    44 Products

    Pressure Switches

    Image of Product. Style A. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style A.
    Image of Product. Style F. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style F.

    Style A

    Style F

    The traditional pressure switch. These power equipment, activate controls or alarms, or kick-off other actions when they reach a set pressure. Larger than compact pressure switches, they're easier to wire. These switches are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed).
    Pressure Switches
    Image of Product. Style A. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style A.

    Style A

    Style A—Styles A-C, E-J, and L meet at least one safety standard.
    Style
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use With
    Each
    Screw-Terminal Wire Connection
     
    1/4 Threaded NPT Male Pipe
    A3 to 300.9550230±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    0 to 200AluminumAir, Hydraulic Fluid (Petroleum Based), Oil, Water3899N110000000
    A10 to 1001.5200300±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    0 to 200AluminumAir, Hydraulic Fluid (Petroleum Based), Oil, Water3899N12000000
    A30 to 3002.5400500±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    0 to 200AluminumAir, Hydraulic Fluid (Petroleum Based), Oil, Water3899N13000000
    A50 to 5003.5600700±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    0 to 200AluminumAir, Hydraulic Fluid (Petroleum Based), Oil, Water3899N14000000
     
    Pressure Switches with Cover
    Image of Product. Style F. Front orientation. Pressure Switches. Pressure Switches, Screw-Terminal Wire Connection, Style F.

    Style F

    Switches with a cover protect against impact and keep dust off the switch.
    Style F—Styles A-C, E-J, and L meet at least one safety standard.
    NEMA 4X Enclosure Rating—NEMA 4 and NEMA 4X rated switches can be used in dirty and wet areas exposed to washdowns and the weather. NEMA 4X also has increased protection against corrosion, similar to 304 stainless steel.
    Style
    Pressure Set
    Point Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection Material
    For Use With
    Enclosure
    Rating
    Each
    Screw-Terminal Wire Connection
     
    1/2 Threaded NPT Female Pipe
    F1 to 200.555001,000±1%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    -70 to 300316L Stainless SteelAir, Hydraulic Fluid, Oil, WaterNEMA 4X
    3899N150000000
    F5 to 3021,5002,500±1.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    -70 to 300316 Stainless SteelAir, Hydraulic Fluid, Oil, WaterNEMA 4X
    47515K71000000
    F10 to 1004.51,5002,500±1.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    -70 to 300316 Stainless SteelAir, Hydraulic Fluid, Oil, WaterNEMA 4X
    47515K72000000
    F15 to 300101,5002,500±1.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    -70 to 300316 Stainless SteelAir, Hydraulic Fluid, Oil, WaterNEMA 4X
    47515K73000000
    F20 to 500171,5002,500±1.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    -70 to 300316 Stainless SteelAir, Hydraulic Fluid, Oil, WaterNEMA 4X
    47515K74000000
    F80 to 1,700622,0002,500±1.5%15 amp @ 125V AC
    15 amp @ 250V AC
    15 amp @ 480V AC
    1 amp @ 30V DC
    30 mA @ 125V DC
    -70 to 300316 Stainless SteelAir, Hydraulic Fluid, Oil, WaterNEMA 4X
    47515K75000000
     

    Compact Pressure Switches

    With a round body that’s at least one-third thinner than traditional pressure switches, these fit in tight, cramped spaces. They’re often built into pumps and hydraulic systems with limited space in order to turn equipment on and off, activate automated controls, or signal alarms when they reach a set pressure. These switches are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). They also meet at least one American, Canadian, or European safety standard.
    Quick-Disconnect-Terminal Wire Connection
    Image of Product. Top orientation. Pressure Switches. Compact Pressure Switches, Quick-Disconnect-Terminal Wire Connection.
    Internal Adjustment—Switches with an internal setpoint adjustment have a sliding cover to prevent accidental setting changes.
    Pressure Set Point
    Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use
    With
    Certification
    Each
    1/8 Threaded NPT Male Pipe
     
    Internal Adjustment
    4 to 503.51,0003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K810000000
    10 to 15061,5003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K1000000
    30 to 600342,5003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K2000000
     
    1/4 Threaded NPT Male Pipe
     
    Internal Adjustment
    100 to 1,5001208,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K82000000
    180 to 3,0002258,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K3000000
    400 to 4,7003508,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K83000000
    4,000 to 7,50067510,00012,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterC-UL Recognized Component, CE Marked, UL Recognized Component
    3427K84000000
     
    Wire Lead Connection
    Image of Product. Front orientation. Pressure Switches. Compact Pressure Switches, Wire Lead Connection.
    Internal Adjustment—Switches with an internal setpoint adjustment have a sliding cover to prevent accidental setting changes.
    NEMA 4 Enclosure Rating—NEMA 4 rated switches stand up to dusty and washdown areas as well as the outdoor elements.
    Pressure Set Point
    Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use
    With
    Enclosure
    Rating
    Certification
    Each
    1/8 Threaded NPT Male Pipe
     
    Internal Adjustment
    4 to 503.51,0003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K850000000
    10 to 15061,5003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K4000000
    30 to 600342,5003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K5000000
     
    1/4 Threaded NPT Male Pipe
     
    Internal Adjustment
    100 to 1,5001208,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K86000000
    180 to 3,0002258,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K6000000
    400 to 4,7003508,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K87000000
    4,000 to 7,50067510,00012,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassAir, WaterNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K88000000
     

    Differential Pressure Switches for Air

    Image of Product. Front orientation. Differential Pressure Switches. Differential Pressure Switches for Air, Connects to Tube.

    Connects to

    Tube

    Often used with ovens, dryers, and HVAC systems, these switches detect small differences in air pressure to indicate a filter is clogged or help you maintain a certain air pressure. When the differential pressure reaches your setpoint, these switches can turn equipment on and off, activate automated controls, or signal alarms. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on or from on to off. All meet at least one safety standard.
    When measuring pressure in ductwork, pair them with a static pressure probe.
    IP54 Enclosure Rating—Switches rated IP54 protect against dust and splashing water.
    NEMA 13 Enclosure Rating— NEMA 13 rated switches can be used in dirty, wet, and oily areas.
    Pressure Set
    Point, in. H₂O
    Approx. Difference Between Set
    Point and Reset Point, in. H₂O
    Max. Input
    Pressure, in. H₂O
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use
    With
    Certification
    Enclosure
    Rating
    Each
    Screw-Terminal Wire Connection
     
    1/4" Barbed Male Tube Connection
    0.08 to 1.20.0540±1%1.5 amp @ 120V AC
    400 mA @ 250V AC
    0 to 185Nylon
    AirC-ETL Listed, ETL Listed
    IP54, NEMA 13
    3964N11000000
    0.12 to 1.60.0840±1%1.5 amp @ 120V AC
    400 mA @ 250V AC
    0 to 185Nylon
    AirC-ETL Listed, ETL Listed
    IP54, NEMA 13
    3964N1200000
    0.2 to 20.0940±1%1.5 amp @ 120V AC
    400 mA @ 250V AC
    0 to 185Nylon
    AirC-ETL Listed, ETL Listed
    IP54, NEMA 13
    3964N1300000
    0.8 to 40.4540±1%1.5 amp @ 120V AC
    400 mA @ 250V AC
    0 to 185Nylon
    AirC-ETL Listed, ETL Listed
    IP54, NEMA 13
    3964N1400000
    2 to 100.740±1%1.5 amp @ 120V AC
    400 mA @ 250V AC
    0 to 185Nylon
    AirC-ETL Listed, ETL Listed
    IP54, NEMA 13
    3964N1500000
    4 to 201.240±1%1.5 amp @ 120V AC
    400 mA @ 250V AC
    0 to 185Nylon
    AirC-ETL Listed, ETL Listed
    IP54, NEMA 13
    3964N1600000
     

    Pressure Switches for Oxygen

    Cleaned to ASTM G93 requirements and then bagged, these switches meet the strict cleaning standards required for oxygen service lines. Removing all contaminants extends the life of the switch and helps maintain a safe environment.
    When a set pressure is reached, these switches can turn equipment on and off, activate automated controls, or signal alarms. They have an internal setpoint adjustment with a sliding cover to prevent accidental setting changes. They’re single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed).
    NEMA rated, they seal out dust and water from washdowns and the weather. These switches also meet UL 508, are CE marked, and are UL and C-UL recognized components, so they meet American, Canadian, and European safety standards.
    Wire Lead Connection
    Image of Product. Front orientation. Pressure Switches. Pressure Switches for Oxygen.
    Pressure Set Point
    Range, psi
    Approx. Difference Between Set
    Point and Reset Point, psi
    Max. Continuous
    Pressure, psi
    Max. Short-Term
    Pressure, psi
    Accuracy
    Max. Switching Current @ Voltage
    Process Temp.
    Range, ° F
    Connection
    Material
    For Use
    With
    Enclosure
    Rating
    Certification
    Each
    1/8 Threaded NPT Male Pipe
    4 to 503.51,0003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K120000000
    10 to 15061,5003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K14000000
    30 to 600342,5003,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K16000000
     
    1/4 Threaded NPT Male Pipe
    100 to 1,5001208,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K17000000
    180 to 3,0002258,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K18000000
    400 to 4,7003508,00010,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K19000000
    4,000 to 7,50067510,00012,000±1.5%5 amp @ 125V AC
    5 amp @ 250V AC
    3 amp @ 30V DC
    250 mA @ 125V DC
    0 to 200BrassOxygenNEMA 4
    C-UL Recognized Component, CE Marked, UL Recognized Component
    3427K21000000
     

    Insertion-Mount Flow Switches

    Image of Product. Socket Connection with IP65 Rating. Front orientation. Contains Annotated. Flow Switches. Insertion-Mount Flow Switches, Socket-Connect Fitting Connection, IP65 Enclosure Rating.
    Image of Product. Threaded Connection with IP65 Rating. Front orientation. Contains Annotated. Flow Switches. Insertion-Mount Flow Switches, Threaded Fitting Connection, IP65 Enclosure Rating.

    Socket

    Connection

    with IP65

    Rating

    Threaded

    Connection

    with IP65

    Rating

    Avoid complicated inline installation—these flow switches insert into a tee or pipe outlet, so you don’t need to disassemble your pipeline. They have a paddle that’s pushed as your liquid moves through to determine flow. When the paddle reaches a set position determined by the set point, it activates or deactivates equipment. They are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). They should be mounted vertically into a large-diameter horizontal pipeline, so liquid pushes the paddle.
    These flow switches are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Choose a fitting material that is compatible with the liquid you're running through your line.
    Noryl Body—Switches with a Noryl body have a paddle that you trim to adjust the set point. The more you trim, the higher the set point.
    Socket-Connect Fitting Connection—Socket-connect flow switches bond to an unthreaded PVC pipe tee or pipe outlet with PVC cement and primer (not included).
    Brass Fitting—Brass and 316 stainless steel fittings resist impact better than Noryl fittings.
    Noryl Fitting—Noryl fittings work with a wide range of chemicals.
    IP65 Enclosure Rating—IP65 rated switches seal out dust and can be lightly rinsed.
    For Pipe Size
    Flow Set Point Range, gpm
    Max. Flow Rate, gpm
    Paddle Material
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Max. Switching Current
    @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Specs.
    Met
    Each
    Noryl Body with 3/4 Socket-Connect Noryl Fittings
     
    Set-Point-Adjustment Trimmable Paddles
    1 1/2
    2
    3
    7.7 to 19.3
    10.3 to 21
    16.5 to 52
    110; 150; 390Noryl160 psi @ 70° F-13 to 2121 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 5082766K410000000
    1 1/2
    2
    3
    7.9 to 15
    10 to 22
    18 to 50
    144; 240; 650301 Stainless Steel
    160 psi @ 70° F-13 to 2121 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 5082766K111000000
     
    Noryl Body with 1/2 NPT Male Threaded Brass Fittings
     
    Set-Point-Adjustment Trimmable Paddles
    1 1/2
    2
    3
    4
    8
    7.7 to 19.3
    10.3 to 21
    16.5 to 52
    25.5 to 68
    126 to 240
    110; 150; 390; 420; 1,100Noryl160 psi @ 70° F-13 to 2121 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 5082766K43000000
    1 1/2
    2
    3
    4
    8
    7.9 to 15
    10 to 22
    18 to 50
    25 to 66
    114 to 176
    144; 240; 650; 800; 1,900301 Stainless Steel
    160 psi @ 70° F-13 to 2121 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 5082766K112000000
     

    Fixed-Set-Point Insertion-Mount Flow Switches

    Image of Product. Front orientation. Contains Annotated. Flow Switches. Fixed-Set-Point Insertion-Mount Flow Switches.
    Easy to install, these flow switches come already set to a specific set point and don’t require you to disassemble your pipeline. Instead of mounting them inline, insert them into an unthreaded PVC pipe tee or pipe outlet in large-diameter pipe. They have a paddle that’s pushed as your liquid moves through to determine flow. When the paddle reaches a set position determined by the set point, it activates or deactivates equipment. All are single pole, double throw (SPDT) and can either turn one device from off to on (normally open) or on to off (normally closed). IP rated, they seal out dust and can be lightly rinsed.
    They should be mounted vertically into a horizontal pipeline, so liquid pushes the paddle. Secure them with PVC cement and primer (not included).
    These flow switches are calibrated with water. You can use them with other liquids, but they may not measure accurately if the liquid’s viscosity differs from water.
    Pipe
    Connections
    For Pipe
    Size
    Set Point, gpm
    Max. Flow
    Rate, gpm
    Max. Pressure
    @ Temp.
    Temp. Range,
    ° F
    Voltage
    Max. Switching Current
    @ Voltage
    Body
    Ht.
    Enclosure
    Rating
    Specs.
    Met
    Each
    Noryl Body with Socket-Connect PVC Fittings
    1/2
    1/2
    1.037.9160 psi @ 70° F-13 to 212230V AC/48V DC1 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 5082766K1130000000
    3/4
    3/4
    1.9421160 psi @ 70° F-13 to 212230V AC/48V DC1 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 5082766K114000000
    3/4
    1
    1 1/4
    2.7, 6.831, 40160 psi @ 70° F-13 to 212230V AC/48V DC1 amp @ 230V AC
    1 amp @ 48V DC
    2 1/2"IP65
    UL 5082766K115000000
     
    back to top