 to 18.11
    2.15 to 32.21
    4,300 psi @ 70° F-10 to 17536250 mA @ 36V DC
    250 mA @ 18V DC
    2 11/16"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    4547N12000000
     
    Mounting Adapters

    Electronic Flow Switches

    Image of Product. Front orientation. Flow Switches. Electronic Flow Switches.
    When these switches reach a set flow rate, they send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms. Use the adjustment screw to select their set point. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. They must be mounted horizontally to function correctly. IP rated, they withstand dust, washdowns, and temporary submersion.
    These switches are calibrated with and measure water accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Pipe
    Connections
    Flow Set Point,
    gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage,
    V DC
    Max. Switching Current
    @ Voltage
    End-to-End
    Lg.
    Enclosure
    Rating
    Certification
    Each
    Aluminum/Brass/Plastic Body with Threaded Nickel-Plated Brass Fittings
     
    1 PNP Signal Output
    3/4 NPT Female0.26 to 6.6360 psi @ 70° F32 to 18530100 mA @ 30V DC3"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    4546N110000000
    1 NPT Female1.32 to 26.4360 psi @ 70° F32 to 18530100 mA @ 30V DC3 5/8"IP65, IP67
    C-UL Listed
    UL Listed
    CE Marked
    4546N12000000
     

    High-Pressure Flow Switches for Oil

    Image of Product. Front orientation. Contains Annotated. Flow Switches. High-Pressure Flow Switches for Oil.
    Measure the flow rate of oil at pressures up to 3,600 psi to activate or deactivate equipment. Designed to compensate for viscosity and density changes, these switches have an adjustment screw to select your specific flow rate within the set point range. As flowing liquid pushes an internal piston, the switch reads the position of the piston to measure the flow. When the piston passes the set point, the switch actuates. These switches are single pole, double throw (SPDT) and can turn one device from off to on (normally open) or from on to off (normally closed). Their IP65 rating protects them from dust and low-pressure washdowns, such as from a garden hose. All are accurate in any mounting position.
    These switches are calibrated with and measure oil accurately. They can also be used with other liquids by applying your liquid’s specific-gravity conversion factor to calculate the new set point.
    Pipe
    Connections
    Flow Set Point,
    gpm
    Approx. Difference Between Set
    Point and Reset Point
    Max. Pressure
    @ Temp.
    Max. Temp.,
    ° F
    Max. Switching Current @ Voltage
    Port-to-Port
    Lg.
    Enclosure
    Rating
    Each
    SPDT
     
    Brass Body with Brass Fittings
    1/4 NPT Female0.03 to 0.12Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    4562N110000000
    1/4 NPT Female0.05 to 0.3Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    4562N12000000
    1/4 NPT Female0.2 to 0.9Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    4562N13000000
    1/4 NPT Female0.5 to 2.5Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    4562N14000000
    1/2 NPT Female1.5 to 5Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    4562N15000000
    3/4 NPT Female1 to 11Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    4562N16000000
    3/4 NPT Female2 to 18Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    6 3/8"IP65
    4562N17000000
    1 NPT Female2 to 20Adjustable3,600 psi @ 70° F2121 amp @ 100V AC
    0.42 amp @ 240V AC
    1 amp @ 60V DC
    0.26 amp @ 230V DC
    7 5/16"IP65
    4562N18000000
     

    Sanitary Electronic Insertion-Mount Flow Switches

    Image of Product. Front orientation. Flow Switches. Sanitary Electronic Insertion-Mount Flow Switches.
    Easy to clean and install, these flow switches are 3-A certified to meet sanitary design standards and insert into your line with a quick-clamp mounting adapter (sold separately). They have a smooth probe, and unlike flow switches that measure with a paddle or turbine, these don’t have moving parts for contaminants to get stuck in. Rated IP67 and IP69K, they withstand temporary submersion and high-temperature, high-pressure washdowns. The mounting adapter attaches to a quick-clamp tube tee or outlet (often called tri-clamp fittings) in your large-diameter tubing system using a gasket and clamp (not included), so you don't need to disassemble your line for inline installation. This mounting adapter is also easy to remove and clean.
    They send digital signals to your programmable logic controller (PLC) to activate automated controls or alarms when they reach a set flow rate. To calculate the flow rate, they generate a small amount of heat, then measure the cooling effect your liquid or gas has on it. This makes them ideal in applications with fluctuating temperatures. Use the buttons on the display to adjust the set point and other settings. They’re accurate in any mounting position.
    Flow Set Point
    13/16"
    Probe Length
    1 13/16"
    Probe Length
    For Tube
    OD
    For Liquids, gpm
    For Gas, scfm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage,
    V DC
    Max. Switching Current
    @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Certification
    Food Industry Std.
    Each
    Each
    316 Stainless Steel Body with 316 Stainless Steel Fittings
     
    1 Digital PNP Signal Output
    1 1/2"
    2"
    0.55 to 54.21
    0.97 to 96.37
    4.84 to 72.47
    8.59 to 128.84
    430 psi @ 70° F-10 to 20036250 mA @ 19V DC
    250 mA @ 36V DC
    3 5/16"IP67, IP69K
    C-UL Listed
    UL Listed
    CE Marked
    3-A Certified 74-07, FDA Compliant 21 CFR 177.2415
    4548N1100000004548N120000000
     
    Mounting Adapters
    back to top