About Pressure Switches
More
Economy Pressure Switches

Use these switches for applications that need reliable switching but don’t require high accuracy. When a set pressure is reached, they turn equipment on and off, signal automatic controls, or trigger alarms. These are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed). All meet safety standards.
For technical drawings and 3-D models, click on a part number.
Style | Setpoint, psi | Approximate Difference Between Setpoint and Reset Point, psi | Max. Continuous Pressure, psi | Max. Short-Term Pressure, psi | Accuracy | Max. Switching Current | Process Temperature Range, °F | Connection Material | For Use With | Each | |
Quick-Disconnect Terminals | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
1/4 NPT Male Pipe Connection | |||||||||||
A | 1.5-3.5 | 1.1 | 600 | 750 | ±8% | 15 A @ 250 V AC | -30° to 185° | Brass | Air, Diesel Fuel, Hydraulic Fluid, Water | 0000000 | 000000 |
A | 3-40 | 3.5 | 600 | 750 | ±3% | 25 A @ 250 V AC | -30° to 185° | Brass | Air, Diesel Fuel, Hydraulic Fluid, Water | 0000000 | 00000 |
A | 30-150 | 17.5 | 600 | 750 | ±4% | 25 A @ 250 V AC | -30° to 185° | Brass | Air, Diesel Fuel, Hydraulic Fluid, Water | 0000000 | 00000 |
A | 100-500 | 75 | 600 | 750 | ±5% | 25 A @ 250 V AC | -30° to 185° | Brass | Air, Diesel Fuel, Hydraulic Fluid, Water | 0000000 | 00000 |
Screw Terminals | |||||||||||
1/4 NPT Male Pipe Connection | |||||||||||
A | 1.5-3.5 | 1.1 | 600 | 750 | ±8% | 15 A @ 250 V AC | -30° to 185° | Brass | Air, Diesel Fuel, Hydraulic Fluid, Water | 0000000 | 00000 |
A | 3-40 | 3.5 | 600 | 750 | ±3% | 25 A @ 250 V AC | -30° to 185° | Brass | Air, Diesel Fuel, Hydraulic Fluid, Water | 0000000 | 00000 |
Economy Vacuum Switches

Choose these switches when you need reliable switching but not high accuracy. When they reach a set vacuum, they turn equipment on and off, signal automatic controls, or trigger alarms. They are single pole, double throw (SPDT) and can be installed to turn one circuit from off to on (normally open) or from on to off (normally closed). All meet American and European safety standards since they're UL recognized components and CE marked.
For technical drawings and 3-D models, click on a part number.
Setpoint, in. of Hg | Approximate Difference Between Setpoint and Reset Point, in. of Hg | Maximum Continuous Pressure, psi | Maximum Short-Term Pressure, psi | Accuracy | Process Temperature Range, °F | Connection Material | For Use With | Each | |
Spade Terminals | |||||||||
---|---|---|---|---|---|---|---|---|---|
1/8 NPT Male Pipe Connection | |||||||||
28.2-2.7 | 3 | 0 | 0 | ±5.5% | -30° to 185° | Chrome-Plated Zinc | Air, Argon, Cleaning Solutions, Diesel Fuel, Gasoline, Hydraulic Fluid, Inert Gas, Nitrogen, Oil, Oxygen, Water | 0000000 | 0000000 |